DOI QR코드

DOI QR Code

A Study on the Validity and Test-Retest Reliability of the Measurement of the Craniovertebral Angle of the Smart Phone Application 'Angles Video Goniometer'

  • Hyeon-Seong Joo (Department of Physical Therapy, Graduate School, Daejeon University) ;
  • Byeong-Soo Kim (Department of Physical Therapy, Graduate School, Daejeon University) ;
  • Myung-Mo Lee (Department of Physical Therapy, Daejeon University)
  • Received : 2022.09.30
  • Accepted : 2022.12.20
  • Published : 2022.12.31

Abstract

Objective: The purpose of this study was to compare concurrent validity and test-retest reliability based on Craniovertebral angle of 'Angles video goniometer', a smart phone application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity. This was conducted to find out whether 'Angle video goniometer' can be used clinically. Design: Cross-sectional study Methods: Fifty subjects were imaged laterally, and the angle of the head and spine was measured using Image J and the Angles video goniometer, respectively, in a resting posture and a chin in posture. The level of concurrent validity between the two measurement methods and the level of inter-rater reliability and intra-rater reliability were analyzed. Results: For forty participants, the concurrent validity between Image J and Angles video goniometer showed very high validity with ICC of 0.997(0.995~0.999) and 0.994(0.994~0.998), CVME% 0.71~0.72%, SEM% 0.31~0.34, MDC% 0.86~0.94. The test-retest intra-rater reliability showed very high reliability ICC 0.994(0.991~0.996), CVME% 0.71%, SEM% 0.31~0.43, MDC% 0.86~1.19%. The test-retest inter-rater showed very high reliability ICC 0.995(0.992~0.997), CVME% 0.71%, SEM% 0.43~0.59%, MDC% 1.20~1.62% Conclusions: Angles video goniometer', a smartphone application, is a device with very high reliability and validity for craniovertebral angle measurement in healthy adults, and it is a device that can be easily used in clinical practice.

