• 제목/요약/키워드: Maximal Surfaces

검색결과 35건 처리시간 0.024초

최대볼륨분해 방법을 이용한 중립면 모델의 자동생성 (Automatic Generation of Mid-Surfaces of Solid Models by Maximal Volume Decomposition)

  • 우윤환;주창업
    • 한국CDE학회논문집
    • /
    • 제14권5호
    • /
    • pp.297-305
    • /
    • 2009
  • Automatic generation of the mid-surfaces of a CAD model is becoming a useful function in that it can help increase the efficiency of engineering analysis as far as it does not affect the result seriously. Several methods had been proposed previously to automatically generate the mid-surfaces, but they often failed to generate the mid-surfaces of complex CAD models. Due to the inherent difficulty of this mid-surface generation problem, it may not be possible to come up with a complete and general method to solve this problem. Since a method that can handle a specific case may not work for different cases, it seems that developing case-specific methods ends up with solving only a fraction of the problem. In this paper, therefore, we propose a method to generate mid-surfaces based on a divide-and-conquer paradigm. This method first decomposes a complex CAD model into simple volumes. The mid-surfaces of the simple volumes are automatically generated by the existing methods, and then they are converted into the mid-surfaces of the original CAD model.

Development of New Reverse Micellar Microencapsulation Technique to Load Water-Soluble Drug into PLGA Microspheres

  • Kim Hyun Joo;Cho Mi Hyun;Sah Hong Kee
    • Archives of Pharmacal Research
    • /
    • 제28권3호
    • /
    • pp.370-375
    • /
    • 2005
  • The objective of this study was to develop a new reverse micelle-based microencapsulation technique to load tetracycline hydrochloride into PLGA microspheres. To do so, a reverse micellar system was formulated to dissolve tetracycline hydrochloride and water in ethyl formate with the aid of cetyltrimethylammonium bromide. The resultant micellar solution was used to dissolve 0.3 to 0.75 g of PLGA, and microspheres were prepared following a modified solvent quenching technique. As a control experiment, the drug was encapsulated into PLGA microspheres via a conventional methylene chloride-based emulsion procedure. The micro­spheres were then characterized with regard to drug loading efficiency, their size distribution and morphology. The reverse micellar procedure led to the formation of free-flowing, spherical microspheres with the size mode of 88 ~m. When PLGA microspheres were prepared follow­ing the conventional methylene chloride-based procedure, most of tetracycline hydrochloride leached to the aqueous external phase: A maximal loading efficiency observed our experimental conditions was below $5\%$. Their surfaces had numerous pores, while their internal architecture was honey-combed. In sharp contrast, the new reverse micellar encapsulation technique permitted the attainment of a maximal loading efficiency of 63.19 $\pm$$0.64\%$. Also, the microspheres had smooth and pore-free surfaces, and hollow cavities were absent from their internal matrices. The results of this study demonstrated that PLGA microspheres could be successfully prepared following the new reverse micellar encapsulation technique.

SINGULAR AND MARCINKIEWICZ INTEGRAL OPERATORS ON PRODUCT DOMAINS

  • Badriya Al-Azri;Ahmad Al-Salman
    • 대한수학회논문집
    • /
    • 제38권2호
    • /
    • pp.401-430
    • /
    • 2023
  • In this paper, we prove Lp estimates of a class of singular integral operators on product domains along surfaces defined by mappings that are more general than polynomials and convex functions. We assume that the kernels are in L(log L)2 (𝕊n-1 × 𝕊m-1). Furthermore, we prove Lp estimates of the related class of Marcinkiewicz integral operators. Our results extend as well as improve previously known results.

COMPLETE MAXIMAL SPACE-LIKE HYPERSURFACES IN AN ANTI-DE SITTER SPACE

  • Choi, Soon-Meen;Ki, U-Hang;Kim, He-Jin
    • 대한수학회보
    • /
    • 제31권1호
    • /
    • pp.85-92
    • /
    • 1994
  • It is well known that there exist no closed minimal surfaces in a 3-dimensional Euclidean space R$^{3}$. Myers [4] generalized the result to the case of the higher dimension and proved that there are no closed minimal hypersurfaces in an open hemisphere. The complete and non-compact version concerning Myers' theorem is recently considered by Cheng [1] and the following theorem is proved.

  • PDF

Lower Bounds on Boundary Slope Diameters for Montesinos Knots

  • Ichihara, Kazuhiro;Mizushima, Shigeru
    • Kyungpook Mathematical Journal
    • /
    • 제49권2호
    • /
    • pp.321-348
    • /
    • 2009
  • In this paper, we give two lower bounds on the diameter of the boundary slope set of a Montesinos knot. One is described in terms of the minimal crossing numbers of the knots, and the other is related to the Euler characteristics of essential surfaces with the maximal/minimal boundary slopes.

