Solubility and density of p-dioxanone in organic solvent systems

  • Lee, Sang-Won;Kim, Sung-Il;Park, So-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.429-437
    • /
    • 2008
  • The p-dioxanone can be used to make a variety of commercially useful products particularly where biodegradability is desired, such as fibers, sutures, molded articles, containers, medical devices and surgical clips, film and compostable trash bags. The mole fraction solubility of p-dioxanone in various solvents such as acetone, ethylacetate, tetrahydrofuran, methanol, ethanol, 1-propanol, 1-butanol and 1-pentanol were measured over the temperature range from 263.05 K to 288.45 K. The solubility of p-dioxanone increases with increasing polarity of the solvents.

Analytical Studies on Leaching of Plasticizers from Medical Grade Polyvinyl Chloride Containers (폴리염화비닐 의료용기의 가소제의 정량 및 용출에 관한 연구)

  • Lee, Min-Hwa
    • Journal of Pharmaceutical Investigation
    • /
    • v.16 no.3
    • /
    • pp.106-109
    • /
    • 1986
  • The elution of di(2-ethylhexyl) phthalate (DEHP) from flexible bags into human blood or transfusion was studied. The conditions of determination of DEHP using high performance liquid chromatography (HPLC) was established as follows: Condition I-column, ${\mu}-Bondapak^{TM}\;C_{18}$; mobile phase, methanol: water=91 : 9 ; flow rate, 1.2ml/min; wavelength, 254nm; injection volume, $10{\mu}l$. Condition II-column, Lichorsorb RP-18$(10{\mu}m)$; mobile phase, methanol: water=94 : 6 ; flow rate, 1.1ml/min; wavelength, 254nm; injection volume, $10{\mu}l$. DEHP was found to be migrating from PVC blood and total parentral nutrient bags into methanol, but not into anti, coagulant drug solution.

  • PDF

Current Status of Infection Prevention and Control Programs for Emergency Medical Personnel in the Republic of Korea

  • Oh, Hyang Soon;Uhm, Dong Choon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.48 no.6
    • /
    • pp.330-341
    • /
    • 2015
  • Objectives: Emergency medical personnel (EMPs) are pre-hospital emergency responders who are at risk of exposure to infections and may also serve as a source for the transmission of infections. However, few studies of infection control have specifically addressed EMPs in the Republic of Korea (hereafter Korea). The goal of this study was to assess the current status of infection prevention and control programs (IPCPs) for EMPs in Korea. Methods: A cross-sectional survey was conducted to quantitatively assess the resources and activities of IPCPs. A total of 907 EMPs in five metropolitan cities completed a structured questionnaire from September 2014 to January 2015. The data were analyzed using descriptive statistics, multi-response analysis, and the chi-square test. Results: The mean age of the participants was $34.8{\pm}15.1years$. IPCPs were found to have weaknesses with regard to the following resources: the assignment of infection control personnel (ICP) (79.5%), hand hygiene resources such as waterless antiseptics (79.3%), the use of paper towels (38.9%), personal protective equipment such as face shields (46.9%), and safety containers for sharps and a separated space for the disposal of infectious waste (10.1%). Likewise, the following activities were found to be inadequately incorporated into the workflow of EMPs: education about infection control (77.5%), post-exposure management (35.9%), and the decontamination of items and spaces after use (88.4%). ICP were found to have a significant effect on the resources and activities of IPCPs (p<0.001). The resources and activities of IPCPs were found to be significantly different among the five cities (p<0.001). Conclusions: IPCPs for EMPs showed some limitations in their resources and activities. IPCPs should be actively supported, and specific IPCP activities for EMPs should be developed.

Development of Alginate-based Spray-type Hydrogel and Evaluation of Technical Compatibility for Container Application (알지네이트 기반 분사형 하이드로겔 개발 및 용기 적용에 대한 기술적합성 평가)

  • Yong Joon, Joo;Hee Kyung, Jeon;Jeong Yeon, Choi;Gyeong Sik, Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.1
    • /
    • pp.64-72
    • /
    • 2023
  • Initial burn wound care is one of the important factors in the outcome of burn treatment. In this study, we tried to develop spray-type alginate hydrogel dressing with advantages such as promoting wound healing, reducing pain, and increasing ease of use for emergency burn treatment. Spray implementation, physical properties, and cytotoxicity of the newly developed spray-type alginate hydrogel dressing were evaluated. As a result, a new functional spray-type hydrogel dressing with excellent physical properties and biocompatibility was developed along with the development of spray able containers, and it was confirmed that it could be applied as a treatment for skin regeneration in the future.

