• Title/Summary/Keyword: ML 검출

Search Result 521, Processing Time 0.023 seconds

Rapid and Precise Determination of Pb Isotope Ratios Using Mu1ti-Collector ICP/MS (다검출기 유도결합 플라즈마 질량분석기를 이용한 신속하고 정밀한 Pb 동위원소 분석)

  • 최만식;정창식;신형선;임태선
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.157-171
    • /
    • 2001
  • This study investigated the effects of Pb/Tl ratio, Pb concentration and concomitant matrix elements on the measurement of Pb isotope ratios using multi-collector ICP/MS (AXIOM MC model). Accuracy and reproducibility of Pb isotope ratios in NBS 981 solution were estimated for 42 data measured from March to August 2001. Pb isotopes measured in rocks, bronzes and sediments were compared to data measured by TIMS. Reproducibilities for $^{206}Pb/^{204}Pb,\; ^{207}Pb/^{204}Pb,\;and\;^{208}Pb/^{204}Pb$ ratio were about 500 ppm (2sd) and for $^{207}Pb/^{206}Pb$\;and\;^{208}Pb/^{206}Pb$ were 100~200 ppm for 200 ng of Pb in NBS 981 solution. The optimum conditions for the analysis of Pb isotope ratios with AXIOM MC for best accuracy and reproducibility were defined as follows; 1) Pb/Tl ratio is about 10 2) Pb concentration is about 100 ng/ml 3) correction for mass discrimination is performed by exponential law using 2.3887 of $^{205}Tl/^{203}Tl$ and Pb mass fractionation factor empirically obtained from $ln(^{208}Pb/^{206}Pb)-ln(^{205}Tl/^{203}Tl)$ relationship. The sample data measured with MC/ICP/MS for acid-digested and chemically separated rock samples, and acid-digested bronze samples and sediment samples coincide with those of TIMS within analytical errors. Therefore, MC/ICP/MS is a rapid analytical technique for Pb isotope ratios with the similar precision compared with TIMS.

  • PDF

Molybdenum Isotope Analysis of Standard Reference Materials (표준물질을 이용한 몰리브덴 동위원소 분석)

  • Jo, Yunsoo;Kil, Youngwoo;Ryu, Jongsik;Seol, Junghwan;Nguyen, The Cong;Jung, Woochul;Park, Sanghee
    • Economic and Environmental Geology
    • /
    • v.49 no.2
    • /
    • pp.89-95
    • /
    • 2016
  • Mo isotope, one of highly redox-sensitive isotopes, has been shown to be useful tracers of geochemical processes. Many studies for Mo isotope have documented with the help of recently developed analysis tools, but it has not yet been documented in the Korea. In this study, we introduce two-stage column separation method of Mo using column tube (BioRad PolyPrep(R) column, 10 ml) and anion exchange resin (BioRad Resin AG(R) 1-X8, 200-400 mesh). Mo isotope ratios in the solid SRMs (BHVO-2, SDO-1, PACS-2) and liquid SRM (IAPSO) were measured on MC-ICP-MS (Multi-collector Inductively Coupled Plasma Mass Spectrometer) and then compared with reference Mo isotope ratios. Mo isotope ratios in our study overlap with reference Mo isotope ratios within analytical error.

Characterization of Plasmid-Mediated SHV-11 β-lactamase Gene of Klebsiella pneumoniae Isolated from the Clinical Specimens (임상검체로부터 분리한 플라스미드 매개성 SHV-11 β-lactamase 유전자의 특성)

