• 제목/요약/키워드: Measurement Angle

검색결과 2,166건 처리시간 0.032초

광 회절계를 이용한 격자 피치 표준 시편의 측정 및 불확도 해석 (Measurement of Grating Pitch Standards using Optical Diffractometry and Uncertainty Analysis)

  • 김종안;김재완;박병천;강주식;엄태봉
    • 한국정밀공학회지
    • /
    • 제23권8호
    • /
    • pp.72-79
    • /
    • 2006
  • We measured grating pitch standards using optical diffractometry and analyzed measurement uncertainty. Grating pitch standards have been used widely as a magnification standard for a scanning electron microscope (SEM) and a scanning probe microscope (SPM). Thus, to establish the meter-traceability in nano-metrology using SPM and SEM, it is important to certify grating pitch standards accurately. The optical diffractometer consists of two laser sources, argon ion laser (488 nm) and He-Cd laser (325 nm), optics to make an incident beam, a precision rotary table and a quadrant photo-diode to detect the position of diffraction beam. The precision rotary table incorporates a calibrated angle encoder, enabling the precise and accurate measurement of diffraction angle. Applying the measured diffraction angle to the grating equation, the mean pitch of grating specimen can be obtained very accurately. The pitch and orthogonality of two-dimensional grating pitch standards were measured, and the measurement uncertainty was analyzed according to the Guide to the Expression of Uncertainty in Measurement. The expanded uncertainties (k = 2) in pitch measurement were less than 0.015 nm and 0.03 nm for the specimen with the nominal pitch of 300 nm and 1000 nm. In the case of orthogonality measurement, the expanded uncertainties were less than $0.006^{\circ}$. In the pitch measurement, the main uncertainty source was the variation of measured pitch values according to the diffraction order. The measurement results show that the optical diffractometry can be used as an effective calibration tool for grating pitch standards.

접촉각 측정 원리를 이용한 새로운 사이즈도 측정기 (제1보) -자동 접촉각 측정 원리의 개발 - (Development of a Novel System for Measuring Sizing Degree Based on Contact Angle(I) - Development of a Novel Principle for Automatic Measurement of Contact Angle -)

  • 이찬용;김철환;최경민;박종열;권오철
    • 펄프종이기술
    • /
    • 제35권3호
    • /
    • pp.43-52
    • /
    • 2003
  • The new principle to measure a sizing degree by a contact angle was developed using an automatic determination of the 3-end point coordinates of the water droplet on a sheet, which could diminish the operator's bias during measurement. A constant amount of water was first placed on a sample sheet by a water dispenser, and then an image of the liquid droplet was captured by a digital camera and then transmitted to a computer. The program measuring for contact angle extracted a liquid contour by Gaussian function combined with a 8-direction chain code. The Euclidean equation was applied to the binary image of the liquid contour in order to measure the diameter of the contour. Finally, the contact angle of the liquid was calculated by using the diameter and the top coordinates. In addition, a surface free energy of the sample sheet and an elapsed time taken up to the complete absorption into the sheet were simultaneously measured with the contact angle.

T-joint 용접부의 형상에 따른 역학적 메카니즘에 관한 연구 (A Study on the Mechanical Mechanism According to the Groove Shape of T-welded Joint)

  • 방한서;김종명
    • Journal of Welding and Joining
    • /
    • 제17권6호
    • /
    • pp.53-61
    • /
    • 1999
  • The use of thick plate in increasing in recent years due to the rapid expansion of chemical plants, nuclear plants, ships and other industrial plants. Welding is the most popular joining techniques employed in manufacturing industrial machineries and structures. Normally, Groove shapes are prepared according to appropriate rules and regulations such as KS, JIS, AWS, LR, DNV and etc. for various thicknesses of plate. However those groove angles tend to be too large. As a result of large groove angle, residual stress, deformation of material and strength reduction is obtained. Therefore, the reliability and safety of structures and machinery tend to be decreasing. Therefore, in this paper, theoretical as well as experimental study are carried out to find optimum groove shapes for T-welded joint of mild steel. The test specimen are made in same condition with simulation model. Welding residual stresses measurement by sectional cutting method. ⅰ) The mechanical difference for change the thickness of plate and groove angle are not appeared. ⅱ) In a mechanical point of view minimum preparation angle(40°) is more suitable than maximum groove angle(60℃). ⅲ) The measurement value and distribution of welding residual stresses are not effected largely by groove angle. It is mechanical restraint that mainly affect welding residual stresses distribution. In mechanical point of view minimum groove angle is more suitable than maximum groove angle. Therefore, it is appropriate to minimize the size of groove shape in strength and safety.

