• Title/Summary/Keyword: Machinery noise

Search Result 564, Processing Time 0.025 seconds

Order Tracking without a Tacho Signal - A new Method and Its Applicability for Rotating Machinery Diagnostics

  • Pedersen, Thorkiid Find;Konstantin-Hansenf, Hans
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.271-274
    • /
    • 2005
  • For noise and vibration order-analysis on rotating machinery, it is compulsory to measure the RPM of the rotating part of the machine. Normally the RPM is measured using dedicated tacho-probes. In this paper we describe a new method that in real-time synthesizes a tacho signal from the measured noise or vibration signal thus eliminating the tacho probe. The method strengths and weaknesses are evaluated on practical signals.

  • PDF

A Study on the Floor Impact Noise Analysis (바닥충격음 해석에 관한 연구)

  • Kim Hyun-Sil;Kim Jae-Seung;Kang Hyun-Joo;Kim Bong-Ki;Kim Sang-Ryul
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.461-468
    • /
    • 2002
  • Prediction method of floor impact noise for light and heavy weight impact is described. Sound pressure level is predicted based on the impedance method. For floating floor system, noise reduction is studied assuming 1-D mass-spring system. It is found that comparisons of predictions and measurements show good agreements. However, certain correction factor is needed to predict noise reduction of floating floor system.

  • PDF

Trouble Shooting of Environment Noise Problem for Apartment and Residence Place adjacent to Underground Machinery Room (지하기계실에서 발생한 아파트 및 인접거주지역의 소음 발생 원인 분석 및 해결 사례)

  • 김현식;손성완;김한준
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.903-909
    • /
    • 2001
  • Apartment and large residence buildings are necessary to ensure a comfortable noise/vibration environment. So. it must be performed a anti-vibration/noise evaluation at early design stage, such as utility room arrangement, machinery installation method and so on. In this paper. environment noise status on problem areas, which was issued by resident. was investigated to understand the noise transmission property generated from underground machinery room and to device a optimized countermeasure in order to enhance noise environment. Also, the measured noise levels before and after modification works are compared to confirm the effectiveness of proposed countermeasure.

  • PDF

Impact of Sound Insulation in a Combine Cabin

  • Kim, Chiho;Jung, Ho Jun;Jo, Jin Seok;Kim, Myong il;Lee, Bongho;Park, Tae Jong;Seo, Kwangwook;Kim, Hyeon Tae
    • Journal of Biosystems Engineering
    • /
    • v.40 no.3
    • /
    • pp.159-164
    • /
    • 2015
  • Purpose: Recently, environmental pollution and safety problems in agricultural production have become important issues. Initially, bio-production machines focused on high production efficiency rather than workers' safety and comfort, but this trend slowly has changed as time went on. Methods: This study was carried out to identify sound efficiently and reliably for noise reduction by using a combine cabin model. Ethylene propylene diene monomer (M-class) rubber (EPDM) was applied to improve noise reduction performance from parts connected directly to the front, rear, left side, and bottom side of the cabin. Results: As a result, an average noise reduction of 1.85 dB was achieved in the normal hearing range between 500 Hz to 2 kHz. Conclusions: Reducing the cabin noise levels can reduce a worker's fatigue, improve working environment, and contribute to future low-noise and high-quality cabin environment.

A Study on Noise and Vibration Reduction Measurements of a Floating Floor Structure by means of a Ship Cabin Mock-up (선박 격실 mock-Up을 이용한 뜬바닥구조의 소음.진동 저감효과 계측에 관한 연구)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Kang, Hyun-Ju;Kim, Bong-Ki;Kim, Sang-Ryul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.719-725
    • /
    • 2008
  • In this paper, noise and vibration reduction for floating-floored ship cabin is studied. A mock-up is built by using 6 mm steel plate, and two identical cabins are made for simulation of ship cabins. When a speaker is used as a sound and vibration sources, it is shown that floating floor is more effective in isolating sound than bare deck by 2-5 dB. It is also shown that structure-borne noise of the bare deck is greater than that of floating-floored deck by 3-10 dB. For tapping machine excitation, it is found that the effect of floating floor in airborne noise and structure-borne noise reduction reaches up to 40-50 dB for high frequency ranges.

