• Title/Summary/Keyword: Maintenance standard

Search Result 1,088, Processing Time 0.031 seconds

Health Promoting Lifestyles of Korean Employees (근로자의 건강증진 생활양식 실천에 관한 연구)

  • Cho, Tong Ran;Park, Eun Ok
    • Korean Journal of Occupational Health Nursing
    • /
    • v.7 no.1
    • /
    • pp.33-46
    • /
    • 1998
  • Introduction : In Korea, national attention to the workplace health promotion programs (HPP) for employees began in early 1990s. Governmental supports for the HPP and education programs have given to the employees. The purpose of this study is to find the performance degree of employees' health promoting lifestyle(HPL). Subjects and Methods : For this study, 615 employees who attended governmental educations were selected as research samples. The tool for measuring HPL used in this study was developed for Korean by In-Sook Park in 1995. It is composed of 4-point scaled 60 items and divided into 11 subcategories. The data were collected by self reporting questionnaires from June to December in 1997. Those data were analyzed percentile, mean, standard deviation, ANOVA, t-test with SAS program. Major findings are as follows; 1. The total mean score of the employees' HPL performance was 2.66. The average scores of 'harmonious relationships' category were the highest as 3.11, whereas the one of 'professional health maintenance' were the lowest as 2.02. The remains were 'sanitary life'(2.90), 'emotional support(2.85), 'regular diet'(2.84), 'self achievement'(2.78), 'healthy diet'(2.56), 'rest and sleep'(2.56), 'exercise and activity'(2.54), 'diet control'(2.53), 'self-control'(2.52). 2. The factors affecting HLP were category of industries and sex, age, marital status, education level, major, educational experience of health promotion, among personal characteristics. The employees of service industries, female, older age, married, nurse, educated for health promotion, graduated from junior college performed HLP more than the others. 3. The participation rates of employees for HPP were 12.4%, because of limited time and facilities and equipments. Recommendations; 1. The regulation for performing the health promotion programs in the industries is essential for activating industrial health promoting movement. 2. More governmental supports for educations and services for health promotion programs in the industries are needed. 3. For behavioral changes of the employees, the contents of educations have to consist of exercise and activity, rest and sleep, diet and smoking habits. 4. The evaluating studies for ready made health promotion programs in the industries are expected.

  • PDF

Reliability Analysis and Utilization of BIM-based Highway Construction Output Volume (BIM기반 고속도로 공사 물량산출 신뢰성 검토 및 활용)

  • Jung, Guk-Young;Woo, Jeong-Won;Kang, Kyeong-Don;Shin, Jae-Choul
    • Journal of KIBIM
    • /
    • v.3 no.3
    • /
    • pp.9-18
    • /
    • 2013
  • In case of applying the BIM method in the civil engineering of irregularly shaped structure, BIM method began to be introduced in the current building engineering area compared with the expected effects of the relatively high construction productivity has been recognized. In this paper, I have developed quantity calculation algorithms applying it to earthwork and bridge construction, tunnel construction, retaining wall construction, culvert construction and implemented BIM based 3D-BIM Modeling quantity calculation. Structure work in which errors occurred in range between -6.28% ~ 5.17%. Especially, understanding of the problem and improvement of the existing 2D-CAD based of quantity calculation through rock type quantity calculation error in range of -14.36% ~ 13.07% of earthwork quantity calculation. It's benefit and applicability of BIM method in civil engineering. In addition, routine method for quantity of earthwork has the same error tolerance negligible for that of structure work. But, rock type's quantity calculated as the error appears significantly to the reliability of 2D-based volume calculation shows that the problem could be. Through the estimating quantity of earthwork based 3D-BIM, proposed method has better reliability than routine method. BIM, as well as the design, construction, maintenance levels of information when you consider the benefits of integration, the introduction of BIM design in civil engineering and the possibility of applying for the effectiveness was confirmed. In addition, as the beginning phase of information integration, quantity document automation program has been developed for activation of BIM. And automatically enter the program code number, linkage and manual volume calculation program, quantity document automation programs, such as the development is now underway, and step-by-step procedures and methods are presented.

