• 제목/요약/키워드: Mass measurement type

검색결과 156건 처리시간 0.032초

Design and manufacture of horn lens antennas of 80 GHz MM wave FMCW radar for cryogenic fluids level measurement

  • Jeon, S.M.;Mun, J.M.;Lee, S.C.;Sim, K.D.;Kim, S.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제24권1호
    • /
    • pp.29-33
    • /
    • 2022
  • Recently, development of a cryogenic fluids storage tank for storing or transporting liquid hydrogen is actively in progress. In cryogenic fluids storage tanks, hydrogen evaporates due to the extreme temperature difference inside and outside the tank. As the mass of the cryogenic fluids changes with continuous vaporization, the fluids level also changes. Therefore, there is need for a method of accurately measuring the level change in the storage tank. In the case of general cryogenic fluids, it is difficult to accurately measure the level because the dielectric constant is very low. As a method of measuring cryogenic fluids level with low dielectric constant, it can be used an Millimeter wave (MM wave) FMCW radar sensor. However, the signal sensitivity is very weak and the level accuracy is poor. In this paper, the signal sensitivity is improved by designing the horn lens antenna of the existing 80 GHz FMCW radar sensor. Horn lens antenna is fabricated by FDM/SLA type 3D printer according to horn and lens characteristics. The horn is used to increase the signal gain and the lens improves the signal straightness. This makes it possible to measure the level of cryogenic fluids with a low dielectric constant.

Fabrication of Nickel-based Piezoelectric Energy Harvester from Ambient Vibration with Micromachining Technology (마이크로 머시닝 기술을 이용한 니켈기반의 압전 진동형 에너지 하베스터 제작)

  • Cha, Doo-Yeol;Lee, Jai-Hyuk;Chang, Sung-Pil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제25권1호
    • /
    • pp.62-67
    • /
    • 2012
  • Owing to the rapid growth of mobile and electronic equipment miniaturization technology, the supply of micro mobile computing machine has been fast raised. Accordingly they have performed many researches on energy harvesting technology to provide promising power supply equipment to substitute existing batteries. In this paper, in order to have low resonance frequency for piezoelectric energy harvester, we have tried to make it larger than before by adopting nickel that has much higher density than silicon. We have applied it for our energy harvesting actuator instead of the existing silicon based actuator. Through such new concept and approach, we have designed energy harvesting device and made it personally by making with micromachining process. The energy harvester structure has a cantilever type and has a dimension of $10{\times}2.5{\times}0.1\;mm^3$ for length, width and thickness respectively. Its electrode type is formed by using Au/Ti of interdigitate d33 mode. The pattern size and gap size is 50 ${\mu}m$. Based on the measurement of the nickel-based piezoelectric energy harvester, it is found to have 778 Hz for a resonant frequency with no proof mass. In that resonance frequency we could get a maximum output power of 76 ${\mu}W$ at 4.8 $M{\Omega}$ being applied with 1 g acceleration.

Measurement of Ground Reaction Force and Energy Consumption for Ankle Assembly (Fixed-axis , Single-axis , Multi-axis Type) of Trans-Tibial Amputee (하퇴의지착용자에 대한 인공족관절 유형(고정형, 단축형, 다축형)에 따른 지면반발력 및 에너지 소모의 측정)

  • 김성민;배하석;박창일
    • Journal of Biomedical Engineering Research
    • /
    • 제22권6호
    • /
    • pp.543-550
    • /
    • 2001
  • In this study, ground reaction force(GRF) and energy consumption of fixed. single-axis and multi-axis Prosthetic ankle assemblies were investigated to show the biomechanical evaluation for trans-tibial amputees. In the experiments. two male and two female trans-tibial amputees were tested with fixed, sin91e-axis and multi-axis Prosthetic ankle assembly. A three-dimensional gait analysis was carried out to derive the ratio of GRF to weight as the percentage of total stance Phase for nine Points Energy consumption of each Prosthetic ankle assembly was measured while subjects walked at 2km/h. 3km/h and the most comfortable walking speed on the treadmill The results showed that multi-axis ankle was superior to the other two ankle assemblies for the characteristic of forwarding and breaking forces. Fixed ankle was relatively superior to the other two ankle assemblies for gait balancing and movement of the center fur mass Compared to the other ankle assembly. sing1e-axis type showed lower energy consumption over 2.3km/h walking speed .

