• 제목/요약/키워드: Marginal Fitness

검색결과 56건 처리시간 0.031초

Comparison of fit and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems

  • Eun-Bin Bae;Won-Tak Cho;Do-Hyun Park;Su-Hyun Hwang;So-Hyoun Lee;Mi-Jung Yun;Chang-Mo Jeong;Jung-Bo Huh
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권3호
    • /
    • pp.155-170
    • /
    • 2023
  • PURPOSE. This study aims to clinically compare the fitness and trueness of zirconia crowns fabricated by different combinations of open CAD-CAM systems. MATERIALS AND METHODS. Total of 40 patients were enrolled in this study, and 9 different zirconia crowns were prepared per patient. Each crown was made through the cross-application of 3 different design software (EZIS VR, 3Shape Dental System, Exocad) with 3 different processing devices (Aegis HM, Trione Z, Motion 2). The marginal gap, absolute marginal discrepancy, internal gap(axial, line angle, occlusal) by a silicone replica technique were measured to compare the fit of the crown. The scanned inner and outer surfaces of the crowns were compared to CAD data using 3D metrology software to evaluate trueness. RESULTS. There were significant differences in the marginal gap, absolute marginal discrepancy, axial and line angle internal gap among the groups (P < .05) in the comparison of fit. There was no statistically significant difference among the groups in terms of occlusal internal gap. The trueness ranged from 36.19 to 43.78 ㎛ but there was no statistically significant difference within the groups (P > .05). CONCLUSION. All 9 groups showed clinically acceptable level of marginal gaps ranging from 74.26 to 112.20 ㎛ in terms of fit comparison. In the comparison of trueness, no significant difference within each group was spotted. Within the limitation of this study, open CAD-CAM systems used in this study can be assembled properly to fabricate zirconia crown.

Multivariate design estimations under copulas constructions. Stage-1: Parametrical density constructions for defining flood marginals for the Kelantan River basin, Malaysia

  • Latif, Shahid;Mustafa, Firuza
    • Ocean Systems Engineering
    • /
    • 제9권3호
    • /
    • pp.287-328
    • /
    • 2019
  • Comprehensive understanding of the flood risk assessments via frequency analysis often demands multivariate designs under the different notations of return periods. Flood is a tri-variate random consequence, which often pointing the unreliability of univariate return period and demands for the joint dependency construction by accounting its multiple intercorrelated flood vectors i.e., flood peak, volume & durations. Selecting the most parsimonious probability functions for demonstrating univariate flood marginals distributions is often a mandatory pre-processing desire before the establishment of joint dependency. Especially under copulas methodology, which often allows the practitioner to model univariate marginals separately from their joint constructions. Parametric density approximations often hypothesized that the random samples must follow some specific or predefine probability density functions, which usually defines different estimates especially in the tail of distributions. Concentrations of the upper tail often seem interesting during flood modelling also, no evidence exhibited in favours of any fixed distributions, which often characterized through the trial and error procedure based on goodness-of-fit measures. On another side, model performance evaluations and selections of best-fitted distributions often demand precise investigations via comparing the relative sample reproducing capabilities otherwise, inconsistencies might reveal uncertainty. Also, the strength & weakness of different fitness statistics usually vary and having different extent during demonstrating gaps and dispensary among fitted distributions. In this literature, selections efforts of marginal distributions of flood variables are incorporated by employing an interactive set of parametric functions for event-based (or Block annual maxima) samples over the 50-years continuously-distributed streamflow characteristics for the Kelantan River basin at Gulliemard Bridge, Malaysia. Model fitness criteria are examined based on the degree of agreements between cumulative empirical and theoretical probabilities. Both the analytical as well as graphically visual inspections are undertaken to strengthen much decisive evidence in favour of best-fitted probability density.

