• Title/Summary/Keyword: M/N-Detector

Search Result 167, Processing Time 0.029 seconds

Design of The 10bit 80MHz CMOS D/A Converter with Switching Noise Reduction Method (스위칭 잡음 감소기법을 이용한 10비트 80MHz CMOS D/A 변환기 설계)

  • Hwang, Jung-Jin;Seon, Jong-Kug;Park, Li-Min;Yoon, Kwang-Sub
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.6
    • /
    • pp.35-42
    • /
    • 2010
  • This paper describes a 10 bit 80MHz CMOS D/A converter for wireless communication system. The proposed circuit in the paper is implemented with a $0.18{\mu}m$ CMOS n-well 1-poly 6-metal process. The architecture of the circuit consists of the 4bit LSB with binary decoder, and both the 3bit ULSB and the 3bit MSB with the thermometer decoder. The measurement results demonstrates SFDR of 60.42dBc at sampling frequency 80MHz, input frequency 1MHz and ENOB of 8.75bit. INL and DNL have been measured to be ${\pm}$0.38LSB and ${\pm}$0.32LSB and glitch energy is measured to be 4.6$pV{\cdot}s$. Total power dissipation is 48mW at 80MHz(maximum sampling frequency) with a single power supply of 1.8V.

Determination of Glutathione in Biological Samples by Ion-pairing HPLC/FLD (이온쌍 HPLC/FLD를 이용한 생체 시료중의 Glutathione 농도 분석)

  • Yoo, Jeong-Yeon;Lee, Kyoung-Ok;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.28-33
    • /
    • 1999
  • Glutathione(GSH) in biological samples was determined by high performance liquid chromatographic(HPLC) method with fluorescence detector(FLD) after monobromobimane(MBB) or 4-fluoro-7-sulfobenzofurazan(SBD-F) derivatization. The detection limit of $0.03{\mu}g/mL$ was obtained after MBB derivatization, derivative of MBB was about 200 times more sensitive than that of SBD-F. N-acetylcysteine was used as internal standard and tetrabutylammonium ion as counter ion for better separation. The determination by ion-pairing chromatography after MBB derivatization was characterized by linearity in the range between $0.08{\sim}8.33{\mu}g/mL$ with a good correlation coefficient of 0.998. By precision test appeared relative standard deviation at less than 5% at three different concentrations. This method can be used for the analysis of GSH in plasma and tissue.

  • PDF

Study for the Preparation of Deodorizing Fiber (Ⅰ) - Preparations of Deodorizing Fibers using Metalloporphyrines - (소취 섬유의 제조에 관한 연구 (Ⅰ) - 금속 포르피린을 이용한 소취 섬유의 제조 -)

  • O, Seon Hwa;Jeon, Suk Gyeong;Park, Su Min
    • Textile Coloration and Finishing
    • /
    • v.13 no.6
    • /
    • pp.9-9
    • /
    • 2001
  • The preparations of deodorizing fibers using metalloporphyrines have been investigated. The three metalloporphyrin derivatives(MTCPP, M=Mn, Zn, Sn) were prepared in modest to good yields. The metalloporphyrin derivative as a deodorant material was introduced to fibers by a dyeing method. The deodorant activity(D.A.) of these deodorizing fibers was measured by chromogenic gas detector tubes. In comparison with untreated fiber, these deodorizing fibers was remarkably effective against NH₃ and CH₃SH. More than 98% of ammonia can be removed within 20 min.. The D.A.(%) of fiber adsorbed MTCPP was more than 80% after 90min..

APPLICATION OF WHOLE BODY COUNTER TO NEUTRON DOSE ASSESSMENT IN CRITICALITY ACCIDENTS

  • Kurihara, O.;Tsujimura, N.;Takasaki, K.;Momose, T.;Maruo, Y.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.249-253
    • /
    • 2001
  • Neutron dose assessment in criticality accidents using Whole Body Counter (WBC) was proved to be an effective method as rapid neutron dose estimation at the JCO criticality accident in Tokai-mura. The 1.36MeV gamma-ray of $^{24}Na$ in a body can be detected easily by a germanium detector. The Minimum Detectable Activity (MDA) of $^{24}Na$ is approximately 50Bq for 10miniute measurement by the germanium-type whole body counter at JNC Tokai Works. Neutron energy spectra at the typical shielding conditions in criticality accidents were calculated and the conversion factor, whole body activity-to-organ mass weighted neutron absorbed dose, corresponding to each condition were determined. The conversion factor for uncollied fission spectrum is 7.7 $[(Bq^{24}Na/g^{23}Na)/mGy]$.

  • PDF

The development of scanning electron microscopy (전자현미경 개발)

  • Oh H. J.;Chang D. Y.;Yang H. N.;Kim D. H.;Park M, J.;Shim C. H.;Kim C. S.
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.15-18
    • /
    • 2005
  • We have designed and fabricated a thermal scanning electron microscopy. It includes an electron source, two condenser lenses, one objective lens, a scanning coil and a stigmator coil for focusing in column and also have a secondary electron detector for constructing the image in chamber with a high vacuum condition and control part for operating the SEM. Especially, in order for us to find out the optical characteristics, our attention and studies have been concentrated on the effects of two condenser lenses and one objective lens for high resolution with SEM. Finally, we developed a high resolution thermal scanning electron microscopy.