A Note on Marcinkiewicz Integral Operators on Product Domains

  • Badriya Al-Azri;Ahmad Al-Salman
    • Kyungpook Mathematical Journal
    • /
    • 제63권4호
    • /
    • pp.577-591
    • /
    • 2023
  • In this paper we establish the Lp boundedness of Marcinkiewicz integral operators on product domains with rough kernels satisfying a weak size condition. We assume that our kernels are supported on surfaces generated by curves more general than polynomials and convex functions. This generalizes and extends previous results.

공기압 차이에 따른 불안정지지면이 다리 근활성도에 미치는 영향 (Effect of Inflatable Standing Surface With Different Levels of Air Pressure on Leg Muscle Activity)

  • 박치복;김용남;김용성;조운수;진희경
    • 한국전문물리치료학회지
    • /
    • 제20권2호
    • /
    • pp.1-10
    • /
    • 2013
  • The purpose of this study was to determine the effect of the changes that occur in the leg muscle activity of unstable surface with different levels of air pressures. Three groups of college students have been placed randomly on unstable surfaces with different air pressures at group 1.0 psi ($n_1$=36), group 1.4 psi ($n_2$=40), and group 1.8 psi ($n_3$=40). Using surface electromyography, the recruitment of the tibialis anterior, peroneus longus, and the gastrocnemius was measured. Maximal voluntary isometric contraction was measured at the different air pressures based on the manual muscle test, then normalizing the value to %maximal voluntary isometric contraction (%MVIC). The tibialis anterior muscle activity was significant change from the unstable surface with difference levels of air pressures between group 1.0 psi and 1.8 psi and between group 1.4 psi and 1.8 psi. peroneus longus muscle activity was significant changes in muscle activity occurred between 1.0 psi and 1.4 psi group and between 1.0 psi and 1.8 psi group. Gastrocnemius muscle activity was significant change in muscle activity occurred between 1.0 psi and 1.4 psi group and between 1.0 psi and 1.8 psi group. In conclusion it identify that 1.0 psi group is most effective on muscle activity than the other groups. These suggest that the rehabilitation or strengthening of patients with ankle injuries, balance exercise with low air pressure like 1.0 psi can be more effective.

혈소판 농축 혈장과 혼합된 자가골 및 이종골 이식재가 치주 조직의 재생에 미치는 효과 (A Comparative Study of the effects of Autogenous and Xenogenic Bone grafts with PRP(Platelet Rich Plasma) technique on Periodontal Regeneration)

  • 김동기;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제34권3호
    • /
    • pp.499-508
    • /
    • 2004
  • Regeneration of Periodontium with PRP does not only improve regeneration rate and density of bone but have a possibility to estimate faster healing process for soft tissue. And also, autogenous bone and xenogenic bone graft are effective on regeneration of periodontium. The purpose of this study is to evaluate the effectiveness of autogenous bone and xenogenic bone $(BBP^{(R)})$ grafts with the PRP technique on regeneration of periodontium. 52 Generally healthy Pt. who had pocket depth 5mm at any of 6 surfaces of the teeth were in the study at Dept. of Perio. in Dankook Dental Hospital. Open Flap was treated for 18 infra-bony pockets as control group, autogenous bone with PRP was inserted for 25 infrabony pockets as first test group, and $(BBP^{(R)})$ with PRP was inserted for 22 infrabony pockets as 2nd test group. Then evaluation was made after 3 and 6 months 1. There were significant differences between average probing pocket depth and clinical attachment level of 3, 6 months and minimal and maximal attachment level after 6 months each other. 2. There were significant differences in average probing pocket depth of control group and 2nd experimental group between 1 and 6 months. For clinical attachment level and minimal and maximal proving attachment level, there was a significant difference after 6 month of surgery. 3. There was no significant difference between two test groups for average probing depth, clinical attachment level, and minimal and maximal probing attachment level. As the result, PRP with bone graft could be very effective for regeneration of periodontium and there was no difference between xenogenic bone and autogenous bone.

Failure Mechanism of Cu/PET Flexible Composite Film with Anisotropic Interface Nanostructure

  • Park, Sang Jin;Han, Jun Hyun
    • 한국재료학회지
    • /
    • 제30권3호
    • /
    • pp.105-110
    • /
    • 2020
  • Cu/PET composite films are widely used in a variety of wearable electronics. Lifetime of the electronics is determined by adhesion between the Cu film and the PET substrate. The formation of an anisotropic nanostructure on the PET surface by surface modification can enhance Cu/PET interfacial adhesion. The shape and size of the anisotropic nanostructures of the PET surface can be controlled by varying the surface modification conditions. In this work, the effect of Cu/PET interface nanostructures on the failure mechanism of a Cu/PET flexible composite film is studied. From observation of the morphologies of the anisotropic nanostructures on plasma-treated PET surfaces, and cross-sections and surfaces of the fractured specimens, the Cu/PET interface area and nanostructure width are analyzed and the failure mechanism of the Cu/PET film is investigated. It is found that the failure mechanism of the Cu/PET flexible composite film depends on the shape and size of the plasmatreated PET surface nanostructures. Cu/PET interface nanostructures with maximal peel strength exhibit multiple craze-crack propagation behavior, while smaller or larger interface nanostructures exhibit single-path craze-crack propagation behavior.