• Title/Summary/Keyword: Measured stage

Search Result 2,544, Processing Time 0.034 seconds

Induction of Sexual Stage and Colony Morphology of Some Isolates of Sclerotium rolfsii Causing Spotted Leaf Rot in Plants

  • Pandey, M.K.;Sarma, B.K.;Singh, U.P.
    • Mycobiology
    • /
    • v.33 no.1
    • /
    • pp.7-11
    • /
    • 2005
  • Twenty-two isolates of Sclerotium rolfsii causing spotted leaf rot from Varanasi, India were grown on 6% Cyperus rotundus rhizome meal agar (CRMA) medium for the induction of athelial stage (Athelia rolfsii). Only one isolate obtained from Sphaeranthus indicus formed basidial stage on CRMA medium while the other 21 isolates did not. Basidial stage was also produced in S. indicus isolate at different concentrations (5.5, 6.0 and 6.5% w/v) of CRMA medium. Size of basidia, sterigmata and basidiospores of this isolate was measured. Basidia clavate, hyaline and measured $10{\sim}12{\times}4{\sim}5\;{\mu}m$ in size, basidiospores hyaline, unicellular, subglobose to ellipsoid produced on sterigmata and measured $3{\sim}5{\times}2{\sim}4\;{\mu}m$ in size, sterigmata hyaline and measured $4{\sim}5{\times}1.5{\sim}2\;{\mu}m$ in size. The results of the present study revealed wide variation in spotted leaf rot isolates of S. rolfsii. A reddish zone around the colony of S. rolfsii isolate from Vernonia sp. was observed on CRMA medium. HPLC analysis of the zone revealed the presence of gallic and ferulic acid which were also thought to be responsible for reduced mycelial growth of the isolate on CRMA medium.

Analysis and compensation of Repeatability for Ultra-precision Stage (초정밀 스테이지의 반복정밀도 분석 및 보정)

  • 박종하;황주호;박천홍;홍준희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.800-803
    • /
    • 2004
  • The refractive index of the laser interferometer is compensated using the simultaneously measured variations of room temperature and humidity in the method. In order to investigate the limit of compensation, the stationary test against two fixed reflectors mounted on the zerodur plate is performed firstly. From the experiment, it is confirmed that the measuring error of the laser interferometer can be improved from 0.12$\mu$m to 0.17$\mu$m by the application of the method. Secondly, for the verification of the compensating effect, it is applied to estimate the positioning accuracy of an ultra precision aerostatic stage. Two times of the refractive index compensation are performed to acquire the positioning error of the stage from the initially measured data, that is, to the initially measured positioning error and to the measured positioning error profile after the NC compensation. Although the positioning error of anaerostatic stage cannot be clarified perfectly, it is known that by the compensation method, the measuring error by the laser interferometer can be improved to within 0.15$\mu$m. English here.

  • PDF

Positioning control error of 2-Axis Stage for Diamond Turning Machine (DTM가공을 위한 2축 Stage의 정밀 이송특성연구)

  • Lee E.S.;Park J.J.;Lee M.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.309-312
    • /
    • 2005
  • DTM (Diamond Turning Machine) is using for ultra precision manufacturing such as, plastic lens die or aspherical optics. This study is on a design of precision 2-axis stage for DTM. We designed and manufactured a back lash free stage using different weights and measured the positioning accuracy using Interferometer. Also, the 2-D moving accuracy is measured using the high magnification CCD technique. Then, the stage is tested with the machining of spherical and aspherical lens in a DTM with air bearing spindle. It was shown that the back lash free stage is effective for improving the positioning accuracy. Also, positioning control errors in motion control board were able to be found using the proposed stages system.

  • PDF

An Experimental Study on the Pumping Performance of the Three-Stage Disk-Type Drag Pump (3단 원판형 드래그펌프의 배기 성능에 관한 실험적 연구)

  • Hwang, Young-Kyu;Heo, Joons-Sik;Kwon, Myoung-Keun;Yang, Seong-Min
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.203-208
    • /
    • 2001
  • In this paper, the pumping performance of the three-stage disk-type drag pump which works in the outlet pressure range from 4 to 0.01 Torr is studied experimentally. The rotational speed of the pump is 24,000rpm, and nitrogen is used as a test gas, The pumping characteristics of various drag pumps are investigated. The inlet pressures are measured for various outlet pressures of the test pump. The maximum compression ratios for zero throughput are measured for three-stage, two-stage BSC type, helical-type, one-stage BSC type and one-stage OSC type, respectively.

