DOI QR코드

DOI QR Code

AN ACCURACY OF THE SEVERAL ELECTRONIC APEX LOCATORS ON THE MESIAL ROOT CANAL OF THE MANDIBULAR MOLAR

하악 대구치 근심근관에 대한 전자근관장 측정기의 정확도

  • Cho, Young-Lin (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Son, Wook-Hee (Department of Conservative Dentistry, College of Dentistry, Chosun University) ;
  • Hwang, Ho-Keel (Department of Conservative Dentistry, College of Dentistry, Chosun University)
  • 조영린 (조선대학교 치과대학 치과보존학교실) ;
  • 손욱희 (조선대학교 치과대학 치과보존학교실) ;
  • 황호길 (조선대학교 치과대학 치과보존학교실)
  • Published : 2005.11.01

Abstract

The aim of this study was to compare the length between the mesio-buccal and mesio-lingual canal of the mandibular molars before and after early coronal flaring at the different measuring time using several electronic apex locators. Fifty mandibular molars with complete apical formation and patent foramens were selected. After establishing the initial working length of the buccal and lingual canal of the mesial root using a surgical microscope (Carl Zeiss Co Germany) at 25X with #15 K-fle tip just visible at the foramen, radiographs were taken for the working length. After measuring the length of mesio-buccal and mesio-lingual canal (control group), the electronic lengths were measured at different times using several electronic apex locators (experimental groups; I-Root ZX, II-Bingo, III-Propex, IV-Diagnostic). After early coronal flaring using the $K^3$ file, the additional electronic lengths were measured using the same manner The results were as follows: One canal has a correct working length for the mesial root of the mandibular molar, it can be used effectively for measuring the electronic working length of another canal when the files are superimposed or encountered at the apex. In addition, the accuracy of the electronic apex locators was increased as the measurement was accomplished after the early coronal flaring of the root canal and the measuring time was repeated.

근단부위 형성이 완료되고 우식이 없는 하악 대구치 근심치근 50개를 대상으로 주파수 의존형 전자근관장 측정기를 이용하여 측정한 근관장의 정확도를 평가하기 위해 치수강 개방 후 동일한 치아에서 방사선 사진으로 확인한 실측 근관장을 대조군, 각종 전자근관장 측정기로 측정한 근관장을 실험군 ( I군: Root-ZX, II군: Bingo, III군: Propex, IV군: Diagnostic)으로 분류하여 근심협측과 설측의 근관장을 근관의 입구 측으로부터 치근단 1/3까지 확대여부 및 서로 다른 측정시기에 측정하여 비교 평가한 결과 다음과 같은 결론을 얻었다. 하악대구치 근심치근의 협측과 설측 전자근관장은 측정기의 종류, 근관의 입구 측으로부터 치근단 1/3까지의 확대여부 및 측정시기에 상관없이 0.5mm이내의 오차범위를 나타내었으며, 근관치료시 오차한계인 ${\pm}1mm$에서 정확성은 근관의 입구 측으로부터 치근단 1/3까지 미리 확대한 후에 근관장을 측정할 경우와 측정시기가 반복될 경우에 증가되는 경향을 보여 임상에 유용하게 활용할 수 있을 것으로 사료된다.