  • PDF

Study on the degradation rate and pH change of PLGA membrane with a biodegradation (생분해에 따른 PLGA 멤브레인의 분해속도 및 pH 변화에 대한 연구)

  • Xie, Yuying;Park, Jong-Soon;Kang, Soon-Kook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제16권9호
    • /
    • pp.6403-6410
    • /
    • 2015
  • Medical polymer PLGA is biocompatible, biodegradation, mechanical characteristic and biostability, and the degradation time can be adjust by controlling the number of monomer. In this paper, PLGA membranes have different composition ratio by L/D type was prepared by phase transition method. And the PLGA membrane in phosphate buffered saline(PBS) at the different test temperatures for different periods of time to examined for change in mass and measured the pH of degradation media. Measurement of Tg and surface structure was performed using a DSC and Stereoscopic microscope. As the molecular weighter increase, hydrolysis rate was decrease in geometrical progression. According to the composition ratio by L/D type, degradation rate and the change of pH are large.

Investigation of O4 Air Mass Factor Sensitivity to Aerosol Peak Height Using UV-VIS Hyperspectral Synthetic Radiance in Various Measurement Conditions (UV-VIS 초분광 위성센서 모의복사휘도를 활용한 다양한 관측환경에서의 에어로솔 유효고도에 대한 O4 대기질량인자 민감도 조사)

  • Choi, Wonei;Lee, Hanlim;Choi, Chuluong;Lee, Yangwon;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • 제36권2_1호
    • /
    • pp.155-165
    • /
    • 2020
  • In this present study, the sensitivity of O4 Air Mass Factor (AMF) to Aerosol Peak Height (APH) has been investigated using radiative transfer model according to various parameters(wavelength (340 nm and 477 nm), aerosol type (smoke, dust, sulfate), aerosol optical depth (AOD), surface reflectance, solar zenith angle, and viewing zenith angle). In general, it was found that O4 AMF at 477 nm is more sensitive to APH than that at 340 nm and is stably retrieved with low spectral fitting error in Differential Optical Absorption Spectroscopy (DOAS) analysis. In high AOD condition, sensitivity of O4 AMF on APH tends to increase. O4 AMF at 340 nm decreased with increasing solar zenith angle. This dependency isthought to be induced by the decrease in length of the light path where O4 absorption occurs due to the shielding effect caused by Rayleigh and Mie scattering at high solar zenith angles above 40°. At 477 nm, as the solar zenith angle increased, multiple scattering caused by Rayleigh and Mie scattering partly leads to the increase of O4 AMF in nonlinear function. Based on synthetic radiance, APHs have been retrieved using O4 AMF. Additionally, the effect of AOD uncertainty on APH retrieval error has been investigated. Among three aerosol types, APH retrieval for sulfate type is found to have the largest APH retrieval error due to uncertainty of AOD. In the case of dust aerosol, it was found that the influence of AOD uncertainty is negligible. It indicates that aerosol types affect APH retrieval error since absorption scattering characteristics of each aerosol type are various.

A Comparison of Upper Body Sizes and Body Types of Women in Their 20s and 30s-40s - Identifying Problems Generated by Preferences of Women in Their 30s and 40s for Young Casual Brands - (20대와 30~40대 여성의 상반신 신체치수 및 체형 비교 연구 - 30, 40대 여성의 영캐주얼 브랜드 선호 현상에 따른 문제점 파악을 중심으로 -)

