• 제목/요약/키워드: Mechanical tests

검색결과 4,900건 처리시간 0.036초

Evaluation of Thermal Durability of Thermal Barrier Coating and Change in Mechanical Behavior

  • Lee, Dong Heon;Kang, Nam Kyu;Lee, Kee Sung;Moon, Heung Soo;Kim, Hyung Tae;Kim, Chul
    • 한국세라믹학회지
    • /
    • 제54권4호
    • /
    • pp.314-322
    • /
    • 2017
  • This study investigates changes in the mechanical behavior, such as changes in indentation load-displacement curve, wear resistance and contact fatigue resistance of thermal barrier coatings (TBCs) by thermal cycling test and thermal shock test. Relatively dense and porous TBCs on nickel-based bondcoat/superalloy are prepared; the highest temperature applied during thermal durability test is $1350^{\circ}C$. The results indicate that the porous TBCs have relatively longer lifetime during thermal cycling and thermal shock tests, while denser TBCs have relatively higher wear and contact fatigue resistance. The mechanical behavior is influenced by sintering of the TBCs by exposure to high temperature during tests.

Pultrusion 복합 샌드위치 패널의 신뢰성 평가 (Reliability Evaluation on Pultrusion Composite Sandwich Panel)

  • 이학성;김은성;오제하;김동기;이주영;강신재
    • 한국생산제조학회지
    • /
    • 제22권3호
    • /
    • pp.414-420
    • /
    • 2013
  • Research on decreasing the weight of composite sandwich panels is in progress. This paper reports the experimental results for the mechanical behavior of a composite sandwich panel. The skins of sandwich panels were made of glass fiber sheets and plywood matrix composites. Their interior layers consisted of glass fiber pultrusion pipes and gold foam. Experimental tests were performed to obtain the mechanical properties and complex mechanical behavior. Before fatigue tests, tensile tests and 3-point bending tests were carried out to obtain the optimal design and determine their strength and failure mechanisms in the flat-wise position. After the static test, a fatigue test were conducted at a load frequency of 5 Hz, stress ratio (R) of 0.1, and endurance limit for the S-N curve. It showed that the failure modes were related to both the core design and skin failure.

EFFECT OF SOLUBLE ADDITIVES, BORIC ACID (H3BO3) AND SALT (NaCl), IN POOL BOILING HEAT TRANSFER

  • Kwark, Sang-M.;Amaya, Miguel;Moon, Hye-Jin;You, Seung-M.
    • Nuclear Engineering and Technology
    • /
    • 제43권3호
    • /
    • pp.195-204
    • /
    • 2011
  • The effects on pool boiling heat transfer of aqueous solutions of boric acid ($H_3BO_3$) and sodium chloride (NaCl) as working fluids have been studied. Borated and NaCl water were prepared by dissolving 0.5~5% volume concentration of boric acid and NaCl in distilled-deionized water. The pool boiling tests were conducted using $1{\times}1\;cm^2$ flat heaters at 1 atm. The critical heat flux (CHF) dramatically increased compared to boiling pure water. At the end of boiling tests it was observed that particles of boric acid and NaCl had deposited and formed a coating on the heater surface. The CHF enhancement and surface modification during boiling tests were very similar to those obtained from boiling with nanofluids. Additional experiments were carried out to investigate the reliability of the additives deposition in pure water. The boric acid and NaCl coatings disappeared after repeated boiling tests on the same surface due to the soluble nature of the coatings, thus CHF enhancement no longer existed. These results demonstrate that not only insoluble nanoparticles but also soluble salts can be deposited during boiling process and the deposited layer is solely responsible for significant CHF enhancement.

