• Title/Summary/Keyword: Measurement

Search Result 46,792, Processing Time 0.074 seconds

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

  • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

  • PDF

COMPARISON OF POLYMERIZATION SHRINKAGE AND STRAIN STRESS OF SEVERAL COMPOSITE RESINS USING STRAIN GUAGE (스트레인 게이지를 이용한 수종의 복합레진의 중합수축 및 수축응력의 비교)

  • Kim, Young-Kwang;Yoo, Seung-Hoon;Kim, Jong-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.516-526
    • /
    • 2004
  • Polymerization shrinkage of photoinitiation type composite resin cause several clinical problems. The purpose of this study was to evaluate the shrinkage strain stress, linear polymerization shrinkage, compressive strength and microhardness of recently developed composite resins. The composite resins were divided into four groups according to the contents of matrix and filler type. Group I : $Denfil^{TM}$(Vericom, Korea) with conventional matrix, Group II : $Charmfil^{(R)}$(Dentkist, Korea) with microfiller and nanofller mixture, Group III : $Filtek^{TM}$ Z250(3M-ESPE, USA) TEGDMA replaced by UDMA and Bis-EMA(6) in the matrix, and Group IV : $Filtek^{TM}$ Supreme(3M-ESPE, USA) using pure nanofiller. Preparation of acrylic molds were followed by filling and curing with light gun. Strain gauges were attached to each sample and the leads were connected to a strainmeter. With strainmeter shrinkage strain stress and linear polymerization shrinkage was measured for 10 minutes. The data detected at 1 minute and 10 minutes were analysed statistically with ONE-way ANOVA test. To evaluate the mechanical properties of tested materials, compressive hardness test and microhardness test were also rendered. The results can be summarized as follows : 1. Filling materials in acrylic molds showed initial temporary expansion in the early phase of polymerization. This was followed by contraction with the rapid increase in strain stress during the first 1 minute and gradually decreased during post-gel shrinkage phase. After 1 minute, there's no statistical differences of strain stress between groups. The highest strain stress was found in group IV and followed by group III, I, II at 10 minutes-measurement(p>.05). In regression analysis of strain stress, group III showed minimal inclination and followed by group II, I, IV during 1 minute. 2. In linear polymerization shrinkage test, the composite resins in every group showed initial increase of shrinkage velocity during the first 1 minute, followed by gradually decrease of shrinkage velocity. After 1 minute, group IV and group III showed statistical difference(p<.05). After 10 minutes, there were statistical differences between group IV and group I, III(p<.05) and between group II and group III(p<.05). In regression analysis of linear polymerization shrinkage, group II showed minimal inclination and followed by group IV, III, I during 1 minute. 3. In compressive strength test, group III showed the highest strength and followed by group II, IV, I. There were statistical differences between group III and group IV, I(p<.05). 4. In microhardness test, upper surfaces showed higher value than lower surfaces in every group(p<.05).

  • PDF

The Changes of Pulmonary Function and Systemic Blood Pressure in Patients with Obstructive Sleep Apnea Syndrome (폐쇄성 수면 무호흡증후군 환자에서 혈압 및 폐기능의 변화에 관한 연구)

