• 제목/요약/키워드: Low voltage cable

검색결과 124건 처리시간 0.023초

온도특성을 고려한 저압간선의 경제적인 설계기법에 관한 연구 (A Study on the Economical Design of Low-Voltae feeder Considering the temperature character)

  • 최홍규;조계술
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.349-354
    • /
    • 2002
  • A size of low-voltage conductor cables is determined by the voltage drop of a system, the cable impedance and the cable ampacity based on temperature correction factor in accordance with the condition of cable installation. Therefore, the proper temperature correction factor according to the condition of cable installation should be applied to determining the cable ampacity and also the skin effect and proximity effect, along with the kind and size of conductor and the condition of cable installation, should be properly considered to analyze the proper value of resistance and the reactance of the conductors. This paper addresses the systematic design flow for determining the size of low voltage level conductor cables in calculating the temperature character where error should be minimized in comparison with the general formula and which can be applied in design work for determining the size of conductor cables.

  • PDF

전압강하를 고려한 저압간선의 설계 알고리즘 (Algorithm for the Low-Voltage Feeder Design in Consideration of Voltage Drop)

  • 고영곤;최홍규;조계술
    • 조명전기설비학회논문지
    • /
    • 제16권3호
    • /
    • pp.84-92
    • /
    • 2002
  • 저압간선의 굵기는 계통의 전압강하, 간선의 포설조건별 온도 보정계수를 적용한 허용 전류 및 간션의 임피 던스 값에 따라 결정된다. 따라서, 간선의 허용전류 값올 결정하기 위하여 간선의 포셜조건에 따른 적정 보정계 수가 적용되어야 하며, 저압간선의 정확한 임피던스 값을 분석하기 위하여 간선의 종류, 간선의 규격, 포셜조건 에 따른 온도, 표피효과 및 근접 효과 둥이 고려되어야 한다. 본 연구는 저압계통의 전압강하를 고려한 간선의 굵기 산정에 대한 체계적인 설계 흐름도를 제시 하였으며, 일반적인 계산 방식에 비하여 오차가 적은 계수로서 저압간선 굵기 선정 설계 실무에 적용할 수 있는 계산 방식을 연구하였다.

저압다심케이블에서 충진물(개재물)이 절연저항에 미치는 영향 분석 (The Analysis of change of insulation resistance by filler on low voltage multi core cables)

  • 고영훈;박의석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.71-72
    • /
    • 2007
  • The insulation is a important part of cable. In thisb paper, measured the insulation resistance for analysing of change of insulation resistance by filler on low voltage multicore cables. The insulation resistance is not effected by only insulation material, but also filler material. The insulation resistance is different with measuring before filling and after filling by filler. When develope the new filler or cable, the volume resistance of filler must be considered.

  • PDF

지중송전선 고장점 탐색 장치 설계 (Design of Fault Location System for High Voltage Underground Power Cable)

  • 이재덕;류희석;최상봉;남기영;정성환;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.603-605
    • /
    • 2006
  • To reduce inference of any power delivery failures in underground power cable, power system operators are trying to find effective way of finding fault location as soon as possible. But it is very difficult to find fault location exactly for underground power cable. We are developing fault location system for underground power cable which can detect its fault location exactly. This new system monitors current and voltage of underground power cable by using low voltage and current sensors and if there are any accidents, it records its transient signal. Fault location is calculated by analyzing recorded signal. To develop fault location system for power cable, we needed fault simulation system and we installed it physically and tested. In this rapers, we describe on describe of fault location system for underground power cable.

  • PDF

고압전력케이블 현장진단시험용 종합 직류시험설비의 검토 (Design of a composite diagnostic DC test apparatus for high voltage power cable)

  • 류희석;강동식;심종태;이호진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2326-2328
    • /
    • 1999
  • Developments of effective and economic diagnostic apparatus for industrial plastic insulated high voltage power cables are in discontented condition still. Some report told that DC high voltage was damaged plastic insulation of a partially aged power cable to lead breakdown easily. But now, we have no alternative tools of DC diagnostic apparatus, and we try to reduce a possibility of hazard DC diagnosis. DC diagnostic apparatus still have many advantages to field cable engineer like low price, portability easy applications and sufficient data. Main hazard of DC diagnosis is excessive hight of applied voltage Recent developments for DC diagnosis use considerably low voltage. But new test methods need special measuring device and manipulator, like high input impedance voltmeter, low leakage current high voltage switches, etc. So that reason, new DC diagnostic devices are normally very expensive and have low efficiency, economically. We try to design a composite test device for 3$\sim$4 newly developed method, have economical benefit th industrial engineer.

