• Title/Summary/Keyword: M-pass

Search Result 738, Processing Time 0.033 seconds

Merits and Demerits of the Inspection System introduced in Construction of City Planning Road: In Case of Crossing Road of the Aioiyama Green Area in Nagoya

  • Yutaka Okamura
    • Journal of the Korean Institute of Landscape Architecture International Edition
    • /
    • no.2
    • /
    • pp.178-184
    • /
    • 2004
  • The Yatomi - Aioiyama line is a city-planning road that was notified in 1957 and subsequently prepared by land readjustments. Currently, approximately 900m of road pass in the inside of the Aioiyama green area has not been constructed. The surveying briefing session for inhabitants was held in July 1992, the project was authorized by the Ministry of Land, Infrastructure and Transport in September 1993, and the project briefing session for inhabitants was held in September 1993. The site purchase has been completed. At the May 2000 briefing session, inhabitants of the area began voicing dissenting demanding the conservation of the natural environment of this green area. The inspector system serves as the third party, independent of both the administration and the inhabitants. Before finalizing the geometric line form of the road to be constructed, some surveys of animals and plants found along the walking trails carried out intensively in the northern area, which is approximately 50 ha, of the Aioiyama green area. The natural environment inspector submitted a plan for changing the geometric line form of the road decided upon by city planning, and it was approved by the city planning council. If the shelter structure or the retaining wall structure is adopted at the location where large slope faces are produced by excavation or landfill, and if the bridge structure is adopted at the place where stream-lines and walking trails intersect, it leads to a reduction of approximately $40\%$ in the areas for which change is planned. Furthermore, approximately $20\%$ of the area to be changed is restored by returning soil to the roof of the shelter.

  • PDF

Characterization of Expressed Sequence Tags (ESTs) Generated from the Bombyx mandarina Whole Larvae and Molecular Cloning of Serine Protease Homologue Gene

  • Hwang, Jae Sam;Yun, Eun Young;Goo, Tae Won;Kim, Iksoo;Choi, Kwang Ho;Seong, Su Il;Kim, Keun Young;Lee, Sang Mong;Kang, Seok Woo
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.9 no.2
    • /
    • pp.167-171
    • /
    • 2004
  • We constructed an oligo-d(T) primed directional cDNA library from the Bombyx mandarina whole larvae. In an effort to isolate genes expressed in the B. mandarina, 227 expressed sequence tags (ESTs) were generated by single-pass sequencing from the cDNA library. Sequence analysis showed that 107 clones (47.1%) were classified into known genes and 120 clones (52.9%) were novel transcripts, which are unknown for their function. Of the 107 known genes, the most abundant gene was found to be actin and followed by serine protease in the expression profile. Among these clones, a serine protease homolog (BmSP) which is a class of proteolytic enzymes isolated. Full-length sequence of the BmSP cDNA clone was 922 bp in length and has an open reading frame of 276 amino acids. The conserved histidine, aspatic acid and serine residues forming the catalytic center as well as cysteine residues contributing to three disulphide bonds also were found in Bmsp gene. mRNA expression analysis revealed a high and specific expression of the gene only in midgut tissue, suggesting that BmSP gene is closely associated with the expression of digestive enzyme.

CDSS enabled PHR system for chronic disease patients (만성 질병환자를 위한 CDSS를 적용한 PHR 시스템)

  • Hussain, Maqbool;Khan, Wajahat Ali;Afzal, Muhammad;Ali, Taqdir;Lee, Sungyoung
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.1321-1322
    • /
    • 2012
  • With the advance of Information Technology (IT) and dynamic requirements, diverse application services have been provided for end users. With huge volume of these services and information, users are required to acquire customized services that provide personalized information and decision at particular extent of time. The case is more appealing in healthcare, where patients wish to have access to their medical record where they have control and provided with recommendation on the medical information. PHR (Personal Health Record) is most prevailing initiative that gives secure access on patient record at anytime and anywhere. PHR should also incorporate decision support to help patients in self-management of their diseases. Available PHR system incorporates basic recommendations based on patient routine data. We have proposed decision support service called "Smart CDSS" that provides recommendations on PHR data for diabetic patients. Smart CDSS follows HL7 vMR (Virtual Medical Record) to help in integration with diverse application including PHR. PHR shares patient data with Smart CDSS through standard interfaces that pass through Adaptability Engine (AE). AE transforms the PHR CCR/CCD (Continuity of Care Record/Document) into standard HL7 vMR format. Smart CDSS produces recommendation on PHR datasets based on diabetic knowledge base represented in shareable HL7 Arden Syntax format. The Smart CDSS service is deployed on public cloud over MS Azure environment and PHR is maintaining on private cloud. The system has been evaluated for recommendation for 100 diabetic patients from Saint's Mary Hospital. The recommendations were compared with physicians' guidelines which complement the self-management of the patient.

