• Title/Summary/Keyword: Low order controller

Search Result 298, Processing Time 0.026 seconds

Advanced Synchronous Reference Frame Controller for three-Phase UPS Powering Unbalanced and Nonlinear Loads (3상 무정전 전원장치에 적합한 새로운 구조의 동기좌표계 전압제어기)

  • Hyun Dong-Seok;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.508-517
    • /
    • 2005
  • This paper describes a high performance voltage controller for 3-phase 4-wire UPS (Uninterruptible Power Supply) system, and proposes a new scheme of synchronous reference frame controller in order to compensate for the voltage distortions due to unbalanced and nonlinear loads. Proposed scheme can eliminate the negative sequence voltage component due to unbalanced loads and also reduce the harmonic voltage component due to non-linear loads, even when the bandwidth of voltage control loop is a very low. In order to compensate for the effects of unbalanced loads, the synchronous reference frame controller with the positive and negative sequence computation block is proposed, and the synchronous frame controller with a bandpass filter is proposed to compensate for the selected harmonic frequency of output voltage. The effectiveness of the proposed scheme has been investigated and verified through computer simulations and experiments by a 30kVA UPS.

Improvement of Steady State Response Using PI+Double Integral Controller (비례적분+이중적분 제어기를 이용한 정상상태 응답 개선)

  • Jung, Gyu Hong
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.24-31
    • /
    • 2016
  • The performance characteristics of a dynamic control system are evaluated according to the transient and steady-state responses. The transient performance is the controllability of the output for the tracking of the reference or the ability to reduce or reject the effects of unwanted disturbances; alternatively, the steady-state performance is represented by the magnitude of the control error at the steady state. As the effects of the two performances on each other are reciprocal, a controller design that shows a zero steady-state error for the ramp input is uncommon because of the challenge regarding the achievement of an acceptable transient response. This paper proposes a PI+double-integral controller for the elimination of the steady-state error for the ramp input while a sound transient performance is maintained. The control-gain design procedure is described by the second-order response for the step input and the response of the error dynamics for the ramp input. The PI+double-integral controller is designed for the first-order transfer function that is derived from a system identification with the open-loop experiment data of the dc-motor. The simple structure of the proposed controller enables the adoption of a low-end microcontroller for the implementation of a real-time control. The experiment results show that the control performance is as effective as that of the simulation analysis for the operating point of linear system; furthermore, the PI+double-integral controller can be conveniently applied to the control system, which is desirable for the improvement of the steady-state error.

Internet Based Tele-operation of the Autonomous Mobile Robot (인터넷을 통한 자율이동로봇 원격 제어)

  • Sim, Kwee-Bo;Byun, Kwang-Sub
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.6
    • /
    • pp.692-697
    • /
    • 2003
  • The researches on the Internet based tole-operation have received increased attention for the past few years. In this paper, we implement the Internet based tele-operating system. In order to transmit robustly the surroundings and control information of the robot, we make a data as a packet type. Also in order to transmit a very large image data, we use PEG compressive algorithm. The central problem in the Internet based tele-operation is the data transmission latency or data-loss. For this specific problem, we introduce an autonomous mobile robot with a 2-layer fuzzy controller. Also, we implement the color detection system and the robot can perceive the object. We verify the efficacy of the 2-layer fuzzy controller by applying it to a robot that is equipped with various input sensors. Because the 2-layer fuzzy controller can control robustly the robot with various inputs and outputs and the cost of control is low, we hope it will be applied to various sectors.

A Control Strategy for Switched Reluctance Motor with High Sspeed Operation (고속에서의 스위치드 리럭턴스 모터의 제어 기법)

  • 유준석;이태규;허욱열
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.370-376
    • /
    • 1993
  • In this paper, we present the voltage source algorithm for high speed and low torque ripple operation of a switched reluctance motor (SRM). The SRM has simpler structure than the traditional dc or ac motor. It has a high starting torque and can be operated in the wide range of speed. So it can be applied to various areas. But the SRM has some difficulties in driving circuit and controller due to the large inductance variations. In this study, in order to produce the low torque ripple and the high speed operation, a voltage source algorithm is proposed. We showed the good performance of the proposed controller through simulation and experiment.

  • PDF

Development of 3 Phase PWM Converter using Analog Hysteresis Current Controller (아날로그 히스테리시스 전류 제어기를 적용한 3상 PWM 컨버터 개발)

  • Lee Young-kook;Noh Chul-won
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.372-376
    • /
    • 2001
  • Due to several advantages of Pulse Width Modulation(PWM) Converter, such as unity power factor operation, elimination of low-order harmonics and regeneration of motor braking energy to source, the application range of PWM Converter has been rapidly extended in industrial application. Nowadays, vector control algorithm and space vector PWM(SVPWM) method are applied to improve the performances of PWM Converter, but vector control algorithm and SVPWM require to use Microprocessor and other digital devices in hardware, causing costly and somewhat large dimension system. In every practical application of energy conversion equipments, the design and implementation should be carried out considering cost and performance. High performance and low cost is the best choice for energy conversion equipments. So, this paper presents the practical design method and implementation results of 3-phase PWM Converter with analog hysteresis current controller, and verifies the performances of unit power factor operation and energy regeneration operation via experimental results.