Effect of bound water on mechanical properties of typical subgrade soils in southern China

  • Ding, Le;Zhang, Junhui;Deng, Zonghuang
    • Geomechanics and Engineering
    • /
    • 제27권6호
    • /
    • pp.573-582
    • /
    • 2021
  • From the effect of bound water, this study aims to seek the potential reasons for difference of mechanical experiment results of subgrades soils. To attain the comparatively test condition of bound water, dry forming (DF) and wet forming (WF) were used in the specimen forming process before testing, series of laboratory tests, i.e., CBR tests, direct shear tests and compaction tests. The measured optimal moisture contents, maximum dry densities, CBR, cohesion c, and internal friction angle 𝜑 were given contrastive analysis. Then to detect the adsorptive bound water in the subgrade soils, the thermal gravimetric and differential scanning calorimetry (TG-DSC) test were employed under different heating rates. The free water, loosely bound water and tightly bound water in soils were qualitatively and quantitatively analyzed. It was found that due to the different dehydration mechanics, the lost bound water in DF and WF process show their own characteristics. This may lead to the different mechanical properties of tested soils. The clayey particles have a great influence on the bound water adsorbed ability of subgrade soils. The more the clay content, the greater the difference of mechanical properties tested between the two forming methods. Moreover, in highway construction of southern China, the wet forming method is recommended for its higher authenticity in simulating the subgrade filed humidity.

터어빈 로우터용 강에 대한 기계적 성질로부터 파괴인성치$K_IC$예측에 관한 연구 (Prediction of fracture toughness for turbine rotor steels from their mechanical test results)

  • 이학문;정순호;장윤석;이치우
    • 대한기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.717-724
    • /
    • 1987
  • 본 연구에서는 한국중공업에서 실제로 제작한 터어빈 로우터를 시험편으로 하 여 -150.deg. C에서 +150.deg. C에 걸쳐 인장시험, 충격시험 및 파괴인성시험을 실시하여 각 온 도에서 기계적 성질과 파괴인성치를 시험적으로 구하고 Begley-Logsdon의 방법에 따라 파괴인성치를 예측하여 예측방법의 유용성 여부를 조사하고 또한 파단면의 양상을 함 께 검토하였다.

세라믹 코팅 Al 부스바의 열적·기계적 특성 (Thermal and Mechanical Properties of Ceramic Coated Al Bus Bar)

  • 곽동순;백승명;곽민환
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1651-1656
    • /
    • 2017
  • This paper deals with the thermal and mechanical properties of ceramic coating material for bus bars. A ceramic coated samples were prepared for the mechanical properties test. There are two types of samples. One is a square shape and the other is a busbar shape. Each sample was deteriorated for 30 days to compare the thermal and mechanical properties with the non-degraded samples. Two thermal properties tests are TGA and flammability tests, and four mechanical properties tests are drop impact test, cross cut, tensile test, and bend test. The ceramic coating material was never damaged by impact and did not separate from aluminum in the cross cut test. In the tensile test, the breakage of the insulating material did not occur until aluminum fractured, and the breakage of the insulating material did not occur until the maximum load in the bending test. The decomposition temperature (melting point) of the ceramic coating material was higher than that of other epoxy insulators. This ceramic coating material is nonflammable and it has excellent fire stability.

Study on Unmanned Hybrid Unmanned Surface Vehicle and Unmanned Underwater Vehicle System

  • Jin, Han-Sol;Cho, Hyunjoon;Lee, Ji-Hyeong;Jiafeng, Huang;Kim, Myung-Jun;Oh, Ji-Youn;Choi, Hyeung-Sik
    • 한국해양공학회지
    • /
    • 제34권6호
    • /
    • pp.475-480
    • /
    • 2020
  • Underwater operating platforms face difficulties regarding power supply and communications. To overcome these difficulties, this study proposes a hybrid surface and underwater vehicle (HSUV) and presents the development of the platform, control algorithms, and results of field tests. The HSUV is capable of supplying reliable power to the unmanned underwater vehicle (UUV) and obtaining data in real time by using a tether cable between the UUV and the unmanned surface vehicle (USV). The HSUV uses global positioning system (GPS) and ultra-short base line sensors to determine the relative location of the UUV. Way point (WP) and dynamic positioning (DP) algorithms were developed to enable the HSUV to perform unmanned exploration. After reaching the target point using the WP algorithm, the DP algorithm enables USV to maintain position while withstanding environmental disturbances. To ensure the navigation performance at sea, performance tests of GPS, attitude/heading reference system, and side scan sonar were conducted. Based on these results, manual operation, WP, and DP tests were conducted at sea. WP and DP test results and side scan sonar images during the sea trials are presented.

