• 제목/요약/키워드: MIP image

검색결과 53건 처리시간 0.02초

Enhancement of MRI angiogram with modified MIP method

  • 이동혁;김종효;한만청;민병구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.72-74
    • /
    • 1997
  • We have developed a 3-D image processing and display technique that include image resampling, modification of MIP, and fusion of MIP image and volumetric rendered image. This technique facilitates the visualization of the three-dimensional spatial relationship between vasculature and surrounding organs by overlapping the MIP image on the volumetric rendered image of the organ. We applied this technique to a MR brain image data to produce an MRI angiogram that is overlapped with 3-D volume rendered image of brain. MIP technique was used to visualize the vasculature of brain, and volume rendering was used to visualize the other structures of brain. The two images are fused after adjustment of contrast and brightness levels of each image in such a way that both the vasculature and brain structure are well visualized either by selecting the maximum value of each image or by assigning different color table to each image. The resultant image with this technique visualizes both the brain structure and vasculature simultaneously, allowing the physicians to inspect their relationship more easily. The presented technique will be useful for surgical planning for neurosurgery.

  • PDF

사용자 선호에 기반한 효율적 최대 휘소 가시화 알고리즘의 선택 방법 (Algorithm Selection Method for Efficient Maximum Intensity Projection Based on User Preference)

  • 한철희;계희원
    • 한국멀티미디어학회논문지
    • /
    • 제21권2호
    • /
    • pp.87-97
    • /
    • 2018
  • Maximum intensity projection (MIP) is a common visualization technique in medical imaging system. A typical method to improve the performance of MIP is empty space leaping, which skips unnecessary area. This research proposes a new method to improve the existing empty space leaping. In order to skip more regions, we introduce a variety of acceleration strategies that use some tolerance given by the user to take part in image quality loss. Each proposed method shows various image quality and speed, and this study compares them to select the best one. Experimental results show that it is most efficient to add a constant tolerance function when the image quality required by the user is low. Conversely, when the user required image quality is high, a function with a low tolerance of volume center is most effective. Applying the proposed method to general MIP visualization can generate a relatively high quality image in a short time.

유방자기공명영상에서 3 차원 최대 강도 투사 재건 영상의 유용성 (Usefulness of Three-Dimensional Maximal Intensity Projection (MIP) Reconstruction Image in Breast MRI)

  • 김현성;강봉주;김성헌;최재정;이지혜
    • Investigative Magnetic Resonance Imaging
    • /
    • 제13권2호
    • /
    • pp.183-189
    • /
    • 2009
  • 목적 : 유방자기공명영상에서 3 차원 최대 강도 투사 (3D MIP) 재건 영상의 유용성을 알아보고자 하였다. 대상 및 방법 : 유방암으로 진단받고 유방자기공명영상을 시행한 27명의 환자의 54개의 유방을 대상으로 하였다. GE Signa Excite Twin speed (GE medical system, Wisconsin, USA) 1.5 T 기기를 이용하여 기본 영상으로 축면 T2 강조 T1 강조 영상과 시상면 T1 강조 지방 억제 영상, 역동적 조영 증강 영상과 감산 영상을 얻었다. 이후 초기 역동적 조영증강 영상의 감산영상으로 워크스테이견 (GE Medical system)을 이용하여 3D MIP 영상을 얻었다. 3D MIP 영상과 기본 유방자기공명영상에서 발견된 병변을 ACR BI-$RADS^{(R)}$ MRI lexicon에 따라 분석하였다. 각각의 영상에서 발견된 병변의 소견들을 비교하고 3D MIP에서 기본자기공명영상에서 보다 추가적인 정보를 얻을 수 있는지 알아보았다. 결과 : 종괴의 경우 기본 유방자기공명영상에서 보이는 56개 중 43개가 3D MIP 영상에서 발견되었다 (76.8%). 비종괴성 조영 증강의 경우 20개 중 17개가 발견되었다 (85%). 169개의 초점성 조영증강 병변이 3D MIP 영상에서, 109개가 기본 유방자기공명영상에서 확인되었다. 3D MIP 영상에서 60.9%의 category 3병변이 발견되었고(14/23), 68.87%의 category 4 병변 (11/16), 100%의 category 5병변 (28/28)이 발견되었다. 3D MIP 영상에서 분석된 조영증강 병변들의 category가 기본 유방 자기공명 영상의 결과들과 통계적으로 일치하였다(p-value < 0.0001). 기본 유방 자기공명 영상에서 초점으로 분석된 2개의 병변들이 3D MIP 영상에서는 다초점성의 악성 병변으로 발견되었고, 1개의 추가적 병변이 3D MIP 영상에서만 발견되었다. 결론 : 3D MIP 영상은 한계점들을 갖고 있으나, 기본 유방자기공명영상의 분석에 있어 추가적으로 이용 시 유용하다.