  • PDF

THE COORDINATED CONTROL OF TCSC AND PSS TO IMPROVE POWER SYSTEM DAMPING (저주파 진동 감쇠를 위한 PSS와 TCSC의 협조 제어)

  • Kim, T.H.;Seo, J.C.;Moon, K.S.;Son, K.M.;Lee, S.S.;Park, J.K.;Moon, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.652-654
    • /
    • 1996
  • A study of the coordinated control of a TCSC and an existing PSS is presented when both are used to damp the low frequency oscillations. TCSC is modeled by the first order delay model. Linear quadratic Gaussian controller is used for designing PSS and TCSC supplementary controller. The performance of the proposed controllers is simulated in a one machine infinite bus model. As a result, it is shown that to damp the low frequency oscillations efficiently, it is necessary to control TCSC and PSS simultaneously.

  • PDF

Combined Design of PSS and STATCOM Controllers for Power System Stability Enhancement

  • Rohani, Ahmad;Tirtashi, M. Reza Safari;Noroozian, Reza
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.734-742
    • /
    • 2011
  • In this paper a robust method is presented for the combined design of STATCOM and Power System Stabilizer (PSS) controllers in order to enhance the damping of the low frequency oscillations in power systems. The combined design problems among PSS and STATCOM internal ac and dc voltage controllers has been taken into consideration. The equations that describe the proposed system have been linearized and a Fuzzy Logic Controller (FLC) has been designed for the PSS. Then, the Particle Swarm Optimization technique (PSO) which has a strong ability to find the most optimistic results is employed to search for the optimal STATCOM controller parameters. The proposed controllers are evaluated on a single machine infinite bus power system with the STATCOM installed in the midpoint of the transmission line. The results analysis reveals that the combined design has an excellent capability in damping a power system's low frequency oscillations, and that it greatly enhances the dynamic stability of power systems. Moreover, a system performance analysis under different operating conditions and some performance indices studies show the effectiveness of the combined design.

Double Electro-Magnetic Force Compensation Method for the Micro Force Measurement (미소 힘 측정을 위한 이중 전자기힘 보상방법)

  • 최임묵;우삼용;김부식;김수현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.2
    • /
    • pp.104-111
    • /
    • 2003
  • Micro force measurement is required more frequently for a precision manufacturing and investment in fields of precision industries such as semiconductor, chemistry and biology, and so forth. Null balance method has been introduced as an alternative of a loadcell. Loadcells have advantages in aspects of low cost and easy manufacturing, but have also the limitation in resolution and sensitivity to environment variations. In this paper, null balance method is explained and the dominant parameters related to system performances are mentioned. Null position sensor, electromagnetic system and controller are investigated. Also, the characteristic experiment is carried out in order to estimate the resolution and the measurement range. In order to overcome the limitation by the drift of position sensor and the performance of controller, double electromagnetic force compensation method is proposed and experimented. After controlling and filtering, the resolution under $\pm$ 1mg and measurement range over 300g could be obtained.

Fuzzy Controller Design of MIMO System with Decoupling Feedforward Compensator (비결합 전향 보상기를 갖는 선형다변수 시스템의 퍼지제어기 설계)

  • Song, Jeong-Hwa;Jung, Dong-Keun;Kim, Young-Chol
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.407-409
    • /
    • 1998
  • In order to improve the tracking performance of $2{\times}2$ multivariable control systems, a fuzzy control algorithm with feedforward compensator is represented. The method consists in two steps. First, neglecting interconnections. one designs a fuzzy controller to each individual loop. In the second stage, low-order transfer functions of outputs to reference inputs are estimated. We propose a design method of the feed forward compensator based on the transfer functions. An illustrative example are shown.

  • PDF

Modeling and Analysis of Three Phase PWM Converter (3상 PWM 컨버터의 모델링 및 해석)

  • 조국춘;박채운;최종묵
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.328-335
    • /
    • 1999
  • Three phase full bridge rectifier has been used to obtain dc voltage from three phase ac voltage source. The rectifier system has drawbacks that power factor is low and power flow is unidirectional. Therefore, when dc voltage increases due to regeneration of power the dynamic resister for dissipation of regeneration power must be installed. But three phase PWM converter can be controlled to operate with unity power factor and bidirectional power flow. Therefore when the PWM converter is used as do supply system, the dissipating resistor is not necessary. On this thesis, in order to design a controller having good performance, the hee phase PWM converter is completely modeled by using circuit DQ-transformation and thus a general and simple instructive equivalent circuit is obtained; the inductor set becomes a second order gyrator-coupled system and three phase inverter becomes a transformer as well. Under given phase angle(${\alpha}$) and modulation index(MI) of the three phase inverter, the dc and ac characteristics are obtained by analysis of the transformed equivalent circuit The validity of the equivalent circuit is confirmed through PSPICE simulation. And based on the dc and ac characteristics a controller with unity power factor is proposed.

  • PDF