치과용 캐드캠을 이용하여 연질금속 재료로 제작한 고정성 보철물의 변연 간격 평가 (Evaluation of Marginal Gap of Fixed Dental Prostheses Fabricated by Soft Metal Material Using Dental CAD/CAM)

  • 김재홍;김원수;김기백
    • 치위생과학회지
    • /
    • 제14권3호
    • /
    • pp.349-355
    • /
    • 2014
  • 본 연구는 최근 치의학계 전반적으로 치과용 캐드캠 시스템의 사용이 증가함에 따라 새로운 재료의 개발도 활발히 이루어지고 있는 현실을 반영하였다. 최근 새롭게 개발된 고정성 보철물의 제작 재료인 연질금속재료를 이용하여 제작된 고정성 보철물의 변연 간격을 평가하여 봄으로써 신재료의 임상적 허용 가능성을 변연 간격을 기준으로 가늠하여보고자 하였으며, 나아가서는 치과의사, 치과위생사 및 치과기공사 등 해당 분야 임상가들에게 참고자료를 제시하고자 하였다. 연구 결과에 따르면 연질금속블록을 가공하여 제작된 집단이 전통적인 방식에 의해 제작된 집단보다 우수한 변연간격을 보였으나, 통계적으로 유의하지 않았다. 또한 연질금속블록을 가공하여 제작된 보철물들의 변연 간격이 임상적 허용 수치로 제시되고 있는 $120{\mu}m$를 넘지 않는 것으로 보아 변연 간격을 기준으로 하였을 때 임상적으로 허용이 가능할 것으로 생각된다.

지대치 변연 형태에 따른 수작업과 CAD/CAM으로 제작한 coping 패턴의 적합도 비교 (Comparison of the fit of the coping pattern constructed by manual and CAD/CAM, depending on the margin of the abutment tooth)

  • 한민수;권은자;최에스더;김시철
    • 한국산학기술학회논문지
    • /
    • 제16권10호
    • /
    • pp.6611-6617
    • /
    • 2015
  • 본 연구는 수작업으로 제작된 metal coping과 CAD/CAM(Computer Aided Design/Computer Aided Manufacturing)으로 제작된 지르코니아 coping을 제작하여 변연과 내면 적합도를 비교 분석하고자 하였다. 모형은 우레탄 모형재를 사용하여 knife, chamfer변연 두 종류의 지대치를 제작하였다. 수작업과 CAD/CAM으로 제작된 보철물의 변연 적합도를 실리콘 리플리카 테크닉방법을 사용하여 측정하였다. 적합도 측정은 현미경의 CCD카메라로 캡쳐하였다. 이때 지대치와 보철물의 거리는 이미지분석 소프트웨어에서 거리 조정이 된 상태에서 실시하였다. 측정부위는 marginal opening을 MO, marginal gap을 MG, internal gap을 IG, Axial gap을 AG, occlusal gap을 OG로 하였다. 제작법과 변연 형태에 따른 비교분석을 위해 이원배치분산분석을 실시하였으며 서로 다른 평균값들의 비교 분석을 위해서 일원배치분산분석과 Scheffe's 사후 검정을 실시하였다. 그 결과 CAD/CAM의 OG와 knife 변연의 MO을 제외하고는 < $120{\mu}m$ 적합도를 나타냈다. CAD/CAM으로 제작된 coping은 chamfer 변연 MO에서 높은 적합도를 보였으나 MG에서는 knife변연이 chamfer변연 보다 더 좋은 적합도를 보였다. AG의 내면 적합도는 가장 좋은 값을 나타내었다(< $38{\mu}m$).

주입선의 설계가 임플란트 보철물의 적합도에 미치는 영향 (Effect of the Sprue Design on the Fitness of Implant Prosthesis)

  • 황성택;안재석;신상완
    • 대한치과기공학회지
    • /
    • 제30권2호
    • /
    • pp.57-63
    • /
    • 2008
  • Statement of problem: Conventional techniques for implant framework fabrication produce significant error that is inconsistent with passive-fit requirement for osseointegrated implants. One of the etiologic factors which cause the errors is a sprue which may deform the framework during solidification and contraction. Purpose: This study was aimed to evaluate objectively effect of the sprue design on the accuracy of fit of implant prosthesis. Materials and method: Three different designs were considered relative to effect of casting accuracy. The first design had straight sprues and a button of excess alloy at the non-casting end of the sprues. The second was runner bar design(with the button). The last was straight sprues design(without the button). Gold cylinder and laboratory analogue had been used to diminish variables affecting to casting accuracy. Gold alloy and pressure-vacuum casting machine had been used. Marginal gap had been measured by SEM. One-way ANOVA and Duncan test had been used for statistical analysis. Results: The first design showed $79.87{\pm}13.95{\mu}m$ marginal gap. The second and third were $40.17{\pm}15.8{\mu}m$ and $35.17{\pm}9.95{\mu}m$ respectively. Conclusion: Straight sprues without button and runner bar designs were more accurate than straight sprues with button design(P<.05).

