• Title/Summary/Keyword: Measure of agreement H

Search Result 33, Processing Time 0.029 seconds

Field Tests and Resonance Behavior Corresponding to the Damping Ratio of a High Speed Railroad Bridge (고속철도 교량의 현장실험 및 감쇠비 개선에 따른 공진 시 동적응답의 분석)

  • Kim, Sungil;Kim, Hyunmin;Park, Donguk
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.4
    • /
    • pp.305-310
    • /
    • 2013
  • In general, it is difficult to measure dynamic responses of a bridge with stepwise increasing speed of a train during commercial service on a high speed railroad. However, before opening the 2nd stage of the Gyeongbu high speed railroad, there was an opportunity for field tests and measurements of the bridge with stepwise increasing speed(from 170km/ h to 315km/h). The measured responses were compared with the results of a developed bridge/train interaction analysis. Although good agreement was found throughout almost the entire range of speeds, relatively large differences were found in the vicinity of the critical speed at which resonance behavior of the bridge occurs. To investigate the cause of this, reanalyses are performed with re-estimated damping ratios from field tests.

Estimation of tensile strength and moduli of a tension-compression bi-modular rock

  • Wei, Jiong;Zhou, Jingren;Song, Jae-Joon;Chen, Yulong;Kulatilake, Pinnaduwa H.S.W.
    • Geomechanics and Engineering
    • /
    • v.24 no.4
    • /
    • pp.349-358
    • /
    • 2021
  • The Brazilian test has been widely used to determine the indirect tensile strength of rock, concrete and other brittle materials. The basic assumption for the calculation formula of Brazilian tensile strength is that the elastic moduli of rock are the same both in tension and compression. However, the fact is that the elastic moduli in tension and compression of most rocks are different. Thus, the formula of Brazilian tensile strength under the assumption of isotropy is unreasonable. In the present study, we conducted Brazilian tests on flat disk-shaped rock specimens and attached strain gauges at the center of the disc to measure the strains of rock. A tension-compression bi-modular model is proposed to interpret the data of the Brazilian test. The relations between the principal strains, principal stresses and the ratio of the compressive modulus to tensile modulus at the disc center are established. Thus, the tensile and compressive moduli as well as the correct tensile strength can be estimated simultaneously by the new formulas. It is found that the tensile and compressive moduli obtained using these formulas were in well agreement with the values obtained from the direct tension and compression tests. The formulas deduced from the Brazilian test based on the assumption of isotropy overestimated the tensile strength and tensile modulus and underestimated the compressive modulus. This work provides a new methodology to estimate tensile strength and moduli of rock simultaneously considering tension-compression bi-modularity.

Development of Bioelectric Impedance Measurement System Using Multi-Frequency Applying Method

  • Kim, J.H.;Jang, W.Y.;Kim, S.S.;Son, J.M.;Park, G.C.;Kim, Y.J.;Jeon, G.R.
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.368-376
    • /
    • 2014
  • In order to measure the segmental impedance of the body, a bioelectrical impedance measurement system (BIMS) using multi-frequency applying method and two-electrode method was implemented in this study. The BIMS was composed of constant current source, automatic gain control, and multi-frequency generation units. Three experiments were performed using the BIMS and a commercial impedance analyzer (CIA). First, in order to evaluate the performance of the BIMS, four RC circuits connected with a resistor and capacitor in serial and/or parallel were composed. Bioelectrical impedance (BI) was measured by applying multi-frequencies -5, 10, 50, 100, 150, 200, 300, 400, and 500 KHz - to each circuit. BI values measured by the BIMS were in good agreement with those obtained by the CIA for four RC circuits. Second, after measuring BI at each frequency by applying multi-frequency to the left and right forearm and the popliteal region of the body, BI values measured by the BIMS were compared to those acquired by the CIA. Third, when the distance between electrodes was changed to 1, 3, 5, 7, 9, 11, 13, and 15 cm, BI by the BIMS was also compared to BI from the CIA. In addition, BI of extracellular fluid (ECF) was measured at each frequency ranging from 10 to 500 KHz. BI of intracellular fluid (ICF) was calculated by subtracting BI of ECF measured at 500 kHZ from BI measured at seven frequencies ranging from 50 to 500 KHz. BI of ICF and ECF decreased as the frequency increased. BI of ICF sharply decreased at frequencies above 300 KHz.

Performance Improvement of Material Recognition Sensor Using Cubic Spline Interpolation (Spline보간식을 이용한 물체재질인식센서의 성능개선)

  • Park, J.G.;Lim, Y.C.;Cho, K.Y.;Kim, Y.G,;Chang, Y.H.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.43-51
    • /
    • 1992
  • This paper describes a noble robot sensor designed to recognize an unknown material by measuring its thermal conductivity on various ambient temperature. The excellent agreement has been obtained between the measured sensor temperature and the calculated sensor temperature by cubic spline interpolation. The active sensor to measure the thermal conductivity of a gripped object was designed and the software program using C language to discriminate objects made of different materials was developed. The temperature response characteristics of different materials on the same ambient temperature was investigated. The temperatures on three comparing points varied linearly and had parallel relation with one another in accordance with various ambient temperature.