Keywords

References

  1. Seltzer S, Bender I, Turkenkopf S. Factors affecting successful repair after RCT. J Am Dent Assoc 67:651-662, 1963 https://doi.org/10.14219/jada.archive.1963.0349
  2. Seltzer S, Soltanoff W, Smith J. Periapical tissue reactions of root canal instrumentation beyond the apex. Oral Surg Oral Med Oral Pathol 36:275-377, 1973
  3. Sjogren U. Factors affecting the long-term results of endodontic treatment. J Endod 16:498-504, 1990 https://doi.org/10.1016/S0099-2399(07)80180-4
  4. Strindberg L. The dependence of pulp therapy on certain factors: an analytic study based on radiographic and clinical follow-up examinations. Acta Odontol Scand 14:1, 1956
  5. Swartz DB, Skidmore AE, Griffin JA, Jr. Twenty years of endodontic success and failure. J Endod 9:198-202, 1983 https://doi.org/10.1016/S0099-2399(83)80092-2
  6. Kuttler Y. Microcopic investigation of root apexes. J Am Dent Assoc 50:544-552, 1955 https://doi.org/10.14219/jada.archive.1955.0099
  7. Altman M, Guttuso J, Seidberg BH, Langeland K. Apical root canal anatomy of human maxillary central incisors. Oral Surg Oral Med Oral Pathol 30:694-699, 1970 https://doi.org/10.1016/0030-4220(70)90396-8
  8. Burch JG, Hulen S. The relationship of the apical foramen to the anatomic apex of the tooth root. Oral Surg Oral Med Oral Pathol 34:262-267, 1972 https://doi.org/10.1016/0030-4220(72)90418-5
  9. Green D. A stereomicroscopic study of the root apices of 400 maxillary and mandibular posterior teeth. Oral Surg Oral Med Oral Pathol 9:1224-1232, 1956 https://doi.org/10.1016/0030-4220(56)90192-X
  10. Green D. Stereomicroscopic study of 700 root apices of maxillary and mandibular posterior teeth. Oral Surg Oral Med Oral Pathol 13:728-733, 1960 https://doi.org/10.1016/0030-4220(60)90373-X
  11. Goldmann M, Pearson AH, Darzenta N. Reliability of radiographic interpretations. Oral Surg Oral Med Oral Pathol 38:287-293, 1974 https://doi.org/10.1016/0030-4220(74)90070-X
  12. Suzuki K. Experimental study on iontophoresis. J Jpn Stomatol 16:411-417, 1942 https://doi.org/10.5357/koubyou1927.16.6_411
  13. Sunada I. New method for measuring working lengths of root canal. J Dent Res 42:375-378, 1962
  14. Huang L. An experimental study of the principle of electronic root canal measurement J Endod 13:60-64, 1987 https://doi.org/10.1016/S0099-2399(87)80156-5
  15. Seidberg BH, Alibrandi BV, Fine H, Logue B. Clinical investigation of measuring working lengths of root canals with an electronic device and with digital-tactile sense. J Am Dent Assoc 90:379-387, 1975 https://doi.org/10.14219/jada.archive.1975.0059
  16. Fouad AF, Krell KV, McKendry DJ, Koorbusch GF, Olson RA. Clinical evaluation of five electronic root canal length measuring instruments. J Endod 16:446-449, 1990 https://doi.org/10.1016/S0099-2399(06)81889-3
  17. Kobayashi C, Suda H. New Electronic canal length measuring device on the ratio method. J Endod 20:111-114, 1994 https://doi.org/10.1016/S0099-2399(06)80053-1
  18. Shabahang S, Goon WWY, Gluskin AH. An in vivo Evaluation of Root ZX Electronic Apex Locator. J Endod 22:616-618, 1996 https://doi.org/10.1016/S0099-2399(96)80033-1
  19. Caldwell JL. Change in working length following instrumentation of molar canals. Oral Surg Oral Med Oral Pathol 41:114-118, 1976 https://doi.org/10.1016/0030-4220(76)90260-7
  20. Stabholz Q, Rotstein I, Torabinejad M. Effect of preflaring on tactile detection of the apical constriction. J Endod 21:92-94, 1995 https://doi.org/10.1016/S0099-2399(06)81103-9
  21. Gutierrez JH, Aguayo P. Apical foraminal openings in human teeth. Oral Surg Oral Med Oral Pathol Oral Radial Endod 79:769-777, 1995 https://doi.org/10.1016/S1079-2104(05)80315-4