  • PDF

Fusion & Maximum Intensity Projection 3D 재구성 영상에서 Region Cut Subtraction의 유용성 (Usefulness of Region Cut Subtraction in Fusion & MIP 3D Reconstruction Image)

  • 문아름;지용기;최성욱;이혁;이규복;석재동
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.18-23
    • /
    • 2010
  • 최근 PET/CT영상의 발달로 종양의 진단 및 평가를 통해 임상에 많은 도움을 주고 있다. 특히 PET와 CT를 융합한 Fusion PET/CT영상이나 2차원 PET영상을 3차원 영상으로 재구성한 최대강도영상(Maximum Intensity Projection)은 전체적인 병변을 한눈에 시각화하는 데 유용하게 쓰이고 있다. 하지만 Fusion & MIP 3D 재구성 영상에서 $^{18}F$-FDG의 생리적 배출로 소변이나 요루주머니에 의한 열소가 나타나 병변이 겹쳐져 육안적으로 병변을 구별하는 데 어려움이 있다. 본 연구에서는 소변에 의해 나타나는 열소 부위를 제거하여 병변의 분별력을 향상하고자 한다. 2008년 9월부터 2009년 3월까지 내원한 환자 중 PET/CT 검사에서 자궁, 방광, 직장 부위의 질환으로 잔존하는 소변량이 많은 환자들을 대상으로 하였다. 분석장비는 GE사의 Advantage Workstation AW4.3 05 버전 Volume Viewer 프로그램을 사용하였다. 분석 방법은 2D PET axial volume 영상에서 제거하고자 하는 region에 ROI를 설정하여 Cut Outside를 선택한 후 coronal volume 영상도 동일한 방법을 적용한다. 다음으로 3D Tools의 threshold 값을 지정하고, Advanced Processing에서 Subtraction을 선택하여 차집합 방식으로 소변 영상만을 소거한다. 이렇게 Region Cut Subtraction이 된 2D PET영상과 CT영상으로 Fusion영상과 MIP영상을 만들어 Region Cut Subtraction하지 않은 영상과 비교한다. Fusion & MIP 3D 재구성 영상에서 Advantage Workstation AW4.3 05버전의 Region Cut Subtraction으로 환자의 소변이나 요루주머니에 의한 열소 부위를 제거할 수 있었다. Region Cut Definition을 사용한 영상에서 그렇지 않은 영상보다 소변 섭취 때문에 구별이 어렵던 병변과의 경계가 보다 명확하게 재구성되었다. 영상을 재구성하는 과정에서 Region Cut Subtraction을 사용하여 열소 부위를 제거한다면 기존에 사용하던 단순 역치범위 설정에 의한 영상 소거법보다 우수한 진단적 정보를 제공할 것이다. 특히 방광, 자궁, 직장 부위 질환의 경우, 판독의와 임상의에게 판독에 보다 유용한 영상 정보를 제공하고, 영상의 질적 향상에 도움이 될 것이라 판단된다.

  • PDF

간동맥 색전술 환자의 복부단층촬영 후 PC 환경에서 MIP재구성영상을 이용한 간문맥평가에 관한 고찰 (A Study on Evaluation of Portal Vein by Utilizing MIP Reconstruction in the PC Environment after Abdomen CT of Hepatic Artery Embolization Patients)

  • 김영근;장영일;허영남
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.13-17
    • /
    • 2001
  • When most patients are diagnosed with the quiet progressed hepatoma which often would make the operation impossible, the Interventional Radiology hepatic artery embolization is an extremely useful method for such patients. An existence of the malfunction is evaluated by gaining a portal vein image as a delayed phase image after injecting a contrast media into the superior mesenteric artery. However, it is difficult to make a definite judgement due to the extended exposure time with the peristalsis and the intestine gas obstructing the sharpness of the image when the Patient exposure time increases and due to the increased usage of contrast media and its side effect. The portal vein can be evaluated by obtaining the MIP image after reconstructing a 3-dimensional personal computer setting using the 2-dimensional from an enhancement abdomen CT image that is almost a requisite in operation to a hepatoma patient. Such method nay prevent a decrease in the quality of image based upon the time delay and intestine gas; also, because the patient exposure dose and contrast media usage may be reduced, it is a new, valuable way to decide the operational matter of hepatic artery embolization on a pre-angiography.