  • Kim, Eun-Kyong
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • 제18권2호
    • /
    • pp.15-33
    • /
    • 2016
  • Women in their 30s and 40s, who are at the center of "ageless" and "down-aging" consumer trends, are likely to encounter problems with fitting and size conformity when they wear casual clothes targeting women in their 20s. Hence, differences in upper body sizes and body types between women in their 20s and women in their 30s and 40s were analyzed. The data for this study was from the 6th Size Korea survey of body measurements of 1,675 female adults in their 20s-40s. SPSS 21.0 for Windows was used for analysis of the collected data. To examine differences in average upper body size between women in their 20s and women in their 30s and 40s, descriptive statistics and independent sample t-tests were conducted. Factor and cluster analyses were used to classify body types by age groups. Comparing direct measurement items showed that women in their 20s tend to have higher average values for most height-related items-including body height-and lower average values for circumference, thickness, and width than women in their 30s and 40s. Factors in determining the upper body shapes of women in their 20s to 40s were narrowed to five; through a cluster analysis, upper body shapes of women were classified into three body types as follows. Type 1 women are shorter and thinner with small frames; Type 2 women have the highest vertical values for their upper bodies and average values for obesity-related categories of circumference, thickness, and width. Type 3 women are the shortest and has the highest body mass index (BMI), verifiable as obese. By analyzing differences in body type distribution according to age groups, it was found that more than 90% of women in their 20s belong to Types 1 and 2. On the other hand, most women in their 30s and 40s are identified as Type 3.

  • PDF

Analysis on the TBM Penetration Rates in Extremely Hard Rocks (극경암에서의 전단면터널 굴착속도 분석연구)

  • Park, Chul-Whan;Synn, Joong-Ho;park, Chan;Kim, Min-Kyu;Chung, So-Keul;Kim, Hwa-Soo
    • Tunnel and Underground Space
    • /
    • 제10권4호
    • /
    • pp.526-532
    • /
    • 2000
  • The uniaxial compressive strength of rock mass is known as the major factor in the assessment of drillability and the optimum excavation design in full-face tunnel excavation by TBM. Referring to worldwide cases, TBM has been applied mostly to the rock mass within the strength range of 80~250 MPa. Recently, a water way tunnel has been constructed as a part of Milyang dam project by TBM within the rock masses where the rock type is mainly granite with some granophyre, hornfels and andesite. Their uniaxial compressive strengths in extended area are estimated higher than 260 MPa. In this paper, the relation between the penetration rate and the rock mass properties is analyzed and TBM application to the very hard rocks is discussed. As a result that three suggestions to predict the TBM net penetration rate are analyzed, NTH method seems a better approach than other methods in the extremely hard rocks. NTH prediction matches with the results of actual values with the variations of 2~20%. Hardness measurement by Schmidt hammer and RMR estimation are carried out along the L = 5.3 km entire TBM tunnel alignment. The net penetration rate measured monthly is shown to be reciprocally proportional to Schmidt rebound hardness and RMR where coefficients of correlation, $R^2$are 0.705 and 0.777 respectively. As a result, they are good quantitative indices for the prediction of TBM net penetration rate in the extremely hard rocks. Magnitude of in-situ stress has a certain effect on TBM performance, and it is required to measure the in-situ stresses in TBM excavation design.

  • PDF

Dissolved Methane Measurements in Seawater and Sediment Porewater Using Membrane Inlet Mass Spectrometer (MIMS) System (Membrane Inlet Mass Spectrometer (MIMS) 시스템을 이용한 해수 및 퇴적물 공극수내 용존 메탄의 측정)

  • An, Soon-Mo;Kwon, Ji-Nam;Lim, Jea-Hyun;Park, Yun-Jung;Kang, Dong-Jin
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • 제12권3호
    • /
    • pp.244-250
    • /
    • 2007
  • Membrane inlet mass spectrometer (MIMS) has been used to accurately quantify dissolved gases in liquid samples. In this study, the MIMS system was applied to measure dissolved methane in seawater and sediment porewater. To evaluate the accuracy of the measurement, liquid samples saturated with different methane partial pressure were prepared and the methane concentrations were quantified with the MIMS system. The measured values correspond well with the expected values calculated from solubility constants. The standard error of the measurements were $0.13{\sim}0.9%$ of the mean values. The distribution of dissolved methane concentration in seawater of the South Sea of Korea revealed that the physical parameters primarily control the methane concentration in sea water. The MIMS system was effective to resolve the small dissolved methane difference among water masses. The probe type inlet in MIMS system was proven to be effective to measure porewater methane concentration.

