• 제목/요약/키워드: Marginal Fitness

검색결과 56건 처리시간 0.034초

레이저선택용융기술에 의해 제작된 금속 코어의 변연 적합도 분석 (An analysis of marginal adaptation of metal cores fabricated by selective laser sintering)

  • 김원수;김기백
    • 대한치과기공학회지
    • /
    • 제38권4호
    • /
    • pp.305-311
    • /
    • 2016
  • Purpose: The purpose of this study were to analysis of marginal adaptation of metal cores fabricated by selective laser sintering. Methods: Main model was prepared and ten stone models were fabricated. Ten single metal cores were fabricated by selective laser sintering(SLS group) and another ten single metal cores using lost wax technique and casting method were manufactured(CAST group). The marginal adaptation of metal cores were analysis using by the silicone replica technique. Silicone replicas were sectioned two times. The marginal adaptations were measured using by digital microscope. Statistical analyses was performed with independent t-test(${\bullet}{\cdot}=0.05$). Results: Means of marginal adaptations were 90.3 ${\ss}{\uparrow}$ for SLS group and 65.1 ${\ss}{\uparrow}$ for CAST group. Two groups were statistically significant differences (p < 0.05). Conclusion: Marginal adaptation of metal cores fabricated by selective laser sintering were ranged within the clinical recommendation.

Extraoral scanner와 intraoral scanner를 이용하여 제작된 zirconia crown의 2차원 변연 및 내면 적합도 비교: in vitro (Comparison of 2-dimensional marginal and internal fitness for the monolithic zirconia prosthesis using intraoral scanner and extraoral scanner: in vitro)

  • 이태희;이하빈;김지환
    • 대한치과기공학회지
    • /
    • 제41권3호
    • /
    • pp.187-193
    • /
    • 2019
  • Purpose: The purpose of this study was to compare two-dimensional fitness of the monolithic zirconia prosthesis by using different type of scanner. Methods: No. 26 abutment tooth of FDI system was selected for the study. Using the extraoral scanner and intraoral scanner, the abutment tooth was scanned 10 times and the scanned files were saved as STL files. CAD/CAM system was used to produce the monolithic zirconia prosthesis. marginal and internal gap of the monolithic zirconia prosthesis were measured by digital microscope(x160) and applied silicone replica technique was applied. t-test, a statistical software, was used to perform data analysis. Results: Marginal gap $mean{\pm}SD$ of the monolithic zirconia prosthesis was $33{\pm}7.5{\mu}m$ with extra oral scanner and $34.7{\pm}11.1{\mu}m$ with intraoral scanner. axial gap mean was $40.5{\pm}3.5{\mu}m$ with extra oral scanner and $44.6{\pm}11.6{\mu}m$ with intraoral scanner. occlusal gap mean was $110.1{\pm}25.4{\mu}m$ with extra oral scanner and $64{\pm}9.7{\mu}m$ with intraoral scanner. Conclusion: In this study, fabricating zirconia prosthesis with different type of scanner was clinically applicable.

CAD/CAM 시스템으로 제작한 지로코니아 코어의 변연 적합도 평가 (Evaluation on the Marginal Fitness of Zirconia Core fabricated with CAD/CAM System)

  • 노형록;선금주;주규지
    • 한국콘텐츠학회논문지
    • /
    • 제13권11호
    • /
    • pp.800-806
    • /
    • 2013
  • 본 연구의 목적은 CAD/CAM 시스템을 이용하여 지르코니아 코어를 제작한 다음 span의 길이가 변연 적합도에 미치는 영향과, 변연 간격이 임상적으로 허용 가능한 범위 내에 있는지를 평가하였다. 실험군은 지르코니아 single crown, 2-unit bridge, 3-unit bridge, 4-unit bridge의 4그룹으로 나누고 각 그룹별로 10개씩 코어를 제작하였다. 평균 변연 간격은 single $42.95{\pm}6.93{\mu}m$, 2-unit $43.53{\pm}5.27{\mu}m$, 3-unit $53.43{\pm}13.38{\mu}m$, 4-unit $50.85{\pm}8.25{\mu}m$으로 나타났다. 근심면, 원심면에서는 single, 2-unit 그룹과 3-unit, 4-unit 그룹 간 span의 길이 요인에 따라 통계학적으로 유의한 차이가 있는 것으로 나타났다(p<.05). 협면, 설면에서는 모든 그룹에서 span의 길이 요인에 따라 통계학적으로 유의한 차이가 없었다(p>.05). 이러한 결과는 지르코니아 코어의 span 길이가 변연 적합도에 영향을 주었고, 변연간격은 모든 그룹에서 임상적 허용 범위 내에 존재 하였다.

