• Title/Summary/Keyword: MS analysis

Search Result 3,887, Processing Time 0.028 seconds

Uncertainty evaluation of the analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in hair by GC-NCI-MS/MS (GC-NCI-MS/MS를 이용한 모발 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Lee, Jae-Il;Cheong, Jae-Chul;Suh, Yong-Jun;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH), the metabolite of ${\Delta}^9$-tetrahydrocannabinol, in hair samples by using the bead-assisted liquid-liquid extraction and gas chromatography-tandem mass spectrometric (GC-NCI-MS/MS) detection. Traceability of measurement was established through the use of reference materials, calibrated volumetric tubes, volume measuring devices, and measuring instruments. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day variation was performed by using statistical analysis of several indicative factors. Measurement uncertainty associated with the analyte in real forensic hair samples were estimated using QC data. The major factor of contribution to combined standard uncertainty was inter-day repeatability, while those associated with preparation of analytical standard and also sample of weight were insignificant considering the degree of contribution. Relative uncertainty of relative extended standard uncertainty divided into the measured concentration of the analyte was 17% in a hair sample. The uncertainty of result evaluation will be invaluable to improve quality of the analysis.

Analysis of Plant Hormones using GC-MS (GC-MS를 이용한 식물홀몬 분석)

  • 조광연
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.34 no.s01
    • /
    • pp.26-32
    • /
    • 1989
  • The analytic principles of GC and MS were explained in relation to plant hormone analyses and the characteristics of two instruments were compared. The selection of column, condition of measurement and the method of ionization to get a good spectrum were also briefly described. Finally, the pre-treatment of sample by solvent extraction method to remove the unnecessary part of sample and the synthetic method, especially reagents and reaction condition, for the preparation of ether or ester derivative which can be easily vaporized in GC were explained.

  • PDF

Development of Rapid Analysis Method for Pesticide Residues by GC-MS/MS (GC-MS/MS를 이용한 잔류농약 신속검사법 개발)

  • Choi, Yong-Hoon;Nam, Hye-Seon;Hong, Hye-Mi;Lee, Jin-Ha;Chae, Kab-Ryong;Lee, Jong-Ok;Kim, Hee-Yun;Yoon, Sang-Hyeon
    • The Korean Journal of Pesticide Science
    • /
    • v.9 no.4
    • /
    • pp.292-302
    • /
    • 2005
  • Condition of Ion-Trap gas chromatography-mass spectrometry (GC-MS) for rapid screening of 206-pesticides residues in agricultural foodstuffs was optimized. As applying a wide-bore column (10 m${\times}$0.53 mm, DF 0.25 um) connected with a fused silica restrictor (0.6 m${\times}$0.1 mm), a significant retention time reduction was obtained. Additionally, the shape of peaks was sharper and higher than classical GC's and GC-MS's, which allowed lower detection limits. To easily manage many spectral data, both of Electron Ionization(EI) and Chemical Ionization(CI) techniques were adopted in screening procedure. At the following steps, MS-MS technique were used to confirm screened analytes in complicated matrices.

GC/MS and its applications for the analysis of cosmetic produtcts (GC/MS와 화장품 분석의 응용)

  • 노경원
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.19 no.1
    • /
    • pp.1-19
    • /
    • 1993
  • Gas chromatography serves to separate the mixtures into its components, and mass spectrometer is used to analyzing of unknown compounds. But there are many problems the identification of horn compounds using by GC only. As this reason GC/MS a very powerful analyzing technique. Mass spectrometer consists of 1) inlet stem 2) ion source 3) Bass filter 4) detectors and 5) data system. There are two analyzing modes in the GC/MS, those are scan and SIM(selected ion mom toping) modes. Scan mode is used when analyzing unknown compounds and SIM mode al lows the mass spectrometer to detect specific compound with very high sensitivity. As GC/MS applications for the analysis of cosmetic products, volatile compounds in lotion, earn foundation and hair color, and carbon distribution of fatty acids in soap were performed. Also as a new sample pre-treatment technique, head space sampler/GC/MS introduced in order to analyze the volatile compounds in a toothpaste.

