• Title/Summary/Keyword: M-way below

Search Result 69, Processing Time 0.025 seconds

An Experimental Study on Shielding Apparatus for the Impulse Noise of K2 Rifle (K2소총의 사격음 차폐장치에 관한 실험적 연구)

  • Lee, Jin-Ho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.486-492
    • /
    • 2010
  • This paper studies an experimental analysis of the impulse noise of K2 rifle when its bullet passes through the large tube(length 1.84m, outer diameter 50cm, glass wool & steel). In experiment, the characteristics of the sound of shooting were different according to the way of shooting; the results of the experiment are given below. First of all, the shooting sound was lower in single-shot shooting, when compared to 3rds burst-shot shooting, difference averaging 2.8dB, 4.0dB at maximum. In short, the difference is minuscule. Secondly, the sound of the K2 rifle was diminished when shot in a tube, ranging from 2.7dB to 15.4dB, averaging 8.2dB. Thirdly, the shooting sound of the K2 rifle was diminished as the insertion depth deepened with formulas given in Fig. 5, 6. Fourthly, basic data for excluding sound of the shooting were presented. Lastly, the characteristics of the shooting sound could be equally used as a basic material for developing marksmanship and sharp-shooting detection device.

An Experimental Study on the Condensation Characteristics of Sea Water in the Tilted Box with Solar Radiation (태양열을 받는 경사진 육면체 내 해수의 응축특성에 관한 실험적 연구)

  • Kim, Beom-Han;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.27-33
    • /
    • 2011
  • To find effective way of the production of distilled water for drought and flood with solar radiation, three boxes were made same base each 1000mm ${\times} $1000mm and tops are 45 degree. Individual boxes contained the sea water, rain water and surface water were placed at the same location and same time. Condensation of each box has been compared. On clear day production of distilled water in the box with sea water was 36% and 32% less than boxes with rain water and surface water. The maximum condensation reached when the temperature of the top and bottom parts are equal. As concentration of sea water increased production of distilled water was decreased. In the box with sea water, the surface temperature was lower than 3cm below the surface. Optimum collector area for producing distilled water 2000ml of these three boxes were $3.75m^2$

Concentration Variations in Primary and Secondary Particulate Matter near a Major Road in Korea

  • Ghim, Young Sung;Won, Soo Ran;Choi, Yongjoo;Chang, Young-Soo;Jin, Hyoun Cher;Kim, Yong Pyo;Kang, Chang-Hee
    • Asian Journal of Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.32-41
    • /
    • 2016
  • Particle-phase concentrations were measured at 10, 80, and 200 m from the roadside of a national highway near Seoul in January and May 2008. The highway has two lanes each way, with an average hourly traffic volume of 1,070 vehicles. In January 2008, $PM_{10}$ concentrations decreased from 10 to 80 m but increased at 200 m. Black carbon (BC) decreased only slightly with distance due to the influence of biomass burning and open burning from the surrounding areas. In May 2008, the effect of secondary formation on both $PM_{10}$ and $PM_{2.5}$ was significant due to high temperatures compared with January. Because on-road emissions had little effect on secondary formation for a short time, variations in $PM_{10}$ concentrations became smaller, and $PM_{2.5}$ concentrations increased with distance. The effects of fugitive dust on PM concentrations were greater in May than in January when the mean temperature was below freezing. In the composition variations, the amounts of primary ions, organic carbon (OC), and BC were larger in January, while those of secondary ions and others were larger in $PM_{10}$, as well as $PM_{2.5}$ in May.

Best Management Practices Reducing Soil Loss in the Saprolite Piled Upland in Hongcheon Highland (고령지 석비레 성토 밭의 토양유실 저감을 위한 최적영농관리방안)

