• Title/Summary/Keyword: Low power systems

Search Result 2,394, Processing Time 0.031 seconds

Design and Implementation of a Chaotic Oscillator for UWB (UWB용 카오스 오실레이터의 설계 및 구현)

  • Kang, Sang-Gee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2136-2139
    • /
    • 2008
  • Chaotic oscillators can generate wide-band signals and the spectrum characteristics of the wide-band signals are not changed by switching on and off the output power of the oscillators. When communication systems use a chaotic oscillator, the communication system need not a local oscillator and a mixer used in conventional transceivers. Therefore the configuration of a communication system using a chaotic oscillator is simple and have the characteristics of low-power consumption. In this paper we design and implement a chaotic oscillator. And the test results of the implemented chaotic oscillator for UWB systems are presented. The implemented chaotic oscillator has -8.11dBm of the output power with 500MHz channel bandwidth at 3.4GHz of the center frequency and has about 410MHz of -10dB bandwidth.

Application of BIPV System Functioned as Solar Collector (태양열 집열기 기능을 갖는 BIPV 시스템의 응용)

  • Min, Sung-Hye;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.953-958
    • /
    • 2006
  • Perimeter zone has been reinforced by active systems, such as fan-coil units, because it causes an increase in heating and cooling loads, dew condensation in winter, or discomfort with cold-draft to residents in buildings, through poor insulation by light-weighed skin due to progressing multi-storied buildings and skyscrapers. However, because these active systems raise Its capacity so that fossil fuel is used as much as they are added, and ultimately, greenhouse effect is urged, we proposed BIPV system functioned as solar collector which can substitute active system. As an early stage, heat balance equation in steady-state by Fortran was used not only for pre-heating effect and electric power capacity during the day in winter, but also for electric power capacity during day in slimmer and sky radiation effect during night in summer. Especially, we should have considered shading on PV, since even a little bit of it makes the efficiency too low for the PV to work. Still, when the flux of pre-heated air was increased to make air-barrier, its temperature was not enough to make it because the speed of heat exchange was too fast to warm up the air, thus the capacity to meet the condition was evaluated, and electric power from PV was made used for it.

  • PDF

Design and Implementation of Location and Activity Monitoring System Based on LoRa

  • Lin, Shengwei;Ying, Ziqiang;Zheng, Kan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.4
    • /
    • pp.1812-1824
    • /
    • 2019
  • The location and human activity are usually used as one of the important parameters to monitor the health status in healthcare devices. However, nearly all existing location and monitoring systems have the limitation of short-range communication and high power consumption. In this paper, we propose a new mechanism to collect and transmit monitoring information based on LoRa technology. The monitoring device with sensors can collect the real-time activity and location information and transmit them to the cloud server through LoRa gateway. The user can check all his history and current information through the specific designed mobile applications. Experiment was carried out to verify the communication, power consumption and monitoring performance of the entire system. Experimental results demonstrate that this system can collect monitoring and activity information accurately and provide the long rang coverage with low power consumption.

A Modified Capacitor Current Feedback Active Damping Approach for Grid Connected Converters with an LCL Filter

  • Wan, Zhiqiang;Xiong, Jian;Lei, Ji;Chen, Chen;Zhang, Kai
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1286-1294
    • /
    • 2015
  • Capacitor current feedback active damping is extensively used in grid-connected converters with an LCL filter. However, systems tends to become unstable when the digital control delay is taken into account, especially in low switching frequencies. This paper discusses this issue by deriving a discrete model with a digital control delay and by presenting the stable region of an active damping loop from high to low switching frequencies. In order to overcome the disadvantage of capacitor current feedback active damping, this paper proposes a modified approach using grid current and converter current for feedback. This can expand the stable region and provide sufficient active damping whether in high or low switching frequencies. By applying the modified approach, the active damping loop can be simplified from fourth-order into second-order, and the design of the grid current loop can be simplified. The modified approach can work well when the grid impedance varies. Both the active damping performance and the dynamic performance of the current loop are verified by simulations and experimental results.

Development of Converter for High Frequency Welding Machines using Active Snubber (액티브 스너버를 이용한 고주파 용접기 컨버터 개발)

  • Shin, Jun-Young;Lee, Jae-Min;Choi, Seung-Won;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.351-355
    • /
    • 2016
  • Welding machines are high-capacity systems used in a low-frequency range using IGBT. As their system is similar to a large transformer, most welding machines suffer a great loss because of hard switching and vast leakage inductance. A voltage-balancing circuit is designed to overcome these shortcomings. This circuit can reduce the transformer size by making it into a high frequency and reducing the input voltage by half and by adopting a serial structure that connects two full-bridges in a series to use a MOSFET with a good property at high frequency. In addition, a Schottky diode is used in the primary rectifier to overcome the low efficiency of most welding machines. To use the Schottky diode with a reliably relatively low withstanding voltage, an active snubber is adopted to effectively limit the ringing voltage of the diode cut-off voltage.