  • Moon, Hwa-Sik;Lee, Sook-Young;Choi, Young-Mee;Kim, Chi-Hong;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.2
    • /
    • pp.206-217
    • /
    • 1995
  • Background: In patients with obstructive sleep apnea syndrome(OSAS), there are several factors increasing upper airway resistance and there is a predisposition to compromised respiratory function during waking and sleep related to constitutional factors including a tendency to obesity. Several recent studies have suggested a possible relationship between sleep apnea(SA) and systemic hypertension. But the possible pathophysiologic link between SA and hypertension is still unclear. In this study, we have examined the relationship among age, body mass index(BMI), pulmonary function parameters and polysomnographic data in patients with OSAS. And also we tried to know the difference among these parameters between hypertensive OSAS and normotensive OSAS patients. Methods: Patients underwent a full night of polysomnography and measured pulmonary function during waking. OSAS was diagnosed if patients had more than 5 apneas per hour(apnea index, AI). A careful history of previously known or present hypertension was obtained from each patient, and patients with systolic blood pressure $\geq$ 160mmHg and/or diastolic blood pressure $\geq$ 95mmHg were classified as hypertensives. Results: The noctural nadir of arterial oxygen saturation($SaO_2$ nadir) was negatively related to AI and respiratory disturbance index(RDI), and the degree of noctural oxygen desaturation(DOD) was positively related to AI and RDI. BMI contributed to AI, RDI, $SaO_2$ nadir and DOD values. And also BMI contributed to $FEV_1,\;FEV_1/FVC$ and DLco values. There was a correlation between airway resistance(Raw) and AI, and there was a inverse correlation between DLco and DOD. But there was no difference among these parameters between hypertensive OSAS and normotensive OSAS patients. Conclusion: The obesity contributed to the compromised respiratory function and the severity of OSAS. AI and RDI were important factors in the severity of hypoxia during sleep. The measurement of pulmonary function parameters including Raw and DLco may be helpful in the prediction and assessment of OSAS patients. But we could not find clear difference between hypertensive and normotensive OSAS patients.

  • PDF

The Role of Control Transparency and Outcome Feedback on Security Protection in Online Banking (계좌 이용 과정과 결과의 투명성이 온라인 뱅킹 이용자의 보안 인식에 미치는 영향)

  • Lee, Un-Kon;Choi, Ji Eun;Lee, Ho Geun
    • Information Systems Review
    • /
    • v.14 no.3
    • /
    • pp.75-97
    • /
    • 2012
  • Fostering trusting belief in financial transactions is a challenging task in Internet banking services. Authenticated Certificate had been regarded as an effective method to guarantee the trusting belief for online transactions. However, previous research claimed that this method has some loopholes for such abusers as hackers, who intend to attack the financial accounts of innocent transactors in Internet. Two types of methods have been suggested as alternatives for securing user identification and activity in online financial services. Control transparency uses information over the transaction process to verify and to control the transactions. Outcome feedback, which refers to the specific information about exchange outcomes, provides information over final transaction results. By using these two methods, financial service providers can send signals to involved parties about the robustness of their security mechanisms. These two methods-control transparency and outcome feedback-have been widely used in the IS field to enhance the quality of IS services. In this research, we intend to verify that these two methods can also be used to reduce risks and to increase the security protections in online banking services. The purpose of this paper is to empirically test the effects of the control transparency and the outcome feedback on the risk perceptions in Internet banking services. Our assumption is that these two methods-control transparency and outcome feedback-can reduce perceived risks involved with online financial transactions, while increasing perceived trust over financial service providers. These changes in user attitudes can increase the level of user satisfactions, which may lead to the increased user loyalty as well as users' willingness to pay for the financial transactions. Previous research in IS suggested that the increased level of transparency on the process and the result of transactions can enhance the information quality and decision quality of IS users. Transparency helps IS users to acquire the information needed to control the transaction counterpart and thus to complete transaction successfully. It is also argued that transparency can reduce the perceived transaction risks in IS usage. Many IS researchers also argued that the trust can be generated by the institutional mechanisms. Trusting belief refers to the truster's belief for the trustee to have attributes for being beneficial to the truster. Institution-based trust plays an important role to enhance the probability of achieving a successful outcome. When a transactor regards the conditions crucial for the transaction success, he or she considers the condition providers as trustful, and thus eventually trust the others involved with such condition providers. In this process, transparency helps the transactor complete the transaction successfully. Through the investigation of these studies, we expect that the control transparency and outcome feedback can reduce the risk perception on transaction and enhance the trust with the service provider. Based on a theoretical framework of transparency and institution-based trust, we propose and test a research model by evaluating research hypotheses. We have conducted a laboratory experiment in order to validate our research model. Since the transparency artifact(control transparency and outcome feedback) is not yet adopted in online banking services, the general survey method could not be employed to verify our research model. We collected data from 138 experiment subjects who had experiences with online banking services. PLS is used to analyze the experiment data. The measurement model confirms that our data set has appropriate convergent and discriminant validity. The results of testing the structural model indicate that control transparency significantly enhances the trust and significantly reduces the risk perception of online banking users. The result also suggested that the outcome feedback significantly enhances the trust of users. We have found that the reduced risk and the increased trust level significantly improve the level of service satisfaction. The increased satisfaction finally leads to the increased loyalty and willingness to pay for the financial services.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