Case study of Hexavalent Chromium and Silica Exposure Assessment and Respiratory Fit-test for Paint Manufacturing Worker (페인트 제조 작업자의 6가 크롬 및 실리카 노출평가와 호흡보호구 밀착도 검사 사례)

  • Lee, Hyun Seok;Kim, Boowook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.4
    • /
    • pp.295-303
    • /
    • 2021
  • Objective: Paint manufacturing industry workers are exposed to various lung cancer carcinogenic substances including hexavalent chromium and crystalline silica. Studies have been conducted on lung cancer in Paint manufacturing industry workers and the concentration of hexavalent chromium in paint industry; however, the concentration of crystalline silica and hexavalent chromium and cases of lung cancer in a single Paint factory has never been reported in Korea. Methods: To determine whether the cancer was related to his work environment, we assessed the level of exposure to carcinogens during pouring and mixing talc and pigment. In addition, a mask fit test was performed for the worker. Results: Analysis of talc and silica bulk powder materials showed that crystalline silica (quartz) was 5% in talc and 100% in silica. The green and yellow pigments contained 87% and 92% of lead chromate, respectively. Our quantitative analysis of pigment powder samples showed that the hexavalent chromium contents quantified in the green and yellow pigment samples were 87% and 92%, respectively. In order to estimate his exposure level of hexavalent chromium, we measured a personal exposure level of hexavalent chromium for a worker in accordance with the National Institute for Occupational Safety and Health #7605 method. The results showed that the worker was exposed to the high level of hexavalent chromium (0.033 mg m-3). In addition, the talc powder also contained 5% quartz, and the worker's exposure level to respirable quartz exceeded OEL. As a result of the respiratory protection fit test for workers, the overall Fit Factor was '15' when wearing a second-grade mask and '25' when wearing a first-grade mask, significantly lower than the US Occupational Safety and Health Agency (OSHA) pass value of "100". Conclusion: Workers who pouring and mixing powder materials such as talc or colored pigments in paint manufacturing company may be exposed to high concentrations of carcinogenic substances. These findings indicate that it is necessary to local ventilation system inspection, safety and health education for employers and workers, and periodically monitoring and manage the working environment.

A Study on the Development of Gear Transmission Error Measurement System and Verification (기어 전달오차 계측 시스템 개발 및 검증에 관한 연구)

  • Moon, Seok-Pyo;Lee, Ju-Yeon;Moon, Sang-Gon;Kim, Su-Chul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.12
    • /
    • pp.136-144
    • /
    • 2021
  • The purpose of this study was to develop and verify a precision transmission error measurement system for a gear pair. The transmission error measurement system of the gear pair was developed as a measurement unit, signal processing unit, and signal analysis unit. The angular displacement for calculating the transmission error of the gear pair was measured using an encoder. The signal amplification, interpolation, and transmission error calculation of the measured angular displacement were conducted using a field-programmable gate array (FPGA) and a real-time processor. A high-pass filter (HPF) was applied to the calculated transmission error from the real-time processor. The transmission error measurement test was conducted using a gearbox, including the master gear pair. The same test was repeated three times in the clockwise and counterclockwise directions, respectively, according to the load conditions (0 - 200 N·m). The results of the gear transmission error tests showed similar tendencies, thereby confirming the stability of the system. The measured transmission error was verified by comparing it with the transmission error analyzed using commercial software. The verification showed a slight difference in the transmission error between the methods. In a future study, the measurement and analysis method of the developed precision transmission error measurement system in this study may possibly be used for gear design.

