참고문헌
- Kim KB, Kim WC, Kim HY, Kim JH: An evaluation of marginal fit of three-unit fixed dental prostheses fabricated by direct metal laser sintering system. Dent Mater 29: e91-e96, 2013.
- Han MS, Kim KB: Comparison of the marginal and internal fit on the cast and CAD-CAM cores. J Dent Hyg Sci 12: 368-374, 2012.
- Kim JH, Kim KB: Influence of high temperature of the porcelain firing process on the marginal fit of zirconia core. J Dent Hyg Sci 13: 135-141, 2013.
- Foster LV: Failed conventional bridge work from general dental practice: clinical aspects and treatment needs of 142 cases. Br Dent J 168: 199-201, 1990. https://doi.org/10.1038/sj.bdj.4807133
- Kim KB, Kim JH, Kim WC, Kim HY, Kim JH: Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: twoand three- dimensional replica techniques. J Adv Prosthodont 5: 179-186, 2013. https://doi.org/10.4047/jap.2013.5.2.179
- Ucar Y, Akova T, Akyil MS, Brantley WA: Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns. J Prosthet Dent 102: 253-259, 2009. https://doi.org/10.1016/S0022-3913(09)60165-7
- Örtorp A, Jönsson D, Mouhsen A, Vult von Steyern P: The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. Dent Mater 27: 356-363, 2011. https://doi.org/10.1016/j.dental.2010.11.015
- Quante K, Ludwig K, Kern M: Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology. Dent Mater 24: 1311-1315, 2008. https://doi.org/10.1016/j.dental.2008.02.011
- Kokubo Y, Tsumita M, Kano T, Sakurai S, Fukushima S: Clinical marginal and internal gaps of zirconia all-ceramic crowns. J Prosthodont Res 55: 40-43, 2011. https://doi.org/10.1016/j.jpor.2010.09.001
- Holmes JR, Bayne SC, Holland GA, Sulik WD: Considerations in measurement of marginal fit. J Prosthet Dent 62: 405-408, 1989. https://doi.org/10.1016/0022-3913(89)90170-4
- Kim JH, Kim KB: An evaluation validity of the silicone replica technique at measurement on fit of fixed dental prostheses. J Dent Hyg Sci 12: 566-571, 2012.
- McLean JW, von Fraunhofer JA: The estimation of cement film thickness by an in vivo technique. Br Dent J 131: 107- 111, 1971. https://doi.org/10.1038/sj.bdj.4802708
- Blackman R, Baez R, Barghi N: Marginal accuracy and geometry of cast titanium copings. J Prosthet Dent 67: 435- 440, 1992. https://doi.org/10.1016/0022-3913(92)90068-L
- Gavelis JR, Morency JD, Riley ED, Sozio RB: The effect of various finish line preparations on the marginal seal and occlusal seat of full crown preparations. J Prosthet Dent 92: 1-7, 2004. https://doi.org/10.1016/j.prosdent.2004.03.024
- Oruc S, Tulunoglu Y: Fit of titanium and a base metal alloy metal-ceramic crown. J Prosthet Dent 83: 314-318, 2000. https://doi.org/10.1016/S0022-3913(00)70134-X
- Beuer F, Aggstaller H, Edelhoff D, Gernet W, Sorensen J: Marginal and internal fits of fixed dental prostheses zirconia retainers. Dent Mater 25: 94-102, 2009. https://doi.org/10.1016/j.dental.2008.04.018
- Witkowski S, Komine F, Gerds T: Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques. J Prosthet Dent 96: 47-52, 2006. https://doi.org/10.1016/j.prosdent.2006.05.013
- Tan PL, Gratton DG, Diaz-Arnold AM, Holmes DC: An in vitro comparison of vertical marginal gaps of CAD/CAM titanium and conventional cast restorations. J Prosthodont 17: 378-383, 2008. https://doi.org/10.1111/j.1532-849X.2008.00302.x
피인용 문헌
- 3차원 프린팅 기술에 의해 제작된 3본 금속 코어의 변연 간격 평가 vol.15, pp.2, 2014, https://doi.org/10.17135/jdhs.2015.15.2.196
- 총의치 제작을 위한 무치악 디지털 모형의 정확도 평가 vol.15, pp.4, 2015, https://doi.org/10.17135/jdhs.2015.15.4.393
- 분말야금공법으로 제조된 CAD/CAM용 Co-Cr-Mo 합금의 미세조직 및 기계적 특성 vol.37, pp.4, 2014, https://doi.org/10.14347/kadt.2015.37.4.235
- 치과용 Co-Cr sinter metal의 소결 후 변형비교 vol.38, pp.3, 2014, https://doi.org/10.14347/kadt.2016.38.3.127
- 치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가 vol.38, pp.3, 2014, https://doi.org/10.14347/kadt.2016.38.3.185