• 제목/요약/키워드: Mandibular implant Overdenture

검색결과 73건 처리시간 0.022초

Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study

  • Bilhan, Selda Arat;Geckili, Onur;Cilingir, Altug;Bozdag, Ergun;Bilhan, Hakan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권4호
    • /
    • pp.199-206
    • /
    • 2019
  • Objectives: In mandibular edentulism, the treatment option with a two-interforaminal implant-retained bridge and a removable partial denture is rarely evaluated in literature. The aim of this in vitro study was to evaluate the stress distribution of this treatment option by comparing it with traditional treatment options with interforaminal implants in the edentulous mandible. Materials and Methods: Two interforaminal implants were placed in a formalin-fixed cadaver mandible, and overdentures with three different types of attachments were fabricated: (1) two ball attachments and an overdenture, (2) a Dolder bar and an overdenture, and (3) screw-retained two-implant inter-canine porcelain fused to a metal bridge and an implant-assisted removable denture (IARD) with precision attachments. Three biting conditions were generated for each denture type, and the strains were documented under vertical loading of 100 N. Results: The calculated strain values from measured strains in all measurement sites and loading conditions for the screw-retained two-implant intercanine porcelain fused to a metal bridge and a cast framework partial denture with precision attachments situation were lower than in the other scenarios (P<0.05). Conclusion: Within the limitations of the present study, it can be concluded that an IARD may be a reasonable and valuable alternative to ball attachments or a bar in two interforaminal implants, especially when the patients prefer to be able to show their teeth even when they take out their removable dentures.

무치악 환자에서 기성 조립식 bar를 이용한 임플란트 피개의치 증례 (Implant-retained overdentures with pre-fabricated bar attachment system in edentulous patients)

  • 소나영;홍영기;하승룡
    • 대한치과보철학회지
    • /
    • 제54권1호
    • /
    • pp.41-48
    • /
    • 2016
  • 치아 상실에 이어 심각한 치조골 소실을 보이는 무치악 환자들은 전통적인 방식의 총의치를 사용하는데 어려움이 많다. 이러한 문제를 보완할 수 있도록 임플란트를 이용한 피개의치가 사용되고 있다. SFI-bar$^{(R)}$는 진료실에서 직접 조정이 가능한 기성품으로 복잡한 기공과정을 필요로 하는 기존의 바 시스템보다 간결하여 시간과 비용을 절감할 수 있다. 첫 번째 증례는 55세 남자 환자로 기존 하악 임플란트-지지 피개의치가 파절되었다는 주소로 내원하였고 내구성이 있으며 통증이 없는 의치를 원하였다. 파절된 Locator$^{(R)}$ 어태치먼트를 제거 후 바를 이용한 피개의치로 치료하였다. 두 번째 증례는 파킨슨병을 앓고 있는 77세 여자 환자로 하악 치조골이 심각하게 흡수되어 의치가 자주 탈락한다는 주소로 내원하였고 통증이 없고 유지력이 있는 의치를 원하였다. 하악 전치부에 두개의 임플란트를 식립한 후 임플란트에 연결된 어댑터에 바를 연결하였다. 그 후 바에 맞는 여성부를 새로운 의치에 장착하여 치료하였다. 2년의 추적 관찰 결과 상기 환자 모두 심미적, 기능적으로 만족할만한 결과를 보였으므로 증례를 보고하고자 한다.

완전 무치악 환자에서 하악 임플란트 지지 피개의치 사용 후의 환자만족도에 관한 전향적 연구 (A prospective study of patient satisfaction after implant supported mandibular overdenture treatment in fully edentulous patients)