Microstructure and Mechanical Properties of AA6061/AA5052/AA6061 Complex Sheet Fabricated by Cold-Roll Bonding Process (냉간압연접합법에 의해 제조된 AA6061/AA5052/AA6061 복합판재의 미세조직 및 기계적 성질)

  • Hwang, Ju-Yeon;Lee, Seong-Hee
    • Korean Journal of Materials Research
    • /
    • v.29 no.6
    • /
    • pp.392-397
    • /
    • 2019
  • A cold roll-bonding process is applied to fabricate an AA6061/AA5052/AA6061 three-layer clad sheet. Two AA6061 and one AA5052 sheets of 2 mm thickness, 40 mm width, and 300 mm length are stacked, with the AA5052 sheet located in the center. After surface treatment such as degreasing and wire brushing, sample is reduced to a thickness of 1.5 mm by multi-pass cold rolling. The rolling is performed at ambient temperature without lubricant using a 2-high mill with a roll diameter of 400 mm at rolling speed of 6.0 m/sec. The roll bonded AA6061/AA5052/AA6061 complex sheet is then hardened by natural aging(T4) and artificial aging(T6) treatments. The microstructures of the as-roll bonded and age-hardened Al complex sheets are revealed by optical microscopy; the mechanical properties are investigated by tensile testing and hardness testing. After rolling, the roll-bonded AA6061/AA5052/AA6061 sheets show a typical deformation structure in which grains are elongated in the rolling direction. However, after T4 and T6 aging treatment, there is a recrystallization structure consisting of coarse equiaxed grains in both AA5052 and AA6061 sheets. The as roll-bonded specimen shows a sandwich structure in which an AA5052 sheet is inserted into two AA6061 sheets with higher hardness. However, after T4 and T6 aging treatment, there is a different sandwich structure in which the hardness of the upper and lower layers of the AA6061 sheets is higher than that of the center of the AA5052 sheet. The strength values of the T4 and T6 age-treated specimens are found to increase by 1.3 and 1.4 times, respectively, compared to that value of the starting material.

Condition Monitoring Technique for Heating Cables by Detecting Discharge Signal (방전신호 검출에 의한 히팅 케이블의 상태감시기술)

  • Kim, Dong-Eon;Kim, Nam-Hoon;Lim, Seung-Hyun;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.2
    • /
    • pp.136-141
    • /
    • 2021
  • Heating cables, widely used in office buildings, factories, streets and railways, deteriorate in electrical insulation during operation. The insulation deterioration of heating cables leads to electric discharges that can cause electrical fires. With this background, this paper dealt with a condition monitoring technique for heating cables by the analysis of discharge signals to prevent electrical fires. Insulation deterioration was simulated using an arc generator specified in UL1699 under AC operation, and the characteristic and propagation of discharge signals were analyzed on a 100 meter-long heating cable. Discharge signals produced by insulation deterioration were detected as a voltage pulse because they are as small as a few mV and they are attenuated through propagation path. The frequency spectrum of discharge signals mainly existed in the range from 70 kHz to 110 kHz, and the maximum attenuation of the signal was 84.8% at 100 meters away from the discharge point. Based on the experimental results, a monitoring device, which is composed of a high pass filter with the cut-off frequency of 70 kHz, a comparator, a wave shaper and a microprocessor, was designed and fabricated. Also, an algorithm was designed to discriminate the discharge signal in the presence of noise, compared with the pulse repetition period and the number of pulse counts per 100ms. In the experiment, the result showed that the prototype monitoring device could detect and discriminate the discharge signals produced at every discharge point on a heating cable.