Ocular chemical burns following accidental instillation of tinea pedis treatment solution: A report of two cases (족부백선 치료액 오인 점안 후 발생한 안구화학손상 2례)

  • Kim, Jung Ho;Chung, Han Sol
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.20 no.1
    • /
    • pp.35-38
    • /
    • 2022
  • Many commonly used household chemicals and medical eye drops look alike, resulting in a worldwide increase in incidences of accidents caused by confusion between similar-looking agents. In this case report, we present two patients who visited the emergency department following inadvertent instillation of tinea pedis treatment solution instead of eye drops. Both patients developed corneal chemical burns following the accidental application. Notably, the visual acuity and symptoms eventually recovered for both patients after hospitalization. However, complete recovery occurred only after several weeks. Both patients were relatively old and had been prescribed eye drops after previous ophthalmic surgery. Since the eye is a sensory organ that receives visual information, ocular injuries significantly affect the quality of life and social functioning of the patient. Incidences of accidental misidentification of eye drops are steadily increasing in South Korea; unfortunately, regulatory policies are unavailable to avoid such hazards. Therefore, physicians should be mindful of the potential risks associated with misidentification of everyday household products and must spend time educating patients when prescribing eye drops. Policy regulations are warranted for products with containers that resemble eye drop bottles. Such items need to be clearly labeled with additional warnings to prevent misidentification and accidental ocular instillation.

Design and Implementation of Mobile Healthcare System supporting Safe Transfusion (안전한 수혈을 지원하는 모바일 헬스케어시스템의 설계 및 구현)

  • Kang, Moon-Seol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.8
    • /
    • pp.1845-1852
    • /
    • 2015
  • From bar code systems and radio frequency identification (RFID) to beacons utilizing low power bluetooth technology, the fusion of information technology and health and medical treatment is spreading through advances such as automated treatment and examination stages and the use of treatment information connected to smart devices. In this paper, designed and implemented a mobile health care system for the safe management of blood transfusions to prevent accidental problems that can occur during patient blood transfusions. It makes safe and effective blood transfusion possible by using smart devices to read information saved on patient bracelets, blood-collecting containers, blood transfusion bags, and medical personnel identification cards so that they match patient information. By applying the blood transfusion management mobile health care system presented and implemented in this paper to blood transfusion processes in hospitals, it was verified that it allows for safe and effective blood transfusion, preventing accidents which may occur in blood transfusion processes.

Causes of Bacterial Growth in Gels and Gel Containers Used for Ultrasonography (초음파 검사용 젤과 젤 용기의 세균증식 원인)

  • Kim, A-Young;Cho, Pyoung-Kon;Song, Do-Young;Kim, Su-Jung
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.359-365
    • /
    • 2020
  • This study aimed to investigate the causes of bacterial growth to prevent infection caused by ultrasound gel and gel containers in contact with patients during ultrasonography. To investigate bacterial contamination during manufacturing or storage, we cultured ultrasound gels originally supplied from three manufacturers. To analyze bacterial growth according to the lapse of time and frequency of use of the ultrasound gel container, the gel and container were cultured at regular intervals every week for 4 weeks. In addition, to determine the source of infection, the examiner's hand was inspected with hand plate and the degree of bacterial contamination was measured before the test. As a result of the study, bacteria were not detected in the gel provided at the initial supply, and in the gel and gel container used repeatedly for 4 weeks, the same bacteria residing on the skin were identified in the examiner's hand, such as Staphylococcus epidermidis, Micrococcus luteus, Leuconostoc mesenteroid spp cremoris, Kocuria rhizophila, and etc. Separated strains were classified as those of the low- or non-pathogenicity; however, most of these strains may render fatal consequences to patients of lower level of immunity due to acquired tolerance to antibiotics. At week 1, when the number of tests was the highest, 44 colonies were identified, and at week 4, when the number of tests was the lowest, 4 colonies were identified. As r=0.994, it was found that the number of colonies increased as the number of tests increased. In conclusion, it was confirmed that the cause of the infection was not the ultrasound gel, but the examiner's hand. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. The ultrasound gel or gel container may be contaminated by skin flora of examiner's hands, which can cause opportunistic infection in patients with low immunity. Therefore, it was confirmed that thorough hand disinfection was necessary to block healthcare-associated infections.

