• 제목/요약/키워드: Measurement Table

검색결과 453건 처리시간 0.028초

체온측정에 필요한 최단적정시간규명을 위한 실험적 연구 (An Experimental Study on the Shortest optimum time for Body Temperature measurement)

  • 홍여신;이선옥
    • 대한간호학회지
    • /
    • 제5권2호
    • /
    • pp.38-50
    • /
    • 1975
  • This study was conducted to find the shortest optimum time for taking oral temperature and axillary temperature, which does not affect reliability of body temperature. For this purpose, first, the time at which all the samples are reaching maximum temperature is identified Second, the mean maximum temperature is compared with the mean temperature of each consecutive measurement by T-test to find the time at which no significant changes in temperature occurs along time sequence. Third, optimum temperatures are set at points of -0.2℉, -0.4℉, -0.6℉, -0.8℉, -1.0℉, -1.2℉, -1.4℉, from maximum temperature. A point of time at which 90% of samples reach at optimum temperature is identified and defined as optimum time. The study sample, a total of 164 cases were divided into two groups according to their measured body temperature. The group with body temperature below 37 $^{\circ}C$(A group) and above 37$^{\circ}$1'C (B group) were compared on the time required to reach maximum temperature and optimum temperature. The results are as follow. 1. The time required for total sample to reach maximum temperature was 13 minutes in both groups by oral method, 15 minutes in A group and 13 minutes in B group by axillary method. Time required for 90 % of cases reach maximum temperature by oral method was 10 minutes in both group. By axillary method, 12 minutes in A group. (Ref: table 2) 2. Statistical analysis by means of T-test, the time which does not show a significant change by oral method were 12 minutes in A group and 11 minutes in B group, and by axillary method 14 minutes in A group and 11 minutes in B group. (Ref: table 5, 6.) 3. Where optimum temperature was defined as maximum temperature minus 0.2 ℉, optimum time was found 8 minutes in both groups by oral method, and 11 minutes in A group and 9 minutes in B group by axillary method 4. Where optimum temperature was defined as maximum temperature minus 0.4 ℉, optimum time was found 7 minutes in A group and 6 minutes in B group by oral method, and 9 minutes in A group and 7 minutes in B group by axillary method 5. Where optimum temperature was defined as maximum temperature minus 0.8 ℉, optimum time was found 6 minutes in A group and 6 minutes in B group by axillary method (Ref: table 7, 8, 9, 10) 6. The commonly practiced temperature taking time, 3 minutes in oral method and 5 minutes in axillary method can be accepted as pertinent when physiological variation of body temperature at the mean level of -1, 2 ℉ is accepted. 7. The difference in time required to resister maximum temperature was compared between the group with body temperature below 37$^{\circ}C$ and above 37$^{\circ}$1'C, and found no significant difference in oral mettled and 1 - 4 minute difference in axillary method with shorter time requirement in feverish group.

  • PDF

건설기계 시간당작업량(Q) 산정 개선방안 -펌프준설선 작업효율(E)을 중심으로- (The estimating method of construction workable-quantity per unit time - Focused on Pump-Dredge -)

