• Title/Summary/Keyword: Load power factor

Search Result 847, Processing Time 0.029 seconds

Safely Improving Method to Zero-Harmonics Current with 4-Pole Low Voltage Circuit Breaker Equipped N-phase Trip Device (4극 저압차단기 N상 Trip장치를 사용한 영상고조파 안전성 개선방안)

  • Ki, Che-Ouk;Kim, Ju-Chul;Choi, Chang-Kyu
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.458-461
    • /
    • 2009
  • In 3-phase 4 wire system, appearance of the $3^{rd}$ harmonic current by increasing non-liner load is the one of causes overheating neutral wire of power line, and apparatus. So it is necessary to protect power-factor decreasing by the $3^{rd}$ harmonic, and electric power apparatus, and line safely, in this study, power system accidents caused by the $3^{rd}$ harmonic were investigated, then harmonic components analysis and unbalanced load analysis got accomplished. As result, we proposed the method to protect the power line and apparatus from over-current of neutral line by using the most economic 4-pole low voltage circuit breaker.

  • PDF

Implementation of Advanced Frequency Measurement Algorithm (DSP를 이용한 개선된 주파수 측정 알고리즘 구현)

  • Lee, Jung-woo;An, Jong-hyun;Oh, Yong-taek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.465-468
    • /
    • 2009
  • A frequency in electrical power system changes by the load fluctuation in utility grid, has an influence on a connected generator, and ultimately brings a big trouble in the power system. Therefore, a quick measurement of system frequency and governor control of power system is a very important factor in the reliability and the economic feasibility. In this study, An improve algorithm that measures the power system frequency quickly and accurately is suggested, simulated by using Matlab and programmed using C code through DSP6713 KIT. This algorithm is tested to the arbitrary voltage waveform input. The results show that the suggested algorithm is effective in the accurate and quick frequency measurements.

  • PDF

Improvement of prediction methods of power increase in regular head waves using calm-water and resistance tests in waves

  • Chun, Ho-Hwan;Lee, Cheol-Min;Lee, Inwon;Choi, Jung-Eun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.278-291
    • /
    • 2021
  • This paper applies load variation method to predict speed-power-rpm relationship along with propulsive performances in regular head waves, and to derive overload factors (ITTC, 2018). 'Calm-water tests' and 'resistance test in waves' are used. The modified overload factors are proposed taking non-linearity into consideration, and applied to the direct powering, and resistance and thrust identity method. These indirect methods are evaluated through comparing the speed-power-rpm relationships with those obtained from the resistance and self-propulsion tests in calm water and in waves. The objective ship is KVLCC2. The load variation method predicts well the speed-power-rpm relationship and propulsion performances in waves. The direct powering method with modified overload factors also predicts well. The resistance and thrust identity method with modified overload factor predicts with a little difference. The direct powering method with overload factors predicts with a relatively larger difference.

Characteristics of induction motor by changing the second exciting E.M.F. (2차 격자기전력에 의한 유도전동기의 특성)

  • 황영문
    • 전기의세계
    • /
    • v.15 no.2
    • /
    • pp.1-7
    • /
    • 1966
  • It is well known that the speed of induction motor can be controlled in wide range by changing the second exciting e.m.f. of rotor circuit, but that is well not practised because of its complicated system. In order to simplify such a system, the Kramer system of which silicon rectifier substitutes for synchronous converter has analyzed in this paper. The result of this investigation show that in this system, only the equivlent synchronous speed it changed by second exciting e.m.f., but the mechanical output power, torque and power factor is not changed, and that this system is able to compensate the regulated speed on account of the load changed.

  • PDF

Applied Video Statistics

  • Beek, W.H.M. Van;Cordes, C.N.;Raman, N.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1584-1587
    • /
    • 2005
  • Although the picture quality of today's displays is very good already, a continuous improvement is desirable as the new larger display sizes increase the visibility of artifacts. A contributing factor for picture quality enhancement through smart video processing and algorithm design is the information gathered from video statistics. Interesting parameters gathered from video statistics are e.g. the image- and display load, the usage of the color gamut, the estimated power consumption and the occurrence of static image parts. Examples of applications that can benefit from video statistics are power calculations, color gamut mapping algorithms, dynamic backlight control for LCD panels and LED backlights for LCD panels.

  • PDF

A High Performance ZVT-PWM Boost Rectifier with Soft Switched Auxiliary Switch (스프트 스위칭 보조 스위치를 가지는 ZVT-PWM 부스트 컨버터)

  • 김윤호;김윤복;정재웅
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.265-268
    • /
    • 1998
  • This paper presents a soft-switching average current control PWM high power factor boost converter. Conventional boost ZVT-PWM converter has a disadvantage of hard-switching for auxiliary switch at turn-off. A soft switched auxiliary switch is proposed to achieve a high performance ZVT-PWM boost rectifier. The simulation and experimental results show that soft switching operation can be maintained for wide line and load range, which in turn improves the converter performance in terms of efficiency, switching noise and circuit reliability.

  • PDF

ESTIMATION OF DEVICE CURRENT IN PWM INVERTERS

  • Ji, Ho-chul;Jeong, Seoung-Gi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.506-511
    • /
    • 1998
  • This paper gives and analytical expression of the average and rms currents of switching devices in volt-age-fed PWM inverters. It is shown that the device currents are represented by a function of the power factor of the load and the normalized output voltage of the inverter. The validity of the derived formulas is confirmed with simulation and experiment, showing that the modulation method has a minor effect on the characteristics of the device current.

  • PDF

FUNDAMENTAL RESEARCH OF A NOVEL 3/1 PHASE CONVERTER FOR ELECTRIFIED RAILROAD

  • Farshad, Siamak;Rongtai, Hao
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.955-960
    • /
    • 1998
  • Electrified railroads inject large amount of harmonics, negative sequence and reactive currents to electric supply systems. This paper introduces application of active filter as a 3/1 phase converter for electrified railroad. In this system active filter compensate harmonics, negative sequence and reactive currents and electric railroad and active filter together act as a balance three-phase load with power factor 1

  • PDF

A Study on the Effects of Maintenance Schedule in a Competitive Electricity Market (경쟁시장에서 보수계획의 수익영향과 최적보수 방향)

  • Kim, C.S.;Rhee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.593-595
    • /
    • 2003
  • The introduction of electricity industry provides generators incentives to recover the related cost through the market. Hence, the generator should sell his/her electricity at high market-clearing price with optimal operation of his/her power plant. The maintenance of power plant is the most critical factor in affecting generators' decision-making. This paper analyzes technique for establishing maintenance schedule reflecting recovery cost and considers differences in monthly load pattern in minimizing LOLP.

  • PDF

Choice technique develovement of transformer core (변압기 코아의 선정 기술 개발)

  • Lee, O.K.;Kim, S.Y.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1604-1606
    • /
    • 2003
  • In this paper, investigated the core of transformer of high power factor and high effectiveness about design and choice technology. Transformer that use existent general core and material is high no-load loss power. Presented core choice method that can reduce loss. Could do to reduce loss according to choice technology of use material more than about 10 (%). Presented classification and check list by Core's type.

  • PDF