A Study on Design Method depending upon Low Carbon Green Architecture of Big Medical Center (대형의료기관 건축물에 대한 저탄소 녹색 친환경 설계 방안에 관한 연구)

  • Kim, Jong Gu;Park, Jong Min
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.987-996
    • /
    • 2015
  • According to the recent research results of the Ministry of Environment, the indoor air quality of large general hospitals and university hospitals(58 hospitals) exceeded the maintenance standard. On top of such indoor air quality, it is also desperately required to have the environment-friendly building design and also low carbon green design in accordance with the increase of hospital size and enlarged hospital buildings. Especially, the increase of carbon dioxide, heat, garbage, waste energy, exhaust heat from power plants and sewage heat in each medical center brings up lots of problems to the health of hospital patients and customers. Thus this study aims to convergently develop the green environment-friendly architecture design technology concerning the organic relations between each medical building, and technical development which should be introduced to the low carbon green environment-friendly architecture design based on the characteristics of each medical center in large-scale medical complex.

Comparative Study on the Technical Standards for the In-Service Inspection of Nuclear Power Plant Components in Several Countries (원전의 가동중검사 관련 각국의 기술기준 비교고찰)

  • Shin, Ho-Sang;Kim, Kyung-Jo;Jang, Chang-Heui;Kang, Suk-Chull
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.186-196
    • /
    • 2004
  • In each country, the periodic ISI(In-Service Inspection) is required by the law to protect the public health and property from the potential accident of the nuclear facilities. To support the implementation of ISI program, the prescriptive ISI technical standards have been established. As the key parts of the ISI program, the non-destructive examination techniques are widely used to identify the degree of degradation of the pressure boundary components and welds. Recently, the risk informed-ISI program has been developed and implemented in several countries. Nonetheless, the existing ISI program which prescriptively decides the scope of inspection still has its own significance. In this article, the technical standards of ISI in leading countries like US, france, Canada, and Japan are reviewed and compared with the safety guide by IAEA. An outline to revise the domestic technical standards of ISI has been suggested.

Asbestos Content in Friable Sprayed-on Surface Material and Airborne Fiber Concentrations in Commercial Buildings (대형건물내 비고형 석면함유 건축자재에 의한 기중 석면오염 및 관리실태)

  • Kim, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.137-146
    • /
    • 1995
  • Twenty(20) large commercial buildings located in Seoul with friable sprayed-on surface insulation material on ceilings were investigated for asbestos content in bulk material by polarized light microscopy and for airborne fiber concentrations in buildings by phase contrast microscopy. In addition, such building-related variables as building age, numbers of traffic, airflow, surface conditions of the ceiling, temperature, and humidity were studied for any correlation with airborne fiber concentrations. The results were as follows: 1. Chrysotile asbestos was found in two bulk samples with 3-5% content and with <1%in one sample out of total 20 bulk samples collected. Glass fiber and mineral wool were the two major constituents of the bulk samples. 2. The ceiling surfaces were very friable in 16 buildings and were relatively hard in 4 buildings. The friability of the surface material was dependent upon the type and the amount of binder that had been mixed with the sprayed-on surface material. 3. Airborne fiber concentrations were log-normally distributed and the geometric mean(geometric standard deviation) fiber concentrations in the underground parking lots, inside buildings, and outdoor ambient air were 0.0063(1.97)f/cc, 0.0068(2.29)f/cc, and 0.0033(2.36)f/cc, respectively. 4. No significant relationship of airborne fiber concentrations and all building-related variables studied except humidity was found. The results of this study suggest that the sprayed-on surface insulation material found in some commercial buildings may possibly be contaminated with asbestos. Since most of the ceiling surfaces surveyed were very friable and poorly maintained and the airborne fiber concentrations were relatively high, there is a possibility of asbestos fiber contamination in these buildings, particularly at those buildings with asbestos-contaminated surface material. Since poorly maintained surface conditions were thought to be a source of high airborne fiber concentrations, there is a urgent need of a systematic operation and maintenance program. Further study of non-occupational asbestos exposure in general population utilizing advanced analytical technique such as transmission electron microscopy is highly recommended.