  22. Skidmore AE, Bjorndal AM. Root canal morphology of the human mandibular first molar. Oral Surg Oral Med Oral Pathol 32:778-784, 1971 https://doi.org/10.1016/0030-4220(71)90304-5
  23. Pineda F, Kuttler Y. Mesiodistal and buccolingual roentgenographic investigation of 7225 root canals. Oral Surg Oral Med Oral Pathol 33:101-110, 1972 https://doi.org/10.1016/0030-4220(72)90214-9
  24. Green D. Morphology of the pulp cavity of the permanent teeth. Oral Surg Oral Med Oral Pathol 8:743-759, 1955 https://doi.org/10.1016/0030-4220(55)90039-6
  25. Wheeler RC. Dental Anatomy, Physiology and Occlusion. 5th. ed. W.B. Saunders Co., 1974. 267-297
  26. Woelfel JG, Scheid RC. Dental Anatomy. 1st. ed. philadelphia, Williams & Wilkins, 2002, p97-107
  27. Katz A, Tamse A, Kaufman AY. Tooth length determination: a review. Oral Surg Oral Med Oral Pathol 72:238-242, 1991 https://doi.org/10.1016/0030-4220(91)90169-D
  28. Seltzer S, Soltanoff W, Smith J. Biologic aspects of endodontics. V. Periapical tissue reactions to root canal instrumentation beyond the apex and root canal fillings short of and beyond the apex. Oral Surg Oral Med Oral Pathol 36:725-737, 1973 https://doi.org/10.1016/0030-4220(73)90146-1
  29. Kim BH, Lee YK, Kim YS. A study on the accuracy of the ROOT-ZX in the canal with mechanically formed constriction. J Kor Acad Cons Dent 24:628-632, 1999
  30. Czerw RJ, Fulkerson MS, Donnelli JC. An in vitro test of simplified model to demonstrate the operation of electronic root canal measuring devices. J Endod 20:605-606, 1994 https://doi.org/10.1016/S0099-2399(06)80086-5
  31. Cohen S, Burns R. Pathways of the pulp. 7th ed. St. Louis:CV Mosby, 1998, p248-251
  32. Kang DH, Chung KH, Yoon SH, Bae KS. An in vitro evaluation of the accuracy of Root ZX electronic apex locator. J Kor Acad Cons Dent 23:339-345, 1998
  33. Park JH, Roh BD, Lee SJ. The accuracy of the frequency dependent type apex locator. J Kor Acad Cons Dent 21:150-160, 1996
  34. Kim HJ, Hong CU. In vivo evaluation of accuracy of two electronic apex locators. J Kor Acad Cons Dent 21:289-299, 1996
  35. Czerw RJ, Fulkerson MS, Donnelly JC, Walmann JO. In vitro evaluation of the accuracy of several electronic apex locators. J Endod 21:572-575, 1995 https://doi.org/10.1016/S0099-2399(06)80988-X
  36. Dunlap CA, Remeikis NA, BeGole EA, Rauschenberger CR. An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals. J Endod 24:48-50, 1998 https://doi.org/10.1016/S0099-2399(98)80214-8
  37. Frank AL, Torabinejad M. An in vivo evaluation of endex electronic apex locator. J Endod 19:177-179, 1993 https://doi.org/10.1016/S0099-2399(06)80683-7
  38. Lauper R, Lutz F, Barbakow F. An in vivo comparison of gradient and absolute impedance electronic apex locators. J Endod 22:260-263, 1996 https://doi.org/10.1016/S0099-2399(06)80145-7
  39. Ounsi HF, Haddad G. In vitro evaluation of the reliability of the Endex electronic apex locator. J Endod 24:120-121, 1998 https://doi.org/10.1016/S0099-2399(98)80090-3
  40. Pagavino G, Pace R, Baccetti T. A SEM study of in vivo accuracy of the Root ZX electronic apex locator. J Endod 24:438-441, 1998 https://doi.org/10.1016/S0099-2399(98)80029-0
  41. Hwang HK, Shin YG, Kim PS. A study on the accuracy of the Root-ZX according to the various conditions of root canals. J Kor Acad Cons Dent 25:474-481, 2000
  42. Hwang HK, Shin YG. The effectiveness of obturating techniques in sealing isthmuses. J Kor Acad Cons Dent 26:499-506, 2001

Cited by

  1. Study of endodontic working length of Korean posterior teeth vol.35, pp.6, 2010, https://doi.org/10.5395/JKACD.2010.35.6.429
  2. An evaluation of the accuracy of Root ZX according to the conditions of major apical foramen vol.37, pp.2, 2012, https://doi.org/10.5395/rde.2012.37.2.68