Development and Assessment Individual Maximum Permissible Dose Method of I-131 Therapy in High Risk Patients with Differentiated Papillary Thyroid Cancer (물리학 선량법을 이용한 갑상선암의 개인별 최대안전용량 I-131 치료법 개발과 유용성 평가)

  • Kim, Jeong-Chul;Yoon, Jung-Han;Bom, Hee-Seung;JaeGal, Young-Jong;Song, Ho-Chun;Min, Jung-Joon;Jeong, Heong;Kim, Seong-Min;Heo, Young-Jun;Li, Ming-Hao;Park, Young-Kyu;Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.110-119
    • /
    • 2003
  • Purpose: Radioiodine (I-131) therapy is an effective modality to reduce both recurrence and mortality rates in differentiated thyroid cancer. Whether higher doses shows higher therapeutic responses was still debatable. The purpose of this study was to validate curve-fitting (CF) method measuring maximum permissible dose (MPD) by a biological dosimetry using metaphase analysis of peripheral blood lymphocytes. Materials and Methods: Therapeutic effects of MPD was evaluated in 58 patients (49 females and 9 males, mean age $50{\pm}11$ years) of papillary thyroid cancer. Among them 43 patients were treated with ${\Leq}7.4GBq$, while 15 patients with ${\geq}9.25GBq$. The former was defined as low-dose group, and the latter high-dose group. Therapeutic response was defined as complete response when complete disappearance of lesions on follow-up I-131 scan and undetectable serum thyroglobulin levels were found. Statistical comparison between groups were done using chi-square test. P value less than 0.05 was regarded as statistically significant. Results: MPD measured by CF method using tracer and therapeutic doses were $13.3{\pm}1.9\;and\;13.8{\pm}2.1GBq$, respectively (p=0.20). They showed a significant correlation (r=0.8, p<0.0001). Exposed doses to blood measured by CF and biological methods were $1.54{\pm}0.03\;and\;1.78{\pm}0.03Gy$ (p=0.01). They also showed a significant correlation (r=0.86, p=0.01). High-dose group showed a significantly higher rate of complete response (12/15, 80%) as compared to the low-dose group (22/43, 51.2%) (p=0.05). While occurrence of side effects was not different between two groups (40% vs. 30.2%, p=0.46). Conclusion: Measurement of MPD using CF method is reliable, and the high-dose I-131 therapy using MPD gains significantly higher therapeutic effects as compared with low-dose therapy.

The Relationship Between Chewing Ability and Health Status in the Long-lived Elderly of Kyungpook Area (경북지역 장수노인의 저작능력과 건강상태)