  • PDF

The Powers and Interim Measures of the Arbitral Tribunal in International Commercial Arbitration (국제상사중재에서 중재판정부의 권한과 임시적 처분에 관한 연구)

  • Lee, Kang-Bin
    • Journal of Arbitration Studies
    • /
    • v.18 no.2
    • /
    • pp.103-127
    • /
    • 2008
  • This paper is to research the powers and interim measures of the arbitral tribunal in the arbitral proceedings of the international commercial arbitration under arbitration legislation and arbitration rules including the UNCITRAL Model Law and Arbitration Rules. The powers of the arbitral tribunal may be found within the arbitration agreement or any arbitration rules chosen by the parties, or the chosen procedural law. The power of the arbitral tribunal to decide its own jurisdiction is one of the fundamental principles of international commercial arbitration. It is a power which is now found in nearly all modern arbitration and rules of arbitration. Where an arbitral tribunal has been appointed then it will usually have the power to proceed with the arbitration in the event that a party fails to appear. It cannot force a party to attend but it may sanction the failure. While the arbitral tribunal can direct the parties to attend and give evidence the arbitral tribunal has no power to compel a party to give evidence. The arbitral tribunal may continue the arbitration in the absence of the party or its failure to submit evidence and make an award on the evidence before it. Under most of arbitration legislation and arbitration rules, the arbitral tribunal has the power to appoint experts and obtain expert evidence. The power to order a party to disclose documents in its possession is a power given to the arbitral tribunal by many national laws and by most arbitration rules. The arbitral tribunal cannot, however, compel disclosure and in the case where a party refuses to disclosure documents then the sanctions that the arbitral tribunal can impose must be ascertained from the applicable rules or the relevant procedural law. A number of arbitration rules and national laws allow for the arbitral tribunal to correct errors within the award. Most of arbitration legislation and arbitration rules permit the arbitral tribunal to grant orders for interim measure of protection. Article 17(1) of the Revised UNCITRAL Model Law of 2006 states: Unless otherwise agreed by the parties, the arbitral tribunal may, at the request of a party, grant interim measures. Interim measures of protection usually take such forms as (1) conservatory measures intended to prevent irreparable damage and maintain the status quo; (2) conservatory measures intended to preserve evidence or assets. Orders for interim measures by the arbitral tribunal are not self-enforcing. However, the arbitral tribunal must have the powers necessary to make interim measures effective. The Article 17 B of the Revised UNCITRAL Model Law of 2006 provides applications for preliminary orders and conditions for granting preliminary orders. And the Article 17 H provides recognition of enforcement of interim measures. In conclusion, the revised articles with regard to interim measures of the UNCITRAL Model Law of 2006 would contribute significantly to the security of the effectiveness of interim measures in international commercial arbitration. Therefore, Korean Arbitration Law and Arbitration Rules would be desirable to admit such revised articles with regard interim measures.

  • PDF

Some considerations for the analytical approaches to measure atmospheric ammonia: tests on a relative performance of a portable colorimeter against UV/VIS spectrophotometer (대기 중 암모니아 성분의 분석법 연구: UV/VIS 분광계를 이용한 간이비색계의 상대 성능평가)

  • Kim, K.H.;Park, S.Y.;Kim, S.T.
    • Analytical Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.425-430
    • /
    • 2005
  • In this study, we investigated the performance of a portable colorimeter used for the measurements of atmospheric ammonia against the more reliable method like UV/VIS spectrophotometer. For the purpose of this study, we tested a portable colorimeter and UV/VIS spectrophotometer for such basic analytical parameters as detectibility, reproducibility, linearity, and accuracy. According to our study, the performance of the colorimeter was fairly good to show a good agreement with the UV/VIS system. However, the performance of colorimeter suffered from both low and high concentration ranges: it was found to have very poor reproducibility at lower concentration (below $10\mu}g$), while its linear dynamic range was limited at the upper end (e.g., near $100{\mu}g$). If we assume that air samples are collected up to 30 liter, it implies that the colorimeter can be used to measure samples containing NH3 in the range of 500 ppb to 5 ppm (without the aid of diluting technique). Consequently, we recommend the use of such instrument with the awareness of its basic properties pertaining to the fundamental performance (such as its detectable range).