  • PDF

전기성형법을 이용한 치과용 금속-도재관의 소성에 따른 물성 변화가 변연 간격에 미치는 영향 (Effects of Property Transformation and Marginal Gap Depending on Heat-Treatment of Metal-Porcelain by Gold Electro-Forming System)

  • 김치영;정인성;최성민
    • 한국콘텐츠학회논문지
    • /
    • 제10권6호
    • /
    • pp.352-359
    • /
    • 2010
  • 본 연구에서는 전기성형법을 이용한 금속-도재관의치의 도재소성에 따른 물성변화와 변연간격을 측정하여 변연 적합도에 미치는 영향을 고찰하여 정밀성을 평가하고자 한다. 물성변화와 변연간격을 관찰하기 위하여 물성 관찰시편은 소성 횟수를 고려하여 소성을 0회(HC), 1회(H1), 2회(H2), 3회(H3) 실시한 군으로 분류하였으며, 변연간격 관찰시편은 전용결합재 처리 군(FS), 전용결합재와 opaque 처리 군(FO), 전용 결합재와 opaque와 bady를 처리한 군(FB) 그리고 소성이 없는 군(FC)으로 분류하였다. 물성 관찰시편의 미소경도 관찰결과 대조군(HC)에 비하여 시험군(H1, H2, H3)의 경도가 감소하는 것을 관찰 할 수 있었다(p<0.05). 그리고 변연간격 관찰결과 GES 금속-도재관의 제작과정 중 발생하는 도재의 소성 횟수가 변연부에는 영향을 주지 않는 것을 관찰할 수 있었다(p>0.05).본 연구를 종합하여 분석한 결과 소성과정에서 열에 의한 연화열처리 효과로 경도감소가 발생하지만 변연간격에는 영향을 미치지 않은 결과를 얻어 GES 금속-도재관의 제작과정에서 도재소성으로 인한 변연 적합도 변화는 없으며 정밀도에도 영향을 미치지 않는 것으로 판단된다.

$Procera^{(R)}$ AllCeram 을 이용한 도재관의 임상적 변연적합도에 관한 연구 (The marginal fidelity of $Procera^{(R)}$ AllCeram alumina copings and crowns of patients)

  • 송영균;조인호;이종혁
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.470-478
    • /
    • 2008
  • 완전도재 수복물은 뛰어난 심미성을 가지고 있어, 환자들의 심미적 욕구를 충족시킬 수 있다. 이러한 도재관을 제작함에 있어 CAD/CAM 시스템을 이용하는 것은 시간과 비용을 절약할 수 있는 장점을 가지고 있으며, 정밀도 또한 점차 높아지고 있다. 특히 변연적합도는 수복물의 성공 여부에 중요한 요소이고, 이 분야에 대한 실험적 연구는 많이 보고되고 있으나 임상적인 연구는 아직 미흡한 실정이다. 본 연구에서는 CAD/CAM 시스템의 하나인 $Procera^{(R)}$ AllCeram 시스템의 변연적합도를 실제 환자의 수복물 상에서 측정함으로써 임상에 사용되는 CAD/CAM 시스템의 변연적합도를 연구하고자 하였다. 단국대학교 치과병원 보철과에 내원한 56명, 101개의 지대치에 대해 코핑 상태와 최종수복물의 변연오차를 입체광학현미경으로 측정하고 비교분석하여 다음과 같은 결과를 얻었다. 실험 결과, 코핑의 변연오차 ($53.84{\pm}38.83\;{\mu}m$)보다 최종 수복물에서의 변연오차 ($45.82{\pm}30.84\;{\mu}m$)가 더 낮은 값을 나타났으며, 이는 통계적으로 유의한 차이가 있었다 (P < .05). 각 측정 지점간 비교에서 역시 모든 변연에서 코핑 의 변연오차가 최종 수복물에서의 변연오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 구치부의 변연오차는 전치부의 변연오차보다 더 높은 값을 나타냈으나, 통계적으로 유의한 차이는 없었다. 설측 변연의 경우, 근심, 원심, 순측 변연의 오차보다 더 높은 값을 나타냈으며, 통계적으로 유의한 차이가 있었다 (P < .05). 이상의 결과로 보아 $Procera^{(R)}$ 시스템의 Allceram 관의 변연적합도는 임상적 허용 범위 내에 있었으며, 특히 도재 축성후 변연적합도 는 더 우수해지는 것으로 나타났으며, 각 변연 중 설측 변연의 오차가 가장 큰 것은 주모형의 정보 입력시 순측 부위의 특성상 일어나는 오류로 사료된다. $Procera^{(R)}$ 시스템 Allceram 관 수복시 설측 변연에 더욱 주의를 기울이는 것이 좋은 변연적합을 얻는 데 도움이 될 것으로 사료되며, 앞으로 주모형 변연 부위의 변곡 정도에 따른 변연오차에 대한 연구가 필요할 것으로 사료된다.

