• Title/Summary/Keyword: Loss and damage

Search Result 1,702, Processing Time 0.028 seconds

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

Analysis of Importance of Damaged Area Assessment Indices using Analytic Hierarchy Process (AHP 기법을 활용한 훼손지 평가항목의 중요도 분석)

  • Song, Ki-Hwan;Choi, Yun-Eui;Seok, Young-Sun;Jeon, Seong-Woo;Sung, Hyun-Chan;Seo, Jung-Young;Chon, Jin-Hyung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.23 no.6
    • /
    • pp.15-28
    • /
    • 2020
  • Urbanization and industrialization have caused increasing damage to national lands, and ecological restoration has proceeded without any specific assessment of this damage. The purpose of this study is to select indices to assess damaged areas through literature review and panel discussions, and to derive the importance of damaged area assessment indices by analyzing them through the Analytic Hierarchy Process (AHP). This study has derived, via literature review, six types of damage and a total of 18 related assessment indices. A total of 51 responses were collected from surveys and given to experts, and an AHP analysis conducted. As a result of the analysis, "Landform change (0.268)" was of the highest importance, with associated damage types as follows: "Soil contamination (0.193)", "Vegetation damaged (0.149)", "Surface soil loss (0.143)", "Change in soil physiochemical property (0.125)", and "Vegetation decline (0.122)". The analysis determined that the item of the highest importance in the overall assessment of damage was "Slope occurred area (0.100)", and that "Conductivity (0.022)" was of the lowest importance. This study can be presented as a criterion in determining the type and degree of damage in setting priorities for future ecological restoration projects.

Risk Assessment of Energy Storage System using Event Tree Analysis (ETA를 이용한 에너지저장시스템의 위험성 평가)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Kim, Eui-Sik;Park, Young-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.3
    • /
    • pp.34-41
    • /
    • 2016
  • The purpose of this paper is to conduct ETA on six items of ESS: the whole system, battery, BMS, PCS, ESS and cable. To achieve that, ESS work flow and its components are categorized. Based on performance, human, environmental, management, and safety, this paper drew initiation events (IE) and end states (ES). ETA is applied to the main functions of each item, and the end states that may occur in one initiation event are suggested. In addition, detailed classification was performed to induce various end states on the basis of the suggested initiation events ; loss of grid electricity of ESS, loss of battery electricity(DC) of battery, impairment of electric function of BMS, loss of grid electricity(AC) of PCS, loss of data of EMS, Mechanical damage of cable, event sequence analysis conducted on the basis of event trees. If the suggested IEs and ESs are applied on the basis of ESS event cases, it is expected to prevent the same kinds of accident and operate ESS safely.

The relationship between security incidents and value of companies : Case of listed companies in Korea (정보보안 사고가 기업가치에 미치는 영향 분석: 한국 상장기업 중심으로)

  • Hwang, Haesu;Lee, Heesang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.25 no.3
    • /
    • pp.649-664
    • /
    • 2015
  • Recently, the risk of security incidents has been increased due to change of IT environment and development of new hacking methods. Event study methodology that measures the effect of a specific security incident on the stock price is widely adopted to analyze the damage cost of security incidents on market value. However, analysis of company's temporary stock price change is limited to immediate practical implication, and reputation loss should be considered as a collateral damage caused by security incidents. We analyzed 52 security incidents of listed Korean companies in the last decade; by refining the criteria presented by Tobin's q, we quantitatively showed that the companies has significantly higher reputation loss due to security loss than the other companies. Our research findings can be used in order that the companies can efficiently allocate its resource and investment for information security.

