• Title/Summary/Keyword: Load share

Search Result 155, Processing Time 0.031 seconds

A ZVS Resonant Converter with Balanced Flying Capacitors

  • Lin, Bor-Ren;Chen, Zih-Yong
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1190-1199
    • /
    • 2015
  • This paper presents a new resonant converter to achieve the soft switching of power devices. Two full-bridge converters are connected in series to clamp the voltage stress of power switches at Vin/2. Thus, power MOSFETs with a 500V voltage rating can be used for 800V input voltage applications. Two flying capacitors are connected on the AC side of the two full-bridge converters to automatically balance the two split input capacitor voltages in every switching cycle. Two resonant tanks are used in the proposed converter to share the load current and to reduce the current stress of the passive and active components. If the switching frequency is less than the series resonant frequency of the resonant tanks, the power MOSFETs can be turned on under zero voltage switching, and the rectifier diodes can be turned off under zero current switching. The switching losses on the power MOSFETs are reduced and the reverse recovery loss is improved. Experiments with a 1.5kW prototype are provided to demonstrate the performance of the proposed converter.

Coordinated Control Strategies with and without Circulating Current in Unified Power Quality

  • Feng, Xing-tian;Zhang, Zhi-hua
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1348-1357
    • /
    • 2015
  • Under traditional unified power quality conditioner (UPQC) control, a UPQC series converter (SC) is mainly used to handle grid-side power quality problems while its parallel converter (PC) is mainly used to handle load-side power quality problems. The SC and PC are relatively independent. The SC is usually in standby mode and it only runs when the grid voltage abruptly changes. In this paper, novel UPQC coordinated control strategies are proposed which use the SC to share the reactive power compensation function of the PC especially without grid-side power quality problems. However, in some cases, there will be a circulating current between the SC and the PC, which will probably influence the compensation fashion, the compensation capacity, or the normal work of the UPQC. Through an active power circulation analysis, strategies with and without a circulating current are presented which fuses the reactive power allocation strategy of the SC and the PC, the composite control strategy of the SC and the compensation strategy of the DC storage unit. Both of the strategies effectively solve the SC long term idle problem, limit the influence of the circulating current, optimize all of the UPQC units and reduce the production cost. An analysis, along with simulation andexperimental results, is presented to verify the feasibility and effectiveness of the proposed control strategies.

An Efficient Management Scheme of Hierarchical P2P System based on Network Distance (계층적 P2P 시스템의 효율적 관리를 위한 네트워크 거리 기반 운영 기법)

  • Hong, Chung-Pyo;Kim, Cheong-Ghil;Kim, Shin-Dug
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.10 no.4
    • /
    • pp.121-127
    • /
    • 2011
  • Many peer-to-peer (p2p) systems have been studied in distributed, ubiquitous computing environments. Distributed hash table (DHT)-based p2p systems can improve load-balancing even though locality utilization and user mobility are not guaranteed. We propose a mobile locality-based hierarchical p2p overlay network (MLH-Net) to address locality problems without any other services. MLH-Net utilizes mobility features in a mobile environment. MLH-Net is constructed as two layers, an upper layer formed with super-nodes and a lower layer formed with normal-nodes. Because super-nodes can share advertisements, we can guarantee physical locality utilization between a requestor and a target during any discovery process. To overcome a node failure, we propose a simple recovery mechanism. The simulation results demonstrate that MLH-Net can decrease discovery routing hops by 15% compared with JXTA and 66% compared with Chord.

  • PDF

Analysis, Design and Implementation of a New Chokeless Interleaved ZVS Forward-Flyback Converter

  • Taheri, Meghdad;Milimonfared, Jafar;Namadmalan, Alireza;Bayat, Hasan;Bakhshizadeh, Mohammad Kazem
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.499-506
    • /
    • 2011
  • This paper presents an interleaved active-clamping zero-voltage-switching (ZVS) forward-flyback converter without an output choke. The presented topology has two active-clamping circuits with two separated transformers. Because of the interleaved operation of the converter, the output current ripple will be reduced. The proposed converter can approximately share the total load current between the two secondaries. Therefore, the transformer copper loss and the rectifier diodes conduction loss can be decreased. The output capacitor is made of two series capacitors which reduces the peak reverse voltage of the rectifier diodes. The circuit has no output inductor and few semiconductor elements, such that the adopted circuit has a simpler structure, a lower cost and is suitable for high power density applications. A detailed analysis and the design of this new converter are described. A prototype converter has been implemented and experimental results have been recorded with an ac input voltage of 85-135Vrms, an output voltage of 12V and an output current of 16A.

Dynamic Home Circuit Construction for Datacenter Networks Using LOBS-HC Ring

  • Tang, Wan;Yi, Bo;Yang, Ximi;Li, Jingcong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.9 no.5
    • /
    • pp.1606-1623
    • /
    • 2015
  • Optical switching will be applied in datacenter networks because electronic switching is costly and power-consuming. In this paper, considering the ring-based interconnection using optical switching in the core of a datacenter, we study the home circuit (HC) construction for the labeled optical burst switching with home circuit (LOBS-HC), a new paradigm trying to share wavelengths among the HCs from the same source. In particular, aiming to construct HCs dynamically and properly, a scheme named optimal path matching and symmetric HC matching (OPM-SHM) is proposed. The main idea of OPM-SHM is to dynamically construct HCs by sharing wavelength(s) not only among the same-source HCs but also with symmetric HCs which have different sources other than the original LOBS-HC features. The simulation results demonstrate that OPM-SHM achieves better performance than some other methods in terms of burst loss rate and wavelength utilization of physical links. More specially, it maintains good load balancing for the datacenter network using an LOBS-HC ring. In addition, due to the symmetric feature of SHM, the proposed scheme can decrease the upper bound of the average hop count of the routing paths to half of the ring size.