  • Kim, Yun-Tae;Lee, Sang-Hoo;Jang, Ji-Hyun;Kim, Tae-Un;Choi, Seok-Cheol;Baik, Hyung-Suk;Lee, Kyoung-Ryul;Yoon, Hye-Ryoung;Kim, Young-Jin
    • Journal of Life Science
    • /
    • v.19 no.12
    • /
    • pp.1718-1723
    • /
    • 2009
  • In this study, we characterized extended-spectrum $\beta$-lactamase (ESBL)-producing Enterobacteriaceae isolated from clinical specimens in Korea and found two strains harboring plasmid-mediated $bla_{SHV-11}$, Klebsiella pneumoniae. First, the isolates were detected using the Vitek system and confirmed by the double-disk synergy test. The classification of gene coding for ESBL was also performed by polymerase chain reactions and followed by DNA sequencing. The transmission of genes was confirmed by transconjugation and transformation. Resistant expression of transformants was determined by broth microdilution minimal inhibitory concentration test. Genotypic analysis revealed that one strain harbored the $bla_{TEM-1}$, $bla_{SHV-11}$ and $bla_{CTX-M-15}$ and the other strain harbored the $bla_{SHV-11}$ and $bla_{CTX-M-15}$. They showed high resistance to oxyiminocephalosphorins (3rd-generation cephalosporins), while the transformant containing only $bla_{SHV-11}$ did not show any resistance to the antibiotics.

Determination of new anti-HIV agents, the KR-V series, in rat plasma using microbore high-performance liquid chromatography (HPLC를 이용한 랫드혈장내 새로운 항HIV제 KR-V series의 분석법)

  • Lee, Young-mi;Park, Myung-jin;Kim, Jin-suk;Shin, Ho-chul
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.4
    • /
    • pp.741-746
    • /
    • 2000
  • We have developed a rapid, simple and precise high-performance liquid chromatographic (HPLC) method using an UV detection system for the determination of new anti-HIV candidates, nineteen KR-V compounds, in rat plasma. We used a analytical columnn of $C_{18}$ ($5{\mu}m$, $250{\times}2.0mm$ I.D.) and a mobile phase of water and ACN mixture (40/60, v/v). Under these conditions, all the KR-V compounds were readily separated from plasma with retention times of 4-12 min. The limits of quantitation for the 19 KR-V compounds were 15-30 ng/ml. The recoveries from the plasma were higher than 85% (C.V.<10%) with exception of KR-V 2, 7 and 15. The compounds KR-V 2, 7 and 15, containing ester moieties, were found to be unstable in plasma. This result suggests that esters, like KR -V 2, 7 and 15, should be excluded from future structure design studies of anti-HIV KR-V agents. In conclusion, the current HPLC method is a valuable analytical tool for investigating the pharmacokinetics of the KR-V series in rats.