The Study of Development of permanent wave for Additives of Collagen (콜라겐을 첨가한 퍼머넌트웨이브제의 개발)

  • Lee, Ha-Na;Cho, Hee-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3277-3283
    • /
    • 2010
  • In this study, in order to find effects of collagen manipulation on hair in permanent wave treatment, it was conducted measurement and analysis on hair curl formation, thickness, tensile strength, methylene blue absorbance, and moisture loss after manipulating concentration proportion of collagen in permanent wave treatment on normal hair. As a result, it was found that by contrast with applying the reductant, hair thickness, tensile strength, methylene blue absorbance, and moisture loss were decreased when applied collagen in permanent wave treatment the higher concentration proportion of collagen was applied, the less damage was occurred on hair However curl formation capacity was decreased in permanent wave treatment as concentration proportion of collagen was increased. Therefore, the appropriate concentration proportion of collagen was 2% in order to reduce hair damage in permanent wave treatment.

A Numerical Study on the Occurrence Scope of Underground Cavity and Relaxation Zone Considering Sewerage Damage Width and Soil Depth (하수관거 파손폭과 토피고를 고려한 지중 공동 및 이완영역 발생 규모에 관한 수치해석적 연구)

  • You, Seung-Kyong;Ahn, HeeChul;Kim, Young-Ho;Han, Jung-Geun;Hong, Gigwon;Park, Jeong-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.35 no.1
    • /
    • pp.43-53
    • /
    • 2019
  • This paper described a result of finite element analysis considering sewerage damage scale and soil depth, in order to analyze quantitatively for cavity and relaxation zone of underground due to sewerage damage. The mechanical model, which was verified by previous studies, was applied to the finite element analysis. In addition, the mechanical behavior of the soil around the sewerage damage due to the soil loss was simulated by using the forced displacement. Based on finite element analysis results, characteristics of the void ratio distribution, ground subsidence, and shear stress distribution according to sewerage damage scale and soil depth were analyzed. And then, The boundaries of the underground cavity and relaxation zone were determined by using the shear stress reduction characteristics of the ground. Also, an occurrence scope of the cavity and relaxation zone was quantitatively evaluated by the change of sewerage damage scale and soil depth.

Perception of Safety of Regular Polish and Gel Polish and Degree of Nail Damage (일반 폴리시와 젤 폴리시의 안전성 인식 및 손톱 손상도)

  • Park, Jin-Kyoung;Lee, Jae-Nam
    • Journal of the Korean Applied Science and Technology
    • /
    • v.38 no.2
    • /
    • pp.595-607
    • /
    • 2021
  • This study attempted to investigate the perception of safety of regular polish and gel polish and degree of nail damage. For this, a questionnaire survey and an experiment were performed against women in their 20-50s, and the results found the followings: In terms of effectiveness, safety and degree of nail damage, gel polish was higher than regular polish. In addition, moisture/sebum levels and trans-epidermal water loss (TEWL) decreased after the experiment. Specifically, such reduction was greater in gel polish. When the nail surface was observed by a scanning electron microscope (SEM) after polish removal, gel polish revealed severe nail damage. The above results confirm that gel polish is greater than regular polish in terms of influence on the degree of nail damage. Therefore, it is anticipated that the study results would be available as basic data in keeping nails healthy and beautiful.

Effect of Deer Antler Drink Supplementation on Blood Pressure, Blood Glucose and Lymphocyte DNA Damage in Type 2 Diabetic Patients (당뇨환자에 있어서 녹용추출물의 섭취가 혈압, 혈당 및 임파구 DNA 손상에 미치는 영향)

  • Kim Hye-Young;Jeon Eun-Jae;Park Yoo Kyoung;Kang Myung-Hee
    • Journal of Nutrition and Health
    • /
    • v.37 no.9
    • /
    • pp.794-800
    • /
    • 2004
  • Deer Antler has been known for its traditional oriental medicinal properties and has been widely used to promote growth, boost immune function, treat blood loss and chronic joint pain. Recent study showed imported (New Zealand) Deer Antler was beneficial in reducing the side effects of cancer treatments. However, there was no intervention study conducted on the effect of Korean Deer Antler on reducing the oxidative stress to patients with diabetes. One of the sensitive ways to measure endogenous oxidative stress is by measuring cellular DNA damage using single cell gel electrophoresis (COMET assay). This study was conducted to investigate the possible beneficial effect of commercial Deer Antler drink (provided by Chung-yang Deer Farm) on lymphocyte DNA damage and blood glucose of diabetic patients. Ten patients (4 men, 6 women) participated in the study and consumed 2 pouches of Deer Antler drink every day for 20 days. Blood was collected on the morning before and after the intervention for lymphocyte isolation and blood glucose analysis. Both systolic and diastolic blood pressure showed a tendency to decrease but did not reach statistical significance after the trial. Blood glucose level was not affected by the supplementation. After the intervention, over 50% reduction were noted in the cellular DNA damage, expressed as tail length (TL) and tail moment (TM: tail length ${\times}$ percent tail DNA) . Although we did not obtain beneficial effect on lowering blood glucose levels in the patients, this results suggest that Deer Antler may initially act in protecting endogenous DNA damage in short-term experiment.