  • PDF

폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가 (A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment)

  • 최병걸;최창헌;윤일규;양진성;이동명;박주미
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.59-67
    • /
    • 2014
  • 목 적 : 폐암의 정위적체부방사선치료시 실제 적용하고 있는 최대강도투사(MIP) 영상과 호흡위상별(0~90%)영상에서 3차원적으로 재구성된 선량 분포 차이를 평가하고자 한다. 대상 및 방법 : 본원에서 정위적체부방사선치료를 시행한 비소세포성 폐암(NSCLC) 환자 5명을 대상으로 4차원 전산화단층영상을 시행하여 10개의 호흡위상별 영상을 획득한 후 최대강도투사 영상을 재구성하여 각 호흡위상별 치료계획을 수립하였고, 2차원 이온전리함과 선량분석프로그램 COMPASS(IBA dosimetry, Schwarzenbruck, Germany)을 이용하여 3차원적으로 재구성된 선량분포를 측정하였다. 이를 이용하여 치료계획 선량분포와 실제 측정 선량분포의 일치성 여부 및 최대강도투사 영상과 호흡위상별 영상에서 선량 분포의 차이를 정량적으로 비교 분석하였다. 결 과 : 최대강도투사 영상 및 호흡위상별 영상에서의 선량분포의 일치성을 알아보기 위한 감마분석 통과율은 대상 환자 모두 99%이상으로 평가기준을 만족 시켰으며, 각각의 환자들에 대한 최대강도투사 영상과 호흡위상별 영상에서 재구성된 선량의 HI(Homogeneity Index) 차이의 평균은 -0.03~0.04로 크지 않았으며, PTV(Planning Target Volume)의 Dmax 차이는 평균 3.30 cGy, 척수는 평균 40 cGy, 양측 폐, 우폐, 좌폐의 $V_{20}$, $V_{10}$, $V_5$ 차이는 평균 -0.04~2.32% 차이를 나타내었다. 또한 모든 환자에 대한 최대강도투사 영상과 호흡위상별 영상에서 재구성된 선량의 HI 차이의 평균은 -0.03~0.03로 크지 않았으며, PTV의 Dmax 차이의 평균은 10% 영상에서 가장 차이가 작았고, 70% 영상에서 가장 큰 차이를 나타내었다. 척수의 Dmax차이의 평균은 50% 영상에서 가장 차이가 작았고, 0% 영상에서 가장 큰 차이를 나타내었다. 폐 $V_{20}$, $V_{10}$, $V_5$의 차이의 평균은 호흡위상별로 일정한 경향성을 나타내지 않았다. 결 론 : 본 연구를 통해 최대강도투사 영상과 각 호흡위상별 영상에서 측정되어 3차원적으로 재구성된 선량분포차이는 일정한 경향을 나타내지는 않았지만 특정 호흡위상에서 선량 분포 차이가 상이한 경우를 볼 수 있었다. 종양의 위치 및 호흡 움직임이 유사한 대상환자군을 선정하여 체계적인 연구를 통해 데이터화 하게 되면 폐와 같이 움직임이 큰 장기의 정위적체부방사선치료시 특정 호흡위상에서 획득한 영상에서의 치료계획이 실제 치료에 적용되어야 하는지에 대한 적합성 여부를 판단 할 수 있을 것이라고 사료된다.

최대강도투사를 이용한 관찰 위치와 거리에 최적화 된 입체 자기공명 뇌 혈관영상 재구성 (Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP)

