• Title/Summary/Keyword: Measuring instruments

Search Result 532, Processing Time 0.031 seconds

A Development of the Management Standard for Effective Control of Measuring Instruments (계측기기의 효율적 운영을 위한 관리표준 개발)

  • Lee, Sung-Woong;Kim, Soo-Dong;Kim, Jung-Sik
    • Journal of Korean Society for Quality Management
    • /
    • v.27 no.2
    • /
    • pp.201-217
    • /
    • 1999
  • Industrial Measuring Instrument is a general name of equipments or tools for measuring and weighing. Inaccurate measuring instruments produce inferior goods in spite of excellent experts, good materials and wonderful equipments. Three characteristics are important for measuring instruments: choosing the proper instruments for measuring, using them properly and managing them to keep accuracy and precision. The purpose of this thesis is to develope the management standard for effective control of measuring instruments by analysing the problems and the management conditions of 100 PPM certified companies out of the domestic small and medium manufacturing industry, which steadily carry out quality control.

  • PDF

An Analysis on Elementary Students' Measuring Abilities by Using a Microgenetic Method (미시발생학적 방법을 이용한 초등학생의 측정 능력 분석)

  • Yang, Il-Ho;Song, Jin-Lyoung;Lim, Sung-Man;Lim, Jae-Keun
    • Journal of Korean Elementary Science Education
    • /
    • v.27 no.4
    • /
    • pp.341-355
    • /
    • 2008
  • The purpose of this study was to analyze the measuring abilities of elementary school students by using a microgenetic method. The participants were seven elementary students in the fourth grade. To analyze their measuring abilities, students attended three physical quantities measuring tasks such as length, volume, and time task by six times. Results were as follows. First, in the measuring length task, students selected appropriate measuring instruments but they didn't consider measuring amounts. And as their measuring experience increased, they desirably improved management abilities of measuring instruments. In the measuring volume task, they dealed with measuring instruments, but not very well. And these tendency were maintained. In the measuring time task, they were not measure exactly. Second, as their measuring experience increased, their ability to read the scale marks improved. However, they had difficulties in estimating the volume between scale marks. Results indicate that, elementary students need to basic education about measuring instruments, their usage, and scale reading ability for their science experiment courses in schools.

  • PDF

Investigation on the Students' Abilities of Reading Scales and Conceptions Related with Measuring Instruments and Units (초.중학생의 눈금 읽기 능력 및 측정 도구와 단위에 관련된 개념 조사)

  • Soh, Jong-Ah;Jong, Hee-Kyong;Jung, Yong-Jae
    • Journal of The Korean Association For Science Education
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • This study investigated both elementary and middle school students' abilities of reading scales and students' conceptions of measuring instruments and units. Seventy two students with 5th grade, sixty nine students with 7th grade, and eighty students with 9th grade were participated. Performance tests and written questionnaires were used. To assess their scale reading abilities, individual performance test was used. Every student should measure length of an envelope, temperature of water, volume of water, etc. And to find out students' conceptions related with measuring instruments and units, written questionnaires with pictures and photographs were used. Some of the students' abilities of reading scales were considerably poor. The results of a two-plate-balance and measuring-cylinder were worse than those of a ruler, a spring-balance, and a thermometer. Many of the students had misconceptions related with measuring instruments. Some of them did not know exactly the meaning of volume, or mass, or force. So they did not know what to measure with the measuring instruments. Also students were confused with several units of volume, force, weight and mass.

  • PDF

Approach of Self-mixing Interferometry Based on Particle Swarm Optimization for Absolute Distance Estimation

  • Li, Li;Li, Xingfei;Kou, Ke;Wu, Tengfei
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.95-101
    • /
    • 2015
  • To accurately extract absolute distance information from a self-mixing interferometry (SMI) signal, in this paper we propose an approach based on a particle swarm optimization (PSO) algorithm instead of frequency estimation for absolute distance. The algorithm is utilized to search for the global minimum of the fitness function that is established from the self-mixing signal to find out the actual distance. A resolution superior to $25{\mu}m$ in the range from 3 to 20 cm is obtained by experimental measurement, and the results demonstrate the superiority of the proposed approach in comparison with interpolated FFT. The influence of different external feedback strength parameters and different inertia weights in the algorithm is discussed as well.

A Review of the Korean Nursing Research Literature with Focus on Quantitative Measurement of Caring (돌봄 측정 관련 국내 간호학 연구 문헌고찰: 양적 연구를 중심으로)

  • Kim, Jeong-Hee;Park, Young Sook
    • Research in Community and Public Health Nursing
    • /
    • v.29 no.2
    • /
    • pp.155-169
    • /
    • 2018
  • Purpose: The purpose of this study is to review the quantitative research literature on measuring caring in order to identify overall trends in measuring caring. Methods: Fifty three papers were selected from four databases including RISS4U, DBpia, KISS, and Korea Med. Results: The number of measuring caring papers has increased since 2000. Approximately 60 % of the total papers were descriptive and correlative design researches with convenience sampling. Jean Waston's theory was the most popular conceptual framework, but much of the research tended to be conducted without any conceptual framework. In that kind of research, 'caring' terms were used without definition. The most frequently used term for the concept of caring was nurses' caring behaviors. Also, 'nurses' was one of the most popular subjects. Thirty six measuring caring instruments were used. Twenty were developed in foreign countries and translated into Korean. The others were developed originally in Korean. Interpersonal Caring Technique - Communication Skills Scale, based on the interpersonal process model, was the most frequently used tool. Among the translated instruments, Coates' Caring Efficacy Scale was the most popular. Some instruments were used without validation. Conclusion: These results provide basic data on measuring caring and indicate directions for further research. In particular, validation studies of measuring caring instruments are needed.

