• 제목/요약/키워드: MS solution

검색결과 508건 처리시간 0.024초

ICP-MS와 AAS를 이용한 대기 입자상 표준물질 (SRM 1648) 금속성분의 정량에 관한 연구 (Determination of Metallic Elements in Urban Particulate Matter (SRM 1648) by ICP-MS and AAS)

  • 유수영;최금찬;김기현
    • 한국대기환경학회지
    • /
    • 제21권4호
    • /
    • pp.423-430
    • /
    • 2005
  • This study was investigated with sample digestion techniques and a reliability of the analytical results for a quantitative analysis of a standard reference material ('urban particulate matter', SRM 1648). The metallic elements were analyzed by inductively coupled plasma mass spectrometry (ICP-MS) with closed vessel microwave acid digestion method and atomic absorption spectroscopy (AAS). Quality control of the overall analytical procedures for metallic element determinations of standard reference material were estimated by analysis of a SRM 1648. Three digestion solutions $(type\;1:\;HNO_3,\;type\;2:\;HNO_3\;and\;H2O_2(4'1)\;mixture,\;type\;3:5.55\%\; HNO_3\;and\;16.75\%\;HCI\;mixture)$ were applied to SRM 1648. As a result, three digestion solutions used in this study are completely unable to digest Cr of SRM 1648. Reliability of Cr and As showed some errors in the digestion with digestion solution type (3) due to the influence of chlorides. Type (3) digestion solutions are sufficient to fulfill the digestion of As as well as Se in SRM 1648. ICP-MS results showed the improvement in accurate and precise determination of some trace elements like Cd, V and Pb in SRM 1648. It is important to use the proper digestion solution for each element to qualify analytical precision.

Building Calibration Curve for Py-GC/MS Analysis of SBR/BR Blend Rubber Compounds

  • Chae, Eunji;Choi, Sung-Seen
    • Elastomers and Composites
    • /
    • 제55권4호
    • /
    • pp.281-288
    • /
    • 2020
  • A calibration curve is needed to determine the SBR and BR blend ratio of SBR/BR blend rubber compounds using pyrolysis-gas chromatography/mass chromatography (Py-GC/MS) or Py-GC. In general, a calibration curve is obtained using reference SBR/BR vulcanizates with various blend ratios. In this study, the calibration curves were obtained using reference samples made of rubber solutions and were compared to those plotted using the reference SBR/BR vulcanizates. Calibration curves using variations of 1,3-butadiene/styrene, 4-vinylcyclohexene (VCH)/styrene, 2-phenylpropene (PhP)/butadiene, PhP/VCH, 4-phenylcyclohexene (PhCH)/butadiene, and PhCH/VCH ratios with the BR content were examined for the suitability. We found that the calibration curves obtained using the mixed rubber solution references (1,3-butadiene/styrene and PhP/butadiene) could replace those constructed using the reference SBR/BR vulcanizates. The calibration curves of 1,3-butadiene/styrene and PhP/butadiene obtained using the raw references can be used for the determination of the SBR/BR blend ratios by applying some correction factors.

유채유로 만든 견정련비누의 정련 (Studies on the Scouring Effects of Scouring Soap Made from Rapeseed Oil)

  • 배도규;배현석
    • 한국잠사곤충학회지
    • /
    • 제35권1호
    • /
    • pp.43-47
    • /
    • 1993
  • 유채유를 이용해서 만든 새로운 정련비누와 현재 시중에서 사용되고 있는 정련 비누로, 정련염색 및 물성시험을 통하여 얻어진 결과를 비교 분석하여 요약하면 다음과 같다. 1. 정련율에서는 OC(올레인산으로 만든 비누)를 사용한 것이 가장 좋고 RS(유채유로 만든 비누)를 사용한 것이 다음으로 모두 MS(시중에서 사용되고 있는 비누)를 사용한 것보다 우수하였다. 2. 완충력을 측정한 결과 RS와 OS는 비슷하였지만 MS는 크게 떨어졌다. 3. 오염성에 미치는 영향으로는 OS와 RS로 정련한 것이 반점이 없었으나, MS로 정련한 것은 염반이 발생하였다. 4. 강·신도에서는 큰 차이가 없었으나, MS로 정련한 것이 OS, RS로 정련한 것보다 다소 낮았다. 5. 정련 후의 방추도 및 백도는 OS, RS, MS순으로 높게 나타났다.