  • PDF

계층적 각-거리 그래프를 이용한 물체 면적 측정을 위한 디지털 영상처리 알고리즘에 관한 연구 (A Study on Digital Image Processing Algorithm for Area Measurement of an Object Image by the Hierarchical Angle-Distance Graphs)

  • 김웅기;나성웅;이정원
    • 정보처리학회논문지B
    • /
    • 제13B권2호
    • /
    • pp.83-88
    • /
    • 2006
  • 일정한 형태의 물체를 분석하기 위해 사용되는 각-거리 그래프를 이용하여 임의의 물체의 경계선 내부 영역의 면적을 측정하는 디지털 영상처리 알고리듬을 제안한다. 물체의 경계선 내부의 한 점을 중심으로 1차 각-거리 그래프를 생성하고 이 그래프로부터 거리 값이 급격히 변화하는 위치를 추출하여 1차 그래프에서 접근하지 못한 영역을 인식하여 새 영역에서의 한 점을 중심으로 2차 각-거리 그래프를 생성한다. 물체의 형태가 복잡한 경우 차수가 증가하게 되며 이와 같이 계층적으로 구성된 각-거리 그래프 그룹에 대해 거리의 제곱을 각도 방향으로 적분하여 물체의 경계선 내부 영역의 면적을 측정한다.

CO2 가스의 존재 여부와 용액의 pH가 Silica/Pb(II) 용액 계면에서 Silica 표면의 특성에 미치는 영향 (Effects of pH and the Existence of CO2 Gas on the Silica Surface Characteristics at Silica/Pb(II) Solution Interface)

  • 이상은
    • 한국토양비료학회지
    • /
    • 제36권5호
    • /
    • pp.263-271
    • /
    • 2003
  • $CO_2$ 가스 존재여부와 pH가 Pb(II)와 sodium dodecyl sulfonate(SDS, $C_{12}H_{25}SO_3Na$) 흡착에 따른 silca 표면의 특성 변화에 미치는 영향을 contact angle 과 AFM을 이용한 힘 측정을 통하여 살펴보았다. 대기와 접촉하여 $CO_2$가 용해되는 조건에서 Pb와 SDS가 $10^{-4}M$ 씩 들어 있는 혼합용액을 처리하였을 때, fused silica 표면의 contact angle은 $PbCO_3$의 침전 때문에 최대 $46^{\circ}$로 낮았다. 반면에 $N_2$ 개스를 불어넣는 $CO_2$ 부재조건에서는 $PbCO_3$의 침전이 없었기 때문에 contact angle이 최대 $90^{\circ}$로 크게 증가되었다. $CO_2$ 부재조건에서 pH에 따른 contact angle과 AFM에서 측정한 점착력($F_{ad}$) 변화 양상은 $PbOH^+$ 화학종 분포와 유사하였으므로, Pb(II)의 silica 표면 흡착형태는 $PbOH^+$ 로 판단되었다. 한편 contact angle 과 AFM 측정결과 모두 Pb 단독처리에서 소수성을 발현하였다. 이 결과는 현재까지의 알려진 이론으로 설명할 수 없었으며 이를 위하여 원자수준에서의 심도 깊은 연구가 필요하다고 판단되었다.