치과 캐드/캠 시스템으로 제작된 지르코니아 single 코핑과 3-unit 구조물의 상대적 적합도 비교 (Comparison of relative fitness between zirconia single coping and 3-unit fixed partial dentures (FPDs) manufactured by dental CAD/CAM system)

  • 이완선;박종경;김욱태
    • 구강회복응용과학지
    • /
    • 제30권1호
    • /
    • pp.16-22
    • /
    • 2014
  • 목적: 본 연구의 목적은 동일한 모형에서 제작된 지르코니아 single 코핑과 3-unit 구조물의 변연 및 내면 적합도를 평가하는 것이다. 연구 재료 및 방법: 상악 우측 제2소구치가 상실되고 상악 제1소구치와 제2대구치가 지대치로 형성된 에폭시 모형(epoxy model)을 제작한 후 레이저 스캐너를 이용하여 스캔 하였다. CAD 소프트웨어를 이용하여 지르코니아 구조물을 디자인하고 CAM을 사용하여 지르코니아 single 코핑과 3-unit 구조물을 제작 하였다. 지르코니아 single 코핑은 상악 제1소구치, 제2대구치에서 각각 10개씩 제작 되었고 지르코니아 3-unit 구조물도 10개가 제작 되었다. 적합도 측정을 위하여 제작된 실리콘 복제(silicone replica)를 4등분하고 각 면의 측정 위치(P1, P2, P3, P4, P5)에서 디지털 현미경을 사용하여 적합도를 측정하였다. 각 위치에서 측정된 불일치 값들은 변연 불일치(MG, P1), 축 불일치(AG, P2와 P3의 평균), 교합 불일치(OG, P4와 P5의 평균)의 세 범주로 분류하였다. 결과: Single 코핑에서 변연 불일치의 범위는 18.47 - 40.54 ${\mu}m$, 축 불일치의 범위는 39.73 - 73.61 ${\mu}m$, 교합 불일치의 범위는 116.90 - 134.69 ${\mu}m$이었다. 3-unit 구조물에서 변연 불일치의 범위는 45.95 - 87.44 ${\mu}m$이고, 축 불일치의 범위는 23.78 - 57.00 ${\mu}m$이고, 교합 불일치는 99.89 - 131.06 ${\mu}m$이었다. 결론: 본 연구의 결과에 따르면 single 코핑에 비해 3-unit 구조물의 변연 불일치가 증가하였지만 임상학적 수용 범위(- 120 ${\mu}m$) 내에 있었으며 3-unit 구조물의 불일치 증가를 방지하기 위해서 더욱 균질한 지르코니아 블록 사용과 소결공정들을 조절해야 할 것이다.

마이크로 웨이브 소결 과정이 CAD/CAM 지르코니아 코아의 적합도에 미치는 영향 (The Influence of Microwave Sintering Process on the Adaptation of CAD/CAM Zirconia Core)