  • PDF

Corrosion Inhibition of Steel Rebar in Concrete with the Coated MCI 2022

  • Bezad Bavarian;Lisa Reiner;Kim, Chong Y.
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.63-67
    • /
    • 2002
  • The induced chemical and salt solution in water or admixture are originated to the corrosion process of the steeo rebar. These liquids penetrate into concrete as the accompanied by the chemical reaction and cause to attack the steel rebar in concrete. Concrete surfaces which it exposed to deicing, water and sea water is allowed to enter the chlorides in the structures. To prevent from the source of corrosion and deterioration Is subjected to put an end to corrode or reduce to contaminate on the steel rebar. As this reason the MCI 2022 products are applied to the surface of concrete and steel rebar. The concrete samples were made of to the kind of four, i.e. RF, MR, MS, and MM. Corrosion inhibitor is applied to coat on the surface of concrete after it had been cured for 28days. Specimen were immersed in a 3.5% sodium chloride solution. Concrete specimen were tested to determine the changes of the resistance polarization, Rp, over a 22 weeks period. MCI 2022 is significantly shown the corrosion inhibition of steel rebar in 3.5% NaCl solution. In the each different concrete sample, MS and MM is seemed to be better than others. The results are proofed that MCI 2022 is promised to maintain the inhibition of corrosion with high resistance polarization of the steel rebar in concrete.

  • PDF

담배 CMS line의 원형질체로부터 cytoplast의 유도 및 이와 타품종 원형질체와의 융합에 관한 연구 (Studies on the Induction of Cytoplasts from the Protoplasts of CMS(Cytoplasmic Male Sterility) Line of Nicotiana and the Fusion of the Cytoplast and the another Protoplasts)

  • 소상섭;여읍동
    • KSBB Journal
    • /
    • 제8권2호
    • /
    • pp.97-103
    • /
    • 1993
  • 세포질 유전형질의 도입을 성공적으로 수행코자 세질 웅성 불임(eMS; cytoplasmic male sterili­t ty) 계통의 담배 MS(male sterility) Burley 21의 callus tissue에서 cytoplast를 분리시키고 이와 Ni­c cotiana tabacum Burley 64의 mesophyll protoplast 를 PEG방법에 의한 세포융합으로 cybrid cell올 유도할 수 있었다. cytoplast의 분라는 density gradient solution의 osmolarity를 일정하게 하는 것보다 gradient간의 차이가 더 효과적이였으며 분리된 cytoplast의 양은 재료로 이용된 protoplast의 20-30% 정도를 나타 내었다. 또한 cytoplast와 protoplast의 융합은 P PEG농도 50%에셔 효과적이었다.

  • PDF

네트워크 기반 자동화 변전소에서 SOAP을 이용한 IED간 정보교환기술 연구 (A Study on the Information Exchange Technology Between IEDs Using SOAP in Network Based Substation Automation System)

  • 고윤석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권9호
    • /
    • pp.376-383
    • /
    • 2006
  • In this paper, autonomous information exchange methodology is studied between IEDs using SOAP protocol based on XML and PtP communication to archive the safety and reliability of large-scale system operation. The SOAP protocol has the advantages in the independency Problem for operating systems, using language, platforms and the security problem because it is XML-based RPC protocol. Inference-based solution of the IED is designed as rule-based solution so that the IED internal status, the system status or the faulted zone can be inferred autonomously using the internal data as well as information data obtained from free information exchange among other IEDS, Also, it is designed so that the inference results and the operation information are transmitted to the above SCADA system, and determined autonomously whether the commands from the SCADA are executed or not. Finally, The inference-based solution of IED and information exchange system among IEDS is implemented using MS Visual C++ MFC, MS SOAP and MS XML. Availability and accuracy of the proposed methodology and the design is verified from diversity simulation reviews for typical distribution substation.

Determination of Bi Impurity in Lead Stock Standard Solutions by Hydride-generation Inductively Coupled Plasma Mass Spectrometry

  • Park, Chang J.
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권2호
    • /
    • pp.233-236
    • /
    • 2004
  • Total impurity analysis of a primary standard solution is one of the essential procedures to determine an accurate concentration of the standard solution by the gravimetry. Bi impurity is determined in Pb standard solutions by inductively coupled plasma mass spectrometry (ICP-MS). The direct nebulization of the Pb standard solution produces a significant amount of the Pb matrix-induced molecular ions which give rise to a serious spectral interference to the Bi determination. In order to avoid the spectral interference from the interferent $^{208}PbH^+$, the hydride generation method is employed for the matrix separation. The Bi hydride vapor is generated by reaction of the sample solution with 1% sodium borohydride solution. The vapor is then directed by argon carrier gas into the ICP after separation from the mixture solution in a liquid-gas separator made of a polytetrafluoroethylene membrane tube. The presence of 1000 ${\mu}$g/mL Pb matrix caused reduction of the bismuthine generation efficiency by about 40%. The standard addition method is used to overcome the chemical interference from the Pb matrix. Optimum conditions are investigated for the hydride-generation ICPMS. The detection limit of this method is 0.5 pg/mL for the sample solutions containing 1000 ${\mu}$g/mL Pb matrix.