  • 안방률;태용호;서상욱
    • 한국건설관리학회논문집
    • /
    • 제11권3호
    • /
    • pp.125-133
    • /
    • 2010
  • 국내 공공건설공사 예정가격작성기준에서 제시하는 건설기계의 시간당 작업량(Q)의 중요한 부분을 차지하는 작업효율(E)은 현장여건 등에 따라 차이가 발생하기 때문에 적용기준이 명확해야 한다. 그러나 국내 기준은 정성적인 표현이 사용되며, 이를 판단할 수 있는 기준 또한 포괄적이고 모호하여 설계자의 주관적이고 자의적인 판단에 따라 설계가 이루어지고 있는 실정이다. 본 연구에서는 펌프준설선을 대상으로 국내 외 관련 문헌조사 및 현장실사를 통하여 합리적인 작업효율(E) 제시방법을 제안하고 이로 인해 건설기계의 시간당 작업량 산정방법을 개선하고자 하였다. 문헌조사를 통해 국내기준 또한 일본기준의 형태로 작업효율(E)을 공사구분별, 흙두께, 평면형상, 단면형상, 해상조건 등으로 세분화 시킬 것을 제시하였으며, 이를 판단할 수 있는 기준도 객관화 시킬 수 있는 형태로 개선되어야 할 것을 제시하였다. 또한, 현장조사를 통해 얻어진 산출량을 일본의 예정가격작성기준을 적용하여 계산된 산출량과 비교하여 일본기준의 적정성을 검토하였다. 펌프준설선 (4,476kW)은 배송거리 3,600~6,000m의 시간당 준설량(Q)을 실측하여 표준값인 전동환산(q)을 비교하여, 일본대비 102.3% 수준으로 거의 유사한 결과값을 얻었다. 본 연구를 통해 제시된 각종 자료 및 수치들은 건설기계와 기술의 급속한 발전을 예정가격작성기준에 적용할 수 있는 기초가 될 수 있을 뿐 아니라, 관련 연구의 토대가 될 수 있으리라 기대한다.

축차 2점법을 이용한 회전체의 진원도 프로파일 측정에 관한 연구 (A Study on the Measurement of Roundness Profile for Rotating Object Using Two Points in Succession Measuring Method)

  • 이민기;이응석
    • 대한기계학회논문집A
    • /
    • 제34권8호
    • /
    • pp.1029-1034
    • /
    • 2010
  • 본 논문은 회전체의 진원도 및 흔들림 정밀도 측정에 관한 연구이다. 일반적으로 가공물 진원도 측정은 정밀한 회전테이블 또는 기준 원형 디스크를 필요로 하여, 고가의 비용이 소요된다. 축차2점법은 2개의 변위센서를 사용하여 직선가이드 등에서진직도 측정을 위하여 사용되었으며, 본 연구에서는 이 방법을 회전체에 적용하였다. 한 개의 디스크를 이용하여 측정된 회전체 변위 측정값에서 장치의 회전시 흔들림 오차를 제거하여 회전체의 순수한 진원도 프로파일을 측정하였다. 본 연구는 정밀한 기준 디스크 (Artifact)를 사용하지 않고 원형 가공물의 진원도 프로파일 측정에 유용할 것이다.

작업환경측정 보고제도 개선 방안 도출을 위한 조사 연구 (An investigation on the Improvement of the Working Environment Measurement Reporting Policy)

  • 임대성;김치년;이승길;박정근;김기연
    • 한국산업보건학회지
    • /
    • 제32권2호
    • /
    • pp.172-181
    • /
    • 2022
  • Objectives: In order to reduce the burden on employers and increase the reliability of measurement results, improvements to the provisions related to the work environment measurement reporting system, such as the current Occupational Safety and Health Act and its Enforcement Rules, are planned. This study aimed to suggest improvements for the work environment measurement reporting system through a survey and Delphi investigation. Method: This survey included workplaces (health managers), national institutions (the Ministry of Employment and Labor) that use the results of the work environment measurement reporting system for policy and supervision purposes, and work environment measurement institutions that enter the results were included. In addition to the survey, we tried to derive results through meetings with stakeholders and expert advisory meetings. Results: It is difficult to abolish or partially improve the reporting system under the Enforcement Regulations of the Occupational Safety and Health Act at this point because the opinions of workplaces, supervisory agencies, and measuring agencies differ in terms of its intended purpose and use. In the case of high-exposure harmful factors (over 50% on the basis of exposure) in the "comprehensive opinion" described in the work environment measurement results table, it is necessary to insert unit of work with exposed harmful factors, exposure factors, and current conditions in checklists or tables so that they can be reflected in government policies. In the case of workplaces that are feared to be highly exposed to substances subject to measurement, it seems desirable to improve them so that industrial health instructors registered with the Korea Safety and Health Agency or local labor offices can provide technical guidance. As an improvement plan to increase the reliability of data and the use of big data, it is necessary to improve the input method for processes and jobs. Conclusion: The laws and regulations of the work environment measurement reporting system are difficult to revise due to a lack of consensus among current stakeholders, but improvements can be achieved by improving the Ministry of Employment and Labor's notifications and other means. In addition, in order to effectively utilize the data from the K2B system, it is necessary to improve the input method for processes and jobs.