  • 김근배;김지환;이근우
    • 구강회복응용과학지
    • /
    • 제25권2호
    • /
    • pp.95-107
    • /
    • 2009
  • 본 연구의 목적은 전통적인 소결 방법과 마이크로 웨이브 소결 방법에 의해 제작된 지르코니아 코아의 내부 및 변연 적합도를 알아보는 것이다. 본 실험은 기존의 소결로를 이용하는 $3M^{(R)}$의 Lava(LAV), $Kavo^{(R)}$사의 Everest(EVE), $Cerasys^{(R)}$ CAD/CAM 시스템(CER)과 마이크로웨이브 소결로를 이용하는 Dent. $solution^{(R)}$사의 CAD/CAM 시스템(DEN)에서 시스템별로 12개씩의 코아를 제작하고 실리콘 접착제를 이용하여 금속 다이에 부착시켰다. $Skyscan^{(R)}$ 1076 미세 단층 촬영기를 이용해 각각의 시편을 촬영한 후 재구성하였다. 각 시편에 대해 B-L상, M-D상 절단면 및 치아 장축에 대한 횡단면을 구해내고 각각의 단면에 대해 변연 간격, 축면 간격, 교합면 간격을 측정하였다. 실험에 대한 결과는 다음과 같다. 1. 변연 간격은 EVE가 $36.20{\mu}m$로 가장 작았고, LAV는 $47.67{\mu}m$, DEN는 $52.47{\mu}m$, CER은 $54.63{\mu}m$를 나타내었다. 2. 축면 간격은 EVE가 $63.49{\mu}m$로 가장 큰 값을 나타내었으나 네군간에는 유의차는 없었다. 3. 교합면 간격은 DEN이 $77.06{\mu}m$으로 가장 작은 값을 나타내었으며, EVE와 CER은 $100{\mu}m$를 넘는 값으로 다른 두군과 유의차를 보였다. 본 연구에서 마이크로웨이브 소결을 통해 제작된 CAD/CAM 지르코니아 코아는 임상적으로 허용할 만한 변연 간격 및 축면 간격, 교합면 간격을 보여 주었다.

단일 도재 수복물의 가공 정밀도가 변연 및 내면 적합도에 미치는 영향 (Effect of machining precision of single ceramic restorations on the marginal and internal fit)

  • 손큰바다;유범영;이규복
    • 대한치과보철학회지
    • /
    • 제58권4호
    • /
    • pp.313-320
    • /
    • 2020
  • 목적: 본 연구의 목적은 3 종류의 치과용 도재 블록으로 제작된 단일 수복물의 가공 정밀도와 변연 및 내면 적합도를 평가하고, 상관관계를 분석하는 것이다. 재료 및 방법: 3 종류의 치과용 도재 블록(Rosetta; HASS, IPS e.max CAD; Ivoclar vivadent, VITA Suprinity; VITA)으로 제작된 단일 수복물의 가공 정밀도와 변연 및 내면 적합도를 평가하였다. 캐드 소프트웨어에서 단일 수복물을 디자인하였고, 수복물 디자인 모델(crown designed model) 파일의 제작을 위해 디자인 후 캐드 소프트웨어에서 추출하였다. 그리고 수복물 디자인 모델 파일은 밀링 장비를 사용하여 도재 블록(lithium disilicate ceramic block)을 가공하였다. 수복물 스캔 모델(crown scanned model) 파일의 제작을 위해서 접촉식 스캐너를 이용하여 제작된 수복물의 내면을 디지털화 하였다. 그리고 삼차원 검사 소프트웨어(Geomagic control X; 3D Systems)를 이용하여, 수복물 디자인 모델과 스캔 모델의 중첩과 가공 정밀도의 삼차원 분석의 단계로 진행되었다. 그리고 제작된 수복물의 변연 및 내면 적합도는 실리콘 복제 방법으로 평가되었다. 3 종류의 단일 도재 수복물의 차이는 Kruskal-Wallis H test를 통해 분석되었고, 가공 정밀도와 변연 및 내면 적합도의 상관관계를 분석하기 위해서 Spearman correlation analysis을 하였다 (α = .05). 결과: 도재 블록의 종류에 따라서 가공 정밀도와 변연 및 내면 적합도는 유의미한 차이가 있었다 (P < .001). 그리고 가공 정밀도와 변연 및 내면 적합도는 서로 양의 상관관계를 보였다 (P < .001). 결론: 도재 블록의 종류에 따라서 제작된 단일 수복물의 변연 적합도는 임상적 허용 범위에 있었기 때문에(< 120 ㎛), 적합도 측면에서 모두 임상에 적용할 수 있는 적절한 가공 정밀도로 간주할 수 있다.