• Title/Summary/Keyword: MIL-STD-810G

Search Result 23, Processing Time 0.023 seconds

Dynamic Analysis of Gimbal Structure System Including Nonlinear Elastic Rubber Vibration Isolator with Shock Acceleration (비선형 탄성 방진 고무부에 충격 가속도를 받는 짐발 구조 시스템의 동적 해석)

  • Lee, Sang Eun;Lee, Tae Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.4
    • /
    • pp.415-422
    • /
    • 2016
  • When shock acceleration is applied to a mechanical system, it may cause malfunctioning and damage to the system. Hence, to prevent these problems when developing a gimbal structure system for observation reconnaissance, the MIL-STD-810G shock standard must be satisfied as a design specification. Rubber vibration isolators are generally assembled on the base of the system in order to reduce the shock transferred from the aircraft. It is difficult to analyze the transient behavior of the system accurately, because rubber has a nonlinear load-deformation curve. To treat the nonlinear characteristic of the rubber, bilinear approximation was introduced. Using this assumption, transient responses of the system under base shock acceleration were calculated by the finite element method. In addition, experiments with a true prototype were performed using the same conditions as the analytical model. Compared with experimental data, the proposed numerical method is useful for the transient analysis of gimbal structure systems, including rubber vibration isolators with nonlinear stiffness and damping.

A Study on Heat-transfer Characteristics the Shelter by Solar-heat Radiant (쉘터의 태양열 복사에 의한 열전달 특성에 관한 연구)

  • Shim, Dong-Hyouk;Noh, Kyung-Ho;Park, Jin-Yong;Lim, Young-Taek
    • Journal of the Korea Society for Simulation
    • /
    • v.27 no.2
    • /
    • pp.25-33
    • /
    • 2018
  • When developing military equipment, it should be designed considering the temperature condition so that the operator can operate in a stable environment. The shelter for storing various military equipments is operated in various environments. The storage temperature and operating requirements of the test equipment and repair accessories shall be $-32^{\circ}C$ to $50^{\circ}C$ and the inside of the shelter shall be designed to meet the storage temperature and operating requirements. In this study, thermal analysis of a 2.5 ton military shelter operating under high temperature and solar heat conditions is performed considering MIL-STD-810G. The thermal analysis was applied by using the concept of heat resistance and heat circuit, and the solar thermal test was performed on the actually manufactured military shelter in order to verify the analysis results.

Random response analysis of Missile Guidance Structure by using Finite Element Method (유한요소 해석을 이용한 Missile Guidance Structure의 Random response analysis)

  • Kim, Jaeki;Nam, Kwangsik;choi, Jinkyu;Choi, Homin;Zhao, Shang;Yeom, Sang Hun;Lee, Seoksoon
    • Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.51-56
    • /
    • 2015
  • In the vibration test, Most of the test specifications is standardized methods of sinusoidal excitation. However, in accordance with the ability of the test equipment progress and developments of electronic technology, methods of random vibration test is standardized in the MIL standard. Therefore, in this study, we tried to analyze Missile Guidance Structure using a finite element analysis with ABAQUS 6.13 that is commercial program. First, Random response analysis is analyzed. Following analyzing the results, we wanted to find the model that is lightweight and resonance does not occur.

A Comparison Analysis on The Vibration Test Standard and The Dynamic Characteristic Test of 9,000 Btu Military Airconditioner Applying Refrigerant R-410A (R-410A 냉매를 적용한 9,000Btu 군용에어컨의 진동시험규격과 동특성시험 비교 분석)

  • Choi, Dong-Seol;Lee, Won-Young;Shin, Young-Hun;Lim, Young-Taik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.519-520
    • /
    • 2010
  • R-410A 냉매를 적용한 9,000 Btu 군용에어컨은 2 1/2톤 쉘터카고 차량에 탑재된 쉘터를 냉, 난방하기 위해 사용된다. 이 에어컨은 차량에 탑재된 쉘터의 벽면에 설치되기 때문에 차량 이동 중의 진동, 충격 환경에서 그 기능이 유지되어야 하며, 이에 대한 진동시험을 실시한다. 진동시험은 MIL-STD-810G, 514.5C-VII Composite Wheeled Vehicle 규격에 따라 수행하며, 동특성시험을 통해 확보된 입력 진동값을 진동 규격과 비교하여 적합성을 판단한다.

  • PDF

Stability Analysis of an Mounting Equipment for External Pod on Aircraft by Road Test (항공기 외장형 포드 장착장비의 주행 안정성 분석)

  • Lee, Jong-Hak;Jang, Jong-Youn;Kang, Young-Sik;Choi, Ji-Ho;Kang, Dong-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.10a
    • /
    • pp.424-429
    • /
    • 2013
  • The trolley carrying the pod moves along by the airfield runway. The pod through the trolley are subjected to vibration arising from the ground state, the precision optical components in the pod can have a significant impact. The road tests were conducted by using the measurement pod to remove the risk for the project. The measurement pod was composed with the ACRA, sensors, battery. The accelerometers were attached to get the acceleration through the road condition. The PSD envelop was calculated by FFT from the acceleration. The driving safety was proven through comparing the measurement data and MIL-STD-810G specification.

