• Title/Summary/Keyword: Measuring Length

Search Result 1,167, Processing Time 0.035 seconds

AN ACCURACY OF THE SEVERAL ELECTRONIC APEX LOCATORS ON THE MESIAL ROOT CANAL OF THE MANDIBULAR MOLAR (하악 대구치 근심근관에 대한 전자근관장 측정기의 정확도)

  • Cho, Young-Lin;Son, Wook-Hee;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.6
    • /
    • pp.477-485
    • /
    • 2005
  • The aim of this study was to compare the length between the mesio-buccal and mesio-lingual canal of the mandibular molars before and after early coronal flaring at the different measuring time using several electronic apex locators. Fifty mandibular molars with complete apical formation and patent foramens were selected. After establishing the initial working length of the buccal and lingual canal of the mesial root using a surgical microscope (Carl Zeiss Co Germany) at 25X with #15 K-fle tip just visible at the foramen, radiographs were taken for the working length. After measuring the length of mesio-buccal and mesio-lingual canal (control group), the electronic lengths were measured at different times using several electronic apex locators (experimental groups; I-Root ZX, II-Bingo, III-Propex, IV-Diagnostic). After early coronal flaring using the $K^3$ file, the additional electronic lengths were measured using the same manner The results were as follows: One canal has a correct working length for the mesial root of the mandibular molar, it can be used effectively for measuring the electronic working length of another canal when the files are superimposed or encountered at the apex. In addition, the accuracy of the electronic apex locators was increased as the measurement was accomplished after the early coronal flaring of the root canal and the measuring time was repeated.

Prediction of Tool Deflection in Ball-end Milling Process (볼 엔드밀 공정에서 공구변형 예측에 관한 연구)

  • Lee Kyo-Seung;Namgung Jae-Kwan;Park Sung-Jun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.14 no.3
    • /
    • pp.8-15
    • /
    • 2005
  • A new measuring method for tool deflection has been developed when sculptured surface is processed in ball-end milling. Since the vibration due to cutting forces has low frequencies, an electromagnetic sensor is used for measuring the exact vibration displacement. The amplitude and direction of vibration displacement during the cutting process is presented as orbital plot. In this study, it assumes that the vibration displacement is proportional to the length of cutting chip. Therefore, tool deflection is calculated by summing up the vibration displacement of unit chip length for engaged chip length. In addition, computer programs has been developed to predict the deflection of tools when machining sculptured surface. This developed program predicts the tool deflection per block of NC data, so that it can easily identify the parts which have the possibility of machining errors.

Portable Calibration System for Displacement Measuring Sensors

  • Eom, Tae-Bong;Lee, Jae-Yun;Kim, Jae-Wan;Joon, Lyou
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.7 no.2
    • /
    • pp.56-59
    • /
    • 2006
  • A vibrational model of powder transfer equipment based on the lumped parameter method was developed, in which the operating motion consists of surging, bouncing, and pitching. After decoupling the equation of motion, the vibrational excitation source of the pitching motion was removed. So the designers are able to plan the optimum design to adjust the motion trajectory of the powder transfer equipment. That is, a procedure to adjust the motion trajectory of powder transfer equipment by changing design specifications such as the installation position, the direction of the motor, the driving speed, the mass unbalance, the stiffness coefficient, and the installation position of the support spring, is presented in this paper. The powder transfer equipment manufactured according to the results of this study did not suffer fatigue destruction, since the maximum stress on the basket structure was sufficiently small.

Calibration of the integrating sphere system for correcting the roughness effect in gauge block length measurement by using the Newton's rings interferometer (간섭무늬 분석을 통한 게이지 블록의 거칠기 효과 보정용 광산란장치 교정)

  • Kang C.S.;Kim J.W.;Cho M.J.;Kong H.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.47-48
    • /
    • 2006
  • A roughness measuring system which comprises an integrating sphere and a stabilized laser has been fabricated with the aim of measuring the roughness correction value which is necessary in gauge block measurement by optical interferometry. To calibrate the system, a Newton's ring interferometer has been introduced. The method how to calibrate the roughness measurement system has been described.

  • PDF

Room Acoustic Measurement System Using Impulse Response (임펄스응답을 이용한 실내음향 측정 시스템)

    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.63-67
    • /
    • 1999
  • Recently, a method of measuring impulse response is widely used for a room acoustic evaluation instead of measuring reverberation time by white noise excitation. Comparing with the traditional reverberation time measurement, this method has many advantages such as good repeatability and the ability to extract various room acoustic parameters at one measurement. In this study, the author developed a measuring system that can extract mono-aural room acoustic parameters from an impulse response measured with MLS (Maximum Length Sequence) signal excitation. These room acoustic parameters include reverberation times(EDT, RT), speech intelligibilities(C50, C80, D, U50, U80, AI) and sound strength(G). This paper introduces the configuration of the developed measuring system, test results and discussions for the measurements at several rooms.

  • PDF

Development of linear measuring system (선형측정장치 개발)

  • Eom, Tae-Bong;Kim, Goo-Young;Chung, Myung-Sai
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.10 no.4
    • /
    • pp.104-108
    • /
    • 1993
  • The linear length measurements are most frequently performed and should be most accurate among other parts in dimensional metrology. We developed the linear measuring system using a laser interferometer to improve the accuracy and to shorten the calibration time. The uncertainty of the system is 0.01 .mu. for 500mm steel gage block. The range of the measurement and resolution of the system are 1000mm and 0.01 .mu. m, respectively.

