• Title/Summary/Keyword: Lobe Shape

Search Result 93, Processing Time 0.026 seconds

Development of an Integrated System for Automated Design of Gerotor Oil Pump (지로터 오일 펌프용 통합적 설계 자동화 시스템 개발)

  • Kim, Jae-Hun;Kim, Chul
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.2 s.179
    • /
    • pp.88-96
    • /
    • 2006
  • A gerotor pump is suitable for oil hydraulics of machine tools, automotive engines, compressors, constructions and other various applications. Especially the pump is an essential machine element of an automotive engine to feed lubricant oil. The subject of this paper is the theoretical analysis of the internal lobe pump which is a particular type of positive displacement pump. The main components of the pump are rotors; usually the outer rotor profile is characterized by lobes with circular shape, while the inner rotor profile is determined as conjugate as the outer rotor profile. For this reason the topic presented here is the definition of the geometry of the rotors starting from the design parameters. The choice of these parameters is subject to some limitations in order to avoid cusp and loop between rotors. And the integrated system which is composed of three main modules has been developed through AutoLISP & Visual Basic and CAD considering various design parameters. It generates automatically an designed model for a general type of a gerotor pump and allows us to calculate two performances indexes commonly used for the study of positive displacement pumps: the flow rate and flow rate irregularity. Results obtained using the system enable the designer and manufacturer of oil pump to be more efficient in this field.

The Multi-Mode Circular Horn Antenna for the Transfer of High Power (고전력 전송을 위한 다중 모드 원형 혼 안테나에 관한 연구)

  • 최선웅;이병무;박경순;윤영중;소준호;임중수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.4
    • /
    • pp.363-368
    • /
    • 2003
  • In this paper, the characteristics of the horn antenna for the high power transfertation system is stuided and several kinds of a horn antenna are compared and finally a conical hem antenna using multi-mode is proposed. In the high power system, the efficiency of power transfer is very important. Therefore the feeding hem of a reflector must have a circular symmetric radiation pattern. And the side lobe must be suppressed to reduce a spillover power loss and interference. By using multi-mode in a circular hem antenna, the whole length can be shorter and the radiation pattern can be adjusted according to the shape and direction of a reflector. This is confirmed by the experiments.

Diagnostic Imaging of Massive Hepatocellular Carcinoma in 5 Dogs (개의 종괴형 간세포암종에 대한 진단 영상 소견에 대한 고찰)

  • Choi, Ji-Hye;Kim, Ah-Rim;Keh, Seo-Yeon;Choi, Hee-Yeon;Jang, Jae-Young;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.474-482
    • /
    • 2010
  • Hepatocellular carcinoma (HCC) is a primary hepatic neoplasms in dogs. Three types of HCC such as massive, nodular and diffuse form were reported. Massive HCC is most common and has relatively better prognosis than other forms because this type of HCC can be removed surgically and has low frequency of relapse or metastasis. Diagnostic image can provide useful information for shape and internal structure of the hepatic mass as well as the location and adhesion or invasiveness of the mass to establish surgical plan to remove the mass safely. In this study, we investigated diagnostic features of massive HCC in 5 dogs. Radiography showed soft tissue mass in cranial abdomen in 3 dogs. On ultrasonography, all dogs had a solitary hepatic mass with mixed echo pattern with anechoic cysts, which represented necrosis and hemorrhage. The radiographic and ultrasonographic findings of affected hepatic lobe were compared with the macroscopic findings through laparotomy. Computed tomography was performed to check metastasis and figure out the origin of the mass in two dogs. Ultrasonography is useful and relatively sensitive examination for diagnosis and planning for surgery in canine massive HCC.

On the wing venation and scales of Dendrolimus spectabilis Butler (I) (솔나방의 시맥(翅脈)과 인편(鱗片)에 관(關)한 연구(硏究) (I))

