• Title/Summary/Keyword: Low Luminance

Search Result 270, Processing Time 0.032 seconds

Low voltage driving red phosphorescent organic light-emitting devices

  • Kim, Tae-Yong;Suh, Won-Gyu;Moon, Dae-Gyu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.461-464
    • /
    • 2008
  • We have developed low voltage driving red phosphorescent organic light-emitting devices using a new electron transport layer. $Ir(piq)_3$ and CBP were used as a phosphorescent dopant and an emission host, respectively. The device exhibits a luminance of $1000\;cd/m^2$ at a voltage of 2.8 V. This high luminance at low voltage results from a high electron conduction behavior of the new electron transport layer.

  • PDF

Performance Analysis of Laboratory and Field Luminance for Phosphorescent Line Marking and Preliminary Study of Luminance Analysis Using Digital Images (축광노면표시의 실내 및 현장 휘도 성능분석과 디지털이미지를 이용한 휘도분석 사전연구)

  • Kim, Sang Tae;Lee, Yong Mun;Kim, Heung Rae;Choi, Kee Choo
    • International Journal of Highway Engineering
    • /
    • v.18 no.6
    • /
    • pp.145-152
    • /
    • 2016
  • OBJECTIVES : Visibility at night can be improved by using retroreflection for short distances and phosphorescent line markings for long distances. In this study, we analyzed the characteristics of the phosphorescent line marking through a laboratory luminance test. Field performance analysis was performed through tests conducted on the road. We also examined the luminance measurement methods using the digital image obtained during the phosphorescent visibility evaluation. METHODS : In this study, the laboratory luminance test of the phosphorescent line marking was conducted using seven specimens to characterize the luminance changes according to the type of the glass beads, the thickness of the phosphorescent line marking, and the brightness and irradiation time of the light source. Phosphorescent and general line markings were made at 150 m to investigate the field luminance performance. A preliminary review of the luminance measurement methods was made using a digital image from a digital single-lens reflex (DSLR) camera. The measured luminance ratio of the general and the phosphorescent line markings was compared with the calculated luminance ratio using luminance analysis. RESULTS : Through the laboratory luminance test, it was seen that the change in luminance, which corresponds to the brightness of the light source, appears large but the influence of the thickness and irradiation time is low. The field performance test of the phosphorescent line marking conducted on the road involved measuring the luminance on the day the marking was made and 7 days after the marking was made. The luminance was found to be $190mcd/m^2$ at 30 min after sunset and approximately $10-12mcd/m^2$ 4h after sunset. The results of the luminance test were captured using a digital image for each time group. The luminance ratio of the phosphorescent line marking, when compared to that of the general line marking, showed a similar trend within a 13% maximum error. Additionally, when this luminance ratio is compared to the direct field measurement, it could be confirmed that the luminance ratio, as captured in the digital image, showed a similar tendency. CONCLUSIONS : 1) The change in luminance corresponding to the brightness of the light source is significant in comparison with that corresponding to the thickness and the irradiation time. In addition, the results of the field test for the phosphorescent line marking satisfied the phosphorescent fire protection standard. 2) We examined the validity of the luminance measurement method using a digital image and we concluded that the change in the luminance ratio shows a similar tendency in both the cases. The results can form the basis for luminance measurement methodology for the construction and maintenance of phosphorescent line markings.

Electricla Properties of Xe Plasma Flat Lamp (Xe 플라즈마 평판 램프의 전기적 특성)

  • Choi, Yong-Sung;Cho, Jae-Cheol;Hong, Kyung-Jin;Lee, Woo-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.12a
    • /
    • pp.35-38
    • /
    • 2006
  • As a display becomes large recently, Acquisition of high luminance and Luminance uniformity is becoming difficult in the existing CCFL or EEFL backlight system. So, study for a performance enhancement has enforced. but lamp development of flat type is asked for high luminance and a luminance uniformity security in of LCD and area anger trend ultimately. In this paper, we changed a tip shape of an electrode for production by the most suitable LCD backlight surface light source, and confirmed discharge characteristic along discharge gas pressure and voltage, and confirmed electric field distribution and discharge energy characteristic through a Maxwell 2D simulation. Therefore the discharge firing voltage characteristic showed a low characteristic than a rectangular type and round type in case of electrode which used tip of a triangle type, and displayed a discharge electric current as a same voltage was low.

  • PDF

Color Image Digital Watermarking based on a Luminance-Chrominance Signal (휘도-색차 신호 기반의 컬러 영상 디지털 워터마킹)

  • Seo Jung-Hee;Lim Young-Jin;Han Eun-Young;Park Hung-Bog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.565-568
    • /
    • 2006
  • In the luminance and chrominance signal, luminance signal creates gray images, and is capable of making each color component compatible with monochrome system. And color components of luminance and chrominance signals are useful to encode or convert the signal because they have low correlation. Each color signal has low correlation statistically, but they are not independent of one another. Therefore, this paper proposes the watermark inserting algorithm for luminance and chrominance signal in the domain of frequency founded on wavelet, considering the interdependent characteristics of color components. Therefore, it can guarantee the robustness and invisible of digital watermark.