  • PDF

Small Incision and Dual-Top Screws for Treatment of Simple Depressed Anterior Frontal Sinus Fractures (소절개 및 Dual-top screw를 이용한 전두동 전벽 단순 함몰골절의 치료)

  • Moon, Suk Ho;Oh, Deuk Young;Seo, Byung Chul;Rhie, Jong Won;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.35 no.3
    • /
    • pp.345-348
    • /
    • 2008
  • Purpose: Fracture of the frontal sinus accounts for 5-15% of all facial fractures. Only anterior table fracture occupies one third of the frontal sinus fracture. Conventional coronal approach is the standard treatment, but this method is very aggressive, especially in patient with simple, depressed, anterior frontal sinus wall fracture. We introduce new, simple technique for these patients, using small incision and Dual-top screws. Methods: A 27-year-old male patient was introduced to our department under the impression of fracture of frontal sinus, involving only anterior table. Under general anesthesia, 1.5 cm-sized, small incision was made on the suprabrow area. We reduced fractured fragment with two dual-top screws and 25G wires. Fixation was not necessary Results: The operation took about forty minutes, and the patient discharged 2 days after the operation. Postoperative 2 months follow up CT shows maintenance of reduction site. Gross depression of the forehead and visible scar was not observed. Conclusion: Although the indication of this procedure is limited, less aggressive, simple and very effective to the patient with simple. depressed, anterior frontal sinus fracture.

Cost-Effectiveness Analysis of Low-Impact Development Facilities to Improve Hydrologic Cycle and Water Quality in Urban Watershed (도시유역의 물순환 및 수질 개선을 위한 저영향개발 시설의 비용 효율 분석)

  • Choi, Jeonghyeon;Kim, Kyungmin;Sim, Inkyeong;Lee, Okjeong;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.3
    • /
    • pp.206-219
    • /
    • 2020
  • As urbanization and impermeable areas have increased, stormwater and non-point pollutants entering the stream have increased. Additionally, in the case of the old town comprising a combined sewer pipe system, there is a problem of stream water pollution caused by the combined sewer overflow. To resolve this problem, many cities globally are pursuing an environmentally friendly low impact development strategy that can infiltrate, evaporate, and store rainwater. This study analyzed the expected effects and efficiency when the LID facility was installed as a measure to improve hydrologic cycle and water quality in the Oncheon stream in Busan. The EPA-SWMM, previously calibrated for hydrological and water quality parameters, was used, and standard parameters of the LID facilities supported by the EPA-SWMM were set. Benchmarking the green infrastructure plan in New York City, USA, has created various installation scenarios for the LID facilities in the Oncheon stream drainage area. The installation and maintenance cost of the LID facility for scenarios were estimated, and the effect of each LID facility was analyzed through a long-term EPA-SWMM simulation. Among the applied LID facilities, the infiltration trench showed the best effect, and the bio-retention cell and permeable pavement system followed. Conversely, in terms of cost-efficiency, the permeable pavement systems showed the best efficiency, followed by the infiltration trenches and bio-retention cells.