Deep compression of convolutional neural networks with low-rank approximation

  • Astrid, Marcella;Lee, Seung-Ik
    • ETRI Journal
    • /
    • v.40 no.4
    • /
    • pp.421-434
    • /
    • 2018
  • The application of deep neural networks (DNNs) to connect the world with cyber physical systems (CPSs) has attracted much attention. However, DNNs require a large amount of memory and computational cost, which hinders their use in the relatively low-end smart devices that are widely used in CPSs. In this paper, we aim to determine whether DNNs can be efficiently deployed and operated in low-end smart devices. To do this, we develop a method to reduce the memory requirement of DNNs and increase the inference speed, while maintaining the performance (for example, accuracy) close to the original level. The parameters of DNNs are decomposed using a hybrid of canonical polyadic-singular value decomposition, approximated using a tensor power method, and fine-tuned by performing iterative one-shot hybrid fine-tuning to recover from a decreased accuracy. In this study, we evaluate our method on frequently used networks. We also present results from extensive experiments on the effects of several fine-tuning methods, the importance of iterative fine-tuning, and decomposition techniques. We demonstrate the effectiveness of the proposed method by deploying compressed networks in smartphones.

Self-Adaptive Termination Check of Min-Sum Algorithm for LDPC Decoders Using the First Two Minima

  • Cho, Keol;Chung, Ki-Seok
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.1987-2001
    • /
    • 2017
  • Low-density parity-check (LDPC) codes have attracted a great attention because of their excellent error correction capability with reasonably low decoding complexity. Among decoding algorithms for LDPC codes, the min-sum (MS) algorithm and its modified versions have been widely adopted due to their high efficiency in hardware implementation. In this paper, a self-adaptive MS algorithm using the difference of the first two minima is proposed for faster decoding speed and lower power consumption. Finding the first two minima is an important operation when MS-based LDPC decoders are implemented in hardware, and the found minima are often compressed using the difference of the two values to reduce interconnection complexity and memory usage. It is found that, when these difference values are bounded, decoding is not successfully terminated. Thus, the proposed method dynamically decides whether the termination-checking step will be carried out based on the difference in the two found minima. The simulation results show that the decoding speed is improved by 7%, and the power consumption is reduced by 16.34% by skipping unnecessary steps in the unsuccessful iteration without any loss in error correction performance. In addition, the synthesis results show that the hardware overhead for the proposed method is negligible.

An Experimental Investigation on Low Cycle Fatigue Behavior of Alloy 617 Base Metal and Alloy 617/Alloy 617 Weld Joints (Alloy 617 모재와 용접부재의 저사이클피로 거동에 관한 실험적 고찰)

  • Choi, Pil-Ho;Kim, Seon-Jin;Kim, Woo-Gon;Kim, Min-Hwan
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.115-121
    • /
    • 2014
  • Alloy 617 is the one of the leading candidate materials for intermediate heat exchangers(IHX) of a very high temperature reactor(VHTR) system. Some of the components are joined by many welding techniques and therefore the welded joints are inevitable in the construction of systems. In the present paper, the low cycle fatigue(LCF) behaviors of Alloy 617 base metal(BM) and the gas tungsten arc welded (GTAWed) weld joints(WJ) are investigated experimentally under strain controlled LCF tests. Fully axial total-strain controlled tests have been conducted at room temperature with total strain ranges of 0.6, 0.9, 1.2 and 1.5%. The weld joints have shown a lower fatigue lives compared with base metals at all the testing conditions. The weld joints have shown a higher cyclic stress response behavior than base metal. Both BM and WJ exhibited cyclic strain hardening behavior, depending on the total strain range. In addition, the strain-life parameters for BM and WJ were determined, based on Coffin-Manson equations.

A Dynamic Voltage Scaling Algorithm for Low-Energy Hard Real-Time Applications using Execution Time Profile (실행 시간 프로파일을 이용한 저전력 경성 실시간 프로그램용 동적 전압 조절 알고리즘)

  • 신동군;김지홍
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.29 no.11
    • /
    • pp.601-610
    • /
    • 2002
  • Intra-task voltage scheduling (IntraVS), which adjusts the supply voltage within an individual task boundary, is an effective technique for developing low-power applications. In this paper, we propose a novel intra-task voltage scheduling algorithm for hard real-time applications based on average-case execution time. Unlike the conventional IntraVS algorithm where voltage scaling decisions are based on the worst-case execution cycles, tile proposed algorithm improves the energy efficiency by controlling the execution speed based on average-case execution cycles while meeting the real-time constraints. The experimental results using an MPEG-4 decoder program show that the proposed algorithm reduces the energy consumption by up to 34% over conventional IntraVS algorithm.

Effects of alloys and flow velocity on welded pipeline wall thinning in simulated secondary environment for nuclear power plants (원전 2차계통수 모사 환경에서 용접배관 감육 특성에 미치는 재료 및 유속의 영향)

  • Kim, Kyung Mo;Choeng, Yong-Moo;Lee, Eun Hee;Lee, Jong Yeon;Oh, Se-Beom;Kim, Dong-Jin
    • Corrosion Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.245-252
    • /
    • 2016
  • The pipelines and equipments are degraded by flow-accelerated corrosion (FAC), and a large-scale test facility was constructed for simulate the FAC phenomena in secondary coolant environment of PWR type nuclear power plants. Using this facility, FAC test was performed on weld pipe (carbon steel and low alloy steel) at the conditions of high velocity flow (> 10 m/s). Wall thickness was measured by high temperature ultrasonic monitoring systems (four-channel buffer rod type and waveguide type) during test period and room temperature manual ultrasonic method before and after test period. This work deals with the complex effects of flow velocity on the wall thinning in weld pipe and the test results showed that the higher flow velocity induced different increasement of wall thinning rate for the carbon steel and low alloy steel pipe.