  • Park, Chol-Soo;Jung, Yeong-Sang;Joo, Jin-Ho;Lee, Jung-Tae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.3
    • /
    • pp.119-126
    • /
    • 2005
  • Soil erosion at Jawoon-Ri in Hongcheon highland is one of serious problems since saprolite piling on farmland has been typically practiced at 2-3 year's intervals. The objective of the case study was to survey management practices such as tillage, application of saprolite, and cultivating crops and to propose best management practices (BMP) to reduce soil loss in Jawoon-Ri, Hongcheon-Gun. Jawoon-Ri is located in the upper stream of Naerinchun. Upland areas of Jawoon 2 and 4Ri were 206.9 and 142.3 hectare, respectively. Estimation of soil loss in this study was based on USLE (Universal soil loss equation). Annual averaged soil losses were 15.6 MT per hectare in Jawoon-2Ri and 9.0 MT per hectare in Jawoon-4Ri, respectively. This case study tried to find methods to reduce soil erosion below tolerant soil loss level which is $11MT\;ha^{-1}\;yr^{-1}$. Estimated soil losses in more than 40% of uplands in Jawoon-2Ri and 4Ri were higher than tolerant soil loss level. Especially, edge of uplands undergone excessive soil erosion by concentrated runoff water. Therefore consolidation of upland edge was included as one of the proposed Best management practices BMP). The proposed BMP in this area were buffer strips, contour and mulching, diversion drain channel, grassed water-way, detour watet-way and cover crops and so on. Amounts for BMP requirements were 7,680 m for buffer strips, 123 ha (35%) for contour and mulching, 201 ha (57%) for diversion drain channel, 13,880 m for grassed water-way, 3,860 m for detour drainage, 8,365 m for sloping side consolidation and 3,492 ha for cover crops, respectively. Application of BMP are urgently needed in uplands which is direct conjunction with stream.

Study on the Treesize Prediction Model : A case study of Zelkova serrata, Pinus strobus and Magnolia denudata (주요조경수목의 크기 예측 " 모델 "에 관한 연구 : 느티나무, 스트로브잣나무, 백목련을 대상으로)

  • 김남춘;최준수;문석기
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.16 no.1
    • /
    • pp.27-35
    • /
    • 1988
  • Size characteristics of three widely used landscape trees were analized to establish a methodology of size prediction as time Passes. Tree height, tree width, stem diameter(breast or surface), canopy length and tree age were measured directly and indirectly(by using photograph), and the data were analized by using regression analysis through PC-SAS. The results are summarized as follows : 1. Zelkova serrata MAKINO showed relatively slow growth rate and the tree form was changed as aged. Size predictions were available by using the regression equations listed below : Surface diameter = 0.8293 x AGE Tree height = 0.4109(0.8293 x AGE) - 0.0039(0.7273 x AGE)$^2$Tree width = 0.3240(0.8293 x AGE) - 0.0024(0.1293 x AGE)$^2$Canopy length = 0.1337(0.8293 x AGE) - 0.0020(0.7293 x AGE)$^2$2. Pinus strobus L. showed relatively fast growth rate and the tree form did not change much as aged. Size predictions were available by using the regression equations listed below. Breast diameter = 0.756 x AGE Tree height = 0.7695(0.756 x AGE) - 0.0164(0.75\ulcorner x AGE)$^2$Tree width = 0.4331(0.756 x AGE) - 0.0079(0.75\ulcorner x AGE)$^2$Canopy length = 0.1365(0.756 x AGE) - 0.0032(0.75f x AGE)$^2$ 3. In case of Magnolia denudata DESROUX, tree form was determined relatively earlier than the other two species. Si2e predictions were available by using the regression equations listed below : Surface diameter = 0.88 x AGE Tree height = 0.5412(0.88 x AGE) - 0.0110(0.88 x AGE)$^2$ Tree width = 0.3752(0.88 x AGE) - 7.0061(0.88 x AGE)$^2$Canopy length = 0.1110(0.88 x AGE) - 0.0022(0.88 x AGE)$^2$ This study aimed to find a way to predict size change of landscaping plants. This methodology will be applied to a wide range of landscape plants to provide practical data to landscape designers.