  • Yun, Jeong Koo
    • Journal of Korean Society of Forest Science
    • /
    • v.2 no.1
    • /
    • pp.59-65
    • /
    • 1962
  • The objects of this experiment are to find out the local variation of the Dendrolimus Spectabilis Butler, of which sample was first collecteted 15 bodies of male and 35 bodies of female adult at Suwon area. the wing veins and the scale shape have been observed through the microscope (100) and the scale size (from the bottom of the scale to the top of the lobe) has also been measured by the micrometer. The results of this experiment are as follows: 1. There is nodifference between the venation of the male body and that of the female body. Also we can not find any differences between the right and the left wing, and between each body. The fore wings consit of 13 longitudinal veins and the only one "V" shape cross vein which is between the 5th and 6th vein. The hind wings consist of 9 longitudinal veins and the only one "V" shape cross vein which is mentioned above. 2. The scale types are divided into 4 Groups in its shape. (A) The scales of I Group are short and the lower parts of them almost look like a circle, having a small projection at their bottom. The upper parts of them have 2 or 10 lobes. We can find the lobes with fine hairs or the lobes without them at the top of the scales. (B) The scales of II Group are longer than that of I Group. The shape of the lower parts of the scales is similar to that of I Group. The upper parts of the scales have 2 or 10 lobes. (C) The scales of III Group are long and almost alike in a long wedgeshape. The upper parts of the scales have 2 Or IO lobes and we can find long fine hairs at the top of each lobe. (D) The scales of IV Group are long and the shape of the lower parts of the scales is similar to that of III Group. The lobes are short and not sharp. We can find 2 or 9 lobes. 3. The scales of I Group and II Group are distributed on the whole surface except on the outer margin. The most scales of III Group are distributed on the wing base. The scales of IV Group are distributed on the outer margin only. The scales with 4 or 5 lobes are most widely distributed not considering their Group or distributing parts. 4. In I Group the variation of the scale length become gradually greater as the number of the lobes are increasing. In II, III, IV Group, however, the variation of the scale length is in direct opposition to the above mentioned. The variation of the scale width becomes pretty small in any Groups and the scale width become wider as the number of the lobes are increasing. 5. The source of the wing colouration is pigmnetal colour, and the wing colouration is expressed by the amount of brown and white scales.

  • PDF

SIR analysis for Enhancing Image Quality in Underwater Acoustic Lens System (수중음향렌즈 카메라에서 영상 품질 향상을 위한 SIR 분석)

  • Lee, Jieun;Im, Sungbin;Shim, Taebo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.4
    • /
    • pp.181-190
    • /
    • 2014
  • The underwater acoustic lens system is one of the systems getting high-resolution images on the seafloor by the beam forming method using acoustic lens. The beam forming using acoustic lenses reduces complexity and driving power. When receiving an incoming beam with the acoustic lens array, beam pattern analysis and arrangement problem of the array sensor must be addressed. Introducing SIR (Signal to Interference Ratio), the relationship among sensor interval, beam pattern and image quality would be analyzed. Generally if the sensor interval getting wider, the less effect of the side lobes makes SIR high. If the amplitude of a side lobe is high, SIR is generally getting low. The type of the apodization function changes the width, shape and amplitude of both main lobe and side lobes. Thus an appropriate apodization function can improve SIR. In this paper, SIR is stable at the sensor interval of 13mm with 0-10dB, which is not high relatively. By applying the Chebyshev function, the SIR becomes 80dB over the sensor interval of 37 mm or higher. The Hann and triangular functions demonstrate better SIR when the sensor interval becomes narrower.

Effects of a Blindfold in Improving Concentration (착용형 시야 가리개가 집중력 향상에 미치는 영향)

  • Chung, Soon-Cheol;Choi, Mi-Hyun;Kim, Hyung-Sik
    • Science of Emotion and Sensibility
    • /
    • v.24 no.1
    • /
    • pp.37-44
    • /
    • 2021
  • A study was conducted on the effects of improving concentration by obscuring the peripheral vision using a blindfold that only covers the left and right sides of the field of view. The blindfold was trapezoidal in shape (5 × 4.8 cm in length and width) and was fixed to the left and right sides of the glasses with fixing clips. The material was a black-colored polypropylene (PP) and weighed 2.3 g including the clip. Qualitative and quantitative evaluations were performed on 50 healthy college students during the 15 days of using a blindfold. The qualitative analysis was performed utilizing a questionnaire regarding the improvement of concentration and the structure of the blindfold. EEG was measured while watching a learning video that required attention for quantitative analysis, and signal power and ERD/S analyses were performed for the mid β band (15-20 Hz) at the F4 position, which was the frontal lobe. The results showed that 40 of the 50 people reported improved concentration when they wore a vision shield, and 80% of the total subjects found it to be effective. From the quantitative evaluation, the ERS peak (p = 0.023) and the ERD + ERS peak value showed a significant difference (p = 0.017). In conclusion, concentration still improved even if only the left and right visual fields were used. Thus, it is expected that blindfolding could be used in various environments that require concentration.

Internal Flow and Evaporation Characteristic inside a Water Droplet on a Vertical Vibrating Hydrophobic Surface (수직 진동하는 소수성 표면 위 액적의 내부유동 및 증발특성 연구)

  • Kim, Hun;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.7
    • /
    • pp.579-589
    • /
    • 2015
  • This study aims to understand the internal flow and the evaporation characteristics of a deionized water droplet subjected to vertical forced vibrations. To predict and evaluate its resonance frequency, the theories of Lamb, Strani, and Sabetta have been applied. To visualize the precise mode, shape, and internal flow inside a droplet, the experiment utilizes a combination of a high-speed camera, macro lens, and continuous laser. As a result, a water droplet on a hydrophobic surface has its typical shape at each mode, and complicated vortices are observed inside the droplet. In particular, large symmetrical flow streams are generated along the vertical axis at each mode, with a large circulating movement from the bottom to the top and then to the triple contact line along the droplet surface. In addition, a bifurcation-shaped flow pattern is formed at modes 2 and 4, whereas a large ellipsoid-shape flow pattern forms at modes 6 and 8. Mode 4 has the fastest internal flow speed and evaporation rate, followed by modes 8 then 6, with 2 having the slowest of these properties. Each mode has the fastest evaporation rate amongst its neighboring frequencies. Finally, the droplet evaporation under vertical vibration would lead to more rapid evaporation, particularly for mode 4.