중간토의 역학적 특성에 관한 실험적 연구 (Laboratorial Study for Mechanical Prosperities of Intermediate Soils)

  • 박중배;전몽각
    • 한국지반공학회지:지반
    • /
    • 제11권3호
    • /
    • pp.113-122
    • /
    • 1995
  • 본 논문은 소성지수 약30의 해성점토에 모래 및 모래로 제작한 실트분을 혼합하여 제작한 중간토의 역학적 성질을 파악하는데 그 목적을 두고 있다. 실험으로는 물리적 실험을 거친 후, 공학적 특성을 살피기 위해 압밀시험과 삼축압축전단시험을 하였다. 압밀시험에서는 오성지수의 변화에 따라 중간토의 압밀특성, 즉 압밀곡선의 형태와 투수성 및 압축성이 변화하는 것으로부터 중간토와 점토의 영역을 구분하였다. 한편, 삼축압축전단시험에서는 배수조건에 따른 각각의 시료의 압축전단특설을 밝히고, 특히 비배수조건하에서는 변형률 속도가 전단특성에 끼치는 영향을, 그리고 변형률속도와 소성지수 및 시료의 과압밀비의 변화에 따른 변형률경화 현상의 특성과 그 원인을 전단 중에 측정한 간극수압의 거동으로부터 규명하였다. 아울러 중간토의 전단특성에 미치는 배수조건과 변형률속도의 영향을 비교검토하였다.

  • PDF

복합말뚝 연결부 안정성 평가 및 수평거동특성 분석 (Joint Stability and lateral behavior of composite piles)

  • 신윤섭;박재현;황의성;조성한;정문경;부교탁
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.553-558
    • /
    • 2010
  • The behavior of composite piles composed of steel pipe pile in the upper part and concrete pile in the lower part by a mechanical splicing joint was examined by field lateral load tests and bending tests. A total of 7 piles including two instrumented piles for bending test were installed. The soil profile consists of soft clay with weak silt with shallow groundwater level. Laboratory tests were carried out to determine the basic soil characteristics and the strength parameters. This paper presents the composite pile behavior with various portions of the upper steel pile: 0, 20, 30, and 45% of the pile embedded pile length. Three-point bending tests were performed to investigate the stress-strain relation at the mechanical joint. Based on these test results, the behavior of composite piles with various upper steel pile length are evaluated and the stability of mechanical joints are examined. Through comparisons with results of field load tests, it was found that lateral load carrying capacity of the composite piles increased and deflections of the composite piles decreased with increasing the upper steel piles. The mechanical joint was proved to retain its structural stability against the tested load conditions. Economical benefits of composite pile of this kind can be gained by setting adequately the length of the upper steel pipe piles.

  • PDF

누설 저감을 위한 75톤급 터보펌프 개량형 미케니컬 페이스실 개발 (Development of Mechanical Face Seal in 75-tonf Turbopump for Leakage Reduction)

  • 배준환;곽현덕;이창훈;최종수
    • Tribology and Lubricants
    • /
    • 제36권2호
    • /
    • pp.75-81
    • /
    • 2020
  • In this paper, we present an experimental investigation of the leakage and endurance performances of mechanical face seals in a 75-tonf turbopump for the Korea Space Launch Vehicle II first-stage engine. A mechanical face seal is used between the fuel pump and turbine to prevent mixing of the fuel and turbine gas. However, excessive leakage occurs through the carbon attached to the mechanical face seal bellows. To reduce this leakage, we redesign the mechanical face seal such that the contact area between the fuel and carbon is reduced, height of the carbon nose is reduced, and stiffness of the bellows is increased. Then, we conduct static and dynamic leakage tests and endurance tests to compare the performances of the original and modified mechanical face seals. The investigation of the leakage of the old and new mechanical face seals confirms that the leakage performance is significantly improved, by 80%, in the new design in comparison with the old design. The endurance tests demonstrate that the average wear rate of carbon in the new mechanical face seal is 0.1094 ㎛/s. The service lifetime is predicted to be 4,200 s, which is 28 times greater than the requirement. Finally, we present a new mechanical face seal in a 75-tonf turbopump, and perform a validation test in the real-propellant test facility at the NARO Space Center. Based on the test results, we can confirm that the modified mechanical face seal works well under real operating conditions.