타이타늄 임플랜트 시편 내부에 설치한 자석의 자성강도에 따른 골형성 변화 (THE CHANGE OF BONE FORMATION ACCORDING TO MAGNETIC INTENSITY OF MAGNET PLACID INTO TITANIUM IMPLANT SPECIMENS)

  • 황윤태;이성복;최대균;최부병
    • 대한치과보철학회지
    • /
    • 제43권2호
    • /
    • pp.232-247
    • /
    • 2005
  • Purpose. The purposes of this investigation were to discover the possibility of clinical application in the areas of dental implants and bone grafts by investigating the bone formation histologically around specimen which was depending on the intensity of magnetic field of neodymium magnet inside of the specimens. Material and method. 1. Measurement of magnetic intensity - placed the magnet inside of the specimen, and measured the intensity of magnetic field around the 1st thread and 3rd thread of specimen 20 times by using a Gaussmeter(Kanetec Co., Japan). 2. Surgical Procedure - Male rabbit was anesthetised by constant amount of Ketamine (0.25ml/kg) and Rompun (0.25ml/kg). After incising the flat part of tibia, and planted the specimens of titanium implant, control group was stitched without magnet, while experimental groups were placed a magnedisc 500(Aichi Steel Co., Japan) or magnedisc 800(Aichi Steel Co., Japan) into it, fixed by pattern resin and stitched. 3. Management after the surgery - In order to prevent it from the infection of bacteria and for antiinflammation, Gentamycin and Ketopro were injected during 1 week from operation day, and dressed with potadine. 4. Preparation of histomorphometric analysis - At 2, 4 and 8 weeks after the surgery, the animals were sacrificed by excessed Ketamine, and then, specimens were obtained including the operated part and some parts of tibia, and fixed it to 10% of PBS buffer solution. After embedding specimens in Technovit 1200 and B.P solution, made a H-E stain. Samples width was 75$\mu$m . In histological findings through the optical microscope and using Kappa image base program(Olympus Co. Japan), the bone contact ratio and bone area ratio of each parts of specimens were measured and analyzed. 5. Statistical analysis - Statistical analysis was accomplished with Mann Whitney U-test. Results and conclusion. 1. In histomorphometric findings, increased new bone formation was shown in both control & experimental groups through the experiment performed for 2, 4 & 8 weeks. After 4 weeks, more osteoblasts and osteoclasts with significant bone remodeling were shown in experimental groups. 2. In histomorphometric analysis, the bone contact ratios were 38.5% for experimental group 1, 29.5% for experimental group 2 and 11.9% for control group. Experimental groups were higher than control group(p<0.05) (Fig. 6, Table IV). The bone area ratios were 60.9% for experimental group 2, 46.4% for experimental group 1 and 36.0% for control group. There was no significantly statistical difference between experimental groups and control group(p<0.05) (Fig. 8, Table VII) 3. In comparision of the bone contact ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group at the 1st thread (p<0.05) and experimental group 1 (1.8mT) was higher than control group at the 3rd thread(p<0.05) (Fig. 7, Table V, VI). 4. In comparision of the bone area ratios at each measurement sites according to magnetic intensity, experimental group 2(5.6mT) was higher than control group and experimental group 1 (4.0mT) at the 1st thread(p<0.1) and experimental group 2(4.4mT) was higher than experimental group 1 (1.8mT) at the 3rd thread(p<0.1) (Fig. 9, Table IX, X). Experiment group 2 was largest, followed by experiment group l and control group at the 3rd thread of implant. There was a significant difference at the 1st thread of control group & experiment group 2, and at 1st thread & 3rd thread of experiment group 1 & 2, and not at control group experiment group 1.(p<0.1)