  • PDF

Bleaching of Oak Kraft Pulp by O, Eo and C/D Stage (O, Eo 및 C/D단계를 이용한 신갈나무 크라프트펄프표백)

  • 김동호;백기현
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.29 no.3
    • /
    • pp.43-50
    • /
    • 1997
  • The purpose of this study was to decrease pollutants of effluents from KP bleaching. Multistage bleaching that combined with O, Eo, and C/D stage was conducted, after optimum bleaching conditions of O, Eo, and C/D stage were determined. Moreover the properties for bleached pulps and pollution level of bleaching effluent were measured by each standard method. Due to increase on the brightness and delignification of pulps by O, Eo, and C/D stage bleaching. It was possible that bleaching sequences were reduced from five stage to four stage. In addition to, OC/DEoD and OC/DEopD bleaching sequences had higher brightness than CEDED bleaching sequence. The pulps bleached by O and Eo stage had higher in tensile index than conventional bleaching sequences with the similar results in burst and tear index. While each bleaching sequences had little differences, bleaching sequences with Eo stage had higher in physical properties than with Eop stage. The pollution level measured by Chemical Oxygen Demand(COD), Biochemical Oxygen Demand(BOD) and Color of bleaching effluents were much lower in combined bleaching sequences of O, Eo and C/D stage than that of CEDED sequence. Particularly, a pollution index of bleaching effluents generated by C/DEoDEB and OC/DEopDED bleaching sequences were lower than that from the other bleaching sequences.

  • PDF

An Experimental Study on the Pumping Performance of the Turbo-Type Disk-Type Drag Pump (터보형 원판형 드래그펌프의 배기특성에 관한 실험적 연구)

  • Hwang Young-Kyu;Heo Joong-Sik;Kwon Myung-Keun;Lee Seung-Jae
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.577-580
    • /
    • 2002
  • In this paper, the pumping performance of the disk-type drag pump which works in the outlet pressure range from 4 to 0.001 Torr is studied experimentally. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate Pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

  • PDF

Estimation of 2D Position and Flatness Errors for a Planar XY Stage Based on Measured Guideway Profiles

  • Hwang, Joo-Ho;Park, Chun-Hong;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.64-69
    • /
    • 2007
  • Aerostatic planar XY stages are frequently used as the main frames of precision positioning systems. The machining and assembly process of the rails and bed of the stage is one of first processes performed when the system is built. When the system is complete, the 2D position, motion, and stage flatness errors are measured in tests. If the stage errors exceed the application requirements, the stage must be remachined and the assembly process must be repeated. This is difficult and time-consuming work. In this paper, a method for estimating the errors of a planar XY stage is proposed that can be applied when the rails and bed of the stage are evaluated. Profile measurements, estimates of the motion error, and 2D position estimation models were considered. A comparison of experimental results and our estimates indicated that the estimated errors were within $1{\mu}m$ of their true values. Thus, the proposed estimation method for 2D position and flatness errors of an aerostatic planar XY stage is expected to be a useful tool during the assembly process of guideways.

An Experimental Study on the Pumping Performance of the Multi-stage Disk-type Drag Pump (다단 원판형 드래그펌프의 배기 성능에 관한 실험적 연구)

  • 권명근;허중식;황영규
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Experimental investigations are performed for the rarefied gas flows in a multi-stage disk-type drag pump. The pump considered in the present study consists of grooved rotors and stators. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured under the outlet pressure range of 0.13∼533 Pa. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm, and nitrogen is used as a test gas. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

Calculation and Measurement of Column Shortening High-Rise RC Structure (초고층 RC구조의 기둥축소량 해석 및 현장계측)

  • 이성원;박현일;김원식;오정근
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.133-138
    • /
    • 2003
  • Axial shortenings of wall and columns were measured on level 2 and precise leveling between wall and columns were surveyed on level 5 at the Galleria Palace structure. Measured and surveyed shortening values were compared with the analysis results at the earlier stage on the process of construction for evaluating the predicted values. Though measured values represent relatively low and scattered values at earlier construction stage, probably they show similar slope curves to predicted ones with the progress of time.

  • PDF

A Study on the Optimal Structural Design using FEM for Micro Stage (마이크로 스테이지의 유한요소해석)

  • Kim, Jae-Yeol;Gwak, Lee-Gu;Han, Jae-Ho;Kim, Hang-U
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.10
    • /
    • pp.60-65
    • /
    • 2002
  • For optimal design of micro stage, we measured the displacement of piezoelectric transducer that was based on voltage value. And the micro stage was analyzed using FEM with displacement data including voltage value of piezoelectric transducer. For verification of analysis results, the displacements were measured by using Laser-interferometer. And researchers confirmed to propriety on design of micro stage with FEM, we obtained 3.5% error rate between measurement results and analyzing results.