  • 신석현;황도식
    • Investigative Magnetic Resonance Imaging
    • /
    • 제16권1호
    • /
    • pp.67-75
    • /
    • 2012
  • 목적 : 뇌에 분포하는 동맥혈관을 관찰할 때 흔히 자기공명 뇌혈관 데이터(Magnetic Resonance Angiography, MRA)를 이용한다. 하지만 뇌혈관 데이터의 경우 관찰하고자 하는 부위의 혈관을 직접적으로 관찰하기 어렵다. 이러한 3차원 데이터를 2차원 디스플레이 장치에 나타내기 위해 최대강도투사(Maximum Intensity Projection, MIP) 영상이 흔히 이용된다. 데이터의 투사방향에 위치한 복셀들 중 최대값을 가지는 복셀을 투사하여 최대강도투사 영상을 얻게 된다. 혈관의 경우 큰 복셀값을 가지기 때문에 영상에서 밝게 나타난다. 하지만 투사방향에 중첩되어 있는 일부 혈관들이 투사하는 과정에서 최대값을 가지는 혈관들에 가려져 나타나지 않게 되기 때문에 깊이 정보를 잃게 된다. 또한 정해진 위치에서의 투사영상 밖에 얻을 수 없다는 단점이 있다. 본 논문에서는 기존의 최대강도투사 영상이 가지는 이러한 단점들을 개선하여 뇌혈관의 분포를 3차원 공간상에서 최적화 된 입체영상으로 보는 새로운 방법을 제안하였다. 대상 및 방법 : 우리는 4개의 채널 코일과 3.0T 자기공명영상장치 (Siemens Tim Trio MRI scanner)를 이용하여 피험자의 머리를 고정시키고 3차원 위상대조 (Phase-Contrast, PC) 시퀀스를 적용하여 3차원 뇌혈관 데이터를 얻었다. 얻어진뇌혈관 데이터의 중심점을 기준으로 3차원 공간 회전 알고리즘을 적용하여 회전된 새로운 데이터를 얻은 다음 이 데이터를 기준 수평면상에 투사하여 뇌혈관에 대한 2차원 최대강도투사 영상을 구한다. 이 때 입체영상 구현을 위해 두 눈과 데이터의 중심이 이루는 수렴각에 맞게 뇌혈관 데이터를 각각 공간 회전시킨 후 투사하여 각각의 눈에 적합한 영상들을 구하고 이를 적청안경방식 (anaglyph)을 이용하여 관찰함으로써 최적의 입체감을 가지는 최대강도투사 영상을 얻는다. 결과 : 결과 영상을 살펴보면 우선 기존의 방법들에서는 불가능했던 뇌혈관 데이터의 다양한 위치에서의 최대강도투사 영상이 가능해졌다는 것을 알 수 있다. 또한 관찰자와 데이터 사이의 거리와 두 눈 사이의 거리를 고려하여 보다 사실적인 입체감을 가지는 입체 최대강도투사 영상을 얻었다. 결론적으로 관찰자가 바라보는 방향과 관찰자와 데이터 사이의 거리에 따른 최적의 입체영상을 얻을 수 있었다. 결론 : 제안하는 방법은 단일 최대강도투사 영상을 관찰자의 위치를 고려하여 입체영상으로 변환시킴으로써 최적의 입체감을 가지는 입체 투사 영상을 구하였다. 그리고 구면좌표계 상에서 뇌혈관 데이터의 다양한 투사방향에서의 최대강도투사 영상을 나타낼 수 있었다. 추후 알고리즘 최적화와 병렬연산 프로세스가 적용된다면 진단과 수술 계획에 필요한 뇌혈관의 입체 정보들을 실시간으로 제공해 줄 수 있을 것으로 예상된다.

쇄골하동맥 혈전증에서의 MDCT 혈관조영술의 3D 영상 (MDCT Angiography of the Subclavian Artery Thrombosis of the 3D Findings)

  • 권대철
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.813-819
    • /
    • 2018
  • MDCT의 3D 유용성을 입증하기 위해 쇄골하 혈전증을 수반한 73세 남자 환자를 대상으로 MIP, 볼륨렌더링, MPR의 3D 영상을 획득하여 쇄골하동맥의 혈전증을 명확하게 탐지하고 위치를 확인하여 임상에서 기초자료를 제공하여 환자의 진단 및 치료에 적용하고자한다. 스캔 데이터를 3차원 CT영상인 MIP, 볼륨렌더링, curve multiplanar reformation (MPR), virtual endoscopy 영상을 획득하였다. CT검사 환자의 데이터를 3D 프로그램으로 전송한 영상에서 3D 프로그램에서 측정한 상행대동맥은 364.28 HU, 좌총경동맥 413.77 HU, 좌쇄골하동맥 15.72 HU로 낮게 산출되었다. MIP coronal 영상으로 좌측의 쇄골하동맥의 혈전으로 폐쇄를 정확하게 보여주고 있다. 볼륨렌더링 3차원 영상으로 투과도 100%, 87-1265 HU를 적용하여 쇄골하동맥과 뼈를 동시에 묘출하고 있으며, 좌측 쇄골하동맥의 폐쇄 영상을 선명하게 보여주었으며 coronal curved MPR 및 sagittal curved MPR 영상으로 혈전의 의한 쇄골하동맥의 폐쇄를 3D 영상 처리 기능을 이용하여 정확하게 묘출하고 있다. 혈전에 의한 쇄골하동맥 폐쇄 증상 환자를 MDCT로 스캔하여 3D 영상 기법을 응용하여 쇄골하동맥의 폐쇄를 확인할 수 있어 임상에서 3D 기법을 응용하여 적절하게 진단에 적용할 수 있다.

