Browse > Article
http://dx.doi.org/10.4047/jkap.2022.60.4.374

Rehabilitation of the edentulous patient with implant overdenture using CAD-CAM denture system: A case report  

Lee, Han-na (Department of Dentistry, Korea University Guro Hospital)
Shim, Ji-Suk (Department of Dentistry, Korea University Guro Hospital)
Lee, Jeong-Yol (Department of Dentistry, Korea University Guro Hospital)
Publication Information
The Journal of Korean Academy of Prosthodontics / v.60, no.4, 2022 , pp. 374-381 More about this Journal
Abstract
This case report introduces a 74-year-old male patient who visited retention deficiency of the mandibular implant overdenture, which was fabricated 20 years ago. When the existing dentures were used, the vertical dimension was reduced, the maxillary complete denture lacked lip support and retention, and the mandibular overdenture lacked clip retention due to damage to the bar attachment. After removing the damaged bar attachment, it was replaced with a ball attachment, and impressions were taken using the DENTCATM Tray and then the vertical dimension was measured. The gothic arch tracing was performed to record the centric relation. Obtained impressions were scanned and the shape of final dentures was designed using software and try-in dentures were fabricated using 3D printer. After evaluating the occlusal plane, occlusal relationship, facial shape, and pronunciation using the try-in dentures, the bite registration was recorded, and the final denture was manufactured based on this. The inner surface of the denture was adjusted and bilateral balanced occlusion was formed, and the housing was connected to the mandibular denture by a direct method. This case reports have shown satisfactory resultin recovering improved retention and esthetic outcome by increasing the vertical dimension and the lip support using CAD-CAM technique and the ball attachment.
Keywords
CAD-CAM; Complete denture; Overdenture;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Srinivasan M, Kamnoedboon P, McKenna G, Angst L, Schimmel M, Ozcan M, Muller F. CAD-CAM removable complete dentures: A systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes. J Dent 2021;113:103777.   DOI
2 Nissan J, Oz-Ari B, Gross O, Ghelfan O, Chaushu G. Long-term prosthetic aftercare of direct vs. indirect attachment incorporation techniques to mandibular implant-supported overdenture. Clin Oral Implants Res 2011;22:627-30.   DOI
3 Kuscu E, Klink A, Spintzyk S, Kraemer Fernandez P, Huettig F. Bonding interface and repairability of 3D-printed intraoral splints: shear bond strength to current polymers, with and without ageing. Materials (Basel) 2021;14:3935.   DOI
4 Thomason JM, Feine J, Exley C, Moynihan P, Muller F, Naert I, Ellis JS, Barclay C, Butterworth C, Scott B, Lynch C, Stewardson D, Smith P, Welfare R, Hyde P, McAndrew R, Fenlon M, Barclay S, Barker D. Mandibular two implant-supported overdentures as the first choice standard of care for edentulous patients-the York Consensus Statement. Br Dent J 2009;207:185-6.   DOI
5 McLaughlin JB, Ramos V Jr. Complete denture fabrication with CAD/CAM record bases. J Prosthet Dent 2015;114:493-7.   DOI
6 Bidra AS, Taylor TD, Agar JR. Computer-aided technology for fabricating complete dentures: systematic review of historical background, current status, and future perspectives. J Prosthet Dent 2013;109:361-6.   DOI
7 Schmidt MB, Rauch A, Schwarzer M, Lethaus B, Hahnel S. Combination of digital and conventional workflows in the CAD/CAM-fabrication of an implant-supported overdenture. Materials (Basel) 2020;13:3688.   DOI
8 Kim HY, Lee JY, Shin SW, Bryant SR. Attachment systems for mandibular implant overdentures: a systematic review. J Adv Prosthodont 2012;4:197-203.   DOI
9 van Kampen F, Cune M, van der Bilt A, Bosman F. Retention and postinsertion maintenance of barclip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res 2003;14:720-6.   DOI
10 Gonda T, Maeda Y, Walton JN, MacEntee MI. Fracture incidence in mandibular overdentures retained by one or two implants. J Prosthet Dent 2010;103:178-81.   DOI
11 Abduo J, Lyons K. Clinical considerations for increasing occlusal vertical dimension: a review. Aust Dent J 2012;57:2-10.   DOI