Co-Cr-Ti 합금으로 제작한 conical telescope 외관의 변연적합도와 유지력에 관한 연구 (MARGINAL DISCREPANCY AND RETENTION FORCE OF CONICAL TELESCOPE OUTER CROWN WITH CO-CR-TI ALLOY)

  • 정희찬;정창모;전영찬;임장섭
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.214-225
    • /
    • 2000
  • The purpose of this study was to investigate the effects of investing conditions on the marginal discrepancy of conical telescope outer crown with Co-Cr-Ti alloy(Dentitan) and to compare the marginal discrepancy and the retention force of outer crowns using different pattern materials(plastic foil, casting wax, pattern resin). To evaluate the effects of investing conditions on the marginal discrepancy, patterns with plastic foil were invested under three different liquid/powder ratio conditions using phosphate bonded investment(Univest-nonprecious): standard, 10% decreased and 10% increased. At each liquid/powder ratio condition, metal ring was lined with single or double layers of ceramic ring liner. The marginal discrepancy of outer crown at different investing conditions was measured by ${\times}100$ compact measuring microscope(STM5, Olympus, Japan). For measurement of the marginal discrepancy and the retention force of outer crown using different pattern materials, the investing condition of 10% decreased liquid/powder ratio and double layers of ring liner was selected because this investing condition resulted in the best fit of outer crown. Marginal discrepancy was measured in the same way above and retention force on universal testing machine. Under the conditions of this study, the following conclusions were drawn: 1. The thickness of ring liner had more influence on the marginal discrepancy of outer crown than the liquid/powder ratio, and the acceptable marginal fitness could not be expected at the investing condition directed by investment manufacturer 2. There were no differences in the marginal discrepancy of outer crown among three different pattern materials(P>0.05). 3. Casting wax showed the greatest retention force(1640g) of outer crown, followed by pattern resin(1110g), plastic foil(820g). However, there was no significant difference between plastic foil and pattern resin(P>0.05). 4. Plastic foil showed the least variation in marginal discrepancy and retention force.

  • PDF

다양한 CAD/CAM 시스템으로 제작된 3 본 고정성 가공의치 지르코니아 코어의 변연 및 내면 적합도 평가 (Marginal and internal fitness of three-unit zirconia cores fabricated using several CAD/CAM systems)

  • 허중보;김우식;김하영;김종은;이정렬;김영수;전영찬;신상완
    • 대한치과보철학회지
    • /
    • 제49권3호
    • /
    • pp.236-244
    • /
    • 2011
  • 연구 목적: 본 연구는 다양한 CAD/CAM 시스템에 의해 제작된 지르코니아를 이용한 3-unit 브릿지 코어의 적합도를 "Replica Technique"으로 측정하여 기존 제품들의 내면 및 변연 적합도를 평가해 각 시스템의 적합 특성을 알아보고 임상 적용에 참고 자료로 활용하고자 시행하였다. 연구 재료 및 방법: 상악 좌측 제1소구치를 결손치로 하고 상악 좌측 견치, 상악 좌측 제2소구치를 지대치로 하는 3-unit 고정성 가공의치를 구현한 티타늄 모형을 제작하고, 40개의 실험 모형을 제작하였다. 각 모형을 10개씩 분류하고 Cerasys$^{(R)}$ (C군), Dentaim$^{(R)}$ (D군), KaVo Everest$^{(R)}$ (K군), $Lava^{TM}$ (L군)시스템으로 각각 지르코니아 코어를 제작하였다. 제작된 코어는 각 지대치마다 내면에 16개의 점을 선택하고 "Replica Technique"을 이용하여 각 포인트의 간극을 측정하였고 부위별 측정치를 비교, 평가하였다. Two-way ANOVA와 Dunnett T3 analysis를 이용하여 통계 분석하였다(${\alpha}$=.05). 결과: 모든 시스템에서 변연의 외부보다 내부에서 조금 더 큰 간극을 보이는 특징을 보였다. K군의 경우 전반적인 적합도는 우수하였으나 절단부위의 간극이 아주 크게 나타나는 특징을 보였고, C군의 경우 변연부위의 간극은 K군와 비교하여 크지만(P<.05) 전반적인 내면 간극이 다른 시스템에 비해 균일한 특징을 보였다. 축벽의 간극에서는 모든 시스템, 모든 절단부위에서 $100\;{\mu}m$ 미만의 우수한 적합도를 보였다. L군와 C군의 경우 변연의 외측부와 내측부의 간극차이가 적었으나 KaVo Everest$^{(R)}$와 Dentaim$^{(R)}$의 경우 마진 내측이 외측보다 간극이 큰 특징을 보였다(P<.05). 변연과 내면적합도로 나누어 분석하였을 때 K군과 C군이 D군과 L군보다 상대적으로 더 좋은 변연 및 내면 적합도를 보였고(P<.05) 두 지대치 중 견치가 제2소구치보다 더 좋은 적합도를 보였다(P<.05). 결론: 대부분의 시스템에서 변연 부위의 적합도는 임상적으로 허용 가능한 범위에 있었다. 변연 간극과 내면 간극 모두에서 지대치 중에 견치에서보다 제2소구치에서 더 큰 간극을 나타내었다. 또한 대부분의 시스템에서 축벽보다는 교합면 쪽 간극이 상대적으로 크게 형성되었다.

