• Title/Summary/Keyword: Measurement of association

Search Result 3,899, Processing Time 0.032 seconds

Measurement Uncertainty for Analytical Method of Hyaluronic Acid Used as a Dietary Supplement (식이보충제로 사용되는 히알루론산의 분석법에 대한 불확도 산정)

  • Park, Sang-Wook;Kim, Hyung Bum;Kim, Kwang Joon;Lee, Wonjae
    • KSBB Journal
    • /
    • v.32 no.1
    • /
    • pp.54-62
    • /
    • 2017
  • This study aimed to estimate the measurement uncertainty related to determination of hyaluronic acid used as a dietary supplement by high-performance liquid chromatography. According to the guidelines of the Association of Official Analytical Chemists, the analytical processes for determination of hyaluronic acid were performed. And the measurement uncertainty obtained during the analytical processes were expressed in accordance with mathematical/ statistical guidances of GUM (Guide to the Expression of Uncertainty in Measurement) & EURACHEM (Focus for Analytical Chemistry in Europe) for the analytical operations. For the uncertainty in measurement produced based on this analytical method, the expanded uncertainty was calculated by using the relative standard uncertainty between analytical results and sources of uncertainty in measurement (sample weight, final volume, extraction volume, standard solution, matrix and instrument etc). In the results of 95% confidence interval, it was calculated that the uncertainty in measurement was $57.75{\pm}8.76{\mu}g/kg$ (k=2.0). Therefore, it showed that the measurement uncertainty obtained by this analytical method influences on 15.2% of the contents of hyaluronic acid as the analytical results.

Development of the Nursing Process Based Performance Measurement Tool for Medication Management and Blood Transfusion (투약과 수혈간호의 간호과정 적용 평가도구 개발)

  • Kim, Keum Soon;Kim, Jin A;Kwon, So Hi;Song, Mal Soon
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.1
    • /
    • pp.177-196
    • /
    • 2010
  • Purpose: This study was conducted to develop the nursing process based performance measurement tool and the evidence based care standards for nursing care in medication management and blood transfusion. Methods: The care standards and performance measurement tool were drafted through comprehensive review of relevant literature, national guidelines, hospital protocols, and standards of recognized international accrediting bodies. The proposed care standards and performance measurement tool were reviewed by the panel of experts and refined based on the panel's suggestions. Final care standards and performance measurement tool were validated by surveying the hospital nurses. Results: All items of the performance measurement tool for medication management and blood transfusion were evaluated appropriate. All contents of care standards and the measurable elements except the evaluation of discharge education were appropriate. The performance measurement tool developed in this study was found to be acceptable as a tool to evaluate quality of nursing care in medication management and blood transfusion. Conclusion: The outcomes of this study including the performance measurement tool and evidence based care standards would be the important indicators to monitor whether necessary nursing care is implemented and be the useful primary resources to improve quality of nursing care services.

Principles and Comparative Studies of Various Power Measurement Methods for Lithium Secondary Batteries (리튬이차전지 출력측정법의 원리 및 측정법간 비교 연구)

  • Lee, Hye-Won;Lee, Yong-Min
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.3
    • /
    • pp.115-123
    • /
    • 2012
  • As the market of lithium secondary batteries moves from mobile IT devices to large-format electric vehicles or energy storage systems, the strengthened battery specifications such as long-term reliability longer than 10 years, pack-level safety and tough competitive price have been required. Moreover, even though high power properties should also be achieved for hybrid electric vehicles, it is not easy to measure accurate power values at various conditions. Because it is difficult to choose a proper measurement method and its experimental condition is more complex comparing to capacity measurement. In addition, the power values are very sensitive to power duration time, state-of-charge (SOC) of cells, cut-off voltages, and temperatures, whereas capacity values are not. In this paper, we introduce three kinds of power measurement methods, hybrid pulse power characterization (HPPC) suggested by US FreedomCar, so-called J-pulse by Japan electric vehicle association standards (JEVS) and constant power measurement, respectively. Moreover, with pouch-type unit cells for HEV, experimental power data are discussed in order to compare each power measurement.

Development of an Analysis Software for the Load Measurement of Wind Turbines (풍력발전기의 하중 측정을 위한 해석 소프트웨어의 개발)

  • Gil, Kyehwan;Bang, Je-Sung;Chung, Chinwha
    • Journal of Wind Energy
    • /
    • v.4 no.1
    • /
    • pp.20-29
    • /
    • 2013
  • Load measurement, which is performed based on IEC 61400-13, consists of three stages: the stage of collecting huge amounts of load measurement data through a measurement campaign lasting for several months; the stage of processing the measured data, including data validation and classification; and the stage of analyzing the processed data through time series analysis, load statistics analysis, frequency analysis, load spectrum analysis, and equivalent load analysis. In this research, we pursued the development of an analysis software in MATLAB to save labor and to secure exact and consistent performance evaluation data in processing and analyzing load measurement data. The completed analysis software also includes the functions of processing and analyzing power performance measurement data in accordance with IEC 61400-12. The analysis software was effectively applied to process and analyse the load measurement data from a demonstration research for a 750 kW direct-drive wind turbine generator system (KBP-750D), performed at the Daegwanryeong Wind Turbine Demonstration Complex. This paper describes the details of the analysis software and its processing and analysis stages for load measurement data and presents the analysis results.