  • PDF

The Study on the Vehicle-Mounted Radar System of Structural Design Under Environment Conditions (차량 탑재형 레이더 시스템의 구조물에 대한 연구)

  • Jung, Hwa Young;Lee, Keon Min;Kang, Kwang Hee;Kang, Jong Goo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.33 no.10
    • /
    • pp.797-804
    • /
    • 2016
  • The vehicle-mounted radar system (VMRS) including its electronic parts must be designed so that its performance is maintained under varying environmental conditions. The important aspects are typically weight and safety. Since many rotating VMRSs have been developed, discussion about the vibration and shock requirements for the transportation conditions has occurred: in addition, the dynamic unpaved, paved, and off-road effects have been emphasized with respect to lightweight designs. A lightweight-design VMRS should be capable of operating stably under the wind condition with the support of the vehicle structure. In this paper, a structural analysis regarding the support of the VMRS is performed, whereby the real-load conditions for three types of road and pressure were employed in terms of the wind condition. The structural analysis for the safety of the VMRS is performed, and the structural-integrity analytical processes of the VMRS are presented for different load conditions.

Shock Analysis of Gimbal Structure System Including Rubber Vibration Isolator in a Observation Reconnaissance Aircraft (방진 고무를 포함한 항공 감시 정찰용 짐발 구조 시스템의 충격 해석)

  • Lee, Sang Eun;Lee, Tae Won;Kang, Yong Goo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.73-80
    • /
    • 2014
  • A camera module that gathers visual information via aerial observation reconnaissance is equipped inside a gimbal structure. This gimbal structure system must reduce dynamic responses in order to obtain clear images under all circumstances. Among many design specifications for this system, there is MIL-STD-810G as a shock standard. This specification indicates a limitation of the acceleration of the camera module under a base shock excitation on the gimbal structure. The satisfaction of this condition can usually be proved by experiment, because it includes bearings and dynamic isolators made of rubber. Numerical analysis must be proposed for design improvement of the gimbal structure. To achieve this goal, transient response analysis for the base shock excitation was performed using the finite element method. Experimental results were compared with numerical solutions and it is shown that the present method is useful.

Explosion Shock Measurement System of the Precursor Warhead for the Tandem Projectile (탠덤 비행체의 선구탄두 기폭 충격 측정 시스템 구현)

  • Choi, Donghyuk;An, Jiyeon;Kim, Yubeom;Son, Joongtak;Lee, Ukjun;Park, Hyunsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.5
    • /
    • pp.503-510
    • /
    • 2021
  • This paper presents a system that measures the acceleration of the shock caused by the explosion of the precursor warhead for the tandem projectile. The proposed system, which is implemented based on the MIL-STD-810G, Method 517.1, consists of a miniaturized shock measurement device, a cable, accelerometers, and a trigger circuit. The shock measurement device has a size of ¢102 × 171 mm and cable has a length of 3 m. The operational confirmation test is conducted by implementing the measurement system. The Analysis of shock data(accelerometer output data) is carried out using Shock Response Spectrum(SRS), pseudo velocity and plot of acceleration time transient. Through measurement analysis, one can predict the damage of electronics in projectile when precursor warhead is exploded.

Design Method of Internal Structure Based on Dynamic Characteristic Analysis of 2.5ton Military Vehicle (2.5톤 군용차량 동특성 분석에 따른 내부구조물 설계 방안)

  • Yang, Ina;Choi, Wookyun;Jung, Kyongwook;Shim, Donghyouk;Son, Donghyeop
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Electronic equipment mounted on military vehicles is exposed to external shocks and vibrations. This causes problems in tactical operation and also causes cost loss in equipment maintenance. Therefore, to optimize the test standards for military vehicles with vibration, dynamic characteristics should be analyzed and standardized through actual driving tests. In this paper, the internal structure of 2.5tons military vehicle is designed in the form of a drawer and lathe, and the dynamic characteristics are identified by experiment, and the design is proposed.

Developement of Multifunction PCM Recorder for Telemetry System (원격측정용 다기능 PCM 데이터 저장장치 개발)

  • Daeyeon Kim;Jaemin Kim;Kwang-Ryul Koh;Sang-Bum Lee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.171-178
    • /
    • 2023
  • PCM data is result of air-vehicle flight test, this data is distributed for each engineers to analyze its condition. Since line-of-sight between the air-vehicle and the ground receiver cannot always be secured, remote PCM data recording system was claimed to be required. In this paper multi-function PCM data recorder has been described. This PCM data recorder was intended to place on inside of flight object. It can record about two hours in 32 GB SD card with maximum 7 Mbps data rate. RS-422/485 and RJ-45 interface enhanced accessibility for users. 5 V and 1 A power consumption and 19.5 mm × 152.5 mm × 102.3 mm allow to connect with mobile PCM devices. It acquired more than 190-minutes data in 12-times flight test. Also, it achieved military standard environmental test MIL-STD-810G to prove its stability and solidness.