• Title/Summary/Keyword: MEMS(Microelectromechanical system)

Search Result 55, Processing Time 0.027 seconds

Applications of MEMS Technology on Medicine & Biology (의료 및 생물학에 응용되는 MEMS기술)

  • Chang, J.K.;Chung, S.;Han, D.C.
    • Transactions of Materials Processing
    • /
    • v.11 no.2
    • /
    • pp.108-113
    • /
    • 2002
  • The application fields of medicine and biology are spotlighted because of the increasing concentration of health and the abundance of life. MEMS is very good solution in this fields for the concept of point of care which makes systems more useful and spread wide. This paper shows the major fabrication schemes and application fields of microelectromechanical system specially in medicine and biology fields.

Stress Analysis Using Finite Element Modeling of a Novel RF Microelectromechanical System Shunt Switch Designed on Quartz Substrate for Low-voltage Applications

  • Singh, Tejinder;Khaira, Navjot K.;Sengar, Jitendra S.
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.5
    • /
    • pp.225-230
    • /
    • 2013
  • This paper presents a novel shunt radio frequency microelectromechanical system switch on a quartz substrate with stiff ribs around the membrane. The buckling effects in the switch membrane and stiction problem are the primary concerns with RF MEMS switches. These effects can be reduced by the proposed design approach due to the stiffness of the ribs around the membrane. A lower mass of the beam and a reduction in the squeeze film damping is achieved due to the slots and holes in the membrane, which further aid in attaining high switching speeds. The proposed switch is optimized to operate in the k-band, which results in a high isolation of -40 dB and low insertion loss of -0.047 dB at 21 GHz, with a low actuation voltage of only 14.6 V needed for the operation the switch. The membrane does not bend with this membrane design approach. Finite element modeling is used to analyze the stress and pull-in voltage.

Method of Ga removal from a specimen on a microelectromechanical system-based chip for in-situ transmission electron microscopy

  • Yena Kwon;Byeong-Seon An;Yeon-Ju Shin;Cheol-Woong Yang
    • Applied Microscopy
    • /
    • v.50
    • /
    • pp.22.1-22.6
    • /
    • 2020
  • In-situ transmission electron microscopy (TEM) holders that employ a chip-type specimen stage have been widely utilized in recent years. The specimen on the microelectromechanical system (MEMS)-based chip is commonly prepared by focused ion beam (FIB) milling and ex-situ lift-out (EXLO). However, the FIB-milled thin-foil specimens are inevitably contaminated with Ga+ ions. When these specimens are heated for real time observation, the Ga+ ions influence the reaction or aggregate in the protection layer. An effective method of removing the Ga residue by Ar+ ion milling within FIB system was explored in this study. However, the Ga residue remained in the thin-foil specimen that was extracted by EXLO from the trench after the conduct of Ar+ ion milling. To address this drawback, the thin-foil specimen was attached to an FIB lift-out grid, subjected to Ar+ ion milling, and subsequently transferred to an MEMS-based chip by EXLO. The removal of the Ga residue was confirmed by energy dispersive spectroscopy.

Effective Stress Modeling of Membranes Made of Gold and Aluminum Materials Used in Radio-Frequency Microelectromechanical System Switches

  • Singh, Tejinder
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.4
    • /
    • pp.172-176
    • /
    • 2013
  • Microelectromechanical system switches are becoming more and more popular in the electronics industry; there is a need for careful selection of the materials in the design and fabrication of switches for reliability and performance issues. The membrane used for actuation to change the state of an RF switch is made mostly using gold or aluminum. Various designs of membranes have been proposed. Due to the flexure-type structures, the design complexity increases, which makes stress analysis mandatory to validate the reliability and performance of a switch. In this paper, the effective stress and actuation voltage required for different types of fixed-fixed membranes is analyzed using finite element modeling. Effective measures are presented to reduce the stress and voltage.

An ASIC implementation of a Dual Channel Acoustic Beamforming for MEMS microphone in 0.18㎛ CMOS technology (0.18㎛ CMOS 공정을 이용한 MEMS 마이크로폰용 이중 채널 음성 빔포밍 ASIC 설계)

  • Jang, Young-Jong;Lee, Jea-Hack;Kim, Dong-Sun;Hwang, Tae-ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.949-958
    • /
    • 2018
  • A voice recognition control system is a system for controlling a peripheral device by recognizing a voice. Recently, a voice recognition control system have been applied not only to smart devices but also to various environments ranging from IoT(: Internet of Things), robots, and vehicles. In such a voice recognition control system, the recognition rate is lowered due to the ambient noise in addition to the voice of the user. In this paper, we propose a dual channel acoustic beamforming hardware architecture for MEMS(: Microelectromechanical Systems) microphones to eliminate ambient noise in addition to user's voice. And the proposed hardware architecture is designed as ASIC(: Application-Specific Integrated Circuit) using TowerJazz $0.18{\mu}m$ CMOS(: Complementary Metal-Oxide Semiconductor) technology. The designed dual channel acoustic beamforming ASIC has a die size of $48mm^2$, and the directivity index of the user's voice were measured to be 4.233㏈.