  • 홍주희;정겨운;신상완;방은경
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.1-8
    • /
    • 2015
  • 목적: 이 연구의 목적은 하악 임플란트 지지 피개의치와 전통적인 총의치의 환자 만족도를 비교하기 위함이다. 재료 및 방법: 하악 임플란트 지지 피개의치 치료가 계획된 40명의 상하악 완전 무치악 환자(51세 - 82세)를 대상으로 하였고, 모든 환자는 저작기능, 발음, 심미, 통증, 전반적인 만족도를 기존의 총의치 장착 시와 임플란트 지지 피개의치 장착 1주 후, 12주 후에 visual analog scale법을 이용하여 답하였다. 각 시기의 만족도 비교를 위해 반복측정 분산분석(repeated-measures ANOVA)을 시행하였다(P<.05). 결과: 모든 설문 항목에서 임플란트 지지 피개의치 장착 1주 후, 12주 후에 총의치를 장착했을 때보다 높은 만족도를 보였다(P<.05). 임플란트 지지 피개의치 장착 12주 후에 저작기능, 발음, 통증, 전반적인 만족도는 장착 1주 후에 비해 증가된 결과를 보였고, 심미에 대한 만족도와 전체적인 만족도는 감소함을 나타냈으나, 통계적인 유의성을 보이지는 않았다. 결론: 임플란트 지지 피개의치는 기존의 총의치에 만족하지 못하는 환자들의 만족도를 높임으로써 환자의 삶의 질을 개선시킬 수 있는 효과적인 치료 방법 중 하나가 될 수 있으리라 생각된다.

자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구 (A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment)

  • 서민지;이준석;조인호
    • 구강회복응용과학지
    • /
    • 제24권2호
    • /
    • pp.169-181
    • /
    • 2008
  • 치과용 자석의 개선으로 자성 어태치먼트를 이용한 임플란트 피개의치의 사용이 늘고 있다. 또한 여러 형태의 자성 어태치먼트가 개발되어 임상 상황에 따라 적절히 선택하여 사용할 수 있게 되었다. 이에 시중에 판매되는 세 가지 형태의 임플란트용 자성 어태치먼트를 이용해 자성 어태치먼트의 형태와 임플란트 수에 따른 임플란트 피개의치의 유지력을 비교 분석하였다. 식립된 임플란트가 1개인 경우를 1군, 2개인 경우 2군, 4개인 경우를 3군으로 하였고, 자성 어태치먼트의 형태에 따라 flat type, cushion type, dome type으로 세분하였다. Instron으로 수직방향, 사선방향, 전후방향의 인장력을 가하여 자성 어태치먼트의 형태에 따른 유지력의 차이, 힘의 방향에 따른 유지력의 차이, 자성 어태치먼트의 수에 따른 유지력의 변화를 비교 분석하여 다음의 결과를 얻었다. 1) 임플란트의 수와 상관없이 수직력은 flat type이 가장 컸으며, 측방력은 dome type이 가장 작은 것으로 나타났다. 2) 임플란트가 1개일 때 flat type의 수직력이 전후방회전력보다 크게 나타났고, 임플란트가 2개일 때는 dome type과 flat type이, 임플란트가 4개일 때는 cushion type과 flat type에서 수직력이 전후방회전력보다 크게 나타났다. 3) 임플란트 수에 따른 유지력 측정결과, 자석의 형태에 상관없이 임플란트 수가 많을수록 유지력은 증가하였다. 이상의 결과로 볼 때, 큰 유지력이 필요한 환자에게는 flat type이, 유해한 수평력이 존재하는 환자에게는 dome type의 이용이 유리하고, 임플란트가 1개일 때 flat type, 2개일 때 dome type과 flat type, 임플란트가 4개일 때 cushion type과 flat type이 피개의치의 안정성이 더 좋은 것으로 나타났다. 또한 자성 어태치먼트의 형태에 상관없이 임플란트의 수가 증가할수록 더 큰 유지력을 나타냈다. 따라서 임플란트 피개의치 사용 시 적절한 유지력과 안정성을 얻기 위해서 임플란트의 수와 자성 어태치먼트 형태의 고려가 필요하다고 사료된다.