  • PDF

1,3-bisdicyanovinylindane 색소를 이용한 선택적 $Hg^{2+}$ 감지 특성

  • Kim, Su-Ho;Kim, Young-Sung;Kim, Sung-Hoon;Son, Young-A
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2009.11a
    • /
    • pp.19-20
    • /
    • 2009
  • 최근 화학, 물리, 생명과학, 전기, 전자등의 다양한 분야에 활발하게 연구가 이루어지고 있는 초분자 화학은 선택적 분자인지를 위한 효율적인 골격구조와 나아가 다양한 계에 응용할 수 있다. 초분자 화학의 분자인지 과정의 특징은 일반적으로 수용체 (receptor 혹은 host)가 목표가 되는 기질 (substrate, analyte, 혹은 guest)에 대하여 선택적으로 식별하고 반응하는 것이다. 비공유 결합성 상호작용에 의하여 이루어지는 초분자 화학의 분자 인지 과정의 특징은 일반적으로 수용체 (receptor 혹은 host)가 목표가 되는 기질 (substrate, analyte, 혹은 guest)에 대하여 선택적으로 식별하고 반응하는 것이다. 이는 공유결합을 이용하는 분자화학과는 차별화 된 것이다. 수용체는 간단한 구조의 화합물 및 금속 이온들과 같은 기질과 가역적으로 상호 작용할 수 있는 착물을 형성한다. 최근들어 급격한 산업화가 진행되어 환경문제가 심각하게 대두 되어져 왔고, 그 중에서 특히 수은이나 카드뮴에 의한 질병, 납에 의한 중독 등 중금속에 의한 오염이 크게 나타남에도 불구하고, 현재 그러한 중금속을 검출함에 있어 많은 비용과 시간이 드는 문제점이 있다. 또한 우리에게 이로운 금속은 효율적 분석을 통해 환경계와 의료계에 많은 도움을 줄 것으로 사례되므로 화학센서 기술의 개발은 절실히 요구되어지고 있다. 이에 새로운 1,3-bisdicyanovinylindane 을 통해 $Hg^{2+}$ 금속의 감지 여부 알아보고, 그 특성을 파악하고자 한다. 1,3-indandion (2.18g, 14.9mmol), malononitrile (2.95g, 44.7mmol), ethanol 50ml를 20분간 상온에서 용해시킨다. 후에 sodium trihydrate acetate(3.05g)을 첨가한 후 5시간 동안 환류반응 시킨다. 이 과정에서 얻어진 용액을 필터과정을 통하여 에서 합성 반응 중에 생성된 불순물(1,3-dicyanovinylindane-1-one, monocondensation)을 제거한다. 필터과정을 통해 걸러진 미 반응 물질을 제�G 용반응욕액을 증류수(100ml)를 이용하여 희석시키고 난 후 염산을 이용, 산성화 시켜 고체 생성물을 얻어낸다. 이렇게 생성된 고체 생성물은 다시 필터 및 건조를 통하여 회색의 고체 화합물을 얻어낸다. 1,3-bisdicyanovinylindane과 금속이온에 대한 감응도를 확인하기 위하여 metanol/water(1:2)을 용매로 하여 금속이온의 농도를 변화시켜 발색특성을 살펴보았다. 본 색소화합물과 Hg2+에 대한 UV 흡광도 변화 적정결과와 그 화합물의 상태 살펴본 결과 금속이온이 0.2ml씩 더 참가되면서 색의 변화를 뚜렷하게 나타내었다. 반면 그 밖에 이온($Fe^{3+}$, $Ag^{2+}$, $Pd^{2+}$, $Zn^2$, $Fe^{2+}$, $Cu^{2+}$, $Pb^{2+}$)은 UV 흡광도 변화가 적거나 변화 자체가 없었다. 하지만 과량의 $Fe^{3+}$, $Ag^{2+}$, $Pd^{2+}$는 색상 변화를 나타내었으며,이와 같은 흡광도 변화는 금속에 따라 약간의 차이가 있지만, 420nm를 등흡수점으로 하여, 580nm의 파장 영역에 있는 흡수 밴드의 세기는 감소하는 반면 400nm 파장 영역에 있는 흡수 밴드의 세기가 증가하였다. 1,3-bisdicyanovinylindane 화합물은 다양한 생물계 및 환경계에서 요구되는 micro mol에서 milli mol 농도 영역의 $Hg^{2+}$ 이온의 선택적이고 민감한 검출과 정량적인 분석에 유용하게 사용될 수 있을 것이다.

  • PDF

Studies on the Characteristics of Kefir Grains Collected from Korean (한국에서 수집된 케퍼 그레인의 특성에 대한 연구)

  • 박선정;주영철;장윤현;차성관
    • Food Science of Animal Resources
    • /
    • v.23 no.3
    • /
    • pp.262-268
    • /
    • 2003
  • Kefir is a traditional fermented milk in Caucasusian area and is made mainly of milk fermented with lactic acid bacteria and yeasts. Six typical kefir grains were selected from ten kefir grains collected from different locals in Korea. Kefir grains were gelatinous in texture and had various shapes of villi, grapes, leaves, hulled millets, and towels. To investigate predominant microflora of kefir grains, SPC, MRS, M17, Rogosa, and APT agar media were used for viable cell count MRS, SPC, and Rogosa media were most acceptable for bacterial cell counts of the selected kefir grains. From one or two of the SPC agar plates which contained around 25∼50 colonies, all grown colonies were isolated and identified. Most predominant bacteria was identified as Lactobacillus fermentum by API 50 CHL kit. The proportions of Lb. fermentum and Lb. brevis among the total identified bacteria were around 41~88% and M4%, respectively. To select the best preservation method for kefir grains, refrigeration, freezing, and freeze drying were compared. Freeze drying was found most suitable for the preservation of kefir grains, based upon their acid-producing activities and production of off-flavors.