마이크로 기술을 이용한 심장세포칩

  • Park, Jeong-Yeol
    • Journal of the KSME
    • /
    • v.50 no.11
    • /
    • pp.43-46
    • /
    • 2010
  • 이글에서는 마이크로 기술, 특히 Microelectromechanical System(MEMS) 기술을 활용하여 심장세포의 기계적/물리적 특성 분석을 위한 심장세포용 바이오센서 및 심장세포의 기계적 힘을 이용한 심장세포 기반의 바이오 하이브리드(biohybrid) 디바이스에 대하여 소개하고자 한다.

  • PDF

탄소나노튜브와 멤스 소자의 융합

  • Choe, Jeong-Uk;Kim, Jong-Baek
    • Journal of the KSME
    • /
    • v.53 no.9
    • /
    • pp.41-45
    • /
    • 2013
  • 이 글에서는 탄소나노튜브와 멤스(MEMS: Microelectromechanical system) 소자의 융합 기술 및 응용 분야에 대하여 소개하고자 한다.

  • PDF

Novel graphene-based optical MEMS accelerometer dependent on intensity modulation

  • Ahmadian, Mehdi;Jafari, Kian;Sharifi, Mohammad Javad
    • ETRI Journal
    • /
    • v.40 no.6
    • /
    • pp.794-801
    • /
    • 2018
  • This paper proposes a novel graphene-based optical microelectromechanical systems MEMS accelerometer that is dependent on the intensity modulation and optical properties of graphene. The designed sensing system includes a multilayer graphene finger, a laser diode (LD) light source, a photodiode, and integrated optical waveguides. The proposed accelerometer provides several advantages, such as negligible cross-axis sensitivity, appropriate linearity behavior in the operation range, a relatively broad measurement range, and a significantly wider bandwidth when compared with other important contributions in the literature. Furthermore, the functional characteristics of the proposed device are designed analytically, and are then confirmed using numerical methods. Based on the simulation results, the functional characteristics are as follows: a mechanical sensitivity of 1,019 nm/g, an optical sensitivity of 145.7 %/g, a resonance frequency of 15,553 Hz, a bandwidth of 7 kHz, and a measurement range of ${\pm}10g$. Owing to the obtained functional characteristics, the proposed device is suitable for several applications in which high sensitivity and wide bandwidth are required simultaneously.

A Study on Implementation of Automatic Evaluation System for Static Performance of 6 DOF MEMS Inertial Sensor (6자유도 MEMS 관성센서 정적성능 자동 평가 시스템 구현에 관한 연구)

  • Ji Won Park;Hussamud Din;Byeung Leul Lee
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.3
    • /
    • pp.62-66
    • /
    • 2023
  • With the advancement in technology and rapid increase in the demand for microelectromechanical systems (MEMS) based inertial measurement units (IMUs), high-volume production and test system remain a major challenge for the MEMS industry. To compete with the challenging market of Industry 4.0, here we developed an automatic test system to evaluate the performance of the ovenized IMU sensors as well as analyze the data. The automatic test system was developed by interfacing a commercial MEMS IMU (BMI 088) using LabVIEW. The BMI 088 was tested experimentally for long-term bias stability, ON/OFF bias repeatability, and root mean square (rms) noise. Furthermore, the data was analyzed through the developed test system. The results show that the automatic test system has improved the test time and reduced human effort. The developed automatic test system is a significant approach to MEMS research and development (R&D) to increase and improve the mass production of IMUs.

  • PDF

Applications of MEMS-MOSFET Hybrid Switches to Power Management Circuits for Energy Harvesting Systems

  • Song, Sang-Hun;Kang, Sungmuk;Park, Kyungjin;Shin, Seunghwan;Kim, Hoseong
    • Journal of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.954-959
    • /
    • 2012
  • A hybrid switch that uses a microelectromechanical system (MEMS) switch as a gate driver of a MOSFET is applied to an energy harvesting system. The power management circuit adopting the hybrid switch provides ultralow leakage, self-referencing, and high current handling capability. Measurements show that solar energy harvester circuit utilizing the MEMS-MOSFET hybrid switch accumulates energy and charges a battery or drive a resistive load without any constant power supply and reference voltage. The leakage current during energy accumulation is less than 10 pA. The power management circuit adopting the proposed hybrid switch is believed to be an ideal solution to self-powered wireless sensor nodes in smart grid systems.