• Title/Summary/Keyword: Measuring Thickness

Search Result 799, Processing Time 0.032 seconds

Measurement of Thickness and Position of the Surface using the Two Encoder Ultrasonic Sensors (두개의 엔코드 초음파 센서를 이용한 측정면의 두께 측정 및 위치 측정)

  • 강명철;장유신;김형국;배종일;이만형
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.510-514
    • /
    • 2002
  • The 3-dimensional measuring machine by using an ultrasonic sensor is used one of the NDE(Non Destructive Examination). It is applied to the inspection of pipelines, boreholes, pressure vessel and tank, and so on. In particular when a harsh environment prohibits the use of moving mechanical parts. The 3-dimensional measuring machine by using an ultrasonic sensor, which measure 1-dimensional information and 2-dimensional information simultaneously from a target of inspection, and then reembody 3-dimensional information. So we can find the situation in progress and predict remaining life and corrosion without destructive examination. It's a point of excellence that the 3-dimensional measuring machine is portable.

  • PDF

Tomographic reconstruction of Asymmetric Spray by Direct Sampling Method (직접샘플링에 의한 비대칭 분무의 토모그래피 재구성)

  • Lee, C.H.;Won, J.C.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.9-15
    • /
    • 2002
  • Convolution Fourier transformation tomographically reconstructs the spatially resolved spray injection rate from direct measuring cells. Asymmetric sprays generated from a twin-hole air shroud injector are tested with 12 equiangular projections of measurements. For each projection angle, line of sight integrated injection rate was measured at 35 positions with equal spacing measuring cells of 3 mm in width, 100 mm in length, 55 mm in depth and 0.5 mm thickness of separating wall. Interpolated data between the projection angles effectively increase the number of projections, which significantly enhances the signal-to-noise level in the reconstructed data. This modified convolution Fourier transformation scheme predicts well the structure of asymmetric sprays. Comparative study has been made between sprays with and without air shrouding. Tomograhpic reconstruction of injection rate from direct measuring cells obtained can be used to estimate the accuracy of volume fraction of spray from the LDPA tomographic reconstruction.

  • PDF

Comparison Study of Sound Transmission Loss in High Speed Train

  • Kim, Tae-Min;Kim, Jeung-Tae
    • International Journal of Railway
    • /
    • v.4 no.1
    • /
    • pp.19-27
    • /
    • 2011
  • Many studies for improving the railway vehicle's performance and comfort such as speed, weight and noise are currently in progress. Improving the structural characteristics of the vehicle for greater noise insulation is considered important for reducing disturbance due to noise, but measuring transmission loss entails large costs. This study explores an alternative method for estimating and measuring the railway vehicle's transmission loss that involves on applying the numerical analysis coupled with scaled reverberation chamber measurement. The transmission loss measurement using scaled reverberation chamber was performed after the compensation value was found through 1mm thickness(1t) specimen. For numerical analysis, a commercially available acoustics solver VA ONE was used. The proposed method is found to lead to transmission loss measurement comparable to the measurements based on large-scale reverberation chamber. Thus, it can be argued that a reliable method has been developed for measuring railway vehicle's transmission loss.

Development of Hand-Held Type Sheet Resistance Meter Based on a Dual-Configuration Four-Point Probe Method (Dual-Configuration Four-Point Probe Method에 의한 휴대형 면저항 측정기 개발)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Kim, Wan-Seop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.423-427
    • /
    • 2010
  • Portable sheet resistance-measuring instrument using the dual-configuration Four-Point Probe method is developed for the purpose of precisely measuring the sheet resistance of conducting thin films. While single-configuration Four-Point Probe method has disadvantages of applying sample size, shape and thickness corrections for a probe spacing, the developed instrument has advantages of no such corrections, little edge effects and measuring simply and accurately the sheet resistance between $0.2\Omega/sq$ and $2k\Omega/sq$.

Effect of Outdoor Temperature on the Refrigerant Behavior in the Compressor of a Heat Pump Operating at Heating Mode (열펌프의 난방운전시 외기온이 압측기의 냉매거동에 미치는 영향)

  • 이재효;김병균;이건우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.5
    • /
    • pp.452-458
    • /
    • 2004
  • The major cause of compressor failure is the decrease of oil viscosity due to floodback. In most previous researches on the compressor reliability, the relationship between oil circulation rate and performance or oil viscosity has been studied. Another research topic is flow visualization by using a sight glass on the bottom of a compressor sump area and accumulator. Both oil film thickness and oil level through the sight glass should be assessed for compressor reliability if the oil content of the mixture is small and low viscosity raise poor lubrication of pump bearing. In this study, the compressor reliability was assessed by measuring the viscosity of the mixture and calculating oil film thickness. The analysis of the relationship between bottom shell super heat and oil film thickness at heating operation was peformed. It is concluded that bottom shell superheat does not perfectly stand for the mixture's behavior for a low ambient heating operation and oil film thickness can give more detailed and direct criteria for compressor reliability.