학령기 남아의 발 형태 분석 (The Analysis of Foot Shape of Elementary School Boys)

  • 석은영;전은경;박순지;권숙희
    • 대한인간공학회지
    • /
    • 제23권2호
    • /
    • pp.1-12
    • /
    • 2004
  • The purposes of this study were to investigate the relationship between anthropometric data of foot and other body sizes. to categorize the foot shape of elementary school boys and to find out determinant factors related the foot that enable us to deduce the foot shape and size for the design of more comfortable shoes. Subjects of this study were 249 elementary school boys of age ranged from 6 to 11 residing Seoul and lncheon area. Anthropometric sizes were measured with the direct measurement method using Martin scales and the indirect measurement method using digital photos. Pearson's correlation, factor analysis. cluster analysis. analysis of variance, post-hoc test, and cross tabs were performed for statistical analysis of the data by SPSS program. From the investigation on the relationship between foot-related items and body items, most items of foot measure were significantly related to body size items. However, angle of the foot did not related to other body sizes although other height items and mass items of the foot did have relationships with other body sizes. Results of ANOVA indicated there were significant differences in foot-related items except for items of foot angle and all body anthropometric items by subjects' age. This implicates big toe angle, little toe angle and foot ratio factors are required in sizing shoes besides foot length. On the basis of cluster analysis using factor scores. three different foot shapes were categorized. Type 1 was large and wide foot, Type 2 was small and narrow foot with large toe angle. and Type 3 was medium foot with no deformity on big toe. These three groups show significant differences in almost all measurement items. However, Rorher index and foot angle didn't show any significant differences among groups. This implicates the foot shape can be a determinant of shoe size.

High-Frequency Bistatic Scattering from a Corrugated Sediment Surface

  • Cho, Hong-Sang;La, Hyoung-Sul;Yoon, Kwan-Seob;Na, Jung-Yul;Kim, Bong-Chae
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권2E호
    • /
    • pp.60-68
    • /
    • 2006
  • High-frequency bistatic scattering measurements from a corrugated surface were made in an acoustic water tank. First the azimuthal scattering pattern was measured from an artificially corrugated surface which has varying impedance. The corrugated surface was installed both transverse to the direction of incident wave and longitudinal to the direction of incident wave. The angle between the corrugated surface and the direction of the incident wave was about $45^{\circ}$. Second, the scattering strengths were measured from the flat sediment and the corrugated sediment. A critical angle of about $37^{\circ}$ was calculated in the acoustic water tank. The measurements were made at three fixed grazing angles: $33^{\circ}$ (lower than critical angle), $37^{\circ}$ (critical angle), and $41^{\circ}$ (higher than critical angle). The scattering angle and the grazing angle are equal in each measurement. Frequencies were from 50 kHz to 100 kHz with an increment of 1 kHz. The corrugated sediment was made transverse to the direction of the incident wave. The first measurement indicates that the scattering patterns depend on the relations between the corrugated surface and the direction of the incident wave. In the second measurement, the data measured from the flat sediment were compared to the APL-UW model and to the NRL model. The NRL model's output shows more favorable comparisons than the APL-UW model. In case of the corrugated sediment, the model and the measured data are different because the models used an isotropic wave spectrum of sediment roughness in the scattering calculations. The isotropic wave spectrum consists of $w_2$ and ${\gamma}_2$. These constants derived from sediment names or bulk size. The model which used the constants didn't consider the effect of a corrugated surface. In order to consider a corrugated surface, the constants were varied in the APL-UW model.

