• Title/Summary/Keyword: Magnetic Resonance

Search Result 6,490, Processing Time 0.025 seconds

Constructing Overhauser Dynamic Nuclear Polarization-Nuclear Magnetic Resonance System Using Benchtop Electron Paramagnetic Resonance Spectrometer

  • Saun, Seung-Bo;Kim, JiWon;Han, Oc Hee
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.22 no.2
    • /
    • pp.34-39
    • /
    • 2018
  • The Nuclear Magnetic Resonance (NMR) technique using Dynamic Nuclear Polarization (DNP) procedures is one of the promising techniques that enable overcoming low sensitivity problems in NMR spectroscopy. We constructed an ODNP-NMR system using a commercial benchtop EPR spectrometer. The $^1H$ NMR peak area of water in aqueous solutions of 4-hydroxy-TEMPO was enhanced more than 95 times in the ODNP-NMR experiments. Our signal enhancement results were about 55% of the previously reported result. This could be due to non-uniform microwave power over a sample and unwanted sample heating by microwave. However, this portable ODNP-NMR spectrometer will be eventually useful for site-specific detection with nano-scale spatial resolutions and molecular dynamics studies with significantly improved signal sensitivity.

113Cd and 133Cs NMR Study of Nucleus-Phonon Interactions in Linear-Chain Perovskite-Type CsCdBr3

  • Park, Sung Soo;Lim, Ae Ran
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.20 no.4
    • /
    • pp.109-113
    • /
    • 2016
  • Resonance frequencies from the $^{113}Cd$ and $^{133}Cs$ nuclear magnetic resonance (NMR) spectra for the $CsCdBr_3$ single crystal were measured at varying temperatures by the static NMR method. The temperature-dependent changes of these frequencies are related to the changing structural geometry of the ${CdBr_6}^{4-}$ units, which affects the environment of $^{133}Cs$. The spin-lattice relaxation rates ($1/T_1$) for the $^{113}Cd$ and $^{133}Cs$ nuclei were measured in order to obtain detailed information about the dynamics of $CsCdBr_3$ crystals. The dominant relaxation mechanisms for $^{113}Cd$ and $^{133}Cs$ nuclei are direct single-phonon and Raman spin-phonon processes, respectively.

Electron Spin Resonance Line-widths of Carbon Nanotubes based on the Hyperfine Interaction

  • Park, Jung-Il;Cheong, Hai-Du
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.19 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • The Kubo formalism and utilizing the projection operator technique (POT) introduced by Kawabata, the electron spin resonance (ESR) line-shape formula for carbon nanotubes through the hyperfine interaction introduced earlier in terms of POT. We can see that the line-width decreases exponentially as the temperature increases. The spin relaxation time show gradual decrease as magnetic field becomes larger. The analysis reveals the peculiarities in spin relaxation inherent to one dimensional system at low temperature and weak magnetic fields. Thus, the present technique is considered to be more convenient to explain the carbon nanotubes as in the case of other optical transitions.

Synthesis and Evaluation of Oleanolic Acid-Conjugated Lactoferrin for β-Amyloid Plaque Imaging

  • Kim, Sung-Min;Kim, Dongkyu;Chae, Min Kyung;Jeong, Il-Ha;Cho, Jee-Hyun;Choi, Naeun;Lee, Kyo Chul;Lee, Chulhyun;Ryu, Eun Kyoung
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3671-3675
    • /
    • 2012
  • ${\beta}$-Amyloid accumulation in the brain is a pathological hallmark of Alzheimer's disease (AD). Since early detection of ${\beta}$-amyloid may facilitate more successful and timely therapeutic interventions, many investigators have focused on developing AD diagnostic reagents that can penetrate the blood-brain barrier (BBB). Oleanolic acid (OA) is a substance found in a variety of plants that has been reported to prevent the progression of AD in mice. In this study, we synthesized and evaluated a new radioligand in which OA was conjugated to lactoferrin (Lf, an iron-binding glycoprotein that crosses the BBB) for the diagnosis of AD. In an in vitro study in which OA-Lf was incubated with ${\beta}$-amyloid (1-42) aggregates for 24 h, we found that OA-Lf effectively inhibited ${\beta}$-amyloid aggregation and fibril formation. In vivo studies demonstrated that $^{123}I$-OA-Lf brain uptake was higher than$^{123}I$-Lf uptake. Therefore, radiolabeled OA-Lf may have diagnostic potential for ${\beta}$-amyloid imaging.

