• Title/Summary/Keyword: Magnetic Object

Search Result 219, Processing Time 0.029 seconds

Measuring Methods for Two-dimensional Position Referring to the Target Pattern (참조패턴 기반의 2차원 변위 측정 방법론)

  • Jung, Kwang Suk;Lee, Sang Heon;Park, Sung-Jun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.1
    • /
    • pp.77-84
    • /
    • 2013
  • In this paper, we review two-dimensional measuring methods referring to target patterns. The patterns consist of two linearly-repeated patterns or is designed repeatedly in two-dimension. The repeated properties are reflectivity, refractivity, air-gapping distance, capacitance, magnetic reluctance, electrical resistance and sloping gradient, etc. However, the optical methods are generally used for high speed processing and density, and their encoding principles are treated here. In case of two-dimensional pattern, as there is not inherently error between single units encoding the pattern except for the metrology frame errors, the end-effector position of an object accompanying the pattern can be measured with respect of the global frame without via error. Therefore, it is regarded as a substitute for laser interferometer with severe environmental constraints and has been applied to the high-accurate planar actuator.

Development of Crack Examination Algorithm Using the Linearly Integrated Hall Sensor Array (선형 홀 센서 배열을 사용한 결함 검사 알고리즘 개발)

  • Kim, Jae-Jun;Kim, Byoung-Soo;Lee, Jin-Yi;Lee, Soon-Geul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.30-36
    • /
    • 2010
  • Previous researches show that linearly integrated Hall sensor arrays (LIHaS) can detect cracks in the steel structure fast and effectively This paper proposes an algorithm that estimates the size and shape of cracks for the developed LIHaS. In most nondestructive testing (NDT), just crack existence and location are obtained by processing 1-dimensional data from the sensor that scans the object with relative speed in single direction. The proposed method is composed with two steps. The first step is constructing 2-dimensionally mapped data space by combining the converted position data from the time-based scan data with the position information of sensor arrays those are placed in the vertical direction to the scan direction. The second step is applying designed Laplacian filter and smoothing filter to estimate the size and shape of cracks. The experimental results of express train wheels show that the proposed algorithm is not only more reliable and accurate to detecting cracks but also effective to estimate the size and shape of cracks.

2D Location Estimation of a Magnetized Tip Using Arrayed GMR Sensors (GMR센서 배열을 이용한 자석팁의 2D 위치 추정)

  • Lee, S.C.;Kim, J.K.;Ahn, J.H.;Kim, H.Y.
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.395-401
    • /
    • 2019
  • This paper proposes a method for estimating the location of a magnetized tip that is inside a non-transparent space or body by using arrayed giant magnetoresistance (GMR) sensors. In general, an object located in such an opaque space can be detected using X-rays, magnetic fields, ultra-sonic sensors, etc., depending on its characteristics. X-ray is mostly used for medical purposes but frequent exposure to it could cause harm to patients as well as doctors. In this study, how well a GMR sensor is applicable instead of an X-ray is investigated. The sensor's voltage output is experimentally fitted to distance with a relationship of 3rd degree polynomial. To detect a small magnetized tip with 900 Oe inside a human body, a 2×2 arrayed GMR sensor and a location estimation algorithm based on information acquired from four sensors is developed. Evaluation tests show that the suggested method is applicable to limited cases with a distance less than 33-55 mm, and the location of a magnet tip is estimated relatively well with an error less than 1.5 mm.

Susceptibility Contrast Enhancement Imaging in MRI (핵자기 공명 단층 촬영에서의 자화율 강조 영상법)

  • Ro, Y.M.;Mun, C.W.;Lim, T.H.;Cho, Z.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.85-91
    • /
    • 1992
  • In MRI, an image contrast can be developed as a result of the susceptibility effect if an object has paramagnetic substances. This is mainly due to the non-uniform phase distribution or linear gradient developed by the magnetic susceptibility within a voxel, which in turn reduces the signal intensity; e.g., spin phases are dephased and thereby cancel each other resulting in a reduced signal. In this paper, a new concept for manipulating the susceptibility effect through the use of tailored RF pulses is proposed. As potential applications of the method, two different types of tailored RF pulses are introduced: one for susceptibility artifact correction and the other for contrast enhancement. The latter, for example, can be applied to angiography utilizing the paramagnetic property of deoxygenated blood. Both a theoretical study of the method and experimental results are reported.

  • PDF

Hysteresis Loops of Magnetically Coupled Multilayers - Experiment and Calculations

  • Czapkiewicz, M.;Stobiecki, T.;Rak, R.;Wrona, J.;Kim, C.G.
    • Journal of Magnetics
    • /
    • v.9 no.2
    • /
    • pp.60-64
    • /
    • 2004
  • In this paper calculations of magnetisation and magnetoresistance characteristics of the Spin Valve (SV) and Pseudo Spin Valve (PSV) spintronics structures are reported and compared with the experimental data. The magnetisation reversal process was analysed with respect to the Stoner- Wohlfahrt model of total surface energy in terms of uniaxial anisotropy, exchange coupling between ferromagnetic layers, unidirectional exchange anisotropy of pinned layer (modelled by exchange coupling between magnetisation of pinned layer and net magnetisation of antiferromagnetic layer with high anisotropy). The numerical simulation of the model to the experimental magnetisation data yielded the above parameters for SV and PSV structures. These parameters were used to more sophistically micromagnetic modelling tool originating from the project called Object Oriented Micromagnetic Framework. Influence of the shape anisotropy of the Magnetic Tunnelling Junction cell used in MRAM was simulated by means of micromagnetic simulations. Results were compared to those obtained from the spot Kerr measurements.