Evolutionary Model of Depression as an Adaptation for Blocked Social Mobility

  • Park, Hanson;Pak, Sunyoung
    • 생물정신의학
    • /
    • 제29권1호
    • /
    • pp.1-8
    • /
    • 2022
  • Objectives In regard to the social competition hypothesis, depression is viewed as an involuntary defeat strategy. A previous study has demonstrated that adaptation in microenvironments can result in a wide range of behavioural patterns including defense activation disorders. Using a simulation model with evolutionary ecological agents, we explore how the fitness of various defence activation traits has changed over time in different environments with high and low social mobility. Methods The Evolutionary Ecological Model of Defence Activation Disorder, which is based on the Marginal Value Theorem, was used to examine changes in relative fitness for individuals with defensive activation disorders after adjusting for social mobility. Results Our study examined the effects of social mobility on fitness by varying the d-values, a measure of depression in the model. With a decline in social mobility, the level of fitness of individuals with high levels of defense activation decreased. We gained insight into the evolutionary influence of varying levels of social mobility on individuals' degrees of depression. In the context of a highly stratified society, the results support a mismatch hypothesis which states that high levels of defence are detrimental. Conclusions Despite the fact that niche specialization in habitats composed of multiple microenvironments can result in diverse levels of defensive activation being evolutionary strategies for stability, decreased social mobility may lead to a decrease in fitness of individuals with highly activated defence modules. There may be a reason behind the epidemic of depression in modern society.

Replica technique과 Triple-scan protocol을 이용한 지르코니아 전부도재관의 변연 및 내면 적합도에 관한 비교 연구 (Marginal and internal fit of all ceramic crown using the replica technique and the triple-scan protocol)

  • 신미선;이장훈
    • 대한치과보철학회지
    • /
    • 제55권4호
    • /
    • pp.372-380
    • /
    • 2017
  • 목적: 본 연구는 보철물의 적합도를 계측하는 두 가지의 측정방법을 평가하기 위해 지르코니아로 전부도재관을 제작하고 replica technique과 triple-scan protocol을 이용하여 전부도재관의 변연 및 내면 적합도를 비교 연구하고자 하였다. 재료 및 방법: 타이타늄의 지대치 모형을 제작하여 20개의 지르코니아 전부도재관을 제작하였다. 제작된 지르코니아 전부도재관 10개는 replica technique을 이용해 복제하고 복제된 시편을 협설, 근원심으로 절단하여 변연 및 내면 적합도를 측정하였고, 다른 10개의 전부도재관은 triple-scan protocol을 이용하여 협설과 근원심으로 단면을 형성하고 변연 및 내면 적합도를 계측하여 통계 분석하였다 (${\alpha}=.05$). 결과: 변연과 내면 적합도는 replica technique $49.86{\pm}29.69{\mu}m$, triple-scan protocol $75.35{\pm}64.73{\mu}m$로 유의한 차이가 있었고 (P < .001), 내면 적합도만을 측정한 결과 각각 $58.38{\pm}31.77{\mu}m$, $64.00{\pm}46.43{\mu}m$로 유의한 차이가 없었다 (P > .343). 결론: Replica technique과 triple-scan protocol을 이용하여 전부도재관의 변연 및 내면 적합도를 비교 측정한 결과 triple-scan protocol에서의 변연 적합도가 크게 측정되었고, 내면 적합도만 비교해 본 결과 통계적인 유의한 차이가 없었다.

