• Title/Summary/Keyword: M_CAM

Search Result 354, Processing Time 0.022 seconds

A Study on the Development of High Precision Cam Profile Measuring System using Laser Interferometer (레이저를 이용한 캠 프로파일 정밀 측정 장치 개발에 관한 연구)

  • Lim S.H.;Lee C.M.;Jung J.Y.;Yoon S.D.;Shin S.H.;Shin S.W.;Hwang Y.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.267-268
    • /
    • 2006
  • Cam mechanisms are one of the most popular devices for generating irregular motion and are widely used in many industrial areas. The purpose of this study is the development of high precision measuring system fur measurement data acquisition and analysis of a manufactured cam profile. The developed system is composed of servo motor, CNC controller, rotary encoder, and laser interferometer And also, this system is non-contact measuring type. The developed system takes only 5 minutes to measure a cam profile and to analyze the measuring data while the CMM(coordinate measuring machine) takes about 1 hours even by a skilled operator.

  • PDF

Internal evaluation of provisional restorations according to the dental CAD/CAM manufacturing method : Three-dimensional superimpositional analysis (치과 CAD/CAM 가공방식에 따른 임시보철물의 내면 적합도 : 3차원 중첩 분석)

  • Kim, Jae-Hong;Kim, Ki-Baek
    • Journal of Technologic Dentistry
    • /
    • v.41 no.2
    • /
    • pp.81-86
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the internal fit of two different temporary restorations fabricated by dental CAD/CAM system and to evaluate clinical effectiveness. Methods: Composite resin tooth of the maxillary first molar was prepared as occlusal reduction(2.0mm), axial reduction(1mm offset), vertical angle(6 degree) and chamfer margin for a temporary crown and duplicated epoxy die was fabricated. The epoxy dies were used to fabricate provisional restorations by CAD/CAM milling technique or 3D-printing technique. The inner data from all crowns were superimposed on the master die file in the 'best-fit alignment' method using 3D analysis software. Statistical analysis was performed using a Wilcoxon's rank sum test for differences between groups. Results: It showed that the internal RMS(Root Mean Square) values of the additive group were significantly larger than those of other group. No significant differences in internal discrepancies were observed in the temporary crowns among the 2 groups with different manufacturing method. Conclusion: All the groups had the internal fit within the clinical acceptable range (< $50{\mu}m$). The continuous research in the future to be applied clinically for the adaptation of additive manufacturing technique are needed.

Evaluation of marginal and internal gap of wax coping fabricated by CAD/CAM system using intraoral scanner (구강 내 스캐너를 사용하여 CAD/CAM으로 제작된 왁스 코핑의 적합도 평가)

  • Kim, Dong-Yeon;Jung, Il-Do;Lee, Jae-Jun;Kim, Ji-Hwan;Kim, Myung-Bae;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2015
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of wax copings fabricated from extraoral scanning with intraoral scanning. Methods: Fifteen study models(abutment of teeth 16) were made by PMMA. STL files of thirty abutment were prepared by intraoral scanning with extraoral scanning. Wax copings of thirty fabricated using CAD/CAM system. Marginal and internal gap of wax copings of thirty were measured by silicone replica technique and digital microscope(${\times}140$). Date were analyzed by using independent samples t-test. Results: Mean (SD) of two group were measured $55.61(27.42){\mu}m$ for totally gap of ES group and $60.67(33.14){\mu}m$ for totally gap of IS group. But marginal and internal gap of two group were not differences statistically significant(p>0.05). Conclusion: Evaluation of marginal and internal gap of two group showed that no differences statistically significant and clinically acceptable results.

Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system

  • Lee, Wan-Sun;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.265-270
    • /
    • 2017
  • PURPOSE. This study is to evaluate the internal fit of the crown manufactured by CAD/CAM milling method and 3D printing method. MATERIALS AND METHODS. The master model was fabricated with stainless steel by using CNC machine and the work model was created from the vinyl-polysiloxane impression. After scanning the working model, the design software is used to design the crown. The saved STL file is used on the CAD/CAM milling method and two types of 3D printing method to produce 10 interim crowns per group. Internal discrepancy measurement uses the silicon replica method and the measured data are analyzed with One-way ANOVA to verify the statistic significance. RESULTS. The discrepancy means (standard deviation) of the 3 groups are $171.6\;(97.4){\mu}m$ for the crown manufactured by the milling system and 149.1 (65.9) and $91.1\;(36.4){\mu}m$, respectively, for the crowns manufactured with the two types of 3D printing system. There was a statistically significant difference and the 3D printing system group showed more outstanding value than the milling system group. CONCLUSION. The marginal and internal fit of the interim restoration has more outstanding 3D printing method than the CAD/CAM milling method. Therefore, the 3D printing method is considered as applicable for not only the interim restoration production, but also in the dental prosthesis production with a higher level of completion.