A study on the methods of identifying and verifying the causes of defects on rock bolt stressmeter and rod extensometer (터널계측용 록볼트축력계와 지중변위계의 불량원인 파악과 검증방법에 대한 연구)

  • Kim, Yeong-Bae;Noh, Won-Seok;Lee, Seong-Won;Jeon, Hunmin;Lee, Kang-Il
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.5
    • /
    • pp.411-429
    • /
    • 2022
  • Instrumentations are essential in NATM tunnels, however measuring instruments are installed and applied without performance verification procedures due to insufficient research on methods, procedures, regulations, etc. to verify the reliability of the measuring instruments. In this study, domestic and foreign regulations relating to the verification and calibration of instruments were investigated and necessities for accreditation standards were proposed. In order to identify the causes of the defects, an external inspection was performed on rock bolt stressmeter and rod extensometer, which are measuring instruments with relatively complex structures. For verifying the performance of these instruments, verification devices were developed that can load step-by-step and the causes of defects were identified in measuring instruments of nine domestic manufacturers. Through the performance test, a number of measuring instruments were found to be defective. It was important to test the performance of the instruments in the state of a finished product and accordingly performance inspection methods and procedures were proposed. The results of this study are expected to help preparing related regulations for verifying instrument performance and selecting instruments in the field.

Reliability of measurement devices for measuring the ankle joint motion (발목 관절 가동범위 측정을 위한 측정도구의 신뢰도 연구)

  • Hong, Wan-Sung;Kim, Gi-Won
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • Purpose: The purposes of this study were to establish the concurrent validity of the universal goniometer and electronic inclinometer for ankle joint of motion, and to determine the inter-tester and the intra-tester reliability of these two instruments. Methods: Subjects were instructed 25 healthy subjects. Ankle range of motion was measured on two separate occasions 2 or 3 days by two physical therapists. Ankle dorsiflexion and plantarflexion was by using an universal goniometer and an electronic inclinometer. Results: The Pearson product-moment correlation between the two instruments was 0.78~0.80. The ICCs for inter-tester reliability ranged from 0.63 to 0.73 for universal goniometer and ranged from 0.81 to 0.88 for electric inclinometer. The ICCs for intra-tester reliability showed a wide variation(ICC=0.61 to 0.86). Conclusion: These findings indicate that the two instruments are reliable instruments for measuring ankle joint range of motion. The results also indicate that the two instruments can be used interchangeably for measuring ankle motions.

  • PDF

Design and Implementation of Remote Control System for Measuring Instrument using Smart Network Card (스마트 네트워크 카드를 이용한 계측기 원격 제어 시스템 설계 및 구현)

  • Park, Jin-Ho;Jung, Min-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.10
    • /
    • pp.1366-1375
    • /
    • 2008
  • To verify correct operation of measuring instruments, we request the verification of measuring instrument to the agency that holds inspection devices. This works requires time and cost to the company. For this reason. We proposed "Smart Network Interface Card Model" for remote control of measuring instruments. Our model based on Web adapter, can add, delete and change the program to an existing web adapter from remote system. Furthermore, more than one program can be loaded, and can be updated from the remote system of internet. And also we can change the verification requirement of measuring instrument, hence it makes more good quality and competitive power of instruments.

  • PDF

An Analysis of Reliability by Factors for Development of Job Stress Measurement Tools of Radiological Technologists (방사선사의 직무 스트레스 측정도구 개발을 위한 요인별 신뢰도 분석)

  • Jung, Hong-Ryang;Son, Bu-Soon;Lim, Cheong-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.2 s.89
    • /
    • pp.103-110
    • /
    • 2006
  • The present study is designed to analyze reliability and validity of the instruments used to measure job stress of radiological technologists mainly by means of the questionnaires from 'Korean edition of NIOSH check list'. The subjects of this study are 890 radiological technologists active at 44 general hospitals in 16 provinces and cities across the country. The item-total reliability revealed that 10 factors in 6 are the major causes of stress in job life of radiological technologists. The measuring instrument proved to be valid with reliability coefficient of internal consistency by factors being more than 0.7. The factors found to be applicable herewith include limit and authority of job (0.73), cohesion within departments (0.86), resources control (0.81), mental requirements (0.85), job load (0.82), and job stability (0.72). When job autonomy item of causes are modified for proper use to radiological technologists, the measuring instruments are expected to show high reliability. It seems, however, necessary to develop a measuring instrument to analyze and use the validity of related measuring instruments since the reliability here was rated low, with statistical coefficients lower than 0.7 in such factors as job management (0.57), conflicts within departments (-1.13), sense of responsibility for patients (0.66) and usage of education (0.26). As this study was intended to examine reliability and validity of the concepts related to measurement of job stress on the part of radiological technologists, it nay not be proper to apply the results of this study to general use, but is advised to utilize them as basis for developing instruments to verify reliability and validity by comparing with and analyzing other measuring instruments.

Precision Shape Control in Plate Rolling (후판압연에서의 고정도 형상제어기술)

  • 서재형;정병완;홍헌호
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.452-456
    • /
    • 1999
  • Newly constructed plate shape control system, using attached shape measuring instruments and work roll bender, was put in service in No. 2 Plate Mill, POSCO. Recently, customers demand the improvement of flatness and plate crown accuracy. Many competition Plate Mill introducted shape control system, for example, pair cross mill, work roll bender which includes shape measuring instrument and shape control mathematical models, and No. 2 Plate Mill, POSCO introducted work roll bender and shape measuring instruments. This report describes the properties of No. 2 Plate Mill shape control system and work roll bender.

  • PDF