• Title/Summary/Keyword: Map Coverage

Search Result 137, Processing Time 0.026 seconds

Analysis of the Emergency Medical Service Area Using GIS: the Case of Seoul (GIS를 이용한 응급의료 진료권 분석: 서울시를 사례로 하여)

  • 이희연;박미영
    • Spatial Information Research
    • /
    • v.12 no.2
    • /
    • pp.193-209
    • /
    • 2004
  • The purpose of this study is to analyze the service area of emergency medical centers using GIS-based spatial analysis methods in Seoul, focusing on the behaviour of patients on the choosing of emergency centers. For this analysis, six emergency centers were selected to collect data for the information on the addresses of patients from September to November hi 2003. Analysis on the service area, which was carried out by measuring the distribution of patients in terms of distance from emergency medical centers, clearly reveals that the majority of patients was located within or adjacent districts at the emergency medical center. However, the size of the primary service area f3r six emergency medical centers was much different, implying that the decision to visit specific emergency medical center by patients was closely related to the size, perception, and preference of the emergency medical center. Based on the results of the spatial characteristics of emergency medical service area, this research tries to construct the surface map of the emergency medical service level supplied by 32 regional emergency medical centers located in Seoul. Considering the levels of infrastructure for emergency medical centers, the coverage for the degree of supply of emergency medical service by each emergency medical center was constructed in terms of a distance decaying in the distribution of patients from emergency medical center imposing different weights on distance bands. Spatial overlay utilizing map algebra function was performed in order to calculate total supply level of emergency service. The results clearly show that spatial inequality exists in the supply levels of the emergency medical service among local areas of Seoul.

  • PDF

Review of Remote Sensing Technology for Forest Canopy Height Estimation and Suggestions for the Advancement of Korea's Nationwide Canopy Height Map (원격탐사기반 임분고 추정 모델 개발 국내외 현황 고찰 및 제언)

  • Lee, Boknam;Jung, Geonhwi;Ryu, Jiyeon;Kwon, Gyeongwon;Yim, Jong Su;Park, Joowon
    • Journal of Korean Society of Forest Science
    • /
    • v.111 no.3
    • /
    • pp.435-449
    • /
    • 2022
  • Forest canopy height is an indispensable vertical structure parameter that can be used for understanding forest biomass and carbon storage as well as for managing a sustainable forest ecosystem. Plot-based field surveys, such as the national forest inventory, have been conducted to provide estimates of the forest canopy height. However, the comprehensive nationwide field monitoring of forest canopy height has been limited by its cost, lack of spatial coverage, and the inaccessibility of some forested areas. These issues can be addressed by remote sensing technology, which has gained popularity as a means to obtain detailed 2- and 3-dimensional measurements of the structure of the canopy at multiple scales. Here, we reviewed both international and domestic studies that have used remote sensing technology approaches to estimate the forest canopy height. We categorized and examined previous approaches as: 1) LiDAR approach, 2) Stereo or SAR image-based point clouds approach, and 3) combination approach of remote sensing data. We also reviewed upscaling approaches of utilizing remote sensing data to generate a continuous map of canopy height across large areas. Finally, we provided suggestions for further advancement of the Korean forest canopy height estimation system through the use of various remote sensing technologies.

Comparative Evaluation of Impervious Ratio between KNU and HKU Campus Using Google Earth (Google Earth를 이용한 경북대와 홍콩대 캠퍼스의 불투수율 비교평가)

  • Um, Jung-Sup
    • Journal of the Korean association of regional geographers
    • /
    • v.15 no.3
    • /
    • pp.421-433
    • /
    • 2009
  • The impervious ratio was frequently employed as a fundamental attribute will be used as a proxy of the total environmental burden in the urban area since it may contribute as much or more on a cumulative basis to the overall environmental condition. This research proposes a comparative evaluation framework in a more objective and Quantitative way for an impervious ratio in the university campus, using the Google Earth. Two university campuses (Kyungpook National University: KNU, Hong Kong University: HKUJ were selected as survey objectives in order to evaluate the potential of Google Earth in monitoring impervious conditions in the campus. The 61cm resolution of Quickbird data combined with digital map realistically identified the major type of impervious surface such as road, building and parking lots in the study area by large scale spatial precision. The impervious zones with persistently high road density and parking space were specifically identified over the KNU campus while the HKC campus was intensively covered by tree, resulting in almost twice (31%). as compared to KNU (18.4%), The methods of characterizing impervious surface used in this study are easily replicable using data that are primarily publicly available, and therefore the collection of impervious coverage data via Google Earth is, therefore, proposed as a practical alternative.