Evaluation of Corrosion and Cavitation Erosion Resistance of Sealed Aluminum Alloy after Anodizing Treatment in Seawater (양극산화 후 실링처리된 알루미늄 합금의 해수 내 내식성과 캐비테이션 침식 저항성 평가)

  • Park, Il-Cho;Lee, Jung-Hyung;Han, Min-Su;Kim, Seong-Jong
    • Journal of Surface Science and Engineering
    • /
    • v.51 no.2
    • /
    • pp.87-94
    • /
    • 2018
  • Various sealing techniques were applied to the anodized 5083 aluminum alloy for marine environment to reduce corrosion and cavitation erosion damage. Electrochemical experiments and cavitation erosion tests were conducted to evaluate the corrosion resistance and cavitation resistance of the anodic oxide film treated with sealing in natural seawater solution. Then, damaged surface morphology was analyzed by scanning electron microscope(SEM) and 3D microscope. As the results of the electrochemical experiments, it was observed that the surface damage of all the experimental conditions in the anodic polarization experiment was locally grown by the combination of crack and corrosion damage. In the Tafel analysis, the corrosion resistance of all sealing treatment conditions was improved compared to the anodizing. On the other hand, cavitation erosion tests showed that the anodizing and all the sealing treatment conditions generated local pit damage by cavitation erosion attack and grew to crater damage in the observation of damaged surface by SEM. Also, the weight loss and the surface damage depth measured with the experiment time presented that most of the sealing treatment conditions showed better cavitation erosion resistance than the anodizing, and they had an incubation period at the beginning of the experiment.

Behaviors of Cavitation Damage in Seawater for HVOF Spray Coated Layer with WC-10Co4Cr on Cu Alloy (WC-10Co4Cr으로 초고속 화염용사 코팅된 Cu 합금의 해수내 캐비테이션 손상 거동)

  • Han, Min-Su;Kim, Min-Sung;Jang, Seok-Ki;Kim, Seong-Jong
    • Journal of Surface Science and Engineering
    • /
    • v.45 no.6
    • /
    • pp.264-271
    • /
    • 2012
  • Due to the good corrosion resistance and machinability, copper alloy is commonly employed for shipbuilding, hydroelectric power and tidal power industries. The Cu alloy, however, has poor durability, and the seawater application at fast flow condition becomes vulnerable to cavitation damage leading to economic loss and risking safety. The HVOF(High Velocity Oxygen Fuel) thermal spray coating with WC-10Co4Cr were therefore introduced as a replacement for chromium or ceramic to minimize the cavitation damage and secure durablility under high-velocity and high-pressure fluid flow. Cavitation test was conducted in seawater at $15^{\circ}C$ and $25^{\circ}C$ with an amplitude of $30{\mu}m$ on HVOF WC-10Co4Cr coatings produced by thermal spray. The cavitation at $15^{\circ}C$ and $25^{\circ}C$ exposed the substrate in 12.5 hours and in 10 hours, respectively. Starting from 5 hours of cavitation, the coating layer continued to show damage by higher than 160% over time when the temperature of seawater was elevated from $15^{\circ}C$ to $25^{\circ}C$. Under cavitation environment, although WC-10Co4Cr has good wear resistance and durability, increase in temperature may accelerate the damage rate of the coating layer mainly due to cavitation damage.