A Design of the IP Lookup Architecture for High-Speed Internet Router (고속의 인터넷 라우터를 위한 IP 룩업구조 설계)

  • 서해준;안희일;조태원
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.7B
    • /
    • pp.647-659
    • /
    • 2003
  • LPM(Longest Prefix Matching)searching in If address lookup is a major bottleneck of IP packet processing in the high speed router. In the conventional lookup table for the LPM searching in CAM(Content Addressable Memory) the complexity of fast update take 0(1). In this paper, we designed pipeline architecture for fast update of 0(1) cycle of lookup table and high throughput and low area complexity on LPM searching. Lookup-table architecture was designed by CAM(Content Addressable Memory)away that uses 1bit RAM(Random Access Memory)cell. It has three pipeline stages. Its LPM searching rate is affected by both the number of key field blocks in stage 1 and stage 2, and distribution of matching Point. The RTL(Register Transistor Level) design is carried out using Verilog-HDL. The functional verification is thoroughly done at the gate level using 0.35${\mu}{\textrm}{m}$ CMOS SEC standard cell library.

Marginal and Internal Fit of Copings Made by CAD/CAM using Different Scanning Methods (서로 다른 스캔 방식을 이용하여 CAD/CAM에 의해 제작된 코핑의 변연 및 내면의 적합성)

  • Cho, Young Beom;Chae, Heon Chung;Kim, Hee Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.366-376
    • /
    • 2013
  • The purpose of this study is to evaluate the marginal and internal fit of coping made by CAD/CAM using different scanning methods. Zirconia coping was made by each CAD/CAM system followed by intra-oral scanning, model optical scanning and model contact scanning. It was embedded into Epoxy Resin and was cut by buccal to lingual. AMD (Absolute marginal discrepancy), MG (Marginal gap), GA (Gap of axial), GL (Gap of line angle) and GO (Gap of occlusal) of each sample were measured. The result is as followed; 1. The mean value of AMD in Group 1, Group 2, Group 3 are $141.21{\pm}42.94{\mu}m$, $140.63{\pm}31.64{\mu}m$, $109.37{\pm}28.42{\mu}m$. The averages of MG in Group 1, Group 2, Group 3 are $82.52{\pm}43.99{\mu}m$, $90.28{\pm}27.93{\mu}m$, $66.55{\pm}28.77{\mu}m$. Statistically there is no difference in AMD and MG among the three Groups (Anova, P>0.05). 2. GA of Group 2 revealed statistically difference compared with Group 1 and Group 3 (Anova, P<0.05). 3. GL and GO of Group 1 showed statistically significant differences compared with Group 2 and Group 3 (Mann-whitney test (P<0.05). Zirconia copings made by 3 ways of scanning methods have no difference with conventional ceramics in AMD and MG which are known as the most important factors.

The effect of glazing and aging on the surface properties of CAD/CAM resin blocks

  • Tekce, Neslihan;Fidan, Sinan;Tuncer, Safa;Kara, Dilan;Demirci, Mustafa
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.50-57
    • /
    • 2018
  • PURPOSE. To investigate the effect of accelerated aging on surface properties of glazed CAD/CAM resin blocks using a 2D surface profilometer and a 3D non-contact optical profilometer. MATERIALS AND METHODS. Three types of CAD/CAM resin restorative materials, LAVA Ultimate (3M ESPE, St Paul, MN, USA), VITA Enamic (Vita Zahnfabrik H. Rauter, Bad $S\ddot{a}ckingen$, Germany), and Cerasmart (GC Corparation, Tokyo, Japan) were used for this study. CAD/CAM blocks were cut in 3-mm thickness slabs and divided into three groups; Group 1: control group (specimens polished with 600 grit SCI paper); Group 2: specimens sandblasted, silanized, and glazed with Optiglaze Color (GC); Group 3: glazed specimens subjected to 5000 thermocycles (n=15). The surface roughness ($R_a$ and $R_z$) was evaluated using a profilometer and a 3D scanning instrument. Data were analyzed using two-way ANOVA and Tukey's post- hoc test (P<.05). RESULTS. LAVA, VITA, and Cerasmart exhibited statistically similar $R_a$ and $R_z$ values for each group (P>.05). For VITA and Cerasmart, the specimens in Group 1 exhibited significantly higher $R_a$ values than Group 2 (P<.05). Group 1 ($0.502R_a$), Group 2 ($0.384R_a$), and Group 3 ($0.431R_a$) exhibited statistically similar $R_a$ values for LAVA (P=.062). After 5000 thermocycles, surface roughness values did not change significantly for glazed LAVA, VITA, and Cerasmart (P>.05). CONCLUSION. Glaze material Optiglaze Color makes CAD/CAM resin surfaces smooth and glazed CAD/CAM surfaces seem resistant to deterioration under 5000 thermocycles.