  • PDF

Quantitative Analysis of the Ten Phytochmicals in Acer tegmentosum Maxim by UPLC-MS/MS (UPLC-MS/MS를 이용한 산천목 중 10종 성분의 함량 분석)

  • Hwang, Youn-Hwan;Li, Wei;Yang, Hye Jin;Ma, Jin Yeul
    • Korean Journal of Pharmacognosy
    • /
    • v.49 no.1
    • /
    • pp.70-75
    • /
    • 2018
  • Acer tegmentosum Maxim (ATM) has been used to treat hepatic disorders in traditional oriental medicine. However, there is little information about phytochemical constituents for quality control of ATM. In this study, we developed and established a simultaneous analytical method of the 10 marker compounds (three coumarins, 3 flavonoids, 1 lignan, 3 phenolics) in ATM using ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS). Chromatographic separation of ten target analytes was achieved with a Waters Acquity UPLC BEH $C_{18}$ analytical column ($2.1{\times}100mm$, $1.7{\mu}m$), using a mobile phase of 0.1% (v/v) formic acid in water and acetonitrile with gradient elution. Identifications and quantitation of all analytes were performed using a Q-Exactive UPLC-MS/MS system. Correlation coefficients of the calibration curve for all analytes were ${\geq}0.9986$. The values of limits of detection and quantification of all analytes were 0.5-10.0 and 5.0-50.0 ng/mL, respectively. The established UPLC-MS/MS method successfully identified all target analytes in ATM, and the phytochemicals were 0.01-67.98 mg/g in its lyophilized water extract.

Possibilities of Liquid Chromatography Mass Spectrometry (LC-MS)-Based Metabolomics and Lipidomics in the Authentication of Meat Products: A Mini Review

  • Harlina, Putri Widyanti;Maritha, Vevi;Musfiroh, Ida;Huda, Syamsul;Sukri, Nandi;Muchtaridi, Muchtaridi
    • Food Science of Animal Resources
    • /
    • v.42 no.5
    • /
    • pp.744-761
    • /
    • 2022
  • The liquid chromatography mass spectrometry (LC-MS)-based metabolomic and lipidomic methodology has great sensitivity and can describe the fingerprint of metabolites and lipids in pork and beef. This approach is commonly used to identify and characterize small molecules such as metabolites and lipids, in meat products with high accuracy. Since the metabolites and lipids can be used as markers for many properties of a food, they can provide further evidence of the foods authenticity claim. Chromatography coupled to mass spectrometry is used to separate lipids and metabolites from meat samples. The research data usually is compared to lipid and metabolite databases and evaluated using multivariate statistics. LC-MS instruments directly connected to the metabolite and lipid databases software can be used to assess the authenticity of meat products. LC-MS has good selectivity and sensitivity for metabolomic and lipidomic analysis. This review highlighted the combination of metabolomics and lipidomics can be used as a reference for analyzing authentication meat products.

Enhancement of Analyte Ionization in Desoprtion/Ionization on Porous Silicon (DIOS)-Mass Spectrometry(MS)

  • Lee Chang-Soo;Kim Eun-Mi;Lee Sang-Ho;KIm Min-Soo;Kim Yong-Kweon;Kim Byug-Gee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.10 no.3
    • /
    • pp.212-217
    • /
    • 2005
  • Desorption/ionization on silicon mass spectrometry (DIOS-MS) is a relatively new laser desorption/ionization technique for mass spectrometry without employing an organic matrix. This present study was carried to survey the experimental factors to improve the efficiency of DIOS-MS through electrochemical etching condition in structure and morphological properties of the porous silicon. The porous structure of silicon structure and its properties are crucial for the better performance of DIOS-MS and they can be controlled by the suitable selection of electrochemical conditions. The fabrication of porous silicon and ion signals on DIOS-MS were examined as a function of silicon orientation, etching time, etchant, current flux, irradiation, pore size, and pore depth. We have also examined the effect of pre- and post-etching conditions for their effect on DIOS-MS. Finally, we could optimize the electrochemical conditions for the efficient performance of DIOS-MS in the analysis of small molecule such as amino acid, drug and peptides without any unknown noise or fragmentation.