수 종의 지각 과민 완화제가 인산 아연 시멘트 사용시 주조관의 유지력 및 적합도에 미치는 영향 (THE EFFECT OF VARIOUS DESENSITIZING AGENTS ON RETENTION AND FITNESS OF CEMENTED CROWNS WITH ZINC PHOSPHATE CEMENT)

  • 오세욱;이호용
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.181-194
    • /
    • 1994
  • The purpose of this study was to compare the retention and fitness of crown treated with various desensitizing agents on natural teeth. Varnish, dentin primer, bonding agent and potassium oxalate treated groups and control group with no treatment were used. The retention test was executed with the Instron test machine(Instron Co.,U.S.A.) on 24 hours after cementation with zinc phosphate cement. After retention test, the teeth and crowns were washed and recemented. The cemented crowns were embedded in clear resin and sectioned with a diamond saw. The occlusal and marginal fitnesses, were measured indirectly with a stereomicroscopic photographs. The result of this study were obtained as follows : 1. The retention of control group was higher than any other desensitizing agent treated group. 2. The differences of retention among varnish, dentin primer, bonding agent and potassium oxalate treated groups were not statistically significant. 3. There were no statistically significant difference in fitness at occlusal surface and margin among control, varnish, dentin primer, bonding agent and potassium oxalate treated groups. According to these results, desensitizing agents used to protect the pulp from irritation of luting agents may adversely affect the retention of castings. Therefore, desensitizing agents should be used in limited areas carefully.

  • PDF

구강인기법과 왁스블록의 종류에 따른 금속 코핑의 변연적합도 비교 (Comparison of marginal fit of metal copings according to wax blocks and oral scanning methods)

  • 정인성;김원영;전병욱
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.234-239
    • /
    • 2020
  • Purpose: We investigated the marginal fit between abutment and metal copings according to impression technique, wax block types, and metal types. Methods: We selected the traditional impression method of using rubber impression materials and the digital impression method of using oral scanners, three types of wax blocks, and two types of metal, both of which were domestically and commercially available, were selected to produce metal copings, and the marginal fit was determined through the use of silicon replication. Results: The measurements of axial wall fit revealed that the IYV specimens had the best fit, with a mean gap of 24.11±5.95 ㎛, followed by CEV, CHV, CSS, CSV, CES, CHS, and IYS specimens (mean: 33.44±8.41 ㎛). The differences were not statistically significant. The marginal gap measurements showed that the CEV specimen had the smallest gap, 17.25±4.13 ㎛, followed by the CSV, CHV, CSS, CES, CHS, IYV, and IYS specimen (mean: 43.47±15.63 ㎛). The differences were statistically significant. Conclusion: The axial wall fit of the metal coping (VeraBond2V; Aalba Dent, Inc., Fairfield, CA, USA) produced by the lost wax technique with the traditional impression method was excellent. The marginal fit of the metal coping (VeraBond 2V) produced by wax milling with the use of an oral scanner was also excellent. The marginal fit of the metal coping was within the clinically acceptable limits in all groups.

A new manufacturing method of all ceramic restoration using alumina tape and presentation of clinical cases

  • Oh, Nam-Sik;Kim, Eui-Seong;Lee, Keun-Woo;Han, Jung-Suk;Kim, Dae-Joon;Lee, Myung-Hyun
    • 대한치과보철학회지
    • /
    • 제38권6호
    • /
    • pp.800-805
    • /
    • 2000
  • In an effort to facilitate fabrication procedure of all ceramic crowns, a novel preparation method for all ceramic crown using alumina tape was developed. The alumina tape having a uniform thickness was cast by using Doctor blade method. The physical properties of newly introduced alumina tape has biaxial flexure strength of $500\sim600MPa$. The value of toughness is $3.18\sim3,28MPa.m^{1/2}$ which corelates with fracture and the linear shrinkage rate of the alumina tape is 0.44% during core production. The marginal fitness of the alumina tape all-ceramic restoration with $90{!`}$shoulder margin had average marginal discrepancy at $78.3{\S}$ > and average marginal gap at $44.4{\S}$ >. At the marginal preparation of $135{!`}$deep chamfer, the average marginal discrepancy at $82.1{\S}$ > and the average marginal gap at $40.2{\S}$ > had been reported. This fabrication procedure of all ceramic crowns with alumina tapes is easier and less technical sensitive for dental technicians. After restoration with new all ceramic crowns we followed the patients 2 years later, there were no complications as porcelain fractures or periodontal disease. We had good esthetic clinical results with new all ceramic crowns.

  • PDF