Analysis of performance test results of CA-certified air cleaners from 2003 to 2015 (2003년부터 2015년까지 CA 인증 공기청정기의 성능 시험 결과 분석)

  • Kim, Hak-Joon;Hong, Kee-Jung;Woo, Chang Gyu;Han, Bangwoo;Kim, Yong-Jin
    • Particle and aerosol research
    • /
    • v.13 no.1
    • /
    • pp.17-23
    • /
    • 2017
  • In this study, the test results obtained from the performance tests for CA (Korea Association of Cleaning Air) certificated air cleaners which had been commercially available in Korea from 2003 to 2015 were analyzed. Among the test parameters such as flow rate, particle collection efficiency, clean air delivery rate (CADR), ozone emission, odor removal efficiency and noise level, noise level and CADR were correlated with flow rates. Collection and odor removal efficiencies were 20% higher than the limit of the CA certification. The ozone emissions from the air cleaners were negligible because all the air cleaners were equipped with only HEPA filters, not electrostatic precipitation method which produces ozone.

A Noise Control of the Incineration Plant and the Pump (소각장과 펌프의 이상소음 제어)

  • 주원호;박진화;배종국;정균양
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1998.04a
    • /
    • pp.741-746
    • /
    • 1998
  • A severe noise in industrial field can be sometimes generated from unexpected installation error and misunderstanding of industrial machinery. To solve the noise problem, the diagnostic tool is generally applied to identify the noise source and to detect the fault of machinery. And then, the suitable control countermeasure corresponding to the diagnostic results is presented. In this paper, two control cases an noise problem of the Incineration Plant and the Pump are introduced.

  • PDF

Development of Case-based Reasoning System for Abnormal Vibration Diagnosis of Rotating Machinery (회전기계의 이상진동진단을 위한 사례기반 추론 시스템의 개발)

  • Lee, C.M.;Yang, B.S.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1046-1050
    • /
    • 2000
  • The necessity of diagnosis of the rotating machinery which is widely used in the industry is increasing. If rotating machinery has fault, we can detect fault using vibration or noise. But, in diagnosing rotating machinery, the end user who doesn't have expert knowledge needs the help of vibration diagnosis expert. However, vibration diagnosis experts who well satisfy the demand of end user are rare. So, this paper propose a development of the case-based reasoning system for abnormal vibration diagnosis of rotating machinery we construct the past experiences of vibration diagnosis expert into case base and shear the experiences of diagnosis expert with the end user. In this paper, we describe that process of structured system and adapting result of abnormal vibration diagnosis of electric motor.

  • PDF

Evaluation of Sound Insulation Performance of a Unit Cabin Mock-up (유니트 캐빈 목업(mock-up)의 차음성능평가)

  • Kim, Hyun-Sil;Kim, Sang-Ryul;Kim, Bong-Ki;Kim, Jae-Seung;Lee, Sung-Hyun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.1
    • /
    • pp.49-55
    • /
    • 2011
  • Sound insulation performance of a unit cabin mock-up is studied, where two identical rooms simulating cruise ship cabin are installed. STL (Sound Transmission Loss) measurement in the mock-up shows that STL of the partition between rooms is degraded by imperfect door ceiling and gap between wall and floor. It is also observed that gap around lighting and electrical outlet slightly affect the STL in high frequency ranges, since lighting and electrical outlet are supported by mineral wool in the back side due to fire-resistance requirement. Even after all possible gaps are sealed, STL of the partition is found to be lower than that measured in the laboratory by 9 dB. Measurement of SBN (Structure-Borne Noise) reveals that flanking transmission of SBN along the steel deck floor can severely deteriorate STL of the partition. Statistical energy analysis (SEA) of the mock-up confirms importance of the floor SBN control, in which increasing damping is essential to ensure high STL.