Abstract
Purpose: The purpose of this study was to assess the intra-rater and inter-rater reliability and validity of pelvic tilting angle measurements using a smart phone-based inclinometer (Clino) compared to a palpation meter (PALM) in the standing and sitting position. This study used an interchangeable method with Clino to measure the pelvic tilting angle in the standing and sitting positions. Methods: Twenty healthy subjects were recruited. Measurements of the pelvic tilting angle in the standing and sitting positions were obtained by two examiners using the Clino and PALM. A resting session was conducted 10 minutes later to assess the intra and inter rater reliability. To assess validity of the measurement using Clino, a PALM was used as the gold standard. The intra-class correlation coefficient (ICC) was used to determine the intra and inter rater reliability of Clino and a PALM. To assess the validity, the Pearson correlation coefficients were used for two measurement techniques to measure the pelvic tilting angle in the standing and sitting positions. The statistical significance was set to ${\alpha}=0.05$. Results: Measurements of the pelvic tilt had high inter-rater reliability in the standing (ICC=0.82) and sitting (ICC=0.88) positions using Clino and intra-rater reliability in the standing (ICC=0.87) and sitting (ICC=0.91) positions using Clino. Measurements of the pelvic tilt had high validity by a comparison of PALM and Clino in the standing (r=0.83) and sitting (r=0.89) positions (p<0.05). Conclusion: The use of Clino can be recommended as a tool to replace the PALM and measure the pelvic tilt angle in the standing and sitting positions while maintaining the clinical reliability and validity.
Keywords
Clinometer; Palpation meter; Pelvic tilting angle; Reliability; Validity;
Citations & Related Records
Times Cited By KSCI : 4  (Citation Analysis)
연도 인용수 순위
1 Beardsley C, Egerton T, Skinner B. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females. Peer J. 2016;4:1881.   DOI
2 Gajdosik R, Simpson R, Smith R et al. Pelvic tilt:Intratester reliability of measuring the standing position and range of motion. Phys Ther. 1985;65(2):169-74.   DOI
3 Herrington L. Assessment of the degree of pelvic tilt within a normal asymptomatic population. Man Ther. 2011;16(6):646-8.   DOI
4 Kim JH, Chang SK. The Effects of Robo-horseback riding with changes of pelvic tilting and speeds on muscle activities of trunk and lower limb. J Kor Phys Ther. 2014;26(5):290-5.
5 Petrone MR, Guinn J, Reddin A et al. The accuracy of the palpation meter (PALM) for measuring pelvic crest height difference and leg length discrepancy. J Orthop Sports Phys Ther. 2003;33(6):319-25.   DOI
6 Hagins M, Brown M, Cook C et al. Intratester and intertester reliability of the palpation meter (PALM) in measuring pelvic position. J Manual Manip Ther. 1998;6(3):130-6.   DOI
7 Hayes AM, Place HM, Hayden A et al. The use of the PALM palpation meter for measuring pelvic tilt and its correlation with radiographic measures. The Spine Journal. 2016;16(10):S355-6.
8 Gu JS, Choi SJ, Choi HS et al. Effects of pelvic tilt training using inclinometer on joint position sense and postural alignment in patients with chronic stroke. J Kor Phys Ther. 2016;28(1):33-8.   DOI
9 DeSilva JM, Rosenberg KR. Anatomy, development, and function of the human pelvis. Anat Rec. 2017;300(4):628-32.   DOI
10 Endo K, Suzuki H, Nishimura H et al. Sagittal lumbar and pelvic alignment in the standing and sitting positions. J Orthop Sci. 2012;17(6):682-6.   DOI
11 Schache AG, Blanch P, Rath D et al. Three-dimensional angular kinematics of the lumbar spine and pelvis during running. Hum Mov Sci. 2002;21(2):273-93.   DOI
12 Chaleat-Valayer E, Mac-Thiong JM, Paquet J et al. Sagittal spino-pelvic alignment in chronic low back pain. Eur Spine J. 2011;20(5):634-40.   DOI
13 Schache AG, Blanch PD, Murphy AT. Relation of anterior pelvic tilt during running to clinical and kinematic measures of hip extension. Br J Sports Med. 2000;34(4):279-83.   DOI
14 Park SH, Yuk GC, Ahn SH et al. Lumbar Spine Kinematics during anterior and posterior pelvic tilting in supine and prone positions. J Kor Phys Ther. 2011;23(6):9-14.
15 Sullivan MK, Dejulia JJ, Worrell TT. Effect of pelvic position and stretching method on hamstring muscle flexibility. Med Sci Sports Exerc. 1992;24(12):1383-9.
16 Sahrmann SA. Diagnosis and treatment of movement impairment syndromes. St Louis, Mosby. 2002.
17 Yoon TL. Validity and reliability of an inertial measurement unit-based 3D angular measurement of shoulder joint motion. J Kor Phys Ther. 2017;29(3):145-51   DOI
18 Haeri Seyed MJ, Razeghi M, TaghizadehIS et al. Designing a new method for measuring lumbar lordosis. Qom university of medical sciences journal. 2015;9(9):35-41.
19 Kinsella SM, Harvey NL. A comparison of the pelvic angle applied using lateral table tilt or a pelvic wedge at elective caesarean section. Anaesthesia. 2012;67(12):1327-31.   DOI
20 Panjabi MM. The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis. J Spinal Disord. 1992;5(4):390-6.   DOI
21 Bonifacio D, Lopes I, Martins F et al. Intra-and inter-rater reliability in photogrammetric pelvic tilt angles analysis. IJTR. 2013;20(2):86-90.
22 Kim SJ, Jeong SY, Yoon TL. The effect of visual feedback of head angles with using a mobile posture-aware system on craniocervical angle and neck and shoulder muscles fatigue during watching the smartphone. J Kor Phys Ther. 2018;30(2):47-53.   DOI