DEVELOPMENT OF CFD PROGRAM FOR THE CONJUGATE HEAT TRANSFER ANALYSIS OF PMSM ELECTRIC MOTOR (PMSM 전동기 모터의 복합 열전달 해석을 위한 CFD 프로그램 개발)

  • Lee, Jung-Hee;Choi, Jong-Rak;Hur, Nahm-Keon;Kim, Joo-Han;Kim, Young-Kyoun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.488-493
    • /
    • 2011
  • The object of this study is to develope the program for analyzing the fluid flow and heat transfer of PMSM electric motor. The program will be mainly used for inexperienced users of CFD analysis. So it has to be performed using the geometry data and the heat source of each part only. Interface program for converting the given data to the instruction of pre-processor is developed. The conjugate heat transfer between a flow passage of the motor and inner parts consisting of rotor and stator is regarded. In order to reduce the computational time and memory storage, cyclic boundary condition is applied. For the numerical simulation, MRF(Multi-Reference Frame) method is used to consider rotating operation of the rotor and heat source is applied to the copper, wire, and magnetic parts in the motor. On the screen of computer, the users can show the velocity distributions and the contours such as pressure, turbulent kinetic energy, turbulent dissipation rate and temperature.

  • PDF

Intra-Motion Compensation Using CSRS method in MRI

  • Ro, Y.M.;Yi, J.H.;Cho, Z.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.4
    • /
    • pp.377-382
    • /
    • 1994
  • In the conventional Fourier imaging method in MRI (Magnetic Resonance Imaging), intramotion such as pulsatile flow makes zipper-like artifact along the phase encoding direction. On the other hand, line-integral projection reconstruction (LPR) method has advantages such as imaging of short T2, object and reduction of the flow artifact by elimination of the flow-induced phase fluctuation. The LPR, however, necessarily requires time consuming filtering and back-projection processes, so that the reconstruction takes long time. To overcome the long reconstruction time of the LPR and to obtain the flow artifact reduction effect, we adopted phase corrected concentric square raster sampling (CSRS) method and improved its imaging performance. The CSRS is a fast reconstruction method which has the same properties with the LPR. In this paper, we proposed a new method of flow artifact reduction using the CSRS method. Through computer simulations and experiments, we verified that the proposed method can eliminate phase fluctuations, thereby reducing the flow artifact and re- markably shorten the reconstruction time which required long time in the LPR.

  • PDF

A design of hybrid detection system with long term operating reliability in underwater (장기 동작 신뢰성을 고려한 수중 복합 탐지 시스템 설계)

  • Chung, Hyun-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.198-205
    • /
    • 2005
  • Recently, the systems using multiple sensors such as magnetic, acoustic and pressure sensor are used for detection of underwater objects or vehicles. Those systems have difficulty of maintenance and repair because they operate underwater. Thus, this paper describes a hybrid detection system with long term operating reliability. This has a multi-signal transmission structure to have a high reliability. First, a signal transmission & receiving part, which transfers data from underwater sensors to land and receive control message from land through optical cable, has 4 multi-path. Second, the nodes for signal transmission are connected dually each other with single-hop construction and sensors are connected to a couple of neighboring nodes. This enables the output signal to transmit from a node to the next node and the next but one node together. Also, the signal from a sensor can be transmitted to two nodes at the same time. Therefore, the system with this construction has high reliability in long term operation because it makes possible to transmit sensor data to another node which works normally although a transmission node or cable in system have some faults.

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan

  • Heo, Yeong-Cheol;Lee, Hae-Kag;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.18 no.4
    • /
    • pp.422-427
    • /
    • 2013
  • The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.

Design of a Free Bulge Test Coil Using Electromagnetic Forces and Comparison between Experimental and Numerical Results (전자기력 자유벌지 실험을 위한 성형코일 설계 및 3-D 해석비교)

  • Kim, H.K.;Noh, H.G.;Kang, B.S.;Kim, J.
    • Transactions of Materials Processing
    • /
    • v.23 no.7
    • /
    • pp.431-438
    • /
    • 2014
  • For electromagnetic forming(EMF) the most important feature is a forming coil which creates the electromagnetic force(Lorentz force), using current density and a magnetic field. Most previous papers have concentrated on the final configuration of the blank or the efficiency of EMF process. Studies focused on the design parameters affected by the forming coil performance have not been conducted. In order to design a suitable forming coil for an object, the current study uses LS-DYNA EM-Module to not only optimize the coil but also to examine the effect of coil performance. By this method a suitable forming coil was made and tested to determine whether or not good formability was achieved in a free bulge test Numerical analysis was also used. The workpiece was Al 1100-O with a thickness of 1.27mm and the coil was made from copper CW004A, which has good electrical conductivity and is suitable for electrical components.