Keywords

References

  1. Namwongsa S, Puntumetakul R, Neubert MS, Boucaut R. Effect of neck flexion angles on neck muscle activity among smartphone users with and without neck pain. Ergonomics. 2019;62(12):1524-33.  https://doi.org/10.1080/00140139.2019.1661525
  2. Greig AM, Straker LM, Briggs AMJP. Cervical erector spinae and upper trapezius muscle activity in children using different information technologies. Physiotherapy. 2005;91(2):119-26.  https://doi.org/10.1016/j.physio.2004.10.004
  3. Szeto GP, Lee R. An ergonomic evaluation comparing desktop, notebook, and subnotebook computers. Archives of physical medicine rehabilitation. 2002;83(4):527-32.  https://doi.org/10.1053/apmr.2002.30627
  4. AlAbdulwahab SS, Kachanathu SJ, AlMotairi MS. Smartphone use addiction can cause neck disability. Musculoskeletal Care. 2017;15(1):10-2.  https://doi.org/10.1002/msc.1170
  5. Fernandez-de-Las-Penas C, Cuadrado M, Pareja J. Myofascial trigger points, neck mobility and forward head posture in unilateral migraine. Cephalalgia. 2006;26(9):1061-70.  https://doi.org/10.1111/j.1468-2982.2006.01162.x
  6. Salahzadeh Z, Maroufi N, Ahmadi A, Behtash H, Razmjoo A, Gohari M, et al. Assessment of forward head posture in females: observational and photogrammetry methods. Journal of back and musculoskeletal rehabilitation. 2014;27(2):131-9.  https://doi.org/10.3233/BMR-130426
  7. Kraus SL. TMJ disorders: management of the craniomandibular complex: Churchill Livingstone; 1988. 
  8. Dvord J, Valach L, Schmdt S. Cervical spine injuries in Swizerland. Manual Med. 1989;4:7-16. 
  9. Saal J. The new back school prescription: stabilization training. Part II. Occupational Medicine (Philadelphia, Pa). 1992;7(1):33-42. 
  10. Kerry C. Reliability of measuring natural head posture using the craniovertebral angle. Irish Ergonomics Review. 2003;37. 
  11. Yochum TR, Rowe LJ. Essentials of skeletal radiology1987. 
  12. Han-suk L, Hyung-kuk C. A Validity Study of Craniovertebral Angle Measurement on Forward Head Posture. Journal of the Korean Society of Physical Medicine. 2013;4:145-53. 
  13. Jang H-J, Kim S-Y, Kwon C-S. Relationships between flexed posture, physical performance and psychosocial factors in elderly women. Journal of Korean Physical Therapy. 2014;26(5):358-64. 
  14. Doube M, Klosowski MM, Arganda-Carreras I, Cordelieres FP, Dougherty RP, Jackson JS, et al. BoneJ: free and extensible bone image analysis in ImageJ. Bone. 2010;47(6):1076-9.  https://doi.org/10.1016/j.bone.2010.08.023
  15. Collins TJ. ImageJ for microscopy. Biotechniques. 2007;43(S1):S25-S30.  https://doi.org/10.2144/000112517
  16. Wilmarth M, Hilliard T. Measuring head posture via the craniovertebral angle. orthopaedic physical therapy practice. 2002. 
  17. Otter SJ, Agalliu B, Baer N, Hales G, Harvey K, James K, et al. The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion. Journal of foot and ankle research. 2015;8(1):1-7.  https://doi.org/10.1186/s13047-014-0058-1
  18. Mejia-Hernandez K, Chang A, Eardley-Harris N, Jaarsma R, Gill TK, McLean JM. Smartphone applications for the evaluation of pathologic shoulder range of motion and shoulder scores-a comparative study. JSES Open Access. 2018;2(1):109-14.  https://doi.org/10.1016/j.jses.2017.10.001
  19. Portney LG. Foundations of clinical research: applications to evidence-based practice: FA Davis; 2020. 
  20. Carey MA, Laird DE, Murray KA, Stevenson JR. Reliability, validity, and clinical usability of a digital goniometer. Work. 2010;36(1):55-66.  https://doi.org/10.3233/WOR-2010-1007
  21. Walter S, Eliasziw M, Donner A. Sample size and optimal designs for reliability studies. Statistics in medicine. 1998;17(1):101-10.  https://doi.org/10.1002/(SICI)1097-0258(19980115)17:1<101::AID-SIM727>3.0.CO;2-E
  22. Suzuki T, Hashisdate H, Fujisawa Y, Yatsunami M, Ota T, Shimizu N, et al. Reliability of measurement using Image J for reach distance and movement angles in the functional reach test. Journal of Physical Therapy Science. 2021;33(2):112-7.  https://doi.org/10.1589/jpts.33.112
  23. Ionan AC, Polley M-YC, McShane LM, Dobbin KK. Comparison of confidence interval methods for an intra-class correlation coefficient (ICC). BMC Medical Research Methodology. 2014;14(1):1-11.  https://doi.org/10.1186/1471-2288-14-1
  24. Haley SM, Fragala-Pinkham MAJPt. Interpreting change scores of tests and measures used in physical therapy. Physical therapy. 2006;86(5):735-43.  https://doi.org/10.1093/ptj/86.5.735
  25. Bland JM, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. The lancet. 1986;327(8476):307-10.  https://doi.org/10.1016/S0140-6736(86)90837-8
  26. Lee MM, Song CH, Lee KJ, Jung SW, Shin DC, Shin SH. Concurrent validity and test-retest reliability of the OPTOGait photoelectric cell system for the assessment of spatio-temporal parameters of the gait of young adults. Journal of physical therapy science. 2014;26(1):81-5.  https://doi.org/10.1589/jpts.26.81
  27. Kim S-Y, Koo S-J. Effect of duration of smartphone use on muscle fatigue and pain caused by forward head posture in adults. Journal of physical therapy science. 2016;28(6):1669-72.  https://doi.org/10.1589/jpts.28.1669
  28. Behnoush B, Tavakoli N, Bazmi E, Fard FN, Shahi MHP, Okazi A, et al. Smartphone and universal goniometer for measurement of elbow joint motions: a comparative study. Asian journal of sports medicine. 2016;7(2). 
  29. Keogh JW, Cox A, Anderson S, Liew B, Olsen A, Schram B, et al. Reliability and validity of clinically accessible smartphone applications to measure joint range of motion: A systematic review. PloS one. 2019;14(5):e0215806. 
  30. Teigen LM, Kuchnia AJ, Nagel E, Deuth C, Vock DM, Mulasi U, et al. Impact of software selection and ImageJ tutorial corrigendum on skeletal muscle measures at the third lumbar vertebra on computed tomography scans in clinical populations. Journal of Parenteral and Enteral Nutrition. 2018;42(5):933-41.  https://doi.org/10.1002/jpen.1036
  31. Rha EY, Kim JM, Yoo G. Volume measurement of various tissues using the image J software. Journal of Craniofacial Surgery. 2015;26(6):e505-e6.  https://doi.org/10.1097/SCS.0000000000002022
  32. Jeffcoate WJ, Musgrove AJ, Lincoln NB. Using image J to document healing in ulcers of the foot in diabetes. International Wound Journal. 2017;14(6):1137-9.  https://doi.org/10.1111/iwj.12769
  33. Lau HMC, Chiu TTW, Lam T-H. Clinical measurement of craniovertebral angle by electronic head posture instrument: a test of reliability and validity. Manual therapy. 2009;14(4):363-8.  https://doi.org/10.1016/j.math.2008.05.004
  34. Stratford PW, Goldsmith CH. Use of the standard error as a reliability index of interest: an applied example using elbow flexor strength data. Physical therapy. 1997;77(7):745-50. https://doi.org/10.1093/ptj/77.7.745