  • PDF

Superconducting Low-frequency Gravitational-wave Telescope (SLGT): pilot study status report

  • Kim, Chunglee;Ahn, Sang-Hyeon;Bae, Yeong-Bok;Kang, Gungwon;Kim, Whansun;Oh, John J.;Oh, Sang Hoon;Park, Chan;Son, Edwin J.;Lee, Yong Ho;Paik, Ho Jung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.2
    • /
    • pp.52.1-52.1
    • /
    • 2017
  • The discovery of GW150914, black hole - black hole merger via gravitational waves (GWs) opened a new window to observe the Universe. GW frequencies from heavenly bodies and early Universe are expected to span between sub-nHz up to kHz. At present, GW detectors on Earth (LIGO, Virgo, KAGRA, LIGO-India) aims frequency ranges between 10-2000 Hz. The space-borne GW detector and Pulsar Timing Array targets mHz and nHz sources. Starting in March 2017, the KKN (KASI-KISTI-NIMS) collaboration launched a pilot study of SLGT (Superconducting Low-frequency Gravitational-wave Telescope). This project is funded by NST (Korea Institute of Science and Technology). The main detection bands expected for SLGT ranges between 0.1-10Hz, which is complementary of LIGO-type detectors and LISA for multi-band GW observation. We will present an overview of the SLGT project and report the status of the NST pilot study. We will also present prospective of GW astronomy with SLGT.

  • PDF

Determination of some useful radiation interaction parameters for waste foods

  • Akman, F.;Gecibesler, I.H.;Sayyed, M.I.;Tijani, S.A.;Tufekci, A.R.;Demirtas, I.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.6
    • /
    • pp.944-949
    • /
    • 2018
  • The mass attenuation coefficients (${\mu}/{\rho}$) of food waste samples (pomegranate peel, acorn cap, lemon peel, mandarin peel, pumpkin peel, grape peel, orange peel, pineapple peel, acorn peel and grape stalk) have been measured employing a Si(Li) detector at 13.92, 17.75, 20.78, 26.34 and 59.54 keV. Also, the theoretical values of the mass attenuation coefficients have been evaluated utilizing mixture rule from WinXCOM program. The results showed that the lemon peel has the highest values of ${\mu}/{\rho}$ among the selected samples. From the obtained mass attenuation coefficients, we determined some absorption parameters such as effective atomic number ($Z_{eff}$), electron density ($N_E$) and molar extinction coefficient (${\varepsilon}$). It was found that the $Z_{eff}$ values of all food wastes lie within the range of 4.034-7.595, whereas the $N_E$ of the studied food wastes was found to be in the range of $0.301-1.720{\times}10^{25}$ (electrons/g) for present energy region.

Survey of nitroso-compounds level derived from additives in metal-working fluids (유통 수용성 금속가공유 중 니트로 화합물 함유 실태)

  • Yang, Jeong Sun;Choi, Jin Hee;Choi, Seong Bong;Lee, Jong Han
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.268-278
    • /
    • 2007
  • Nitrite which can be derived from water for dilution of metal working fluid can induce nitroso compounds which can be classified as carcinogen, if it co-exists with ethanolamines added for pH control in metal working fluid. The survey of nitrite, nitrate and nitroso-compounds level in 42 metal-working fluids collected from 17 factories was done by ion chromatography and gas chromatography with mass detector. Diluted metal working fluid showed higher level of nitrite and nitrate compared with raw fluid. Nitrite was detected in 11 (52%) samples among 21 diluted solution. Three (14%) samples showed over German recommendation level ($20{\mu}g/mL$).N-nitrosodiethanolamine(NDELA) was detected in 18 samples among 21 diluted solution. Seven (33%) samples showed over German recommendation level ($5{\mu}g/mL$). The concentration of NDELA was correlated with nitrite ion ($R^2=0.453$, n=19).

Design of a CMOS PLL with a Current Pumping Algorithm for Clock Syncronization (전류펌핑 알고리즘을 이용한 클락 동기용 CMOS PLL 설계)

  • 성혁준;윤광섭;강진구
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1B
    • /
    • pp.183-192
    • /
    • 2000
  • In this paper, the dual looped CMOS PLL with 3-250MHz input locking range at a single 13.3V is designed. This paper proposed a new PLL architecture with a current pumping algorithm to improve voltage-to-frequencylinearity of VCO(Voltage Controlled Oscillator). The designed VCO operates at a wide frequency range of75.8MHz-lGHz with a high linearity. Also, PFD(Phase frequency Detector) circuit preventing voltage fluctuation of the charge pump with loop filter circuit under the locked condition is designed. The simulation results of the PLL using 0.6 um N-well single poly triple metal CMOS technology illustrate a locking time of 3.5 us, a power dissipation of 92mW at 1GHz operating frequency with 125MHz of input frequency. Measured results show that the phase noise of VCO with V-I converter is -100.3dBc/Hz at a 100kHz offset frequency.

  • PDF

Analysis of caffeine in aqueous sample by hollow fiber-liquid microextraction (HF-LPME) (HF-LPME를 이용한 수용액 시료중의 카페인 분석)

  • In, Chi-Yeon;Kim, Taek-Jae;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.84-92
    • /
    • 2008
  • A method for the determination of trace amount of caffeine in urine and various drink samples using hollow fiber-liquid phase microextraction (HF-LPME) and capillary gas chromatograph/nitrogen phosphorus detector (GC/NPD) has been established. HF-LPME method has been optimized with respect to several experimental parameters including the effects of the hollow fiber length, extraction solvent, stirring mode, pH and salt concentration for the determination of caffeine from aqueous samples. The correlation coefficient of calibration curve for caffeine was 0.9994. The average recovery was 102%(n=3). The established method is feasible for the determination of trace amounts of caffeine in several aqueous sample. The limit of detection (LOD) and the limit of quantitation (LOQ) have been found to be 2.5 and 10 ng/mL, respectively. The established HF-LPME method for the analysis of caffeine from aqueous sample can be used for the determination of biological, food and environmental samples.