부정교합자의 하악과두 위치에 관한 단층방사선학적 연구 (A TOMOGRAPHIC STUDY OF CONDYLAR POSITION IN ASYMPTOMATIC SUBJECTS WITH MALOCCLUSION)

  • 김영주;고광준
    • 치과방사선
    • /
    • 제19권1호
    • /
    • pp.105-121
    • /
    • 1989
  • The author analysed tomograms and submento-vertex radiograms of 90 temporomandibular joints from 45 asymptomatic young adults. 15 had Angle class Ⅰ malocclusion, 15 classⅡ and 15 class Ⅲ. Corrected lateral tomograms were obtained in three condylar positions; centric occlusion, centric relation and 1 inch mouth opening. The condylar angulation, depth of cut, joint spaces were analysed in each radiogram. The obtained results were as follows; 1. The mean condylar angulation in Angle class Ⅰ, Ⅱ, Ⅲ group was 17.55±5.51° 13.33±8.85° 16.25±6.60° respectively, and there was no significant difference in each group. The mean condylar angulation of right side (16.62±7.23°) was larger than left side (14.80±7.33°). 2. The mean depth of cut in Angle class Ⅰ, Ⅱ, Ⅲ group was 8.13±1.61㎝, 3.05±3.80㎝, 7.75±2.19㎝, respectively. Angle class Ⅰ and class Ⅱ group revealed significant difference in measurement (p<0.0l). 3. The mean height of articular fossa in Angle class Ⅰ, Ⅱ, Ⅲ group was 8.67±3.06㎜, 9.61±2.57㎜, 8.93±2.83㎜, respectively. And the mean width of articular fossa was 19.90±2.80㎜, 19.48±3.83㎜, 20.36±4.82㎜, respectively. 4. The mean height and width of condylar head was 5.11±1.16㎜, 11.20±2.26㎜, respectively. 5. In centric occlusion, the superior joint space was the largest (3.42±1.42㎜), followed by anterior joint space (2.94±1.95㎜) and the posterior joint space (2.64±1.19㎜. In centric relation, the anterior joint space was the largest (3.86±2.17㎜), followed by the superior joint space (3.64±3.68㎜) and the posterior joint space (1.18±0.77㎜). 6. The displaced measurement from centric relation to centric occlusion was 1.10±1.04㎜ anteriorly and 0.24±0.97㎜ inferiorly. In 1 inch mouth opening state, the condylar head displaced posteroinferiorly (2.49±2.49㎜ posteriorly, 1.17±1.34㎜ inferiorly) from the apex of articular eminence. And Angle class Ⅰ and Ⅱ group, Angle class Ⅱ and Ⅲ group revealed significant difference in posterior measurement, respectively (p<0.01).

  • PDF

Reliability and Validity of Measurement Using Smart Phone-Based Goniometer on Pelvic Tilting Angle in Standing and Sitting Position

  • Ha, Sung-Min;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권1호
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.

A Study on the Validity and Test-Retest Reliability of the Measurement of the Craniovertebral Angle of the Smart Phone Application 'Angles Video Goniometer'

  • Hyeon-Seong Joo;Byeong-Soo Kim;Myung-Mo Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.454-463
    • /
    • 2022
  • Objective: The purpose of this study was to compare concurrent validity and test-retest reliability based on Craniovertebral angle of 'Angles video goniometer', a smart phone application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity. This was conducted to find out whether 'Angle video goniometer' can be used clinically. Design: Cross-sectional study Methods: Fifty subjects were imaged laterally, and the angle of the head and spine was measured using Image J and the Angles video goniometer, respectively, in a resting posture and a chin in posture. The level of concurrent validity between the two measurement methods and the level of inter-rater reliability and intra-rater reliability were analyzed. Results: For forty participants, the concurrent validity between Image J and Angles video goniometer showed very high validity with ICC of 0.997(0.995~0.999) and 0.994(0.994~0.998), CVME% 0.71~0.72%, SEM% 0.31~0.34, MDC% 0.86~0.94. The test-retest intra-rater reliability showed very high reliability ICC 0.994(0.991~0.996), CVME% 0.71%, SEM% 0.31~0.43, MDC% 0.86~1.19%. The test-retest inter-rater showed very high reliability ICC 0.995(0.992~0.997), CVME% 0.71%, SEM% 0.43~0.59%, MDC% 1.20~1.62% Conclusions: Angles video goniometer', a smartphone application, is a device with very high reliability and validity for craniovertebral angle measurement in healthy adults, and it is a device that can be easily used in clinical practice.