Optical Sensor of Coplanar Structure Study and Design for Intravenous Solution Exhaustion Alarm System (수액 소진 알람시스템을 위한 동일평면형 광센서의 연구 및 제작)

  • Park, Hyo Soon;Kim, Tae Yun;Jung, Eui Sung;Seong, Ki Woong;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.113-118
    • /
    • 2015
  • Intravenous (IV) infusion set is one of the most common treatment methods applied to hospitalized patients. However, it is necessary to check the injection of IV solution in order to prevent patients from any possible medical injuries. In this paper, using the optical sensors to detect exhaustion of IV solution was proposed. The optical sensor is coplanar structure composed of LED and photodiode which is installed according to focal distance of the lens. These two elements detect exhaustion of IV solution at the desired point conveniently. Through the results of experiments using various wavelength of LED (R.G.B), the blue LED was selected to the optimum light source. The suggested optical sensor can detect exhaustion of IV solution by the differences in the amount of light which is caused by properties such as total reflection, refractive index and scattering. From the implementation, the detector is applicable to both containers of IV solution, glass bottle and plastic pack. And also the result shows apparent differences according to existence of IV solution even if the IV solution color and illumination were changed.

Effect of Magnetism on the Growth of Several Foliage Plants (몇몇 관엽식물의 생장에 미치는 자기(磁氣)의 영향)

  • Jeong, Seo-Goo;Kim, Sun-Hae;Bang, Kwang-Ja
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.8 no.5
    • /
    • pp.19-27
    • /
    • 2005
  • The earth is a huge magnet. All organisms live under the magnetism of earth. The magnetism influences the ions in the cells of organisms and variously functions to lives as well. The medical treatment with magnet has come down from the ancient, it has an effect on the plants' growth. But there are no scientific studies about the influences of magnetism on plant growth. Accordingly, the experiment about the influence of magnetism on several foliage plants was carried out in this study. The promotion of plants' growth led by magnetism will be the method to save the management cost of horticultural market by early shipment. As a results of this experiment, plants treated with magnets showed excellent growth especially in length growth. The experiment results of the respective plants are the following. 1. Rhapis flabelliformis : This have grown so very well in the container lined with magnets as time goes by. Showing the significant(p<0.05) differences, the length growth of Height and Length of leaves was especially distinguished. 2. Howea belmoreana : This has grown well in all containers. Showing the significant(p<0.05) differences, the length growth of Height and Length of leaves was especially distinguished. 3. Chamaedorea seifrizii : There have been the growth differences between Height and Length of leaves as time goes by. The growth of Height and Length of leaves in the container lined with magnets has been excellent. The number of leaves and number of branch generally had no big differences but the growth of Height and Length of leaves was excellent in the magnet container. The method of plant growth promotion with magnet should save the management cost for this reason. Therefore the succeeding studies about the plant growth under the influence of magnet intensity and kind must be performed. The studies with various plants are needed to activate the program for growing plants with magnet.

Package Design Proposal to Improve Medical Information Transmission on Regular Medicine Sold in Convenience Stores (편의점 판매용 안전상비의약품의 정보 전달 개선을 위한 포장디자인 제안)

  • Kim, Min Ji;Jung, Eui-Tay;Paik, JinKyung
    • Design Convergence Study
    • /
    • v.15 no.4
    • /
    • pp.17-29
    • /
    • 2016
  • Over-the-counter pharmaceuticals sold in convenience stores are accurate and easy to understand on its containers, packaging, or attached materials for the prevention of drug misuse. The limited space of the packaging, however, makes the information difficult to read and consequently, consumers have had difficulty in purchasing the products. This research conducted an analysis of 8 packages of pill-type drugs and conducted a survey and interviews targeting 10 foreigners and 20 Korean consumers to analyze the user consciousness. The findings of this study showed that fever remedies are the most frequently bought drug. And consumers first looked for the information of the drugs in the following order: the effects, dosage, and warnings. While domestic consumers had little difficulty in comprehending the information, more than 40% of the foreigners who were studies failed to comprehend it, which was because the package was entirely written in Korean. This study presented some ideas for improving the design by using English and foreign expressions and pictograms, consumers can easily and quickly understand, and by placing the information on the symptoms, dosage and age information so that the type of drugs will be easily discernible.