Analytical Methods of Fenpyroximate in Herbal Medicines (생약 중 Fenpyroximate의 분석법 연구)

  • Lee, Ju-Hee;Lee, Yoon-Jeong;Kang, In-Ho;Kim, Do-Hoon;Kang, Shin-Jeong;An, Kyung-A;Lee, Ryun-Kyung;Suh, Sang-Chul;Lee, Jeong-Rim
    • The Korean Journal of Pesticide Science
    • /
    • v.18 no.3
    • /
    • pp.141-147
    • /
    • 2014
  • Fenpyroximate is acaricide of pyrazole group. This acaricide have already been permitted for herb cultivation. This experiment was conducted to establish a determination method for fenpyroximate residue in herbal medicines using HPLC-PDA and HPLC-MS/MS. Fenpyroximate residue was extracted with acetone from samples of herbal which Liquorice Root (Glycyrrhiza uralensis) and Safflower Seed (Carthamus tinctorius Linne). The extract was diluted with saturated saline water and dichloromethane liquid-liquid partition (extraction) was followed to recover fenpyroximate from the aqueous phase. Amino propyl ($NH_2$) and florisil column chromatography was additionally employed for final clean up of the extract. The fenpyroximate was quantitated by HPLC-PDA and HPLC-MS/MS. The herbals were fortified with fenpyroximate at 2 or 3 levels per crop. Mean recovery ratio were ranged from 72.0 to 106.4%. The coefficients of variation were ranged from 0.2 to 4.4. Therefore, this analytical method was reproducible and sensitive enough to determine the residue of fenpyroximate in herbal medicines.

Engineering Recombinant Streptomyces coelicolor Malate Synthase with Improved Thermal Properties by Directed Mutagenesis

  • Koh, Ro-Sita;Goh, Liuh-Ling;Sim, Tiow-Suan
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.3
    • /
    • pp.547-552
    • /
    • 2004
  • Streptomyces thermovulgans malate synthase (stMS) is known to be more thermostable and thermoactive than S. coelicolor malate synthase (scMS). Therefore, based on the amino acid sequence of stMS, 3 scMS mutants, namely P186R, T8PL9P, and T8PL9PP186R, were created by site-directed mutagenesis in an attempt to engineer a more thermoactive and thermostable enzyme. An enzymatic analysis of the wild-type and mutant MS revealed that P186R and T8PL9PP186R were more thermoactive than the wild-type scMS and T8PL9P. Furthermore, all 3 mutants exhibited a greater thermo stability than scMS, thereby suggesting that both R186 and P8P9 can cause increased thermo stability in scMS.

Comparative Proteomic Analysis of Human Amniotic Fluid Supernatants with Down Syndrome Using Mass Spectrometry

  • Park, Ji-Sook;Cha, Dong-Hyun;Jung, Jin-Woo;Kim, Young-Hwan;Lee, Sook-Hwan;Kim, Young-Jun;Kim, Kwang-Pyo
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.6
    • /
    • pp.959-967
    • /
    • 2010
  • Down syndrome (DS) is an abnormality of the 21st chromosome that commonly occurs in children born to older women. Thus, amniotic fluid (AF) is usually collected from such women for prenatal diagnosis. This study analyzed human AF supernatants (AFS) using a mass spectrometric (MS) approach to search for candidate biomarkers of a DS pregnancy. The AFS were collected from older pregnant women at weeks 16-18 of their gestation by amniocentesis for cytogenetic analysis. The AFS from the pregnancies carrying DS (n=4) or chromosomally normal (n=6) fetuses, as revealed by the cytogenetic analysis, were then subjected to global protein profiling based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). Affinity chromatography was also applied prior to the LC-ESI-MS/MS to minimize the masking effect of highly abundant albumin and immunoglobulin and thereby increase the diversity of the identified proteins. As a result, at least 30 new AFS proteins were identified and 44 AFS proteins were found to be differentially expressed between the DS and normal cases, where 6 of the proteins were unique to the DS cases and 11 were unique to the chromosomally normal cases. In addition, in the DS cases, 19 AFS proteins were downregulated and 8 were upregulated to varying degrees. A Western blot analysis confirmed the LC-ESI-MS/MS data, indicating that the combined detection of apolipoprotein A-II (apoA-II) and alpha-fetoprotein (AFP) could be a potential tool for diagnosing DS cases.