Comparative Evaluation of North American Symptomatic Carotid Endarterectomy Trial and Warfarin-Aspirin Symptomatic Intracranial Disease Methods for Measurement of Middle Cerebral Artery Stenosis in Digital Subtraction Angiography and Magnetic Resonance Angiography (디지털 감산 혈관조영술과 자기 공명 혈관조영술에서 중대뇌동맥의 협착 측정을 위한 North American Symptomatic Carotid Endarterectomy Trial 및 Warfarin-Aspirin Symptomatic Intracranial Disease 방법의 비교 평가)

  • Lee, Jung-Hoon;Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.42 no.5
    • /
    • pp.351-356
    • /
    • 2019
  • This study aimed to determine whether there was a difference in measurements between North American Symptomatic Carotid Endarterectomy Trial(NASCET) and Warfarin-Aspirin Symptomatic Intracranial Disease(WASID) methods that measure the middle cerebral artery stenosis in Digital Subtraction Angiography (DSA) and Magnetic Resonance Angiography (MRA). It involved 24 patients who had completed both DSA and MRA among patients with Middle Cerebral Artery (MCA) stenosis. The Middle Cerebral Artery (MCA) stenosis was measured using the NASCET and WASID methods through a retrospective analysis. For the NASCET and WASID methods, they performed measurements on normal blood vessels located far from and close to the stenosis, respectively. The mean value and standard deviation of the Digital Subtraction Angiography (DSA) measured by the NASCET method were 59.23% and 13.27%. On the other hand, those of the Digital Subtraction Angiography (DSA) measured by the WASID method were 66.64% and 12.47%. And, the mean value and standard deviation of the Magnetic Resonance Angiography (MRA) measured by the NASCET method were 49.82% and 12.06%. By contrast, those of the Magnetic Resonance Angiography (MRA) measured by the WASID method were 56.63% and 10.67%. All the p-values obtained by the Pearson and Spearman correlation tests in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) were <0.01. In conclusion, this study suggests that both the NASCET and WASID methods to measure the middle cerebral artery stenosis in the Digital Subtraction Angiography (DSA) and the Magnetic Resonance Angiography (MRA) can be used if they are not used interchangeably.

[ $^{11}B$ ] Nuclear Magnetic Resonance Study of Spin Structures in Terbium Tetraboride

  • Mean, B.J.;Kang, K.H.;Kim, J.H.;Hyun, I.N.;Lee, Moo-Hee;Cho, B.K.
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.2
    • /
    • pp.197-202
    • /
    • 2006
  • [ $^{11}B$ ] nuclear magnetic resonance (NMR) measurements were performed on the single crystals of $TbB_4$ to investigate local electronic structure and 4f spin dynamics. $^{11}B$ NMR spectrum, Knight shift, spin-lattice and spin-spin relaxation rates were measured down to 4K at 8T. $^{11}B$ NMR shift and linewidth are huge and strongly temperature dependent due to the 4f moments. In addition, both are proportional to magnetic susceptibility, indicating that the hyperfine field at the boron site originates from the 4f spins of Tb. Below $T_N$, the single broad resonance peak of $^{11}B$ NMR splits into several peaks reflecting the local magnetic fields due to antiferromagnetic spin arrangements. The longitudinal and the transverse relaxation rates, $1/T_1\;and\;1/T_2$, independent of temperature above $T_N$, decreases tremendously confirming huge suppression of spin fluctuation below $T_N$.