The Evaluation Tool and Process for Effective Education Outcomes Measurement and Analysis of Computer Education

  • Kim, Young-Tak;Sim, Gab-Sig
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.9
    • /
    • pp.149-156
    • /
    • 2016
  • This paper is concerned with education courses operating practices for basic computer literacy training. In this study, we propose an example for students to effectively measure and evaluate the achievement of defined ability in the performance measurement and analysis, learning objectives and learning outcomes set in operation throughout the course. Through research and development use case presents the tools for teaching method and effective and objective measurement of the related subjects. And based on the results, we propose the possibility of utilizing NCS-based course operation and education certification. In this study, the measurement process is based on the association with the objective of the development and operation, and measurement tools, measuring tools for measuring learning outcomes associated with the curriculum design methods for the measurement and evaluation of the case of the operation of the course units of learning outcomes and the method proposed.

A Study on the Plan Photogrammetry for Clothing Design (피복구성학적 인체계측방법에 관한 연구 - 평면사진계측방법을 중심으로 -)

  • 박찬미;서미아
    • The Research Journal of the Costume Culture
    • /
    • v.5 no.1
    • /
    • pp.151-164
    • /
    • 1997
  • This study pursues the problems of plan photogrammetry which is widely used in somatotyping at present, and find out a method which can improve accuracy of measurement on the basis of principles and mechanisms of photography-the basic foundation of the photographic analysis methods. As a result, this study proposes a new method which is based on the reference point method and perspective coordinate system. And the test measurement was operated to compare the measurement accuracy of the proposed method and the method based on reference grid screen method and perpendicular coordinate system which is commonly used at present. The result of this test measurement showed that the proposed method has higher accuracy. Two reasons can be pointed out for the improvement of measuring accuracy. The first reason is that the proposed perspective coordinate system reduces the perspective distortion of photography. And second reason is that measuring points can be closely placed to the scale and coordinate reference plan of measurement by the proposed reference point method which make possible to place measuring object (or person) at the center of scale and coordinate reference plan by utilizing reference points of measurement in the three dimensional space not on screen.

  • PDF

Ultrafine Particle Toxicities, Current Measurement Techniques and Controls (Ultrafine Particle의 독성, 측정방법 및 관리)

  • Lee, Su-Gil;Kim, Seong-Soo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.3
    • /
    • pp.203-215
    • /
    • 2010
  • This study is an overview of toxicities and measurement techniques of ultrafine particles (UFPs), and their exposure controls. UFPs are ubiquitous in many working situations. Exposure to UFPs is possibly causing adverse health symptoms including cardio-respiratory disease to humans. In order to measure exposure levels of airborne UFPs, there are current available measurement guidelines, instruments and other techniques (i.e. contour mapping, control banding). However, these risk assessment techniques including measurement techniques, controls and guidelines are dependent on background levels, metrics (e.g. size, mass, number, surface area, composition), environmental conditions and controls. There are no standardized measurement methods available and no generic and specific occupational exposure standards for UFPs. It is thought that there needs to be more effort to develop Regulations and Exposure Standards for generic UFPs should be based on more exposure data, health surveys, toxicological data and epidemiological data. A carefully considered hierarchy of controls can also reduce the maximum amount of airborne UFPs being emitted from diverse sources in industries.

The Effects of Estimation Activities on Operation and Measurement Abilities of Children (어림하기 활동이 유아의 수 연산과 측정 능력에 미치는 효과)

  • Chung, Chung-Hee;Choi, Hyo-Jung;Kwon, Mi-Jung
    • Korean Journal of Child Studies
    • /
    • v.30 no.1
    • /
    • pp.109-125
    • /
    • 2009
  • This study examined the effects of estimation activities on children's operation and measurement abilities. Subjects were 60 five-year-old children. This experiment used the untreated control group design with pretest and posttest. Instruments used to collect data were the Number and Operation and Measurement tests part of the Test of Mathematics Ability for Young Children (TMAYC) developed by Hong, Lee and Chung (2006). ANCOVA was employed for statistical analysis. Results of the posttest showed that children in the experimental group scored significantly higher on children's operation and measurement abilities than the control group. Results imply that an estimation program can be an effective teaching model for improving children's operation and measurement abilities.

  • PDF

A Study for Implementation of Density Measurement Equipment for Asphalt Pavement based on the electromagnetic capacitance

  • Park, Young-Ho;Kim, Gun-Kyun;Nor, Jeong-Keun;Ha, Jae-Kwon
    • International Journal of Contents
    • /
    • v.6 no.4
    • /
    • pp.39-42
    • /
    • 2010
  • In this paper we developed density measurement equipment for Asphalt Pavement based on the electromagnetic capacitance. This kind of Non-Nuclear Density Gauges technology and products is used or studied in USA, Finland, Sweden as standardization of authorized method for pavement density measurement. Effective permitivity of pavement asphalt is characterized in electromagnetic capacitance by the asphalt material, mixed ratio, and harden grade of pavement asphalt. We can get a density value of asphalt by replacing value of electromagnetic capacitance with standard density value and characteristic transformation curve. We are conformed that measurement data according to temperature, humidity, and real field asphalt of our density measurement equipment can be a precise value.