  • PDF

Luminance Properties of Argon Gas Using Inductively Coupled Plasma (유도 결합형 플라즈마를 이용한 아르곤 가스의 휘도 특성)

  • Lee, Young-Hwan;Her, In-Sung;Hwang, Myung-Keun;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1915-1917
    • /
    • 2004
  • Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. Optical characteristics significantly depend on the RF power and gas pressure of the plasma. This paper describes the measurement of luminance as a function of RF power and gas pressure with a goal of finding optimal operating conditions of the electrodeless lamp. The gas pressure was varied from 10 [mTorr] to 500 [mTorr] and the RF power was varied from 10 [W] to 200 [W]. It was found that the luminance tends to be decreased when argon pressure is increased, and the luminance is increased as RF power is increased. It was also found that the luminance per unit RF power is high when the argon pressure is low and when the RF power is in the range of 30 [W]${\sim}$40 [W].

  • PDF

Luminance Performance of a Room with Light Guide and Blind Systems by Mockup Experiments (혼합형 채광조절장치가 실내공간의 휘도분포에 미치는 영향에 관한 Mockup 실험평가)

  • Shin, Hwa Young;Ahn, Hyun Tae;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.65-72
    • /
    • 2007
  • As ecological design elements, daylighting can be applied to provide adequate illumination on visual tasks to create an attractive visual environment and to save electrical energy. Daylighting control systems reject direct sunlight and penetrate it onto the ceiling or to deep into the room. This study aims to evaluate the luminance environment of sloped light guide with automated venetian blind systems according to sun angle changes. For evaluation, a mock-up model was used and the south facing side-window mounted between the clerestory window and the view window. To assess luminance performance, 3 view points of luminance were monitored. As results, the conventional and lightshelves show ideal luminance ratio between workplane and surroundings(3:1) and workplane and darkness area(2:1) due to total ratio of surroundings and darkness area has lower ratio than workplane. Compared to the lightshelves window, conventional window shows unrelieved effect in between the workplane and brightness area(1:5). It means that there has low deviation according to the required standards. Also, compared to the ratio between the brightness area and darkness area(2~6:1) conventional window with high deviation(10~20:1) provide discomfort glare due to the excessively strong contrast, while lightshelves window shows a required luminance ratio that provide a three-dimensional effect to occupants. Therefore, luminance distribution indicate that application of a lightshelves and blinds not only has a significantly positive effect but also offers higher luminance quality in a daylit room

Hardware Implementation of Low-power Display Method for OLED Panel using Adaptive Luminance Decreasing (적응적 휘도 감소를 이용한 OLED 패널의 저전력 디스플레이 방법 및 하드웨어 구현)

  • Cho, Ho-Sang;Choi, Dae-Sung;Seo, In-Seok;Kang, Bong-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.7
    • /
    • pp.1702-1708
    • /
    • 2013
  • OLED has good efficiency of power consumption by having no power consumption from black color as different with LCD. when it has white color, all RGB pixel should be glowing with high power consumption and that can make it has short life time. This paper suggest the way of low power consumption for OLED panel using adaptive luminance enhancement with color compensation and implement it as hardware. This way which is based on luminance information of input image makes converted luminance value from each pixel in real time. There is with using the basic idea of chromaticity reduction algorithm, showing new algorithm of color correction. And performance of proposed method was confirmed by comparing the conventional method in experiments about 48.43% current reduction. The proposed method was designed by Verilog HDL and was verified by using OpenCV and Windows Program.

POLYGONIOSCOPE a new instrument for fastest luminance, color and viewing angle measurement with highest accuracy

  • Laur, Juergen
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1370-1373
    • /
    • 2008
  • This paper introduces a novel display measuring instrument that allows accurate, spectro-radiometric measurement of the complete viewing cone while the measuring time is similar to that of a CCD camera with transform lens optics. Actually the new instrument, named POLYGONIOSCOPE, is orders of magnitude faster compared to a conventional spot spectrometer.

  • PDF

Effect of Hump Electrode on the Discharge Voltage of ac PDP with Fence Electrode (Fence 전극을 가진 ac PDP의 방전전압특성에 미치는 돌기 전극의 영향)

  • Dong, Eun-Joo;Ok, Jung-Woo;Yoon, Cho-Rom;Lee, Hae-June;Lee, Ho-Joon;Park, Chung-Hoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.261-267
    • /
    • 2008
  • One of the most important issues in fence-type PDP is low luminance and luminous efficiency. To improve luminance and luminous efficiency, new sustain electrode structure which contains long discharge gap is necessary. However, it causes rise of firing voltage. In this paper, a new fence electrode structure is proposed in order to solve these problems. To drop the firing voltage, tow hump shaped electrodes is added on the main discharge electrode, and distance between two humps is controlled. The experimental results show that the test panel with the narrow horizontal gap(40um) between two humps shows low firing voltage by 17V compared with 80um gap in spit of similar luminance and luminous efficiency.

Moving Picture Compression using Frame Classification by Luminance Characteristics (명암특성에 따른 프레임 분류를 이용한 동영상 압축기법)

  • Kim, Sang-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.51-56
    • /
    • 2011
  • This paper proposes an efficient moving picture compression for video sequences with luminance variations. In the proposed algorithm, the luminance variation parameters are estimated and local motions are compensated. To detect the frame required luminance compensation, we employ the frame classification based on the cross entropy between histograms of two successive frames, which can reduce the computational redundancy. Simulation results show that the proposed method yields a higher peak signal to noise ratio (PSNR) than that of the conventional methods, with a low computational load, when the video scene contains large luminance variations.