  • Lee, Hee-Kyung;Lee, Young-Kwon
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.2
    • /
    • pp.200-207
    • /
    • 1999
  • Background: The objective of this study is to evaluate the effect of the dental and general health in relation to the state of dentition and chewing ability by surveying oral condition and anthropometric measure in order to provide primary statistics for the development of a program which may lead to an improvement in the long-lived elderly health status in a rural community. Materials and Methods: The subjects of this study were 97 rural long-lived elderly(27 males and 70 females) who were over 85 years-old (average age of subjects are $88.14{\pm}3.20$ year old) in Sungju-Gun, Kyungpook Province. Data were collected by using questionnaires and direct measurement of anthropometrics, and oral examination from all 97 subjects on July, 1999. Results: The following results were obtained: 1. 53.6% of all subjects believe that they are healthy. The average values of height, weight, BMI, body fat, lean body fat and total water were $148.8{\pm}11.2cm$, $46.9{\pm}10.5kg$, $21.2{\pm}3.5kg/m^2$, $26.7{\pm}6.9%$, $73.0{\pm}7.1%$, and $53.4{\pm}5.2%$, respectively. 2. The average number of teeth remaining in the subjects were $3.50{\pm}5.71$; the number of maxillary teeth remaining were $1.08{\pm}2.88$; and the number of mandibular teeth remaining were $2.41{\pm}3.76$. The maximum number of teeth remaining among subjects were 22 teeth, and the fully edentulous(no natural teeth) people were 76.3%. The oral conditions of the subjects were 52.6% using denture, 23.7% using natural teeth, and 23.7% masticating edentulous ridge without denture. 3. In terms of oral condition in self-assessment of health, digestive ability, and chewing ability ; On self-assessment of health, 47.1% of those wearing denture group responded as feeling good, 56.5% of those in the group of edentulous without denture, and 65.2% in group of natural teeth only. On self-assessment of digestive ability, 82.4% of those in group of denture responded as feeling good, 65.2% of those in group of no teeth and no denture, and 73.9% of those in group of natural teeth only. On self-assessment of chewing ability, 90.2% of those in the group wearing a denture, 60. 9% of those in the group of no teeth and no denture, and 65.2% of those in the group of natural teeth only. 4. In terms of oral condition in anthropometric measurements; The height, weight, body fat, lean body mass, and total water according to oral conditions were $150.0{\pm}10.7cm$, $49.0{\pm}10.9kg$, $26.9{\pm}6.6%$, $72.7{\pm}7.0%$, $53.2{\pm}5.1%$, respectively, in group wearing a denture, $142.7{\pm}6.0cm$, $43.2{\pm}5.5kg$, $29.5{\pm}7.2%$, $70.8{\pm}6.9%$, $51.8{\pm}5.0%$, respectively, in the group of no teeth and no denture, and $152.3{\pm}14.1cm$, $45.9{\pm}12.6kg$, $23.4{\pm}6.0%$, $75.9{\pm}6.9%$, $55.6{\pm}5.1%$, respectively, in the group of natural teeth only. Conclusion: The subjective measurements of good health were higher denture user, and natural teeth.

  • PDF

Measurement of the Grafts for the Anterior Cruciate Ligament Reconstruction with Tension Load Technique and Achilles Tendon Autograft using Postoperative Magnetic Resonance Imaging (자가 아킬레스 건과 장력 부하 기법을 이용한 전방십자인대 재건술 후 자기 공명 영상을 이용한 이식건의 평가)

  • Seo, Jai-Gon;Moon, Young-Wan;Yoo, Jae-Chul;Chang, Moon-Jong;Kim, Seung-Yeon;Kim, Mu-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.191-197
    • /
    • 2008
  • Purpose: To evaluate the postoperative magnetic resonance image (MRI) findings of anterior cruciate ligament (ACL) reconstructed with a tension load technique using auto-Achilles tendon, and to compare the results with knees with a native ACL. Materials and Methods: We evaluated 21 postoperative MRI scan of 21 patients (group A) who had undergone ACL reconstruction between January 1995 and November 1996. The control group (group B) consisted of 50 patients whose meniscus tear had been operated by arthroscopy and whose ACL was intact. We measured the orientation of the graft in the sagittal and coronal planes and compared it with that of the native ACL. Results: The mean sagittal angle of the ACL angle in group A ($55.7{\pm}5.6^{\circ}$, range $47.2{\sim}68.8^{\circ}$) was statistically lesser than group B ($58.7{\pm}3.8^{\circ}$, range $50.4{\sim}67.5^{\circ}$) (p=0.036). But there was no statistically significant difference between the two groups with regard to the mean ACL-Blumensaat line angle (group A: $8.1^{\circ}{\pm}4.9^{\circ}$, range $1.7^{\circ}{\sim}22.0^{\circ}$, group B: $8.6^{\circ}{\pm}3.6^{\circ}$, range $2.6^{\circ}-18.1^{\circ}$) and the mean coronal angle of the ACL (group A: $64.9^{\circ}{\pm}9.1^{\circ}$, range $46.9^{\circ}{\sim}76.4^{\circ}$, group B: $65.9^{\circ}{\pm}4.4^{\circ}$, range $57.7^{\circ}{\sim}75.2^{\circ}$)(p=0.88, p= 0.62). In the sagittal plane, the mean center of tibial insertion of the ACL graft in group A ($31.9{\pm}7.1%$, range 22.4-47.9%) was positioned more anteriorly than group B ($37.0{\pm}4.9%$, range $18.5{\sim}44.7%$)(p=0.005). But in the coronal plane, there was no statistically significant difference between the two groups(group A: $46.3{\pm}2.8%$, range $42.1{\sim}52.5%$, group B: $45.7{\pm}2.8%$, range $41.0{\sim}49.1%$)(p=0.392). Conclusion: We performed an ACL reconstruction with the tension load technique using auto-Achilles tendon and we found that the graft orientation in MRI was as good as that of the native ACL.

