A Preliminary Study on the Fitness of Adjustable Dental Impression Trays

가변형 치과 인상용 트레이의 적합도에 관한 예비연구

  • Kim, Min-Jeong (Department of Prosthodontics, School of Dentistry, Wonkwang University) ;
  • Oh, Sang-Chun (Department of Prosthodontics, School of Dentistry, Wonkwang University) ;
  • Dong, Jin-Keun (Department of Prosthodontics, School of Dentistry, Wonkwang University)
  • 김민정 (원광대학교 치과대학 치과보철학교실) ;
  • 오상천 (원광대학교 치과대학 치과보철학교실) ;
  • 동진근 (원광대학교 치과대학 치과보철학교실)
  • Published : 2005.06.30

Abstract

This study was designed to investigate the fitness of adjustable dental impression trays. The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. A hundred dental students(male:50, female:50) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. The results obtained were as follows : 1. Uniform impression material thickness was achieved by controlling the width of the tray using stops and beveled guides. 2. In the upper tray, the impression material thickness was measured to be rather great showing thickness of the labial vestibule 8.3 mm and the midpalatal part 8.6 mm. 3. In the lower tray, length of the impression material of the labial vestibule of first, second premolar contact point was 7.8 mm, and thickness of the lingual part of premolars(1.8 mm) and molars(1.9 mm) showed small values. 4. In the lower tray, the impression material thickness of the buccal shelf area(0.2 mm) and the retromolar pad area(0.6 mm) was measured to be too small.

Keywords

Acknowledgement

Supported by : 보건복지부

References

  1. Hichy JC, Zarb GA, Bolender CL. Boucher's Prosthodontic Treatment for Edentulous Patients. 10th ed., The C.V. Mosby Co., Louis, 1990
  2. Myers GE, Stockman DG. Factors that affect the accuracy and dimentional stability of the mercaptan rubber-base impression materials. J Prosthet Dent 1960; 10:525-535 https://doi.org/10.1016/0022-3913(60)90016-0
  3. Stackhouse JA. The accuracy of stone dies made from rubber impression materials. J Prosthet Dent 1970;24:337-386
  4. Shigeto N, Murata H, Hamada T. Evaluation of the methods for dislodging the impression tray affecting the dimensional accuracy of the abutments in a complete dental arch cast. J Prosthet Dent 1989;61:54-58 https://doi.org/10.1016/0022-3913(89)90109-1
  5. Kaloyannides TM and Christidou L. Elasticity of impression materials: Permanent deformation as a function of time. J Dent Res 1975;54:168 https://doi.org/10.1177/00220345750540011401
  6. Milward PJ, Murphy WM. Custom impression trays with a new hypoallergenic material. J Prosthet Dent 1994;72(5):572-573 https://doi.org/10.1016/0022-3913(94)90133-3
  7. Ohkubo C, Ohkubo C, Hosoi T, Kurtz KS. A sectional stock tray system for making impressions. J Porsthet Dent 2003;90:201-4 https://doi.org/10.1016/S0022-3913(03)00264-6
  8. Thongthammachat S, Moore BK, Barco MT, Hovijitra S, Brown DT, Andres CJ. Dimensional accuracy of dental casts : Influence of tray material, impression material, and time. J Prosthodont 2002;11:98-108 https://doi.org/10.1053/jpro.2002.125192
  9. Shin SJ, Park JY, Oh SC, Dong JK. A study on the fitness of dentulous stock tray designed for Korean. J Wonkwang Dental Research Institute 1997;7(1):193-209
  10. Kim JH, Chung MK. Comparison of the accuracy of stone casts made from alginate impression material by mixing methods and application of tray adhesive. J Korea Acad Proshtodont 2001;39(5):492-500
  11. Lee YC, Park YC. A study on the dental arch by occlusogram in normal occlusion. Korean Journal of Orthodontics 1987;17:279-287
  12. Song DS, Jin TH, Dong JK. A study on the fitness of stock tray in Koreaa adults. J Korea Acad Proshtodont 1989;27(2):131-140
  13. Song DS, Kang SK, Cho HW, Dong JK. Development of dentulous stock trays for Koreans. J Korea Acad Proshtodont 1996;34(4);755-778
  14. Dong JK, Oh SC, Kim MJ. Development of adjustable dental impression trays. 10th Meeting of the International College of Prosthodontists, Canada Halifax. 2003:abstract No.51
  15. Morrow RW, Brown CE, Powell JM, Rudd KD. Compatibility of alginate impression materials and dental stones. J Prosthet Dent 1971;25:556-566 https://doi.org/10.1016/0022-3913(71)90214-9
  16. Lee SH. A study on the accuracy of rubber impression materials. J Korean Dent Assoc 1983;21:237-243
  17. Hollinger JO, Lorton L, Krantz WA. Connelly M. A clinical and laboratory comparison of irreversible hydrocolloid impression techniques. J Prosthet Dent 1984;51:304-309 https://doi.org/10.1016/0022-3913(84)90209-9
  18. Kim KN. Alginate impression materials. The Korea Research Society for Dental Materials 1986;13: 27-32
  19. Izharul Haque Ansari. Making a custom tray for elastomeric impression materials without a primary cast. J Prosthet Dent 1994:72(5):569-571 https://doi.org/10.1016/0022-3913(94)90132-5
  20. Reiberg HJ. The impression tray - an important factor in impression precision. Int Dent J 1977;27:146
  21. Breeding LC, Dixon DL, Monseley JP. Custom inpression trays part 1 : Mechanical properties. J Prosthet Dent 1994;71:31-34 https://doi.org/10.1016/0022-3913(94)90252-6
  22. Ryu SI, Chang IT, Kim KN. The influence of impression trays on the accuracy of the stone casts poured from complete-arch impressions. J Korea Acad Proshtodont 1992;30:1-13