Preflight Calibration Results of Wide-Angle Polarimetric Camera (PolCam) onboard Korean Lunar Orbiter, Danuri

  • Minsup Jeong;Young-Jun Choi;Kyung-In Kang;Bongkon Moon;Bonju Gu;Sungsoo S. Kim;Chae Kyung Sim;Dukhang Lee;Yuriy G. Shkuratov;Gorden Videen;Vadym Kaydash
    • Journal of The Korean Astronomical Society
    • /
    • v.56 no.2
    • /
    • pp.293-299
    • /
    • 2023
  • The Wide-Angle Polarimetric Camera (PolCam) is installed on the Korea's lunar orbiter, Danuri, which launched on August 5, 2022. The mission objectives of PolCam are to construct photometric maps at a wavelength of 336 nm and polarization maps at 461 and 748 nm, with a phase angle range of 0°-135° and a spatial resolution of less than 100 m. PolCam is an imager using the push-broom method and has two cameras, Cam 1 and Cam 2, with a viewing angle of 45° to the right and left of the spacecraft's direction of orbit. We conducted performance tests in a laboratory setting before installing PolCam's flight model on the spacecraft. We analyzed the CCD's dark current, flat-field frame, spot size, and light flux. The dark current was obtained during thermal / vacuum test with various temperatures and the flat-field frame data was also obtained with an integrating sphere and tungsten light bulb. We describe the calibration method and results in this study.

In Vitro Anticomplementary Activity of Phenylpropanoids from Agastache rugosa

  • Oh, Sei-Ryang;Jung, Keun Young;Lee, Hyeong-Kyu
    • Korean Journal of Pharmacognosy
    • /
    • v.27 no.1
    • /
    • pp.20-25
    • /
    • 1996
  • In searching for anticomplementary compounds, three phenylpropanoids were isolated from the roots of Agastache rugosa and identified as rosmarinic acid (RA), rosmarinic acid methyl ester (RAM) and caffeic acid methyl ester (CAM) by NMR analyses. RA and RAM exhibited strong inhibitory activity on both the classical pathway (CP) and the alternative pathway (AP) of the complement system, in vitro, but CAM did far less than RA and RAM. $RAM-M1{\sim}-M5$, the methylated derivatives from the RAM, showed that the inhibitory activity was decreased in inverse proportion to the number of methylated groups and $RAM-M 2{\sim}-M4$, the isomers of two methylated hydroxyl groups, exhibited different inhibition activity.

  • PDF

Estimation of Hydraulic Conductivity Using Piezocone Penetration Test (피에조콘 관입 시험을 이용한 투수계수 산정기법 연구)

  • 송정락
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.2
    • /
    • pp.31-39
    • /
    • 2001
  • 본 연구에서는 수정 Cam Clay 모델과 혼합체 커플링 이론(coupled theory of mixtures)을 이용하여 피에조콘 관입시험을 해석하여 지반의 투수계수와 과잉간극수압의 정량적 관계를 고찰하였다. 본 연구의 이론적 해석 결과는 시험결과들과 비교하였으며 그 결과 피에조콘 관립 시험시 관측된 과잉간극수압은 지반의 투수계수가 $10^{-9}$m/sec에서 $10^{-6}$m/sec의 범위에서는 투수계수에 따라 피에조콘 관립 시험시 관측된 과잉간극수압이 현저하게 변하는 것으로 나타나 피에조콘 관입시험시 관측한 과잉간극수압을 이용하여 지반의 투수계수를 결정할 수 있음을 알 수 있었다. 또한 지반의 투수계수가 $10^{-9}$m/sec 이하에서는 지반이 거의 완전 비배수 상태에 가까운 거동을 나타내면, 투수계수가 $10^{-6}$m/sec 이상에서는 거의 완전 배수상태에 가까운 거동을 하는 것으로 나타났다.으로 나타났다.

  • PDF