Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination  

Oh, Myoung-Hak (Coastal Engrg. Research Dept., Korea Ocean Research & Development Institute)
Kim, Yong-Sung (Dept. of Civil, Urban & Geosystem Engrg., Seoul National Univ.)
Park, Jun-Boum (Dept. of Civil, Urban & Geosystem Engrg., Seoul National Univ.)
Publication Information
Journal of the Korean Geotechnical Society / v.22, no.7, 2006 , pp. 45-54 More about this Journal
Abstract
Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for in-situ delineation of subsurface contamination. While the resistivity measurement has a potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements. This study is focused on verifying the applicability of resistivity and capacitance measurements of CPT module to provide information on subsurface contaminated by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination. Electrical measurements of the CPT module showed high applicability to be used in detecting saturated soils contaminated by heavy metal and diesel plume floating above the groundwater table.
Keywords
Capacitance; Cone penetrometer test; Diesel fuel contamination; Electrical resistivity; Heavy metal contamination;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 윤길림, 유찬, 이영남, 윤춘경, 이용길 (1998), '오염지반의 전기비저항치와 토성과의 상관성 연구', 한국지반공학회논문집, 제14권 2호, pp.79-92
2 Brandl, H. and Robertson, P. K. (1996), 'Geoenvironmenta1 site investigation and characterization', 2nd International Congress on Environmental Geotechnics, pp.l17-140
3 Campanella, R. G. and Davies, M. P. (1997), 'In-situ testing for geo-environmental site characterization: A mine tailings example', 14th ICSMFE, pp.43-46
4 Kaya, A. and Fang, H. Y. (1997), 'Identification of contaminated soils by dielectric constant and electrical conductivity', Journal of Environmental Engineering, Vol.123, No.2, pp.169-177   DOI   ScienceOn
5 오명학 (2005), 흙의 전기적 특성 평가를 통한 지반오염 감지시스템 개발, 서울대학교 박사학위논문
6 Okoye, C. N., Cotton, T. R. and O'Meara, D. (1995), 'Application of resistivity cone penetration testing for qualitative delineation of creosote contamination in saturated soils', Geoenvironment 2000, ASCE, pp.93-104
7 Morabito, P., Lanciani, I. and Benoit, J. (1998), Electrical resistivity cone penetration (ERCPTU) testing at the Treasure island national geotechnical experimentation site in San Franscisco, California, NSF Report
8 Campbell, J. E. (1990), 'Dielectric properties and influence of conductivity in soils at one to fifty megahertz', Soil Science Society of American Journal, 54, pp.332-341   DOI
9 이주형, 오명학, 박준범, 김형석(2002), '수분함량과 측정주파수에 따른 사질토 지반의 유전상수 변화', 한국지반공학회논문집, 제18권 6호 pp.l29-139
10 Lee, J. H., Oh, M. H., Park, J., Lee, S. H. and Ahn, K. H. (2003) 'Dielectric dispersion characteristics of sand contaminated by heavy metal, landfill leachate and BTEX', Journal of Hazardous Materials, 105, pp.83-102   DOI   ScienceOn
11 Rowe, R. K., Shang, J. Q. and Xie, Y. (2001), 'Complex pennittivity measurment system for detecting soil contamination', Canadian Geotechnical Journal, 39, pp.498-506
12 Campanella, R. G. and Weemees, I. (1990), 'Development and use of an electrical resistivity cone for groundwater contamination studies', Canadian Geotechnical Journal, 27, pp.557-567   DOI
13 오명학, 김용성, 유동주, 박준범 (2005), '함수비와 중금속 오염도에 따른 유전상수의 변화', 한국지반공학회논문집, 제21권 5호, pp.231-241   과학기술학회마을
14 Santamarina, J. C., Klein, K. A. and Fam, M. A. (2001), Soils and Waves, John Wiley & Sons
15 오명학, 이기호, 박준범 (2004), '함수비와 간극수 오염이 불포화사질토의 전기비저항에 미치는 영향', 대한토목학회 논문집, 제24권 1C호, pp.27 -34
16 Santamarina, J. C. and Fam, M. (1997), 'Dielectric permittivity of soils mixed with organic and inorganic fluids (0.2 GHz to 1.30 GHz)', Journal of Environmental and Engineering Geophysics, 2(1), pp.37-51   DOI   ScienceOn
17 van Nostrand R. G. and Cook K. L. (1966), Interpretation of Resistivity Data, U.S. Geological Survey, Professional Paper 499, USGS, Washington D.C
18 Fukue, M., Minato, T., Matsumoto, M., Horibe, H. and Taya, N. (2001), 'Use of a resistivity cone for detecting contaminated soil layers', Engineering Geology, 60, pp.361-369   DOI   ScienceOn
19 Oh, M. H., Kim, Y. S., Park, J. and Yoon, H. S. (2005), 'Complex permittivity of sand at low frequency', Journal of the Korean Geotechnical Society, Vol.21, No.2, pp.93-103   과학기술학회마을
20 Piccoli, S. and Benoit, J. (1995), 'Geo-environmental testing using the envirocone', Geoenvironment 2000, ASCE, pp.151-166