• Title/Summary/Keyword: Luminance performance test

Search Result 41, Processing Time 0.026 seconds

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Determination of Optimal Mixing Ratio of Phosphorescent Pigment to Develop Phosphorescent Paint for Road Line Marking (도로의 축광차선 도료 개발을 위한 축광안료 최적 배합비 산정에 관한 연구)

  • Lee, Yong Mun;Kim, Sang Tae;Kim, Heung Rae
    • International Journal of Highway Engineering
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2015
  • PURPOSES : This study was conducted to derive the optimum mixing ratio of phosphorescent pigment for the development of phosphorescent line marking. METHODS: In this study, we utilized a literature review and case study methodology, to describe the domestic and foreign state of practice for the production and mixing of phosphorescent pigment for use in line marking. The optimal mixing ratio was derived by comparing the reduction in luminance over time for the various phosphorescent pigment mixing ratios identified in the literature. In addition, performance and construction characteristics were analyzed using field testing techniques. RESULTS : The results were as follows: 1) the results of the luminance performance standards tests showed that all of the phosphorescence test specimens satisfied the phosphorescent fire protection standard. As the phosphorescent pigment mixing ratio increased, the luminance value increased, 2) the luminance reduction rate was minimum at the mixing ratio of 50%. However, when compared to a mixing ratio 40%, a small difference was recorded, the luminance reduction rate from the mixing ratio of 40% is judged as being converged. Therefore, in view of the economic efficiency, it was determined that the optimal mixing ratio was 40%, 3) as a result of construction on the field, a mixing ratio of 40% was found to have a higher luminance value than the general line marking for up to three hours after sunset, 4) it was found that the phosphorescent line markings without glass beads spraying had a higher luminance value than the phosphorescent line markings with glass beads spraying. CONCLUSIONS : Through the results of the basic experiments of the line markings obtained by blending a phosphorescent pigment, the results could be applied to play an important role in the development of phosphorescent line marking paint technology and in establishing application planning for on-site construction characteristics.

Comparison of Safety Level between Driver's Ages by Threshold Zone Luminance Level of Vehicular Traffic Tunnel (터널 경계부 휘도수준에 따른 운전자 연령대별 안전수준 비교)

  • Cho, Won Bum;Jeong, Jun Hwa;Kim, Do Gyeong;Park, Won Il
    • International Journal of Highway Engineering
    • /
    • v.17 no.1
    • /
    • pp.129-142
    • /
    • 2015
  • PURPOSES : The purpose of this study is to suggest a basis for setting appropriate safety goals specifically related to the threshold zone luminance in a vehicular traffic tunnel. METHODS : In the test, drivers were divided into two groups. One group consisted of all drivers (average drivers) group with an age ratio of drivers holding domestic driver's license and driver group by age to produce threshold zone luminance in the tunnel. The threshold zone luminance produced as a result was used to analyze how it affects the safety level of each driver group and provide a basis for setting an appropriate safety criterion that can be used to determine threshold zone luminance. We used test equipment, test conditions, and ananalysis of threshold zone luminance identical to that reported by ChoandJung(2014) but the values of adaptation luminance in our analys is were expanded to range from100 to $10,000cd/m^2$. RESULTS : Adaptation luminance and threshold zone luminance are found to be related by a quadratic function. The threshold zone luminance needed by older drivers to ensure a certain safety level is significantly higher than that for drivers of other age brackets when adaptation luminance increases. 56% of older drivers are at an increased risk of an accident at the same luminance for which the safety level of average drivers is 75%. The safety level that can be achieved for older drivers increases to above 60% when threshold zone luminance level is set with the goal of attaining a safety level of more than 85% for average drivers. The safety level that can be attained for average drivers is above 90% when the threshold zone luminance is high enough to ensure over 75% in the safety level of older drivers. Results of this study are applicable to highways and others whose designed speed is 100 km/h. CONCLUSIONS : Threshold zone luminance determined on the basis of drivers having average visual ability is of limited value as a performance standard for ensuring the safety of older drivers. Hence, safety level for older drivers should be considered separately from safety levels for drivers with an average ability to avoid risk. Upward adjustment of older drivers' safety level in the process of determining appropriate threshold zone luminance in a vehicular traffic tunnel may bring both tangible and intangible benefit as a result of reducing accidents. However, there is an associated dollar cost arising from installing and operating lights. As a result, the economic impact of these trade-offs should also be considered.

Comparative Luminance and Correlated Color Temperature of Work-place by a Fluorescent and LED Light Sources (LED광원과 형광광원에 의한 작업면의 휘도 및 색온도 비교)

  • Baik, Seung heon;Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.21-26
    • /
    • 2008
  • According to the tendency of energy efficiency and environment-friendly chracteristics, demend of High-efficiency lighting using LED(Light Emitting Diode)are being increased actively and applied in various fields. However, In order to adequate application of LED light sources, it is necessary to lighting environment and luminous characteristics of LED light sources. This Study aims to characterize the work-plane lighting environment by LED light sources comparing with fluorescent light sources which are widely used. For the sake of this study, a fluorescent light source and 5 LED light sources were introduced and luminance and correlated color temperature were measured to evaluate luminance contrast. The experimental model is Mock-up which is $4.9m{\times}7.2m$ with a height of 2.9m. The test room was set up partition and desks. Luminance and correlated color temperature were measured work-plane on the desk which was set up local lighting by the Radiant Imaging ProMetric 1400. The optical characteristics data of LED can give a lot of advantages to design LED lighting appliances. Hereafter, the object of research will be conducted to evaluate effects of LED light sources on working performance, survey of visual performance, preference and physiology of subjects.