The Crack Control of Fiber Net Reinforced RC Slab (섬유망을 이용한 RC슬래브의 균열제어)

  • Bae, Ju-Seong;Kim, Kyoung-Soo;Kim, Nam-Wook;Kim, Chul-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.225-231
    • /
    • 2002
  • Severe cracks on Reinforced Concrete (RC) structures caused by structural displacement can be often one of the main reasons for the degradation of tensile and flexural rigidities of RC structures and for the deterioration of durability and serviceability of RC structures through accelerated steel corrosion. These combined factors adversely affect the performance of RC concrete, leading to shortened life time of RC structures. In consideration of these problems, we conducted 3 point bending experiments by employing three different types of concrete specimens: fiber-net reinforced concrete (FNRC), polypropylene-fiber reinforced concrete (PFRC), and plain concrete (PC). FNRC is well known for its strong corrosion resistance, light self-weight, and excellent tensile strength, while PFRC is known to be effective in crack control. FNRC was found to have the best first and final crack resistances followed by PFRC and PC, as evidenced by the highest initial crack load and the smallest final crack width, respectively. The FNRC specimens with various tensile strength of fiber net exhibited greater ultimate strengths than those for PFRC and PC. Furthermore, the crack widths of FNRC specimens were smaller than those calculated by the crack-width estimation equation of the KCI and ACI code. Therefore, we conclude that fiber net reinforcement is effective not only on crack control, but also on loading share.

Half-Bridge Zero Voltage Switching Converter with Three Resonant Tanks

  • Lin, Bor-Ren;Lin, Wei-Jie
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.882-889
    • /
    • 2014
  • This paper presents a zero voltage switching (ZVS) converter with three resonant tanks. The main advantages of the proposed converter are its ability to reduce the switching losses on the power semiconductors, decrease the current stress of the passive components at the primary side, and reduce the transformer secondary windings. Three resonant converters with the same power switches are adopted at the low voltage side to reduce the current rating on the transformer windings. Using a series-connection of the transformer secondary windings, the primary side currents of the three resonant circuits are balanced to share the load power. As a result, the size of both the transformer core and the bobbin are reduced. Based on the circuit characteristics of the resonant converter, the power switches are turned on at ZVS. The rectifier diodes can be turned off at zero current switching (ZCS) if the switching frequency is less than the series resonant frequency. Therefore, the reverse recovery losses on the rectifier diodes are overcome. Experiments with a 1.6kW prototype are presented to verify the effectiveness of the proposed converter.

A Ubiquitous Interface System for Mobile Robot Control in Indoor Environment (실내 환경에서의 이동로봇 제어를 위한 유비쿼터스 인터페이스 시스템)

  • Ahn Hyunsik;Song Jae-Sung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.1
    • /
    • pp.66-71
    • /
    • 2006
  • Recently, there are lots of concerning on ubiquitous environment of robots and URC (Ubiquitous Robotic Companion). In this paper, a practical ubiquitous interface system far controlling mobile robots in indoor environments was proposed. The interface system was designed as a manager-agent model including a PC manager, a mobile manager, and robot agents for being able to be accessed by any network. In the system, the PC manager has a 3D virtual environment and shows real images for a human-friendly interface, and share the computation load of the robot such as path planning and managing geographical information. It also contains Hybrid Format Manager(HFM) working for transforming the image, position, and control data and interchanging them between the robots and the managers. Mobile manager working in the minimized computing condition of handsets has a mobile interface environment displaying the real images and the position of the robot and being able to control the robots by pressing keys. Experimental results showed the proposed system was able to control robots rising wired and wireless LAN and mobile Internet.

Frequency Control Method of Grid Interconnected Microgrid Operating in Stand Alone Mode (계통연계형 마이크로그리드의 독립운전시 주파수 제어에 관한 연구)

  • Chae, Woo-Kyu;Lee, Hak-Ju;Park, Jung-Sung;Cho, Jin-Tae;Won, Dong-June
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1099-1106
    • /
    • 2012
  • Microgrid is a new electrical energy system that composed of various generators, renewable energy, batteries and loads located near the electrical customers. When Microgrid is interconnected with large power system, Microgrid don't need to control the frequency. But in case of the outage or faults of power system, Microgrid should control the frequency to prevent the shutdown of Microgrid. This paper presents the frequency control methods using the droop function, being used by synchronous generators and EMS(Energy Management System). Using droop function, two battery systems could share the load based on locally measured signals without any communications between batteries. Also, we suggest that EMS should control the controllable distributed generators as P/Q control modes except batteries to overcome the weakness of droop function. Finally we suggest the two batteries systems to prolong the battery's life time considering the economical view. The validation of proposed methods is tested using PSCAD/EMTDC simulations and field test sites at the same time.

A Database Retrieval Model for Efficient Gene Sequence Alignment (효율적인 유전자 서열 비고를 위한 데이타베이스 검색 모델)

  • 김민준;임성화;김재훈;이원태;정진원
    • Journal of KIISE:Databases
    • /
    • v.31 no.3
    • /
    • pp.243-251
    • /
    • 2004
  • Most programs of bioinformatics provide biochemists and biologists retrieve and analysis services of gene and protein database. As these services retrieve database for each arrival of user's request, it takes a long time and increases server's load and response time. In this paper. by utilizing database retrieval patterns of sequence alignment programs in bioinformatics, grouping method is proposed to share database retrieval between many requests. Carpool method is also proposed to reduce response time as well as to increase system expandability by combining new arriving requests with the previous on going requests. The performance of our two proposed schemes is verified by mathematic analysis and simulation.