진폐 정밀/요양기관과 요양기관의 흉부 방사선분야 정도관리 비교 (Comparison of Quality Control for Chest Radiography between Special Examination and Medical Institution for Pneumoconiosis)

  • 이원정
    • 한국콘텐츠학회논문지
    • /
    • 제11권2호
    • /
    • pp.322-330
    • /
    • 2011
  • 전국 33개 진폐요양기관 흉부 방사선분야 정도관리 실태조사를 실시하여 정밀/요양기관(17개)과 요양기관(16개)에 대해 산업안전보건연구원 진폐정도관리 평가표를 이용하여 촬영기술, 판독환경 및 화질평가 결과를 비교 분석하였다. 촬영기술과 판독환경은 연구자가 직접방문하여 평가하였고, 화질평가는 각 진폐 요양기관에서 보내온 영상을 기관마다 10장씩 무작위추출하여 2명의 흉부 영상의학과 전문의가 영상에 대한 어떤 정보도 모르는 상태에서 개별적으로 실시하였다. 정밀/요양기관과 요양기관 사이, 흉부 방사선 촬영 장치의 성능, 사용기간, 촬영방법에서는 유의한 차이가 없었지만, 단순 흉부 촬영조건에서 관전압과 그리드 비에서 유의한 차이가 있었다. 또한, 촬영기술과 판독환경평가에서는 정밀/요양기관이 요양기관 보다 유의하게 높았고, 화질평가에서도 높았지만 유의한 차이는 없었다. 따라서, 진폐합병증이 있는 요양환자의 신뢰성있고 정확한 진단을 위해서는 요양기관의 흉부 방사선분야 정도관리 향상을 위한 외부평가 및 교육이 필요하다.

절단면 재렌더링 기법을 이용한 GPU 기반 MIP 볼륨 렌더링 (GPU based Maximum Intensity Projection using Clipping Plane Re-rendering Method)

  • 홍인실;계희원;신영길
    • 한국멀티미디어학회논문지
    • /
    • 제10권3호
    • /
    • pp.316-324
    • /
    • 2007
  • 의료영상에서 사용하는 MIP 볼륨 렌더링은 CT나 MR 등의 볼륨데이터에서 시각 광선으로부터 높은 밝기 값을 추출하여 혈관과 뼈와 같은 환자의 조직을 보여주는 볼륨 렌더링 기법이다. 최근 GPU를 MIP 볼륨 렌더링에 사용하여 대용량 의료영상 데이터에 대해서도 속도가 빠른 렌더링이 가능하게 되었다. 볼륨데이터를 여러 각도에서 관찰하면, 일반적으로 시각과 동일한 방향의 텍스쳐 평면과 볼륨 경계평면이 비스듬하게 교차한다. 볼륨데이터의 외부에는 값이 존재하지 않으므로 경계부분에서 공간 주파수가 높게 나타난다. 기존의 MIP 렌더링은 샘플링 간격이 일정하기 때문에 경계부분에서 데이터의 손실이 생겨 알리아싱이 나타나는 문제가 있다. 화질을 개선하기 위해 샘플링 간격을 줄여 슬라이스수를 증가시킬 수 있으나, 이때는 렌더링 수행 시간이 길어지게 된다. 이 논문에서는 기존 렌더링 결과에 볼륨 경계 평면을 추가로 렌더링하는 방법을 제안한다. 이 방법은 주파수가 높은 경계 부분의 샘플링 간격을 줄여 화질을 향상시킨다. 한편 MIP는 샘플링 순서에 무관하므로 추가된 슬라이스는 기존 렌더링 영상을 손실시키지 않는다. 증가된 슬라이스는 경계부분인 여섯 평면에 불과하므로 렌더링 수행시간에는 거의 영향을 주지 않고 화질을 개선할 수 있다.

  • PDF