  • PDF

A Study on the Change of Exclusive Space for Balcony Expansion in an Apartment - Focused on an Apartment House below 85m2 of Exclusive Area- (아파트 발코니 확장에 따른 전용공간의 변화에 관한 연구 - 전용면적 85m2형 공동주택을 대상으로 -)

  • Bae, Dong-Sig
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.2
    • /
    • pp.11-18
    • /
    • 2018
  • The purpose of this study is to analyze the structure and use change of the private space according to the balcony expansion and use it as the data of plan design. According to Bay, front length/width ratio and the change of balcony space before and after expansion of space organization of house units were analyzed. Common characteristics of Flat type and Tower type are an increase of the frontage length of house units in an apartment, an increase of the number of front bay, and an increase of integrated LDK focusing on living room. A difference is that Flat type shows high frontage ratio, Bay figure, and spatial arrangement favorable to front openness and lighting. Flat type shows higher area distribution than Tower type in LDK area distribution located in at the plane center. Spatial expandability and visual openness of Flat type are more beneficial than those of Tower type in the planning, and a balcony extension of house units has developed to direction to open more. Tower type creates various block images through a combination of house units focusing on the core. Uses after balcony expansion are area expansion of a balcony-neighboring room, storage space, expansion and function improvement of the variable range, and specialized space different from a neighboring room. In addition, there is no escapable space except for a shelter, so unit plan should be prepared to prevent using it other space of a shelter and to solve moving line of two-way horizontal refuge and vertical refuge.

Relationship between battery level and irradiance of light-curing units and their effects on the hardness of a bulk-fill composite resin

  • Fernanda Harumi Oku Prochnow ;Patricia Valeria Manozzo Kunz;Gisele Maria Correr;Marina da Rosa Kaizer;Carla Castiglia Gonzaga
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.4
    • /
    • pp.45.1-45.10
    • /
    • 2022
  • Objectives: This study evaluated the relationship between the battery charge level and irradiance of light-emitting diode (LED) light-curing units (LCUs) and how these variables influence the Vickers hardness number (VHN) of a bulk-fill resin. Materials and Methods: Four LCUs were evaluated: Radii Plus (SDI), Radii-cal (SDI), Elipar Deep Cure (Filtek Bulk Fill, 3M Oral Care), and Poly Wireless (Kavo Kerr). Irradiance was measured using a radiometer every ten 20-second activations until the battery was discharged. Disks (4 mm thick) of a bulk-fill resin (Filtek Bulk Fill, 3M Oral Care) were prepared, and the VHN was determined on the top and bottom surfaces when light-cured with the LCUs with battery levels at 100%, 50% and 10%. Data were analyzed by 2-way analysis of variance, the Tukey's test, and Pearson correlations (α = 5%). Results: Elipar Deep Cure and Poly Wireless showed significant differences between the irradiance when the battery was fully charged versus discharged (10% battery level). Significant differences in irradiance were detected among all LCUs, within each battery condition tested. Hardness ratios below 80% were obtained for Radii-cal (10% battery level) and for Poly Wireless (50% and 10% battery levels). The battery level showed moderate and strong, but non-significant, positive correlations with the VHN and irradiance. Conclusions: Although the irradiance was different among LCUs, it decreased in half of the devices along with a reduction in battery level. In addition, the composite resin effectiveness of curing, measured by the hardness ratio, was reduced when the LCUs' battery was discharged.

Dynamic analysis of slack moored spar platform with 5 MW wind turbine

  • Seebai, T.;Sundaravadivelu, R.
    • Ocean Systems Engineering
    • /
    • v.1 no.4
    • /
    • pp.285-296
    • /
    • 2011
  • Spar platforms have several advantages for deploying wind turbines in offshore for depth beyond 120 m. The merit of spar platform is large range of topside payloads, favourable motions compared to other floating structures and minimum hull/deck interface. The main objective of this paper is to present the response analysis of the slack moored spar platform supporting 5MW wind turbine with bottom keel plates in regular and random waves, studied experimentally and numerically. A 1:100 scale model of the spar with sparD, sparCD and sparSD configuration was studied in the wave basin ($30{\times}30{\times}3m$) in Ocean engineering department in IIT Madras. In present study the effect of wind loading, blade dynamics and control, and tower elasticity are not considered. This paper presents the details of the studies carried out on a 16 m diameter and 100 m long spar buoy supporting a 90 m tall 5 MW wind turbine with 3600 kN weight of Nacelle and Rotor and 3500 kN weight of tower. The weight of the ballast and the draft of the spar are adjusted in such a way to keep the centre of gravity below the centre of buoyancy. The mooring lines are divided into four groups, each of which has four lines. The studies were carried out in regular and random waves. The operational significant wave height of 2.5 m and 10 s wave period and survival significant wave height of 6 m and 18 s wave period in 300 m water depth are considered. The wind speed corresponding to the operational wave height is about 22 knots and this wind speed is considered to be operating wind speed for turbines. The heave and surge accelerations at the top of spar platform were measured and are used for calculating the response. The geometric modeling of spar was carried out using Multisurf and this was directly exported to WAMIT for subsequent hydrodynamic and mooring system analysis. The numerical results were compared with experimental results and the comparison was found to be good. Parametric study was carried out to find out the effect of shape, size and spacing of keel plate and from the results obtained from present work ,it is recommended to use circular keel plate instead of square plate.