구조 및 기능 진단을 토대로 한 IoT네트워크 핵심품질 매트릭스 모델 연구 (A Study of Matrix Model for Core Quality Measurement based on the Structure and Function Diagnosis of IoT Networks)

  • 노시춘;김점구
    • 융합보안논문지
    • /
    • 제14권7호
    • /
    • pp.45-51
    • /
    • 2014
  • IoT시스템 품질확보를 목표로 하는 QoS 관리체계에서 가장 중요한 포인트는 품질 측정체계 설계와 품질평가 제도이다. 본 연구는 IoT시스템 구조와 기능 진단을 토대로 한 핵심품질 측정용 매트릭스 모델 연구이다. 특히 사물인터넷(IoT) 환경의 품질측정에 대한 메트릭스를 개발함으로써 사물 인터넷(IoT) 품질 측정/분석을 위한 기초를 제공한다. IoT시스템 품질평가용 매트릭스는 기능적 요구사항과 품질 요구사항을 하나의 통합 테이블에 기술하여 품질평가를 시행하는 방법이다. 기능적 요구사항과 품질 요구사항을 종합하여 연관성을 평가함으로써 평가 신뢰도와 활용성을 높일 수 있다. 제안된 방법 적용 시 IoT 품질은 신호처리, 프로세싱, 네트워킹 기능 등에서 보다 효율적인 품질확보의 토대가 되고 전체적으로 지연을 줄이면서 QoS를 향상 시킬 수 있다.

우리 나라 암질환으로 인한 조기사망의 질병부담 (Measuring the Burden of Major Cancers due to Premature Death in Korea)

  • 김용익;김창엽;장혜정;윤석준
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권2호
    • /
    • pp.231-238
    • /
    • 2000
  • Objective : To estimate the burden of diseases in Korea especially caused by major cancers using the YLL(years of life lost due to premature death) measurement. Methods : First, we determined the parameters: such as age-specific standard life expectancy, age on death, sex, cause of death by analyzing the national death certificate data and life table collected during 1996 provided by the National Statistical Office. Secondly, we estimated the age group-specific YLL by employing standard expected years of life lost(SEYLL). Thirdly, final burden of disease due to premature death was estimated by using YLLs measurement which developed by global burden of disease study group. Results : The burden of premature death by cancer for male was attributed mainly to liver cancer(514.5 person-year), stomach cancer(436.4 person-year), and lung cancer(367.7 person-year). Each of these cancers was responsible for the loss of over 100 person-year based on our YLL measurement. The burden of premature death by cancer for female was attributed mainly to liver cancer(135.1 person-year), stomach cancer(252.1 person-year), and lung cancer(121.8 person-year). Each of these cancers was responsible for the loss of over 100 person year based on our YLL measurement. Conclusion : We found the YLL method employed in this study was appropriate to quantify the burden of premature death. Thereby, it would provide a rational bases to plan a national health policy regarding premature death caused by cancer.

  • PDF

차량 진동이 궤도 선형 측정에 미치는 영향 (Influence of Vehicle Vibration on Track Geometry Measurement)

