Application of BIPV System Functioned as Solar Collector

태양열 집열기 기능을 갖는 BIPV 시스템의 응용

  • Min, Sung-Hye (Department of Architectural Engineering, Inha University) ;
  • Suh, Seung-Jik (Department of Architectural Engineering, Inha University)
  • 민성혜 (인하대학교 대학원 건축공학과) ;
  • 서승직 (인하대학교 건축학부)
  • Published : 2006.06.21

Abstract

Perimeter zone has been reinforced by active systems, such as fan-coil units, because it causes an increase in heating and cooling loads, dew condensation in winter, or discomfort with cold-draft to residents in buildings, through poor insulation by light-weighed skin due to progressing multi-storied buildings and skyscrapers. However, because these active systems raise Its capacity so that fossil fuel is used as much as they are added, and ultimately, greenhouse effect is urged, we proposed BIPV system functioned as solar collector which can substitute active system. As an early stage, heat balance equation in steady-state by Fortran was used not only for pre-heating effect and electric power capacity during the day in winter, but also for electric power capacity during day in slimmer and sky radiation effect during night in summer. Especially, we should have considered shading on PV, since even a little bit of it makes the efficiency too low for the PV to work. Still, when the flux of pre-heated air was increased to make air-barrier, its temperature was not enough to make it because the speed of heat exchange was too fast to warm up the air, thus the capacity to meet the condition was evaluated, and electric power from PV was made used for it.

Keywords