  • PDF

Nutritional Studies for Improvement of Feeding on Korean Native Goat - Absorption of Nutrients in Rumen - (한국재래산양(韓國在來山羊)의 사양개선(飼養改善)에 관(關)한 연구(硏究) - 제일위((第一胃)에서의 영양소(營養素) 흡수(吸收)에 대(對)하여 -)

  • Kwon, Soon Ki
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.284-302
    • /
    • 1982
  • Development of protein resources as food has been a big issue especially in Southeast Asia region, and intake of protein is also insufficient in Korea. To cope with this shortage of protein resources and its improvement together with increased production of high nutritive animal protein, studies were carried out on feeding of Korean native goats. In the experiments were made absorption of carbohydrate and volatile fatty acid in miniature rumen, and absorption of amino acid in rumen as in vivo were conducted as part of studies on nutritional absorption in rumen. Those nutritional for improvement of feeding and management as described above are summarized as following. 1. According to the result of test on the nutritional absorption of native goat by means of miniature rumen method, absorption ratio of VFA measured at 0.5, 1 and 2 hours after injection of nutrition showed propionic acid 70-86%, acetic acid 74-87%, and lactic acid 76-89%. In the absorption of organic substances, ethyl alcohol of 0.5% showed 29-87% and lactic acid of 0.1M showed 12-27% of absorption ratio. 2. Result of absorption measurement in rumen from L-type free amino acid injection in the content of rumen vein showed lower rate at menthionine-free group compared to whole-egg amino acid injection in the content of rumen vein showed lower rate at methioine-free group compared to whole-egg amino acid group, and high absorption ratio was observed at methionine 3 times group and urea added group. Deficiency of methionine caused no change of the content in mucous membranes. 3. Absorption of amino acid in rumen muscular layer showed equal tendency as in the mucous membrane without exerting any influence of methionine deficiency. At the methionine3-times group, content of methionine and glutamine were increased by 14.7 and 4.4 times as compared to whole-egg amino acid group, an absorption ratio of glutamine, proline and valine were increased at urea added group. 4. In general, concentration of amino acid in rumen vein plasma was lower than in rumen mucous membrane and muscular layer. Absorption ratio of amino acid is decreased due to methionine deficiency, and tripling of methionine or urea adding caused increment of amino acid. Absorption pattern is thus varied depending on the composition of amino acid. 5. At the urea added group, content of ammonia-N, amino-N and urea were increased in rumen muscular layer. As the inside of goat's rumen was unable to clean thoroughly, investigation was made on remaining bacteria, however, variation of ammonia-N was affected by these bacterial content. 6. Variation in rumen structure by differential absorption of amino acid was observed by general microscope and fluorescent microscope. According to the result of observation in the methionine 3 times group, single cylinder epithelium of mucous membrane showed rather thin, and it was thick at urea added group though no significant differences existed among test groups in submucous membrane and muscular layer.

  • PDF