Numerical Modelling of Typhoon-Induced Storm Surge on the Coast of Busan (부산 연안에서 태풍에 의한 폭풍해일의 수치모델링)

  • Cha-Kyum Kim;Tae-Soon Kang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.760-769
    • /
    • 2023
  • A numerical simulations were performed to investigate the storm surge during the passage of Typhoon Maemi on the coast of Busan. The typhoon landed on the southern coasts of Korean Peninsula at 21:00, September 12, 2003 with a central pressure of 950 hPa, and the typhoon resulted on the worst coastal disaster on the coast of Busan in the last decades. Observed storm surges at Busan, Yeosu, Tongyoung, Masan, Jeju and Seogwipo harbors during the passage of the typhoon were compared with the computed data. The simulated storm surge time series were in good agreement with the observations. The simulated peak storm surges were estimated to be 230 cm at Masan harbor, 200 cm at Yeosu harbor and Tongyoung harbor, and 75 cm at Busan harbor. The computed storm surges along the east coast of Busan measure 52 to 55 cm, exhibiting a gradual reduction in surge height as one moves further from the coast of Busan. Therefore, coastal inundation due to the storm surge in the semi-enclosed bay can induce great disasters, and the simulated results can be used as the important data to reduce the impact of a typhoon-induced coastal disaster in the future.

Copper Isotope Measurements Using a Neptune MC-ICP-MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 구리 동위원소 분석법)

  • Park, Sanghee;Ryu, Jong-Sik;Shin, Hyung Seon;Kil, Youngwoo;Jo, Yunsoo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.29 no.4
    • /
    • pp.221-227
    • /
    • 2016
  • Copper is an essential transition metal involving in various biogeochemical processes. With the recent advances in analytical techniques and mass spectrometry, such as MC-ICP-MS, it is possible to measure Cu isotopes, which allows us to understand various biogeochemical processes in detail. Nonetheless, few studies have been performed in South Korea. In this study, we compared two purification methods previously reported using an anion exchange resin ($AG^{(R)}$ MP-1M), developed the best method in our lab environment, and then verified it by measuring Cu isotopic compositions in two USGS geological reference materials (BHVO-2 and BIR-1a). Although all matrix cations causing mass bias were effectively removed through both two methods with the yield of better than 95%, the method using the mixture of HCl and $H_2O_2$ only displays Cu isotopic compositions, in excellent agreement with reported values within the error. The method developed in this study is expected to be commonly applied to earth and environmental sciences.

Numerical Investigation of Ion and Radical Density Dependence on Electron Density and Temperature in Etching Gas Discharges (식각공정용 가스방전에서 이온 및 활성종 밀도의 전자밀도 및 온도 의존성에 대한 수치해석적 분석)

  • An, Choong-Gi;Park, Min-Hae;Son, Hyung-Min;Shin, Woo-Hyung;Kwon, Deuk-Chul;You, Shin-Jae;Kim, Jung-Hyung;Yoon, Nam-Sik
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.6
    • /
    • pp.422-429
    • /
    • 2011
  • Dependence of radical and ion density on electron density and temperature is numerically investigated for $Cl_2$/Ar, $CF_4$, $CF_4/O_2$, $CF_4/H_2$, $C_2F_6$, $C_4F_8$ and $SF_6$ discharges which are widely used for etching process. We derived a governing equation set for radical and ion densities as functions of the electron density and temperature, which are easier to measure relatively, from continuity equations by assuming steady state condition. Used rate coefficients of reactions in numerical calculations are directly produced from collisional cross sections or collected from various papers. If the rate coefficients have different values for a same reaction, calculation results were compared with experimental results. Then, we selected rate coefficients which show better agreement with the experimental results.

Measurements of Dissociation Enthalpy for Simple Gas Hydrates Using High Pressure Differential Scanning Calorimetry (고압 시차 주사 열량계를 이용한 단일 객체 가스 하이드레이트의 해리 엔탈피 측정)

  • Lee, Seungmin;Park, Sungwon;Lee, Youngjun;Kim, Yunju;Lee, Ju Dong;Lee, Jaehyoung;Seo, Yongwon
    • Korean Chemical Engineering Research
    • /
    • v.50 no.4
    • /
    • pp.666-671
    • /
    • 2012
  • Gas hydrates are inclusion compounds formed when small-sized guest molecules are incorporated into the well defined cages made up of hydrogen bonded water molecules. Since large masses of natural gas hydrates exist in permafrost regions or beneath deep oceans, these naturally occurring gas hydrates in the earth containing mostly $CH_4$ are regarded as future energy resources. The heat of dissociation is one of the most important thermal properties in exploiting natural gas hydrates. The accurate and direct method to measure the dissociation enthalpies of gas hydrates is to use a calorimeter. In this study, the high pressure micro DSC (Differential Scanning Calorimeter) was used to measure the dissociation enthalpies of methane, ethane, and propane hydrates. The accuracy and repeatability of the data obtained from the DSC was confirmed by measuring the dissociation enthalpy of ice. The dissociation enthalpies of methane, ethane, and propane hydrates were found to be 54.2, 73.8, and 127.7 kJ/mol-gas, respectively. For each gas hydrate, at given pressures the dissociation temperatures which were obtained in the process of enthalpy measurement were compared with three-phase (hydrate (H) - liquid water (Lw) - vapor (V)) equilibrium data in the literature and found to be in good agreement with literature values.