Analysis of Density Current in the Tidal River (감조하천(感潮河川)의 하구(河口) 밀도류해석(密度流解析))

  • Suh, Seung Duk;Park, Sung Bae
    • Current Research on Agriculture and Life Sciences
    • /
    • v.4
    • /
    • pp.70-76
    • /
    • 1986
  • The purpose of this study is to offer the basic data of the tidal river development program by grasping the diffusion between the high density-sea water and the low density-fresh water in the tidal river. The tidal range of Hyungsan river which flows at Youngil bay in Pohang was selected to analysis the phenomenon of density current. The results obtained are as follows ; The tide of Youngil bay was one time a day, 0.104m in high tide difference and 0.085m in mean tidy difference. The change of sea level by tide was negligible. The volume of reserved water by sea water was $2,700,000m^3$ and available water of irrigation was $1,200,000m^3$ that salt density is below $750{\mu}{\mho}/cm$ out of total volume. Salt intrusion phenomenon by density current was a little water level change, however, it become a salt wedge type by the much salt invasion during the spring tide and it makes a well-mixed type by the retreating salt wedge during the neap tide. As long as there were some density differences between sea water and fresh water, net upstream flow was existed along the bottom of water way from the estuary to the upstream channel.

  • PDF

Characteristics of Hazardous Volatile Organic Compounds (HVOCs) at Roadside, Tunnel and Residential Area in Seoul, Korea (서울시 도로변, 터널 및 주거지역 대기 중 유해 휘발성 유기화합물의 특성)

  • Lee, Je-Seung;Choi, Yu-Ri;Kim, Hyun-Soo;Eo, Soo-Mi;Kim, Min-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.558-568
    • /
    • 2011
  • Hazardous volatile organic compounds (HVOCs) have been increasingly getting concern in urban air chemistry due to photochemical smog as well as its toxicity or potential hazards. In this study, we investigated their concentrations and the properties in tunnel, urban roadside and residential area. As a result, among 36HVOCs measured in this study, BTEX (benzene, toluene, ethylbenzene, xylene) and dichlorodifluoromethane, 1,2,4-trimethylbenzene, trichlorofluoromethane were detected above the concentration of $1{\mu}g/m^3$ in every sampling site and the most abundant compound was toluene. The other compounds were detected at trace level or below the detection limit. In addition, we found that three CFCs (chlorofluorocarbons), such as CFC-12, CFC-11, CFC-113, were persistently detected because of the emission in the past. Toluene to benzene ratio (T/B) at tunnel and roadside were calculated to be 4.3~5.3 and at residential area 15.4, suggesting that the residential area had several emission sources other than car exhaust. The ratio of X/E (m,p-xylene to ethylbenzene) ratio was calculated to be 1.8~2.1 at tunnel, 1.7 at roadside and 1.2 at residential area, which means this ratio reflected well the relative photochemical reactivity between these compounds. Good correlation between m,p-xylene and ethylbenzene ($r^2$ > 0.85) were shown in every study sites. This indicated that correlation between $C_2$-alkylbenzenes were not severely affected by 3-way catalytic converter. In this study, it was demonstrated that the concentration of benzene was very low, compared with national air quality standard (annual average of $5{\mu}g/m^3$). Its concentration were $2.52{\mu}g/m^3$ in roadside and $1.34{\mu}g/m^3$ in residential area. We thought this was the result of persistent policy implementation including the reduction of benzene content in gasoline enforced on January 1, 2009.