Comparative Daylighting Performance Analysis of Offices in 1/10, 1/5 Scale Models and Mock-up Model (실물대모형 및 1/5, 1/10축소모형의 자연채광 성능평가에 관한 비교분석)

  • Baik, Seung Heon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.25-32
    • /
    • 2006
  • Mock-up model can be applied to measure accurate performance data but difficult to apply the variables in experiment. There can be a slight experiment errors in Scale model, but various parameters can be applied for a objective experiment. This paper aims to compare the daylighting performance in 1, 1/5, 1/10 scale model of offices and analyze the experiment errors to certificate the influence of model experiment. To analyse daylighting performance, a comparison of a Mock-up model, sized $12.0m(w){\times}7.2m(l){\times}3.7m(h)$, designed for experimentation of daylighting systems and its 1:5, 1:10 scale model. It has an identical configuration of reference room and the test room. For the test room, the lightshelf system was designed as Micro-4 reflective material. To assess work plane illuminance and light factor, photometric sensors of each room were installed at work-plane(6 points) and exterior horizontal illuminance (1 point). And luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio and luminance are discussed.

Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment (Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험)

  • Kim, Jeong Tai;Shin, Hwa Young
    • KIEAE Journal
    • /
    • v.6 no.2
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System (수직형 라이트파이프의 채광성능에 관한 예비평가)

  • Shin, Hae Mi;Park, Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

Parameter Estimations of ML Test Based Decoders for Perceptually Watermarked Images

  • Lee, Jin-Geol
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.12
    • /
    • pp.1631-1637
    • /
    • 2005
  • Based on the generalized Gaussian pdf of DCT coefficients of images, Hernandez et al. propose the ML test applied watermark decoder. For images with watermarks shaped by the visibility thresholds of DCT coefficients and the luminance masking of human visual system, they conclude that the ML test with an appropriately chosen parameter associated with the pdf of DCT coefficients outperforms the correlation based decoder. In this paper, the parameter is estimated using various methods including a novel one for watermarks shaped by the visibility thresholds of DCT coefficients and the luminance masking as Hernandez et al. did and with the contrast masking added, and its effect on performance is compared.

  • PDF

Evaluation of luminance performance of scintillating film for monitoring the position of a radioactive source in an NDT apparatus (비파괴검사 장치 내 방사선원 위치감시용 섬광필름의 발광성능 평가)

  • Lee, Kyung-Jin;Yun, Jeong-Ick;Park, Byung-Gi;Kim, Sin;Lee, Bong-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • In domestic nondestructive testing(NDT) field, there have recently been radiation exposure accidents due to a disregard for confirmation of the position of radioisotope during the test. In order to prevent these kinds of accidents, a scintillating film has been developed. The scintillating film that can convert gamma-ray to visible light has a function of the position detection of radioisotope in a opaque guide tube of an NDT apparatus. The aim of this study is to enhance the visibility performance of the scintillating film and find out the best configuration of the scintillating film. In order to find appropriate materials for the scintillating film, various inorganic scintillating materials were evaluated in this work. An absolute luminance of the scintillating films was measured by luminance meter for evaluation of visibility performance. Ir-192 gamma projector was used for NDT apparatus. The experiment shows that the scintillating film with reflective layer was the more effective performance for visibility. The higher mixing ratio of scintillating material to binding material, the higher luminance was measured. $Gd_2O_2S(Tb)$ inorganic powder as the scintillating materials had the best performance for visibility of the scintillating film. The developed scintillating film helps to ensure safer environment to the operators.

  • PDF

Assessment of LCD Color Display Performance Based on AAPM TG 18 Protocol : Decision of Quality Control and Calibration Period (판독용 LCD 컬러 모니터 장치의 성능 평가 - 성능 평가 및 Calibration 주기 결정을 중심으로 -)

  • Lee, Won-Hong;Son, Soon-Yong;Noh, Sung-Soon;Lee, In-Hwa;Kang, Sung-Ho;Lee, Yong-Moon;Park, Jae-Soo;Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.55-60
    • /
    • 2008
  • Purpose: This study is to decide a quality control and calibration period of LCD display devices used for reading diagnostic images. Materias and Methods: The assessment test of 20 flat panel LCD color display devices used for reading diagnostic images were performed based on AAPM TG 18 protocol over the total six sessions at one month intervals from three months after primary calibration, in terms of geometric distortion, reflection test, luminance response evaluation, luminance uniformity, resolution, noise, veiling glare and chromaticity test. Results: The results of geometric distortion, reflection test, luminance uniformity, resolution, noise, veiling glare and chromaticity test were within the criteria recommended by AAPM TG 18, except for luminance response evaluation. In the measured luminance deviation of luminance response evaluation, 4(25%) of 20 display devices were passed a criterion from four months after calibration, and 11 (55%) were passed from eight months. Also in the contrast response of the luminance response evaluation, 1(5%) display device was passed a criterion from four months after calibration, and 3(15%) were passed from eight months. Conclusion: Considering the passing deviation after calibration, the time required and a manpower, the quality control and calibration period of LCD display devices used for reading diagnostic images should be a three months and six months after calibration.

  • PDF