  • PDF

Structure of Forest Community in Mt. Busosan, Buyeo-Gun (부여군 부소산의 산림군락 구조)

  • Cheong, Yongmoon;Kim, Dongseok;Kim, Kwangdong;Lee, Sanghwa;Song, Hokyung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.1
    • /
    • pp.55-63
    • /
    • 2006
  • This study was carried out to analyze community character and classify forest community with phytosociological method and quadrat method to forest of Mt. Busosan in Buyeo-Gun.1. Communities by phytosociological method were classified into Pinus densiflora community and Quercus sp. community. With the classification of TWINSPAN, the community was categorized into Pinus densiflora - Quercus variabilis community and Pinus densiflora - Styrax japonica community.2. The importance value of Pinus densiflora, Quercus acutissima, Prunus sargentii, Styrax japonica, Quercus serrata, Quercus variabilis, Pinus rigida, Quercus aliena in tree layer were 83.20, 41.87, 30.93, 24.85, 23.27, 20.97, 20.28, and 9.46, respectively. The relative coverage of Stephanandra incisa, Quercus serrata, Styrax japonica, Parthenocissua tricuspidata, Rhododendron mucronulatum, Lindera obtusiloba, Prunus sargentii, Quercus variabilis, Indigofera kirilowii, Quercus acutissima, Lespedeza maximowiczii, and Acer pseudosibolianum in shrub layer were 9.62%, 9.55%, 9.18%, 7.85%, 6.18%, 5.25%, 4.82%, 4.15%, 3.98%, 3.98%, 3.55%, and 2.98%, respectively.3. According to size distribution map of diameter breast height of dominant species, the dominant species of Mt. Busosan was Pinus densiflora, and Quercus sp. such as Quercus acutissima, Quercus variabilis, and Quercus serrata may compete with the Pinus densiflora in the future.4. According to the ordination analysis of Mt. Busosan forest, Pinus densiflora - Styrax japonica community was found in moist site and Pinus densiflora - Quercus variabilis community was found in dry site.

Efficient Estimation Method of Reception Rate for Terrestrial Digital TV Broadcasting Service (효율적인 지상파 디지털 TV방송 수신율 산정방안)

  • Kwon, Won-Hyun;Kim, Kwang-Ui
    • Journal of IKEEE
    • /
    • v.16 no.1
    • /
    • pp.7-14
    • /
    • 2012
  • In this paper, a reception rate of terrestrial digital TV broadcasting service is analyzed and a novel method which can estimate the broadcasting coverage rate more objectively and reliably than the existing method is proposed. Previous method measures the reception rate by means of electric field intensity measurement or subjective video quality assessment. Because of limited measuring points, it inherently has measurement error and cannot consider the viewer's receiving conditions in real-time. In order to consider the viewer's population and receiving environment, morphology which characterizes the viewer's receiving environment is extracted using household census data of National Statistical Office and the land cover map of Ministry of Environment. Using the extracted geographical morphology, the reception rate of terrestrial digital TV broadcasting service is calculated with Spectrum Management Intelligence System (SMIs). Proposed method can calculate the reception rate more objectively and reliably than the existing methods because it fully considers the viewer's receiving environments in real-time.

Development of Land Surface Temperature Retrieval Algorithm from the MTSAT-2 Data

  • Kim, Ji-Hyun;Suh, Myoung-Seok
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.6
    • /
    • pp.653-662
    • /
    • 2011
  • Land surface temperature (LST) is a one of the key variables of land surface which can be estimated from geostationary meteorological satellite. In this study, we have developed the three sets of LST retrieval algorithm from MTSAT-2 data through the radiative transfer simulations under various atmospheric profiles (TIGR data), satellite zenith angle, spectral emissivity, and surface lapse rate conditions using MODTRAN 4. The three LST algorithms are daytime, nighttime and total LST algorithms. The weighting method based on the solar zenith angle is developed for the consistent retrieval of LST at the early morning and evening time. The spectral emissivity of two thermal infrared channels is estimated by using vegetation coverage method with land cover map and 15-day normalized vegetation index data. In general, the three LST algorithms well estimated the LST without regard to the satellite zenith angle, water vapour amount, and surface lapse rate. However, the daytime LST algorithm shows a large bias especially for the warm LST (> 300 K) at day time conditions. The night LST algorithm shows a relatively large error for the LST (260 ~ 280K) at the night time conditions. The sensitivity analysis showed that the performance of weighting method is clearly improved regardless of the impacting conditions although the improvements of the weighted LST compared to the total LST are quite different according to the atmospheric and surface lapse rate conditions. The validation results of daytime (nighttime) LST with MODIS LST showed that the correlation coefficients, bias and RMSE are about 0.62~0.93 (0.44~0.83), -1.47~1.53 (-1.80~0.17), and 2.25~4.77 (2.15~4.27), respectively. However, the performance of daytime/nighttime LST algorithms is slightly degraded compared to that of the total LST algorithm.

