Browse > Article
http://dx.doi.org/10.4283/JMAG.2013.18.4.422

Effects of NEX on SNR and Artifacts in Parallel MR Images Acquired using Reference Scan  

Heo, Yeong-Cheol (Department of Radiology, Kyung Hee University Hospital at Gang-dong)
Lee, Hae-Kag (Department of Computer Science and Engineering, Soonchunhyang University)
Cho, Jae-Hwan (Department of International Radiological Science, Hallym University of Graduate Studies)
Publication Information
Abstract
The aim of this study was to investigate effects of the number of acquisitions (NEX) on signal-to-noise (SNR) and artifacts in SENSE parallel imaging of magnetic resonance imaging (MRI). 3.0T MR System, 8 Channel sensitivity encoding (SENSE) head coils were used along with an in-vivo phantom. Reference sequence of 3D fast field echo (FFE) was consisted of NEX values of 2, 4, 6, 8, 10 and 12. The T2 turbo spin echo (TSE) sequence used for exams achieved SENSE factors of 1.2, 1.5, 1.8, 2.0, 2.2, 2.5, 2.8, 3.0, 3.2, 3.5, 3.8 and 4.0. Exams were conducted five times for each SENSE factor to measure signal intensity of the object, the posterior phase-encode direction and frequency direction. And SNR was calculated using mean values. SENSE artifacts were identified as background signal intensity in the phase-encoded direction using MRIcro. It was found that SNR increased but SENSE artifacts reduced with NEX of 4, 8 and 12 when the NEX increased in reference scan. It is therefore concluded that image quality can be improved with NEX of 4, 8 and 12 for reference scanning.
Keywords
reference scan; NEX; SNR; SENSE artifact;
Citations & Related Records
연도 인용수 순위
  • Reference
1 C. B. Ahn, J. H. Kim, and Z. H. Cho, IEEE Trans. Med. Imag 5, 1 (1986).   DOI   ScienceOn
2 B. A. Poser and D. G. Norris, MAGMA 20, 11 (2007).   DOI
3 P. Mansfield, J. Phys. C 10, 155 (1977).
4 C. H. Meyer, B. S. Hu, D. G. Nishimura, and A. Macovski, Magn. Reson. Med 28, 202 (1992).   DOI
5 D. K. Sodickson and W. J. Manning, Magn. Reson. Med. 38, 591 (1997).   DOI   ScienceOn
6 K. P. Pruessmann, M. Weiger, M. B. Scheidegger, and P. Boesiger, Magn. Reson. Med. 42, 952 (1999).   DOI   ScienceOn
7 M. Blaimer, F. Breuer, M. Mueller, R. M. Heidemann, M. A. Griswold, and P. M. Jakob, Top. Magn. Reson. Imag. 15, 223 (2004).   DOI   ScienceOn
8 S. K. Park, C. B. Ahn, D. G. Sim, and H. C. Park, J. Korean Soc. Magn. Reson. Med. 12, 123 (2008).
9 P. G. Batchelor, D. Atkinson, P. Irarrazaval, D. L. Hill, J. Hajnal, and D. Larkman, Magn. Reson. Med. 54, 1273 (2005).   DOI   ScienceOn
10 C. L. Christine, C. R. Jack, R. C. Grimm, P. J. Rossman, J. P. Felmlee, R. L. Ehman, and S. J. Riederer, Magn. Reson. Med. 36, 436 (1996).   DOI
11 S. K. Park, Sensitivity Encoding (SENSE) for Parallel MRI. Master's Thesis, Kwangwoon University (2007).
12 J. F. Glockner, H. H. Hu, D. W. Stanley, L. Angelos, and K. King, Radiographics 25, 1279 (2005).   DOI   ScienceOn
13 M. Weiger, K. P. Pruessmann, and P. Boesiger, Magnetic Resonance in Medicine 43, 177 (2000).   DOI
14 D. K. Sodickson and W. J. Manning, Magnetic Resonance in Medicine 38, 591 (1999).
15 J. Hennig, A. Naureth, and H. Friedburg, Magn. Reson. Imag 3, 823 (1986).   DOI   ScienceOn
16 K. P. Pruessmann, M. Weiger, P. Bornert, and P. Boesiger, Magnetic Resonance in Medicine 46, 638 (2001).   DOI   ScienceOn
17 M. H. Park, J. W. Lee, K. W. Lee, C. W. Ryu, and G. H. Jahng, J. Korean. Soc. Magn. Reson. Med. 13, 161 (2009).