Effect of Rolling Conditions on Microstructure and Mechanical Properties of HCC AZ31 Alloy Plate (압연조건에 따른 AZ31 연주판재의 미세조직 및 기계적 특성 변화)

  • Kim, Young Min;Chun, Eun Young;Yim, Chang Dong;You, Bong Sun;Lee, Je-hyun
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.4
    • /
    • pp.189-198
    • /
    • 2008
  • The changes in microstructure and mechanical properties of AZ31 alloy subjected hot-rolling process were investigated. The AZ31 plates fabricated by horizontal continuous casting process were prepared and have hot-rolled from 30 mm to 1 mm in thickness under different processing conditions. At the rolling temperature of $400^{\circ}C$, little surface and side crack was observed up to 20% reduction rate. As total reduction and reduction rate increase to more than 75% and 20% pass, respectively, Grains were more uniformly refined through overall thickness, and particularly lots of shear bands were appeared to be inclined at less than $20^{\circ}C$ along the rolling direction. Average grain size of less than $5{\mu}m$ and tensile properties of YS ${\geq}$ 250 MPa, UTS ${\geq}$ 300 MPa and El. ${\geq}$ 13% were acquired for hot-rolled AZ31 sheets without post-heat treatment. Maximum intensity of (0002) pole figure was decreased with an increase in reduction rate, indicating the improvement of texture by means of high reduction rate.

Effects of Fully Filling Deep Electron/Hole Traps in Optically Stimulated Luminescence Dosimeters in the Kilovoltage Energy Range

  • Chun, Minsoo;Jin, Hyeongmin;Lee, Sung Young;Kwon, Ohyun;Choi, Chang Heon;Park, Jong Min;Kim, Jung-in
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.3
    • /
    • pp.134-142
    • /
    • 2022
  • Background: This study investigated the characteristics of optically stimulated luminescence dosimeters (OSLDs) with fully filled deep electron/hole traps in the kV energy ranges. Materials and Methods: The experimental group consisted of InLight nanoDots, whose deep electron/hole traps were fully filled with 5 kGy pre-irradiation (OSLDexp), whereas the non-pre-irradiated OSLDs were arranged as a control group (OSLDcont). Absorbed doses for 75, 80, 85, 90, 95, 100, and 105 kVp with 200 mA and 40 ms were measured and defined as the unit doses for each energy value. A bleaching device equipped with a 520-nm long-pass filter was used, and the strong beam mode was used to read out signal counts. The characteristics were investigated in terms of fading, dose sensitivities according to the accumulated doses, and dose linearity. Results and Discussion: In OSLDexp, the average normalized counts (sensitivities) were 12.7%, 14.0%, 15.0%, 10.2%, 18.0%, 17.9%, and 17.3% higher compared with those in OSLDcont for 75, 80, 90, 95, 100, and 105 kVp, respectively. The dose accumulation and bleaching time did not significantly alter the sensitivity, regardless of the filling of deep traps for all radiation qualities. Both OSLDexp and OSLDcont exhibited good linearity, by showing coefficients determination (R2) > 0.99. The OSL sensitivities can be increased by filling of deep electron/hole traps in the energy ranges between 75 and 105 kVp, and they exhibited no significant variations according to the bleaching time.

A comparison of ventilation effects using bag-valve-mask assist device (백-밸브-마스크 보조장치를 이용한 환기효과 비교)

  • EunYoung, Seo;ByoungGil, Yoon;GaEun, Kim;YougSeok, Kim
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.3
    • /
    • pp.37-46
    • /
    • 2022
  • Purpose: TThe experiment was designed to compare the efficiency of ventilation between conventional BVM ventilation and a newly devised A-BVM ventilation method with Tidal volume, total ventilation rate, average Ventilation speed, and average Ventilation volume. Methods: 40 Paramedical students who agreed to participate in the study were analyzed. Values were measured using IMB PASS after 2 minutes of Brayden Pro manikin with BVM and A-BVM ventilation. The difference in general characteristics was assessed by t-test and ANOVA and the difference in ventilation methods was analyzed by IBM SPSS. Results: A significant difference was found between the two ventilation methods in terms of tidal volume (t=-11.203, p<.001), ventilation time (t=-3.834, p<.001), and optimum ventilation probability (t=10.770, p<.001). A-BVM ventilation method, rather than BVM ventilation method, showed a value close to the appropriate amount recommended by Korean Advanced Life Support (500~600mL) in tidal volume, and higher in optimum ventilation probability. Conclusion: We could identify the a better mode of ventilation. Further studies on the efficacy of existing BVM ventilation methods as compared to device augmented BVM ventilation methods should be carried out to ensure that adequate ventilation is available to patients in clinical practice.