  • PDF

Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable

  • Ebinuma, Yasumitsu;Masui, Noriaki
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.224-229
    • /
    • 2006
  • Many studies have been done on the application of residual charge measurement in cable degradation diagnosis. In this paper, the behavior of residual charges measured with water-tree degraded XLPE sheets and cable are discussed. At charge injection process, the charge is injected by applying dc voltage as a conventional method, suddenly cut-off ac voltage or impulse voltage. Therefore the residual charge is influenced by the applying process. At charge release process, transient dc current flows when applying ac high voltage and also ac high voltage superimposed to dc low voltage. From the results, new diagnosis method is suggested.

맨홀용 및 핸드홀용 지중 저압케이블 접속장치 개발 (Development of connection device for underground low voltage cable of manhole and handhole)

  • 이강중;이은정;주종민;유근양
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1056-1058
    • /
    • 2005
  • It shows a tendency to increase rapidly underground of the city due to the build up of the large residential districts with industrial development, so there is required the development of the connection device for underground low voltage cable with high quality & convenient for use with consideration for installation condition of the underground. Hence, We will have the development of the connection device for underground low voltage cable, which is made waterproof perfectly under the flood of the underground for the long time, is convenient for use in spite of narrow area such as manhole or handhole, and can be able to prevent the release by the vibration.

  • PDF

초고압 XLPE 케이블 금속 차폐층 고찰 (A study or Metallic sheath for Extra-high voltage XLPE cable)

  • 최창수;이갑중;정무영;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1652-1654
    • /
    • 1994
  • The Extra-high voltage XLPE cable is characterized by low transmission loss, large capacity, and high reliability. Conventionally, for XLPE cables of l54kV and above, aluminium sheath was used to be moisture barrier (thus preventing water tree deterioration of the insulation) and to protect cable core from physical stresses. However, as transmission capacity of the cable increases, so does the cable diameter and the corresponding aluminium sheath outer diameter and thickness. As a result, eddy-current loss in the sheath is increased, limiting the maximum current capacity of the cable itself. As an alternative to aluminium sheath, we have adopted stainless steel sheath with non-magnetic properties and a large resistivity, The new XLPE cable with stainless-steel sheath (CSZV cable) has drastically reduced eddy-current loss in the sheath.

  • PDF

저압용 서지 보호 장치(SPD)의 보호 거리 해석 (Analysis of the Protective Distance of Low-Voltage Surge Protective Device(SPD) to Equipment)

  • 이정우;오용택
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.28-34
    • /
    • 2012
  • Installing surge protection devices for a low-voltage system is important to ensure the survival of electric or electronic devices and systems. If surge protection devices (SPD) are installed without consideration of the concept of lightning protection zones, the equipment to be protected might be damaged despite the correct energy coordination of SPDs. This damage is induced by the reflection phenomena on the cable connecting an external SPD and the load protected. These reflection phenomena depend on the characteristics of the output of the external SPD, the input of the loads, and the cables between the load and the external SPD. Therefore, the SPD has an effective protection distance under the condition of the specific load and the specific voltage protection level of SPD. In this paper, PSCAD/EMTDC software is used to simulate the residual voltage characteristics of SPD Entering the low-voltage device. And by applying a certain voltage level, the effective protection distances of SPD were analyzed according to the each load and length of connecting cable, and the effectiveness of SPD were verified.

SSTDR에서 시간-주파수 상관을 활용한 저압 케이블의 고장 검출 (Fault Detection of Low Voltage Cable using Time-Frequency Correlation in SSTDR)

  • 전정채;김택희;유재근
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.498-504
    • /
    • 2015
  • This paper proposed an Spread Spectrum Time Domain Reflectometry (SSTDR) using time-frequency correlation analysis in order to have more accurate fault determination and location detection than classical SSTDR despite increased signal attenuation due to the long distance to cable fault location. The proposed method was validated through comparison with classical SSTDR methods in open- and short-circuit fault detection experiments of low-voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.