  • PDF

PLANT ROOT LENGTH DENSITY MEASUTEMENT USING IMAGE PROCESSING

  • Kim, Giyoung;David H.Vaughan
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.792-801
    • /
    • 1996
  • A thinning algorithm -based image analysis technique was developed to measure corn root lengths. The root length measurement method was evaluated by comparing thread lengths measured by the image analysis system with actual thread lengths. The length measurement method accurately estimated actual thread lengths (less than 2% calculated error). Also, a rapid root length density measurement procedure, which utilizes the above root length measurement method, was developed to estimate corn root length density without washing the roots. Root length densities estimated from the cut soil surface of core samples taken from the field were paired with the root length densities determined from washed roots from the same soil core sample. A linear relationship between these two values was expected and was found. Eliminating the root washing procedure reduces the time required for measuring corn root length density substantially.

  • PDF

The Comparison of Eye Movement in Measuring Tasks between the Underachievers and the Overachievers (측정과제에서 학습부진아와 학습우수아의 안구운동 비교)

  • Choi, Hyun-Dong;Shin, Won Sub;Shin, Dong-Hoon
    • Journal of Korean Elementary Science Education
    • /
    • v.33 no.1
    • /
    • pp.181-194
    • /
    • 2014
  • The purpose of this study was to analyze the difference between eye movements according to science achievement of elementary school students on measuring tasks. Science achievement was graded by the results of Korea national achievement test conducted in 2012. As an assessment tool to check measuring task, two measuring measure problems from TSPS(Test of Science Process Skill; developed in 1994) which were suitable for eye tracking system were adopted. The subjects of this study were 3 underachievers and 3 overachievers from 6th grade who agreed to participate in the research. SMI was used to collect EMD (eye movement data). Experiment 3.2 and BeGaze 3.2 programs were used to plan experiment and analyze EMD. As a result, eye movements of participants in measuring task did not show the path to the common gaze by groups. To solve the problem of using specific measuring strategies related to the correct answer. Underachiever who failed in measuring tasks don't have enough measurement capabilities and lack eye movement through the area of interest for cognitive thinking. These results show that elementary school science curriculum dealing with measuring have to reflect a lot of step-by-step learning requires.

Leg Length Inequality, Habitual Posture, and Pain in Women's College Students (여대생의 다리길이 차이와 생활습관 자세 및 통증)

  • Kwon, Sung-Bok;Yi, Yeo-Jin;Han, Hye-Ja;Cho, Kyung-Sook;Lim, Nan-Young;Lee, Eun-Hee;Son, Haeng-Mi;Park, Young-Sook;Kim, Joo-Hyun;Kang, Hyun-Sook
    • Journal of muscle and joint health
    • /
    • v.19 no.1
    • /
    • pp.27-36
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the leg length Inequality, habitual posture, and pain in women's college students. Methods: The subjects were 281 students, in 8 women's college in Korea. The tapelines were used for measuring leg length Inequality and questionnaires were used for measuring habitual posture, and pain. The data were collected between August and October 2010 and analyzed using SPSSWIN 11.5. length Inequality(<1 cm). The subjects of 2.8% were the length differences of above 2cm. The worst habitual posture were leaning habits. Especially, the habits of crossing her legs were significantly different to leg length Inequality(F=3.342, $p$=.037). The subjects of 84% were felt a severe pain on the upper body such as waist, back, scapula, neck or shoulder. But there is no difference between pain and leg length Inequality. Habitual posture are related to pain(r=.212, $p$=.001). Conclusion: To protect the severe health problem of musculoskeletal system, this study results will be give aid to health education in women's college students.

The Effects of Kinesio Taping on the Gait Pattern in Patients with Degenerative Arthritis (키네시오 테이핑이 퇴행성 슬관절염 환자의 보행패턴에 미치는 효과)

  • Son, Gil-Soo;Lee, Moon-Hwan;Lee, Soo-Yeon
    • Journal of Korean Physical Therapy Science
    • /
    • v.15 no.1
    • /
    • pp.57-66
    • /
    • 2008
  • This study was conducted to investigate the effects of kinesio taping in patients with degenerative arthritis. 40 female patients with degenerative arthritis were voluntarily recruited and randomly divided into experimental and control group. Experimental group(mean age was 73.4 years, height was 153.5cm, and weight was 59.9kg) was applied patellar inferior and medial gliding, quadriceps, tibial external rotation, gastrocnemius, and soleus using a kinesio tape. And control group(mean age was 72.7 years, height was 154cm, and weight was 58.6kg) was received a interferential current therapy(ENDOMED 582, Enraf-Nonius, Holland). And we received a consent form from all subjects. Measuring was conducted by using a 3-dimensional gait analysis system for measuring of stride length, cadence, and velocity. The results were as follow: Stride length was significantly increased after than before treatment(p<.05). Cadence was significantly increased after than before treatment(p<.05). And Velocity was significantly increased after than before treatment(p<.05). Cadence was a significant difference between experimental and control group(p<.05), but there was no significant difference stride length and velocity between two groups. So we suggest that kinesio taping has a effectiveness in patients with degenerative arthritis.

  • PDF