무치악 환자에서 하악 임플랜트 지지 피개의치에 의한 즉시 하중 부담에 관한 연구 (NOVEL TREATMENT MODALITY OF IMPLANT-RETAINED OVERDENTURE FOR IMMEDIATE FUNCTION IN COMPLETELY EDENTULOUS PATIENTS)

  • 김장욱;김형섭;백진;권긍록
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.34-47
    • /
    • 2007
  • Statement of problem: Conventional mandibular complete denture lacks in support and stability for edentulous patients to use. Purpose: To enhance support and stability of mandibular complete denture, 2 implants were inserted on the inter-mental foramina space of edentulous patients. With 2 magnetic attachments on the inner side of the overdenture, we gave immediate loads and evaluated the stability of the implants, the responses of the supporting tissues, and the satisfaction of the patients. Material & methods: 6 edentulous patients (5 male, 1 female) each recieved 2 SLA implants in the inter-mental foramina region and implants were immediately loaded with overdenture with magnet attachments. To evaluate the implants stability and the peri-implant tissues, clinical exams, RFA tests and radiographic exams were preformed at the 1 week, 2wks, 6wks, 12wks, and 24wks. post- surgery. Results: The mean surgery time was $45.7{\pm}7.7mins$., while the denture delivery time was $45.5{\pm}12.6mins$. Only 2 of 14 implants were failed. Survived implants that remained were clincally and radiographically stable. Mean ISQ values were relatively stable, showing $69.71{\pm}5.55$, $69.00{\pm}9.48$, $67.92{\pm}7.86$, $67.92{\pm}9.58$, $70.08{\pm}7.61$, $71.92{\pm}6.43$ at the 1 wk, 2 wks, 6 wks, 12 wks, 24 wks. follow up check. Crestal bone changes were $-1.18mm{\pm}0.68mm$, $-1.35{\pm}0.69mm$, $-1.47{\pm}0.68mm$ at the 6wks, 12wks, 24wks. follow up check. Bleeding on probing(BOP index) was not significant. Conclusion: Mandibular ovedentures with 2 magnetic attachments over two interforaminal implants on edentulous patients for immediate function is a recommendable novel treatment for edentulous patients which shows stability on the implants and supporting tissue.

임플랜트 Overdenture의 Bar설계에 따른 하악지지조직의 광탄성학적 응력분석 (PHOTOELASTIC STRESS ANALYSIS ON THE MANDIBLE CAUSED BY IMPLANT OVERDENTURE)

  • 강정민;방몽숙
    • 대한치과보철학회지
    • /
    • 제32권2호
    • /
    • pp.327-353
    • /
    • 1994
  • This study was performed to evaluate the effects of number and alignment of implant fixture and various bar designs on the retention of denture and the stress distribution. Six kinds of photoelastic mandibular models and nine kinds of overdenture specimens were designed. A unilateral vertical load was gradually applied on the right first molar to calculate the maximal dislodgement load of each specimen. A unilateral vertical load of 17 Kgf was applied on the right first molar and a vertical load of 10 Kgf was applied on the interincisal edge region. The stress pattern which developed in each photoelastic model was analyzed by the reflection polariscope. The results obtained were as follows: 1. The maximal dislodgement load reversely increased with the distance from the loading point to the implant fixture, while it linearly increased with that from the most posterior implant fixture to the mesial clip. The maximal dislodgement load also increased with the use of a cantilever bar. 2. Under the posterior vertical load, the stress to the supporting tissue of the denture base increased with the distance from the loading point to the implant future. The stress concentration on the apical area of the implant future reversely increased with the distance from the loading point to the implant future. 3. In the overdentures supported by two implant fixtures under the posterior vertical load. the specimen implanted on lateral incisor areas with a cantilever bar exhibited more favorable stress distribution than that without a cantilever bar. The specimen implanted on the canine areas without a cantilever bar, however, exhibited more favorable stress distribution. 4. In the overdentures supported by three implant fixtures. the specimen implanted ell the midline and canine areas exhibited more favorable stress distribution than that implanted oil the midline and the first premolar areas. 5. In the overdentures supported by four implant fixtures. the specimen implanted with two adjacent implant fixtures exhibited more favorable stress distribution than that implanted at equal distance under the posterior vertical load. 6. Under the anterior vertical load, the overdentures supported by three implant fixtures exhibited stress concentration on the supporting structure of the middle implant future. In overdentures supported by two or four implant futures, no significant difference was noted in stress distribution between the types of bars. These results indicate that the greater the number of implant fixtures, the better the stress distribution is. A favorable stress distribution may be obtained in the overdentures supported by two or three implant fixtures, if the location and the design of the bar are appropriate.