  • PDF

Utility of Magnetic Resonance Imaging in the Diagnosis of Lung Adenocarcinoma with Extensive Necrosis: a Case Report

  • Choi, Sang Lim;Cha, Min Jae;Choi, Hye Won;Park, Byung-Joon;Kim, Mi Kyung;Kim, Jae Yeol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.4
    • /
    • pp.254-259
    • /
    • 2018
  • Application of magnetic resonance imaging (MRI) for assessment of pulmonary disease has been limited, due to susceptibility to cardiac pulsation, respiratory motion, and inhomogeneity of the magnetic field of the lung. With technical advances of MRI and unmet clinical needs for more accurate diagnosis and assessment of the disease, however, the use of MRI for evaluation of the lung has broadened. Herein, we present a case of pneumonic-type lung adenocarcinoma in a patient with history of anaphylactic shock to iodinated contrast medium, in which MRI played a critical role for targeted lung biopsy and cancer staging. Through this paper, we would like to report potential value of MRI in assessment of lung cancer.

Magnetic Resonance Neurography Using the Anisotropy of Diffusion Coefficients (확산계수의 이방성을 이용한 자기공명 신경망조영술)

  • Lee, Su-Yeol;Mun, Chi-Ung;Im, Tae-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.401-406
    • /
    • 1994
  • A magnetic resonance neurography technique for exclusive imaging of nerve networks is proposed. In the proposed technique, the anisotropy of diffusion coefficients of the molecules inside nerve cells was utilized to effectively suppress the magnetic resonance signal radiating from ones other than nerve tissues. Two images were obtained with diffusionweighting magnetic field gradients applied in the parallel and perpendicular directions with respect to the nerve orientation. One image was then subtract- ted from the other to form the neurogram. Experimentally obtained neurograms of the squld are presented.

  • PDF

Analysis of Magnetic Permeability Spectra of Metamaterials Composed of Cut Wire Pairs by Circuit Theory

  • Lim, Jun-Hee;Kim, Sung-Soo
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.187-191
    • /
    • 2016
  • Retrieving the equivalent electromagnetic parameters (permittivity and permeability) plays an important role in the research and application of metamaterials. Frequency dispersion of magnetic permeability has been theoretically predicted in a metamaterial composed of cut wire pairs (CWP) separated by dielectric substrate on the basis of circuit theory. Magnetic resonance resulting from antiparallel currents between the CWP is observed at the frequency of minimum reflection loss (corresponding to absorption peak) and effective resonator size can be determined. Having calculated the circuit parameters (inductance L, capacitance C) and resonance frequency from CWP dimension, the frequency dispersion of permeability of Lorentz like magnetic response can be predicted. The simulated resonance frequency and permeability spectra can be explained well on the basis of the circuit theory of an RLC resonator.

Morphologic Assessment of Corpus Callosum in the Patient of Alzheimer Disease using Magnetic Resonance Imaging

  • Seoung, Youl-Hun;Choe, Bo-Young
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.13 no.2
    • /
    • pp.84-95
    • /
    • 2009
  • The purpose of this study was to evaluate the usefulness of the measurement of corpus callosum (CC) size in the Alzheimer patient by using magnetic resonance (MR) midsagittal image. We performed MR scanning in 20 normal high age group, and in 20 mild cognitive impairment (MCI) group, and in 20 Alzheimer disease (AD) group. The following parameters were employed in AD group: TRITE/FA 6650ms/66ms/$90^{\circ}$, NEX 2, Thickness/Gap 2/0, FOV 220mm. The magnetic field strength was used at 3.0 Tesla. We selected midsagittal image of the brain by using view forum program, measured CC size, which were anteroposterior length, diameter of genu, body, narrowing portion, and splenium. The present study demonstrates that CC size of Alzheimer disease can be useful for clinical assessment concerning the diameter of genu, body, and splenium.