To demonstrate the 3D usefulness of MDCT, a 73-year-old male patient with subclavian thrombosis was obtained 3D images of maximum intensity projection (MIP), volume rendering, and multiplanar reformation (MPR) to clearly detect and locate the subclavian artery. The data will be provided to the patient for diagnosis and treatment. The scan data were acquired as 3D CT images MIP, volume rendering, curved MPR, and virtual endoscopy images. In the 3D program, the ascending aorta was measured as 364.28 HU, the left carotid artery was 413.77 HU, and the left subclavian artery was 15.72 HU. MIP coronal image shows the closure of the subclavian artery in the left side. Three-dimensional volume images were obtained with 100% permeability and 87-1265 HU. The coronal curved MPR and sagittal curved MPR images show the closure of the subclavian artery due to thrombus using 3D image processing. In the case of subclavian arterial occlusion due to thrombosis, the patient is scanned with MDCT and 3D image processing can be used to confirm occlusion of subclavian artery.
Keywords
Angiography; Computed tomography; MIP; 3D image; Subclavian artery; Thrombosis;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 M. F. Fillinger, R. K. Greenberg, J. F. McKinsey, E. L. Chaikof, Society for Vascular Surgery Ad Hoc Committee on TEVAR Reporting Standards, "Reporting standards for thoracic endovascular aortic repair (TEVAR)," Journal of Vascular Surgery, Vol. 52, No. 4, pp. 1022-1033, 2010.   DOI
2 M. D'Addato, L. Pedrini, "Non-cardiac causes of acute ischemia in the arms," Journal of Maladies Vascularies, Vol. 21, No. 5, pp. 303-307, 1996.
3 I. K. Indrajit, J. D. Souza, V. S. Bedi, R. Pant, "Impact of multidetector CT on 3D CT angiography," Medical Journal Armed Forces India., Vol. 61, No. 4, pp. 360-363, 2005.   DOI
4 P. T. Johnson, E. J. Halpern, B. S. Kuszyk, D. G. Heath DG et al. "Renal artery stenosis: CT angiography-comparison of real-time volume-rendering and maximum intensity projection algorithms," Radiology, Vol. 211, No. 2, pp. 337-343, 1999.   DOI
5 B. A. Urban, L. E. Ratner, E. K. Fishman, "Three dimensional volume-rendered CT angiography of the renal arteries and veins: normal anatomy, variants, and clinical applications," Radiographics, Vol. 21, pp. 373-386, 2001.   DOI
6 J. S. Gong, J. M. Xu, "Role of curved planar reformations using multidetector spiral CT in diagnosis of pancreatic and peripancreatic diseases," World Journal of Gastroenterology, Vol. 10, No. 13, pp. 1943-1947, 2004.   DOI
7 E. Criado, R. Berguer, L. Greenfield, "The spectrum of arterial compression at the thoracic outlet," Journal of Vascular Surgery, Vol. 52, No. 2, pp. 406-411, 2010.   DOI
8 R. Walsh, D. Chowdhury, D. Kholwadwala, "An unusual vascular ring: origin of a ductus arteriosus from an aberrant right subclavian artery in a neonate with tetralogy of Fallot," Images in Paediatric Cardiology, Vol. 12, No. 2, pp. 1-4, 2010.
9 E. Tong, T. Rizvi, K. D. Hagspiel, "Complex aortic arch anomaly: Right aortic arch with aberrant left subclavian artery, fenestrated proximal right and duplicated proximal left vertebral arteries-CT angiography findings and review of the literature," Neuroradiology Journal, Vol. 28, No. 4, pp. 396-403, 2015.   DOI
10 C. S. Jones, F. Verde, P. T. Johnson, E. K. Fishman, "Nontraumatic Subclavian Artery Abnormalities: Spectrum of MDCT Findings," American Journal of Roentgenology, Vol. 207, No. 2, pp. 434-441, 2016.   DOI
11 M. Y. Yoo, S. Park, H. J. Jang, H. Y. Lee, D. C. Kweon, "Comparison of image quality and dose according to the arm positioning in the chest CT," Journal of Korean Society of Radiology, Vol. 8, No. 2. pp. 75-79, 2014.   DOI
12 D. D. Cody, "APM/RSNA Physics Tutorial for Residents: Topics in CT: Image processing in CT," Radiographics, Vol. 22, No. 5, pp. 1255-1268, 2002.   DOI
13 V. L. Gisbert, J. J. Hollerman, A. L. Ney, G. L. Rockswold, E. Ruiz, D. M. Jacobs, M. P. Bubrick, "Incidence and diagnosis of C7-T1 fractures and subluxations in multiple-trauma patients: evaluation of the advanced trauma life support guidelines," Surgery, Vol. 106, No. 4, pp. 708-709, 1989.
14 S. Achenbach, W. Moshage, D. Ropers, K. Bachmann, "Curved multiplanar reconstructions for the evaluation of contrast-enhanced electron beam CT of the coronary arteries," American Journal of Roentgenology, Vol. 170, No. 4, pp. 895-899, 1998.   DOI
15 B. S. Kuzyk, D. G. Health, D. R. Ney, D. A. Bluemke, B. A. Urban, T. P. Chambers, E. K. Eishman, "CT angiography with volume rendering imaging findings," American Journal of Roentgenology, Vol. 165, No. 2, pp. 445-448, 1995.   DOI
16 N. Boas, F. Desmoucelle, V. Bernadet, J. C. Franceschi, "Rare cause of acute ischemia of the right upper extremity: thrombosis of a retroesophageal subclavian artery," Annals Vascular Surgery, Vol. 16, No. 3, pp. 387-390, 2002.   DOI
17 P. A. Smith, D. G. Heath, E. K. Fishman, "Virtual angioscopy using spiral CT and real-time interactive volume rendering techniques," Journal of Computer Assisted Tomography, Vol. 22, No. 2, pp. 212-214, 1998.   DOI