A Rapid Method for Determination of ATP and Its Related Compounds in Dried Fish and Shellfish Products Using HPLC (HPLC에 의한 시판수산건제품의 ATP분해생성물의 신속정량법)

  • LEE Eung-Ho;KOO Jae-Geun;AHN Chang-Bum;CHA Yong-Jun;OH Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.5
    • /
    • pp.368-372
    • /
    • 1984
  • This paper deals with a rapid method for determination of ATP and its related compounds in fish and shellfish products using high performance liquid chromatography(HPLC). The HPLC used is a HPLC/ALC-224 equiped with UV-spectrophotometer (254 nm) as detector and integrator (Yanagimoto system-1000). The column used is a stainless steel tubing ($30.0\;cm{\times}3.9\;mm\;i.d.$) packed with ${\mu}-Bon-dapak\;C_{18}$. A mixture of $1\%$ triethylamine-phosphoric acid(pH6.5) was used as an eluent and the flow rate of the eluent was controlled at 2 ml/min. For the separation of ATP and its related compounds, a standard mixture of ATP, ADP, AMP, IMP, inosine and hypoxanthine was subjected to HPLC under the above mentioned conditions. Six peaks were obtained with retention times within 20 min, and elution order were hypoxanthine, IMP, inosine, AMP, ADP and ATP. But 5'-IMP and 5'-GMP fractions were not separated by this method. In generally, IMP content in boiled-dried fish and shellfish products purchased from the market was comparatively higher than that of other nucleotides. Especially, boiled-dried big eye herring marked higher value in IMP content than other boiled-dried ones. Hypoxanthine and inosine were major components of ATP-related compounds in dried products and seasoned-dried ones. And IMP content in seasoned-dried products was higher than that of dried ones. This fact is suggested that a part of IMP in seasoned-dried ones was derived from flavoring matter (MSG, 5'-IMP and 5'-GMP) which is added during the seasoning treatment.

  • PDF

Production of Egg Yolk Immunoglobulin and Its Application for Pepper mild mottle virus in Serological Tests (Pepper mild mottle virus에 대한 난황항체의 생산과 혈청학적 진단에의 활용)

  • Han Jung-Heon;Lee Cheol-Ho;Kim Young-Ho;La Yong-Joon
    • Research in Plant Disease
    • /
    • v.12 no.2
    • /
    • pp.144-147
    • /
    • 2006
  • Egg yolk immunoglobulin (IgY) is much widely used in medical fields, but its use in serology of plant viruses is much limited. We produced an IgY against pepper mild mottle virus (PMMoV) and applied it to several serological tests. Polyclonal antibodies were obtained from the egg yolk of chicken immunized with a total of 2mg of purified PMMoV over 2 months. The titers of antibodies were measured with the ring-test over six months after the first injection. The highest.titers of IgY was 1/2,560 at 2 months after the first injection. Approximately 60-80 mg of IgY were obtained from one egg yolk. Using the IgY, 1ng/ml of purified PMMoV was detected with the indirect ELISA. Gelrite gel double diffusion test, ELISA and tissue immuno-binding assay employing IgY gave similar sensitivity and specificity to those of IgG developed in rabbit. Therefore, the IgY which can be obtained in large quantities from a chicken, might be useful for the antibody production and the serology of plant viruses.