The Effects of Short Term Comprehensive Life Style Modification Program on Glycemic Metabolism, Lipid Metabolism and Body Composition in Type 2 Diabetes Mellitus (단기간의 포괄적인 생활습관개선 프로그램이 제2형 당뇨병환자의 당대사 및 지질대사와 체구성에 미치는 효과)

  • Yoo Ji Soo;Lee Suk Jeong;Lee Hyun Chul;Kang Eun Seok;Kim So Hun;Park Eun Jeong
    • Journal of Korean Academy of Nursing
    • /
    • 제34권7호
    • /
    • pp.1277-1287
    • /
    • 2004
  • Purpose: This study was to evaluate the effects of a short term comprehensive life style modification program on glycemic metabolism, lipid metabolism and body composition in type 2 diabetes mellitus patients. Method: A nonequivalent control group with a pre post test was designed. Data collection was done from October 2003 to June, 2004 at a hospital. Glycemic metabolism was measured by a.c., p.c. and $HbA_{1}c$, and lipid metabolism was measured by cholesterol, HDL cholesterol, LDL cholesterol and triglycerides. Body Composition was measured by body weight, body mass index, waist, measurement waist per hip ratio, body fat, muscle weight and abdominal fat tissue(intra abdominal distance). The Experimental group, which was composed of 29 participants, was educated based on a life style modification protocol at a weekly meeting for 12 weeks and carried out exercise, diet along individual parameters and self monitoring, while 24 participants in the control group received only diet education. Result: 1. The experimental group showed a significant lower a.c.(t=2.11, p=.04) and $HbA_{1}c$(t=2.65, p=.01) compared to those of the control group. 2. The experimental group showed a significant lower LDL than the results of the control group(t=2.42, p=.02). 3. The experimental group showed a significant lower weight(t=3.09, p=.00), BMI(t=3.01, p=.00), body fat(t=2.94, p=.01) and abdominal fat tissue(t=3.05, p=.01) than those of the control group. Conclusion: The results provided evidence for the effectiveness of a short term comprehensive life style modification program composed of exercise, diet, support, self efficacy elevation and self monitoring in type 2 diabetes mellitus.

The Effects of Regulatory Exercise on Adipokines and Inflammatory Reaction in Type 1 Diabetic and Obese Children (규칙적인 운동이 제1형 당뇨병 및 비만 환아의 아디포카인과 염증반응에 미치는 영향)

  • Kang, Sung-Hwun;Shin, Ki-Ok;Park, So-Young;Woo, Jin-Hee
    • Journal of Life Science
    • /
    • 제20권7호
    • /
    • pp.1066-1072
    • /
    • 2010
  • The purpose of this study was to investigate the effects of aerobic exercise on adipokines and inflammatory reaction in obesity and type 1 diabetes mellitus (T1DM) children. We studied obese (OG, n=9), type 1 diabetic (DG, n=9), and normal (NG, n=9) children groups. Measurement factors included body weight, % fat, body mass index (BMI), $VO_2max$, lipid profiles and adipokines. The results showed significant differences in body weight, % fat, BMI, and $VO_2max$ (ml/kg/min) among the OG, DG, and NG (p<0.05) groups. There were significant differences in LDL-C and HDL-C between the OG, DG, and NG groups (p<0.05). In addition, adiponectin and retinol binding protein (RBP)-4 were significantly changed in DG and NG after 12 weeks exercise training (p<0.05), and there were also significant differences among the OG, DG, and NG groups (p<0.05). Monocyte chemoattractant protein (MCP)-1 in the OG, DG, and NG groups was significantly increased after 12 weeks exercise training (p<0.05). In conclusion, regulatory aerobic exercise does not change body composition in obese children with T1DM, but exercise and decreased blood inflammatory factors in T1DM may protect obese children from metabolic syndrome.