Shape Oscillation and Detachment of Droplet on Vibrating Flat Surface (진동하는 평판 위의 액적의 형상 진동 및 제거 조건에 대한 연구)

  • Shin, Young-Sub;Lim, Hee-Chang
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.4
    • /
    • pp.337-346
    • /
    • 2014
  • This study aimed to understand the mode characteristics of a droplet subject to periodic forced vibration and the detachment of a droplet placed on a plate surface. An surface was coated with Teflon to clearly observe the behavior of a droplet. The contact angle between the droplet and surface and the hysteresis were found to be approximately $115^{\circ}C$ and within $25^{\circ}C$, respectively. The coating process was performed in a clean room that had an environment with a low level of contaminants and impurities such as air dust, detergents, and particles. To predict the resonance frequency of a droplet, theoretical and experimental approaches were applied. Two high-speed cameras were configured to acquire side and top views and thus capture different characteristics of a droplet: the mode shape, the detachment, the separated secondary droplet, and the waggling motion. A comparison of the theoretical and experimental results shows no more than 18 discrepancies when predicting the resonance frequency. These differences seem to be caused by contact line friction, nonlinear wall adhesion, and the uncertainty of the experiment. For lower energy inputs, the contact line of the droplet was pinned and the oscillation pattern was axisymmetric. However, the contact line of the droplet was de-pinned as the oscillation became more vigorous with increased energy input. The size of each lobe at the resonance frequency is somewhat larger than that at the neighboring frequency. A droplet in mode 2, one of the primary mode frequencies, exhibits vertical periodic movement as well as detachment and secondary ejection from the main droplet.

Occurrence of Chiroteuthis picteti (Teuthoidea: Chiroteuthidae) from Korea (Chiroteuthis picteti (Teuthoidea: Chiroteuthidae)의 국내출현)

  • Kang, Hyunjung;Choi, Jung Hwa;Choi, Kwang Ho;Lee, Dongwoo;Kim, Yeonghye
    • The Korean Journal of Malacology
    • /
    • v.29 no.4
    • /
    • pp.381-384
    • /
    • 2013
  • One specimen (13.4 cm ML) of Chiroteuthis picteti belonging to the family Chiroteuthidae, firstly collected from Songjeong, Southeast coastal water of Korea on May 18, 2013. It was identified as C. picteti based on the following combination of morphological character: mantle slenderly cylindrical; fin oval shape, both lobes having no anterior free lobe, FL 58.2% of ML; arms long with a formula IV > III > II > I. We propose a new Korean name, "Kin-pal-o-jing-eo-gua", "Kin-pal-o-jing-eo-sok", and "Kin-pal-o-jing-eo" for the family, genus and species, respectively.

A Clinical Study on the Value of a Scoring System of the Scanning Images in Liver Cirrhosis (간경변증(肝硬變症)의 간주사상판독(肝走査像判讀)에 있어서의 평점제적용(評點制適用)에 관(關)한 임상적(臨床的) 연구(硏究))

  • Chang, Ko-Chang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.2
    • /
    • pp.41-53
    • /
    • 1970
  • Although the radioisotope liver scan has primarily been of use in the detection of the intra-hepatic space occupying lesions, there has been an increasing awareness of its use in evaluation of liver function. In this study, the degree of hepatomegaly, changes in shape and mottling radiodensity on each lobe and splenic visualization in the liver scans done with colloidal radiogold were numerically expressed as scores under the arbitrary standard in 210 patients with liver cirrhosis. The clinical value of this scoring system was studied with special regards to the correlation between the radiogold hepatic uptake half time and conventional liver function tests. Following were the results; 1) The normal scan appeared in 6.7% of 210 patients with liver cirrhosis. 2) The colloidal radiogold hepatic uptake half time was abnormally and progressively prolonged in parallel to severity of hepatocellular dysfunction. The mean hepatic uptake half time in cirrhosis showing normal scan was $2.76{\pm}0.73$ minutes. 3) The scoring system was well correlated with the serum albumin and globulin levels, A/G ratio and BSP retention. There was some correlative tendency in alkaline phosphatase activity. 4) There was no correlation with the thymol turbidity test, cholesterol levels, transaminase activities and bilirubin levels. 5) The spleen was visualized in 38.6% of total patients with liver cirrhosis. Excluding normal scans in liver cirrhosis, the spleen was visualized in 41.3%. 6) The scoring system appears to confirm the clinical diagnosis and to give a reliable estimate of the degree of hepatocellular dysfunction in patients with liver cirrhosis.

  • PDF