  • 배규영;용재철;김이현;권삼영
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.644-650
    • /
    • 2016
  • Track maintenance works based on track geometry recordings are essential to enhance the safety and comfort of railway transportation. Usually, the track irregularity has been measured by a special inspection trains which all were imported from abroad. Because the inspection train speed is limited under 160 km/h, it takes a long time to inspect railways and there is difficulty in daytime operation. To solve this problem, we started to develop a track geometry measuring system (TGMS) with measurement speed up to 300 km/h which can be installed in commercial vehicles such as HEMU-430X. In this paper, we introduce a newly developed inertial TGMS and propose two inertial navigation system (INS) algorithms (method A, B) for measuring track geometry. In order to investigate advantage and disadvantage of each algorithm, we performed vibration test of the TGMS, which was simulated by 6-axis shaking table. Through the vibration test, we analyzed the influence of vehicle vibration on the TGMS which will be installed on bogie frame. To the vibration test, two methods satisfied the required accuracy of track geometry measurement under the level of the actual vehicle vibration of HEMU-430X train. Theoretically, method A is sensitive to vehicle vibration than method B. However, HEMU-430X's bogie vibration frequency range is out of interest range of measurement system. Therefore, method A can also apply the HEMU-430X train.

지반 오염도 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가 (Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination)

  • 오명학;김용성;박준범
    • 한국지반공학회논문집
    • /
    • 제22권7호
    • /
    • pp.45-54
    • /
    • 2006
  • 전기비저항콘은 현장에서 지반의 오염대를 조사하는데 상대적으로 경제적인 비용으로 적용될 수 있다. 그러나, 전기비저항 결과만에 의한 해석은 정량적 데이터베이스의 부족과 함수비 등의 다른 지반공학적 영향인자들에 의해 모호한 결과를 나타낼 수 있다. 본 연구에서는 지반오염조사에서의 전기비저항 측정기법을 보완하기 위하여 정전용량 측정기법을 도입하여 중금속과 유류로 오염된 지반에서의 적용성을 평가하고자 하였다. 함수비와 오염물질의 종류에 따른 전기비저항과 정전용량의 변화를 평가하기 위하여 실내모형시험을 수행하였으며, 그 결과 전기비저항과 유전상수를 통시에 측정하여 분석함으로써 오염대의 감지에 신뢰도를 높일 수 있는 것으로 나타났다. 전기비저항과 정전용량 측정기법은 중금속으로 오염된 포화지반과 지하수대 상부에 존재하는 디젤유 오염층을 감지하는 데 적용성이 높은 것으로 나타났다.

디지털 심혈관조영장치의 기하학적 특성에 따른 선량 감소 (Reduction of Radiation Dose according to Geometric Parameters from Digital Coronary Angiography)

  • 강영한;조평곤
    • 한국방사선학회논문지
    • /
    • 제7권4호
    • /
    • pp.277-284
    • /
    • 2013
  • 심혈관 촬영 시 선량감소를 위해 실무자가 조절 가능한 기하학적 특성을 살펴보고, 각 특성에 따른 유효선량을 비교해 보았다. 인체 모형 팬텀을 이용하여 투시촬영과 영화촬영을 시행하였고, 선량의 측정은 심혈관 장치의 DAP meter를 이용하여 DAP 값을 유효선량으로 환산하였다. 먼저 영화촬영은 투시촬영에 비해 기하학적 특성 전반에 걸쳐서 선량이 약 6-7배 높았다. FPS mode에 따른 선량은 FPS를 낮게 설정할수록 선량이 70%까지 감소하였다. 선관 각도에 따른 선량은 LAO $45^{\circ}$+Caudal $30^{\circ}$이 가장 높게 측정되었고, 조사야 조절장치를 많이 적용할수록 선량은 감소하였다. X-선관과 영상증배관의 거리가 10 cm 멀어질수록 투시촬영과 영화촬영에서 각각 선량이 25-35%까지 증가하였다. FOV가 확대될수록 선량이 1.21-2배 증가하였고, 테이블과 영상증배관 거리가 10cm 멀어질수록 선량은 1.11-1.25배 까지 증가하였다. 따라서 본 연구에서 실험한 기하학적 특성인 FPS mode, 선관 각도, 조준기, 선관과 영상증배관 거리, 테이블과과 영상증배관 거리, FOV 영상 확대 등은 중재적 시술 시 실무자가 수시로 조절 가능한 인자이며, 각 특성에 따라 선량 감소 효과를 기대할 수 있다.