Validation and Content Analysis of Putrescine in the Venom of Honeybee (Apis mellifera L.) (서양종꿀벌 일벌독에 함유된 putrescine 밸리데이션 및 함량 분석)

  • Choi, Hong Min;Kim, Hyo Young;Kim, Se Gun;Han, Sang Mi
    • Korean journal of applied entomology
    • /
    • v.60 no.3
    • /
    • pp.263-268
    • /
    • 2021
  • The venom of honeybees (Apis mellifera L.) is used to treat many diseases because of its anti-inflammatory and analgesic effects. Bee venom consists of several biologically active molecules and exhibits remarkable anti-cancer effects. However, biological amines, which exhibit diverse functionality such as anti-inflammatory and antibacterial effects, have not been previously reported in bee venom. In this study, we determined the content of putrescine in bee venom by using ultra-performance liquid chromatography. The specificity, accuracy, and precision of the assay were assessed, and the assay validated. The linearity of the putrescine assay was r ≥ 0.99, indicating a moderate level of putrescine in the bee venom. The limit of detection and limit of quantification were both 0.9 ㎍/mL, while the rate of recovery was 96.4%-99.9%. The relative standard deviation (RSD) of the intra-day precision and inter-day precision of the putrescine assay were 0.16% - 0.23% and 0.09% - 0.36%, respectively, with the RSD ≤ 5% indicating excellent precision. Thus, the linearity, limit of detection, limit of quantification, and recovery rate of the putrescine assay were satisfactory. The analysis of the bee venom showed that the putrescine content was 3.1 ± 0.09 mg/g. This study provides fundamental data on putrescine content in bee venom, which will prove useful in further studies of its bioactivity.

Study for Diagnostic Efficacy of Minibronchoalveolar Lavage in the Detection of Etiologic Agents of Ventilator-associated Pneumonia in Patients Receiving Antibiotics (항생제를 사용하고 있었던 인공호흡기 연관 폐렴환자에서의 원인균 발견을 위한 소량 기관지폐포세척술의 진단적 효용성에 관한 연구)

  • Moon, Doo-Seop;Lim, Chae-Man;Pai, Chik-Hyun;Kim, Mi-Na;Chin, Jae-Yong;Shim, Tae-Sun;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.3
    • /
    • pp.321-330
    • /
    • 1999
  • Background : Early diagnosis and proper antibiotic treatment are very important in the management of ventilator-associated pneumonia (VAP) because of its high mortality. Bronchoscopy with a protected specimen brush (PSB) has been considered the standard method to isolate the causative organisms of VAP. However, this method burdens consumer economically to purchase a PSB. Another useful method for the diagnosis of VAP is quantitative cultures of aspirated specimens through bronchoscopic bronchoalveolar lavage (BAL), for which the infusion of more than 120 m1 of saline has been recommended for adequate sampling of a pulmonary segment. However, occasionally it leads to deterioration of the patient's condition. We studied the diagnostic efficacy of minibronchoalveolar lavage (miniBAL), which retrieves only 25 ml of BAL fluid, in the isolation of causative organisms of VAP. Methods: We included 38 consecutive patients (41 cases) suspected of having VAP on the basis of clinical evidence, who had received antibiotics before the bronchoscopy. The two diagnostic techniques of PSB and miniBAL, which were performed one after another at the same pulmonary segment, 'were compared prospectively. The cut-off values for quantitative cultures to define causative bacteria of VAP were more than $10^3$ colony-forming units (cfu)/ml for PSB and more than $10^4$ cfu/ml for BAL. Results: The amount of instilled normal saline required to retrieve 25 ml of BAL fluid was $93{\pm}32 ml$ (mean${\pm}$SD). The detection rate of causative agents was 46.3% (19/41) with PSB and 43.9% (18/41) with miniBAL. The concordance rate of PSB and miniBAL in the bacterial culture was 85.4% (35/41). Although arterial blood oxygen saturation dropped significantly (p<0.05) during ($92{\pm}10%$) and 10 min after ($95{\pm}3%$) miniBAL compared with the baseline ($97{\pm}3%$), all except 3 cases were within normal ranges. The significantly elevated heart rate during ($l25{\pm}24$/min, p<0.05) miniBAL compared with the baseline ($1l1{\pm}22$/min) recovered again in 10 min after ($111{\pm}26$/min) miniBAL. Transient hypotension was developed during the procedure in two cases. The procedure was stopped in one case due to atrial flutter. Conclusion: MiniBAL is a safe and effective technique to detect the causative organisms of VAP.

  • PDF