Simultaneous Analysis of the Coloring Compounds in Indigo, Phellodendron bark, and Madder Dye Using HPLC-DAD-MS

  • Ahn, Cheunsoon;Zeng, Xia;Obendorf, S. Kay
    • 한국의류학회지
    • /
    • 제37권6호
    • /
    • pp.827-836
    • /
    • 2013
  • Indigotin, indirubin, berberine, palmatine, alizarin, and purpurin are major pigments of indigo plant, Phellodendron bark, and madder. The six pigments were examined using the HPLC-DAD-MS instrument for the purpose of the simultaneous detection of the pigments in a single sample run. The HPLC-DAD-MS method examined the individual pigment solutions in DMSO, a solution containing 6 pigments, and the DMSO extract of the silk dyed with a dye solution of 5 pigments excluding indirubin. The retention times of the HPLC chromatograms, ${\lambda}_{max}$ of the uv-vis absorption bands in the DAD analyses, and the molecular ions detected for the compound peaks in the MSD analyses were consistent throughout the analyses of individual pigment solutions, mixed pigment solutions, and dye extracted from silk dyeing. The developed instrumental method of the simultaneous detection of six pigments can identify dye in an exhumed textile if the textile is dyed using any one (or multiple) pigments of indigo, Phellodendron bark, or madder plant.

Analytical Determination of Vitamin B12 Content in Infant and Toddler Milk Formulas by Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS)

  • Lee, Jung-Hoon;Shin, Jin-Ho;Park, Jung-Min;Kim, Ha-Jung;Ahn, Jang-Hyuk;Kwak, Byung-Man;Kim, Jin-Man
    • 한국축산식품학회지
    • /
    • 제35권6호
    • /
    • pp.765-771
    • /
    • 2015
  • The development of a sample preparation method and optimization of the analytical instrumentation conditions were performed for the determination of the vitamin B12 content in emulsified baby foods sold on the Korea market. After removal of the milk protein and fats by chloroform extraction and centrifugation, the vitamin B12 was water extracted from the sample. Following filtration of the solution through a nylon filter, the water-soluble extract was purified by solid-phase extraction using a Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS). The solution eluted from the cartridge was dried under a stream of nitrogen gas and reconstituted with 1 mL of water. The sample solution was injected into an LC-MS/MS system after optimizing the mobile phase for vitamin B12 detection. The calibration curve showed good linearity with the coefficient of correlation (r2) value of 0.9999. The limit of detection was 0.03 µg/L and the limit of quantitation was 0.1 µg/L. The method of detection limit was 0.02 µg/kg. The vitamin B12 recovery from a spiking test was 99.62% for infant formula and 99.46% for cereal-based baby food. The sample preparation method developed in this study would be appropriate for the rapid determination of the vitamin B12 content in infant formula and baby foods with emulsified milk characteristics. The ability to obtain stable results more quickly and efficiently would also allow governments to exercise a more extensive quality control inspection and monitoring of products expected to contain vitamin B12. This method could be implemented in laboratories that require time and labor saving.

Analysis of Amyloid Beta 1-16 (Aβ16) Monomer and Dimer Using Electrospray Ionization Mass Spectrometry with Collision-Induced Dissociation

  • Kim, Kyoung Min;Kim, Ho-Tae
    • Mass Spectrometry Letters
    • /
    • 제13권4호
    • /
    • pp.177-183
    • /
    • 2022
  • The monomer and dimer structures of the amyloid fragment Aβ(1-16) sequence formed in H2O were investigated using electrospray ionization mass spectrometry (MS) and tandem MS (MS/MS). Aβ16 monomers and dimers were indicated by signals representing multiple proton adduct forms, [monomer+zH]n+ (=Mz+, z = charge state) and [dimer+zH]z+ (=Dz+), in the MS spectrum. Fragment ions of monomers and dimers were observed using collision-induced dissociation MS/MS. Peptide bond dissociation was mostly observed in the D1-D7 and V11-K16 regions of the MS/MS spectra for the monomer (or dimer), regardless of the monomer (or dimer) charge state. Both covalent and non-covalent bond dissociation processes were indicated by the MS/MS results for the dimers. During the non-covalent bond dissociation process, the D3+ dimer complex was separated into two components: the M1+ and M2+ subunits. During the covalent bond dissociation of the D3+ dimer complex, the b and y fragment ions attached to the monomer, (M+b10-15)z+ and (M+y9-15)z+, were thought to originate from the dissociation of the M2+ monomer component of the (M1++M2+) complex. Two different D3+ complex geometries exist; two distinguished interaction geometries resulting from interactions between the M1+ monomer and two different regions of M2+ (the N-terminus and C-terminus) are proposed. Intricate fragmentation patterns were observed in the MS/MS spectrum of the D5+ complex. The complicated nature of the MS/MS spectrum is attributable to the coexistence of two D5+ configurations, (M1++M4+) and (M2+M3+), in the Aβ16 solution.