Mapping the water table at the Cheongju-Gadeok site of the Korea National Groundwater Monitoring Network using multiple geophysical methods

  • Ju, Hyeon-Tae;Sa, Jin-Hyeon;Kim, Ji-Soo
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.305-312
    • /
    • 2017
  • The most effective way to distinguish subsurface interfaces that produce various geophysical responses is through the integration of multiple geophysical methods, with each method detecting both a complementary and unique set of distinct physical properties relating to the subsurface. In this study, shallow seismic reflection (SSR) and ground penetrating radar (GPR) surveys were conducted at the Cheongju-Gadeok site of the Korea National Groundwater Monitoring Network to map the water table, which was measured at 12 m depth during the geophysical surveys. The water table proved to be a good target reflector in both datasets, as the abrupt transition from the overlying unsaturated weathered rock to the underlying saturated weathered rock yielded large acoustic impedance and dielectric constant contrasts. The two datasets were depth converted and integrated into a single section, with the SSR and GPR surveys conducted to ensure subsurface imaging at approximately the same wavelength. The GPR data provided detailed information on the upper ~15 m of the section, whereas the SSR data imaged structures at depths of 10-45 m. The integrated section thus captured the full depth coverage of the sandy clay, water table, weathered rock, soft rock, and hard rock structures, which correlated well with local drillcore and water table observations. Incorporation of these two geophysical datasets yielded a synthetic section that resembled a simplified aquifer model, with the best-fitting seismic velocity, dielectric constant, and porosity of the saturated weathered layer being $v_{seismic}=1000m/s$, ${\varepsilon}_r=16$, and ${\phi}=0.32$, respectively.

Remote Navigation and Monitoring System for Mobile Robot Using Smart Phone (스마트 폰을 이용한 모바일로봇의 리모트 주행제어 시스템)

  • Park, Jong-Jin;Choi, Gyoo-Seok;Chun, Chang-Hee;Park, In-Ku;Kang, Jeong-Jin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.6
    • /
    • pp.207-214
    • /
    • 2011
  • In this paper, using Zigbee-based wireless sensor networks and Lego MindStorms NXT robot, a remote monitoring and navigation system for mobile robot has been developed. Mobile robot can estimate its position using encoder values of its motor, but due to the existing friction and shortage of motor power etc., error occurs. To fix this problem and obtain more accurate position of mobile robot, a ultrasound module on wireless sensor networks has been used in this paper. To overcome disadvantages of ultrasound which include straightforwardness and narrow detection coverage, we rotate moving node attached to mobile robot by $360^{\circ}$ to measure each distance from four fixed nodes. Then location of mobile robot is estimated by triangulation using measured distance values. In addition, images are sent via a network using a USB Web camera to smart phone. On smart phones we can see location of robot, and images around places where robot navigates. And remote monitoring and navigation is possible by just clicking points at the map on smart phones.

Spatial Prediction of Wind Speed Data (풍속 자료의 공간예측)

  • Jeong, Seung-Hwan;Park, Man-Sik;Kim, Kee-Whan
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.2
    • /
    • pp.345-356
    • /
    • 2010
  • In this paper, we introduce the linear regression model taking the parametric spatial association structure into account and employ it to five-year averaged wind speed data measured at 460 meteorological monitoring stations in South Korea. From the prediction map obtained by the model with spatial association parameters, we can see that inland area has smaller wind speed than coastal regions. When comparing the spatial linear regression model with classical one by using one-leave-out cross-validation, the former outperforms the latter in terms of similarity between the observations and the corresponding predictions and coverage rate of 95% prediction intervals.

Estimating Method of Topographic Factor of Design Wind Speed Using GIS (GIS를 이용한 지형에 의한 풍속할증계수 산정 방법)

  • Choi, Se-Hyu;Seo, Eun-Su
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.16 no.3
    • /
    • pp.126-135
    • /
    • 2013
  • With more than 70% of the country consisting of mountains, Korea has large and small mountains, and hills located in the inner cities. Therefore, Korea's architectural structure laws stipulate that an increase in wind speed due to the influence of terrain should be considered in the design of wind loads of buildings. But if more than two mountains are located around the building or if the boundaries of the land surface are not clear when calculating topographic factors of wind speed, the designer has subjectively selected the coverage of the topographic factors of wind speed or the surface. This may lead to unscientific design of wind loads. This study attempts to analyze topographic factors of wind speed by using a 1:5000 topographic map with relatively high location accuracy and thereby to reflect changes due to the topographic characteristics and influence at the point where the building is located. By also selecting terrain surfaces and vertexes through Arc GIS and presenting a scientific approach to determine the range of topographic factors of wind speed, this study is expected to make a contribution for more rational and cost-effective wind-resistant design of buildings.