A Case of Pilomatrixoma after Split Thickness Skin Graft (식피술 후 발생한 모기질종 1례)

  • Choi, Jae Hoon;Park, Sung Gyu;Lee, Jin Hyo
    • Archives of Plastic Surgery
    • /
    • v.33 no.6
    • /
    • pp.753-756
    • /
    • 2006
  • Purpose: Pilomatrixoma is a benign, usually asymptomatic tumor. It presents clinically as a solitary superficial subcutaneous nodule measuring between 0.5 cm and 5 cm in diameter on the head or upper extremeties and has not been reported after skin graft. The objective of this article is to report our experience in treating pilomatrixoma which occurred after split thickness skin graft on the lower extremity. Methods: A 56-year-old female was treated in August 2005 with a $0.5{\times}0.5cm$ firm subcutaneous nodule at recipient site of split thickness skin graft on the left medial thigh. The tumor was successfully removed by complete excision and histologic examination was followed. Results: The diagnosis was pilomatrixoma which was characterized by a dual population of proliferating basophilic cells and diagnostic shadow cells. Conclusion: The tumor was successfully treated by complete resection. The authors report this very rare case of pilomatrixoma which occurred at recipient site of split thickness skin graft.

A Study on the Dielectric Properties of Ferroelectric Materials (강유전체의 유전율 특성에 관한 연구)

  • Cho, Ik-Hyun;Park, Young;Jeong, Kyu-Won;Jung, Se-Min;Yi, Jun-Sin;Song, Jun-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.287-290
    • /
    • 1998
  • It was investigated that the dielectric properties of ferroelectric materials using PZT-5A and PZT thin films. PZT-5A was 20mm diameters, 0.71mm, 0.51mm and 0.41mm thickness respectively and having c-axis preferred orientation. Electrodes(Al) were deposited by evaporation method. PZT thin film was deposited on Pt/SiO$_2$/Si substrate by RF magnetron sputtering method, and annealed at 750$^{\circ}C$ with RTA. Dielectric constants were measured automatically by computer measuring system. Dielectric constants were changed rapidly from 817 to 888 in 0.41mm thickness PZT-5A, 823 to 890 in 0.51mm and 822 to 839 in 0.71mm as the electric field grown. In the case of PZT thin film, dielectric constants were changed from 724 to 1173 in 4500${\AA}$ thickness, 721 to 1204 in 5500${\AA}$ thickness and 811 to 1407 in 7000${\AA}$ thickness.

  • PDF

A Preliminary Study on the Fitness of Adjustable Dental Impression Trays (가변형 치과 인상용 트레이의 적합도에 관한 예비연구)

  • Kim, Min-Jeong;Oh, Sang-Chun;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.1
    • /
    • pp.83-93
    • /
    • 2005
  • This study was designed to investigate the fitness of adjustable dental impression trays. The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. A hundred dental students(male:50, female:50) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. The results obtained were as follows : 1. Uniform impression material thickness was achieved by controlling the width of the tray using stops and beveled guides. 2. In the upper tray, the impression material thickness was measured to be rather great showing thickness of the labial vestibule 8.3 mm and the midpalatal part 8.6 mm. 3. In the lower tray, length of the impression material of the labial vestibule of first, second premolar contact point was 7.8 mm, and thickness of the lingual part of premolars(1.8 mm) and molars(1.9 mm) showed small values. 4. In the lower tray, the impression material thickness of the buccal shelf area(0.2 mm) and the retromolar pad area(0.6 mm) was measured to be too small.

Ultrasonic methods for measuring the cortical bone thickness in bovine tibia in vitro (생체 외 조건의 소 경골에서 초음파를 이용하여 피질골 두께를 측정하기 위한 방법)

  • Lee, Kang Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.5
    • /
    • pp.557-563
    • /
    • 2022
  • The cortical bone thickness of the tibia is related to fracture risk and overall bone status. The present study aims to investigate the feasibility of two different ultrasonic methods for measuring the cortical bone thickness in bovine tibia in vitro. In the reflection technique, the tibial cortical thickness was determined from ultrasonic reflections from the periosteum and the endosteum producing specific peaks in the signal envelope. In the axial transmission technique, the tibial cortical thickness was determined from ultrasonic guided wave velocities measured along the axial direction of the tibia. The cortical bone thickness determined by using the reflection technique correlated significantly with that measured by using a caliper, with a Pearson's correlation coefficient of r = 0.97 (p < 0.0001). In contrast, the correlation coefficients for the axial transmission technique were r = 0.92 (p < 0.0001) for the first arriving signal method and r = 0.89 (p < 0.0001) for the slow guided wave method. Clinical feasibility should be demonstrated with an in vivo application to address the question whether the ultrasonic methods presented here could be useful as a screening tool for osteoporosis and potentially could be applied to other skeletal sites such as the femur and the radius.