  • PDF

Evaluation of bite force, quality of life, and patients' satisfaction in elderly edentulous patients using implant overdentures

  • Esra Nur Avukat;Canan Akay;Emre Mumcu
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권4호
    • /
    • pp.214-226
    • /
    • 2023
  • PURPOSE. This study aimed to compare the bite force (BF) between complete dentures and implant overdentures (IODs) retained by two mandibular implants. Additionally, we evaluated the quality of life (QoL) and patient satisfaction among individuals using IODs. In addition, the effects of demographic parameters such as age and sex, and clinical parameters such as implant length, implant diameter, attachment height, attachment color, and interimplant distance on BF, QoL, and patient satisfaction were evaluated. MATERIALS AND METHODS. A total of 51 edentulous patients rehabilitated with the maxillary complete dentures and mandibular IODs retained by two implants were included in this study. BF was measured using a force meter pre- and post-implant in the same patients. Oral health-related quality of life (OHRQoL) was assessed with the Oral Health Impact Profile (OHIP-14) and patient satisfaction was assessed with the Visual Analog Scale (VAS) questionnaires. RESULTS. It was found that BF values were statistically higher for IODs than complete dentures (P < .001). In terms of attachment height of the OHIP scores, there was a significant difference in the psychological disability and social disability domains (P < .05). When examining the change in patient satisfaction as a function of sex, it was found that mandibular retention satisfaction differed significantly by sex (P < .05), but there was no significant difference in the other domains. CONCLUSION. Within the limitations of this study, it was observed that the BF increased after the use of IODs. Several factors, including age, interimplant distance, attachment height, and attachment color, were found to impact OHRQoL. Sex and implant diameter were identified as factors affecting patient satisfaction.

CAD-CAM으로 제작된 임플란트 피개의치를 이용한 무치악 환자의 보철 수복 증례 (Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report)

  • 이한나;심지석;이정열
    • 대한치과보철학회지
    • /
    • 제60권4호
    • /
    • pp.374-381
    • /
    • 2022
  • 본 증례는 74세 남환으로 20년 전 제작한 하악 임플란트 피개의치의 잦은 탈락을 주소로 내원하였다. 기존 의치 사용 시 수직고경이 감소되었으며, 상악 총의치는 입술 지지 및 유지력이 부족하였으며, 하악 피개의치는 bar attachment 손상으로 clip의 유지력 부족이 관찰되었다. 손상된 bar attachment를 제거 후 ball attachment로 교체하였으며, DENTCATM Tray를 이용하여 인상 채득, 수직고경을 측정하고, 고딕 아치 기록방법으로 중심위를 결정하여 교합기록을 시행하였다. 채득한 인상체를 스캔하여 소프트웨어를 이용하여 최종 의치의 형태를 디자인하였고, 3D 프린터로 시적의치를 제작하였다. 제작된 시적의치를 장착하여 교합평면 및 교합관계, 안모 형태, 발음 등을 평가한 후 교합기록을 하였으며, 이를 바탕으로 최종 의치를 제작하였다. 최종 의치의 내면 조정 및 양측성 균형교합을 형성하였으며, 하악 의치에서는 직접법으로 attachment를 연결하였다. 새로 제작된 상하악 의치 사용 시, 수직고경의 증가 및 입술지지를 회복하여 개선된 안모가 관찰되었으며, ball attachment 교체로 하악 임플란트 피개의치의 유지력이 증가하여 기능적으로도 만족할 만한 결과를 얻었기에 이를 보고하는 바이다.