Evaluation and Analysis of Characteristics for Hazen-Williams C Based on Measured Data in Multi-Regional Water Supply Systems (광역상수도 실측자료를 활용한 유속계수 평가 및 특성 분석)

  • Kim, Bumjun;Choi, Myungwon;Kim, Gilho;Kim, Hungsoo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.197-206
    • /
    • 2016
  • Although the Hazen-Williams C factors are very important in the design, operation, and maintenance of water supply pipes, sufficient studies for them have been not reported in korea, which are based on experiments or measured data. Because of this, we have estimated C factors by measurement considering constraints in time precise safety diagnosis for multi-regional water supply system were performed. In this study, we confirmed constraints and variables characteristics of Hazen-Williams equation, and collected reliable C factors data of 174 by measurement, and analyzed their characteristics. According to collected data, the average value is 115.35, which is almost equal to the value of design standard or a little higher than it in korea. Also, among the equations suggested to determine C factor in the past, the C factors calculated by Sharp and Walski equation was closest to them in this study. In addition, to analyze collected C factors, use year and pipe diameter having high correlation with them were respectively divided into there categories. Analysis results showed that C factors evidently decreases depending on increases in use year, on the other hand, size of pipe diameter is proportional to value of them. In conclusion, this research showing evaluation and characteristics for C factors based on measured data will be used as practical reference in determining C factor in multi-regional water supply systems at a later date.

Case Studies on the Field Application of Miniature CPT's in South Korea (소형콘관입시험(Miniature CPT)의 국내현장적용 사례분석)

  • Yoon, Sung-Soo;Hwang, Dae-Jin;Kim, Jun-Ou;Ji, Wan-Goo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.269-281
    • /
    • 2010
  • The cone penetration test(CPT) has been increasingly used for in situ site characterization. However, the use of CPT is often limited due to specific site conditions depending on the cone size, geometry, and capacity of the CPT system used. In South Korea, it has generally been considered that the CPT could be satisfactorily performed only in soft soils. Louisiana State University/ Louisiana Transportation Research Center has implemented a field-rugged continuous intrusion miniature cone penetration test (CIMCPT) system since the 1990s. The miniature cone penetrometer of the CIMCPT system has a cross-sectional cone area of $2cm^2$ allowing finer soil profiles compared to the standard $10cm^2$. The reduced cross-sectional area also enables a system capacity reduction leading to cost saving and ease in maintenance. In addition, the continuous intrusion mechanism allows fast and economic site investigations. Samsung C&T Corporation has recently implemented a similar CIMCPT system. In this study, case studies on the field application of Samsung CIMCPT system for the last 2 years are presented to illustrate its performance investigation and its usefulness and limitation. Results of the case studies show that the CIMCPT system can be applied to soils with cone tip resistance($q_c$) values up to about 30MPa and allows a reliable and useful way to characterize soft soils. The results also show that the rod buckling limits the investigation depth by the system and the large contact pressure of the CIMCPT truck prevents the use of the system at sites with soft surface soils. According to the results of the case studies, the Samsung CIMCPT system has been being upgraded with a miniature cone with a longer rod, a crawler-type transportation system, a pre-boring system, and so on.

  • PDF

Operating model for A Value-For-Money evaluation of BTL Projects for Educational Facilities (교육시설 BTL 사업의 투자가치 평가를 위한 운영비 모형 구축)

  • Son, Ki-Young;Kim, Jang-Young;Kook, Dong-Hoon;Kim, Sun-Kuk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.6
    • /
    • pp.141-150
    • /
    • 2006
  • As the law on the private sector investment in social infrastructure was amended in January of 2005, the government is aggressively promoting BTL projects but many trials and errors and problems are occurring. Especially, the Value-For-Money evaluation conducted by the responsible agencies to judge the appropriateness of the project found there was a conspicuous difference between the computed cost and the final contract sum. Accordingly, this study is aimed to grasp the problems in the current Value-For-Money evaluation and to improve it in order to proceed with BTL projects efficiently. To achieve this, through a relative comparison to the final contract sum, a clear standard for the items of Value-For-Money evaluation was presented and thus, a model that can ensure accuracy in computing the Value-For-Money was established so that a delay in negotiations can be avoided. If the Value-For-Money evaluation established in this study is used in assessing the appropriateness of unit prices for BTL projects for education facilities, a reasonable result can be expected to be drawn in selection and negotiations with contractors, and maintenance and Post-Operation-Evaluation(POE) of education facilities as well.