하악 임플란트 오버덴쳐에서 어태치먼트 종류에 따른 응력분포 (The Influence of Attachment Type on the Distribution of Occlusal Force in Implant Supported Overdentures)

  • 성채련;조인호
    • 구강회복응용과학지
    • /
    • 제25권4호
    • /
    • pp.375-390
    • /
    • 2009
  • 하악 완전 무치악 환자에서 이공 사이에 2개의 임플란트를 식립한 후 4종류의 어태치먼트를 사용한 하악 오버덴쳐를 제작하여 유한요소 모델을 만들고 여기에 3가지 하중 조건을 가하여 유한요소 해석 프로그램인 ANSYS 10.0을 이용하여 어태치먼트 종류에 따른 임플란트 주위골과 보철물 및 임플란트와 골 사이 계면에 발생하는 최대 응력의 크기와 응력 분포양상을 분석하였다. 하악골체의 전체적인 골격구조에서 치아 부분은 오버덴쳐로 모델을 형성하였고 오버덴쳐와 하악골 사이에 2mm 두께의 점막을 삽입하였다. 임플란트 오버덴쳐의 유한요소 모델은 ball and socket, Locator, magnet, bar의 각각 4가지 형태를 제작하였다. 고정체의 식립 위치는 양측 이공 전방이고, 경계 조건 중 고정점은 하악각 부위와 모형의 최후방 절점들을 고정점으로 설정하였다. 하중조건은 오버덴쳐의 좌측 제 2소구치에서 제 2대구치 편측 부위에 170N의 하중을, 좌 우측 제 2소구치에서 제 2대구치 양측 부위에 170N의 하중을, $90^{\circ}$수직 방향, $45^{\circ}$경사, 그리고 $0^{\circ}$ 수평 방향으로 가하였다. 결과 분석시 모든 하중방향에서 응력의 크기는 bar에서 임플란트나 오버덴쳐에서 가장 크게 나타났으며, 계면에서의 응력은 모든 어태치먼트에서 비슷한 응력분포가 나타났다. Ball and socket, Locator, magnet에서는 유의성을 보이지 않았다. 응력의 분포도에서는 4종류의 어태치먼트 모두 임플란트 치경부에서 응력이 집중된 양상을 보였으며 bar타입에서는 bar의 중앙에 응력이 크게나타났다. 이상의 결과로 볼 때 어태치먼트의 종류에 따라 응력분포의 차이가 있었음을 확인할 수 있었다. 어태치먼트의 선정 시 응력집중을 완화시킬 수 있는 바람직한 설계와 선택이 필요하리라 사료된다.

심한 하악 치조제 흡수를 가진 환자에서 임플란트를 이용한 가철성 국소의치로 수복한 증례 (Implant-assisted removable partial denture for severely atrophied mandible)

  • 최바다;김연주;이재훈
    • 대한치과보철학회지
    • /
    • 제57권2호
    • /
    • pp.171-175
    • /
    • 2019
  • 치조제가 심하게 흡수된 하악의 정확한 해부학적 구조를 채득하는 것은 매우 어렵다. 이 경우 보다 정확한 인상을 채득하기 위하여 수정모형 제작법을 통한 기능 인상 채득이 추천된다. 이를 위해서는 양측에 2개의 임플란트 크라운을 이용하여 적절한 고정원을 얻을 필요가 있다. 이를 통해 임플란트 피개의치에서는 불가능하였던 수정모형 제작법을 시행할 수 있다. 본 증례에서는 하악의 치조제가 심하게 흡수된 80세 여환을 하악 양측 견치 부위의 임플란트 크라운을 지대치로 한 가철성 국소의치를 이용하여 수복하였다. 가철성 국소의치의 금속구조물을 이용하여 개인 트레이를 제작하고 수정모형 제작을 위한 이차 인상을 채득하였다. 환자는 앞선 2회의 피개의치 실패 후 제작된 최종 보철물에 만족하였다. 치료 초기에 행해진 피개의치 치료에서는 부정확한 인상법에 따른 부적절한 보철물로 인해 술자와 환자 모두 만족하지 못했지만, 2개의 임플란트를 적절한 고정원으로 이용함으로써 성공적인 수복이 가능하였다.